FOUR BUTTON CONTROL WITH LCD OPERATION
Your whirlpool bathtub has been equipped with Electronic Controls to
provide features that allow you to customize your bathing experience to
your individual preference. Please familiarize yourself with the features
and operating instructions below in order to maximize the enjoyment
you receive from your bath. These operating instructions should be
used in conjunction with the other instructions and warnings provided
with your whirlpool bathtub in order to fully understand and safely
utilize the bathtub.
TABLE OF CONTENTS
1. OPERATING INSTRUCTIONS
MAIN MENU
LIGHT FUNCTIONS
PUMP FUNCTIONS
BLOWER FUNCTIONS
TIMER SETTINGS
2. TROUBLESHOOTING & FAQ
Power Left
Arrow
Right
Arrow
LCD Screen
OK
TM
BATH CONTROLS
OK
2
1. OPERATION INSTRUCTIONS
1. Power On / Main Menu
a. Press and Hold Power Key to power up controller and activate the
system. Program setting will appear two sec for reference. NOTE:
If water level is too low, system will not activate and display will
temporarily display “No H2O.
b. Main screen will display current active settings
c. Press and Hold Power Key to power system OFF.
2. Light Functions
a. Press the Power Key to cycle to Light menu.
b. Press the “OK” Key to toggle Light ON.
c. Use arrow keys to select light color menu
d. Press “OK” to cycle light colors and shows. (Colors listed on page 4)
e. To turn lights OFF, tap arrow keys to select “ON.
Press “OK” key to turn lights OFF.
3. Pump Functions
a. Press the Power Key to cycle to Pump menu.
b. Press the “OK” Key to toggle pump ON/OFF.
c. Press RIGHT arrow to select available jet settings. Available features
include Neck Jet1, Back Jet1, Foot Jet, Aux1, Neck Jet2, Back Jet2, Foot
Jet2, Aux2.
d. Press “OK” to cycle through settings of selected jets:
i. 0 = OFF
ii. 1 = Constant ON (NOTE: For waterfall only 0 or 1 are available)
iii. 2 = 0.5 second jet sequence pattern
iv. 3 = 1.0 second jet sequence pattern
v. 4 = 1.5 second jet sequence pattern
e. Press LEFT arrow to select a dierent seat or zone. Seat zones are
numbered. (Ex: Neck Jet1, Neck Jet2, Foot Jet1, Foot Jet2, etc)
f. To turn OFF, press arrow keys to select “ON. Press “OK” key to turn OFF.
LCD DISPLAY: MAIN MENU
LCD DISPLAY: PUMP
LCD DISPLAY: LIGHT
3-B
2-B
ACTIVE FUNCTIONS TIMER
TEMP
3-E
2-C,D
POWER KEY
Power On/OFF
Cycle between
Sub-Menus
OK
“OK” KEY
Cycle Sub-Menu
Settings and
Options
ARROW KEYS
Move between
Sub-Menus
Selections
3
4. Blower Functions
a. Press the Power Key to cycle to the Blower menu.
b. Press the “OK” Key button to toggle ON. The blower will start on the
highest xed blower speed setting of “6”.
c. Use arrow keys to select blower speed settings. To adjust the “xed”
blower setting press “OK” Key. The blower has six xed speeds that
can be adjusted from “6” to “1”.
d. Use arrow keys to select blower mode settings. The blower defaults to
the “xed” setting. Press “OK” to cycle between Wave, Pulse and Fixed.
e. To turn blower OFF, press arrow keys to select “ON. Press “OK” key to
turn blower OFF.
f. Purge/Clean Cycle: Fifteen minutes after the blower is turned o and
when no water is detected, the blower will automatically activate for
2-3 minutes. The display will read “Hydroclean.” During the purge
cycle the blower cannot be deactivated by touching any buttons on
the control.
5. Timer Settings
a. Press the Power Key to cycle to the Timer menu.
b. Use arrow keys to adjust system o timer. The timer can be adjusted in
preset increments between 5 and 60 minutes.
1. LOW WATER LEVEL / NO WATER
If water level is too low, system will not activate and display will show “No
H2O” icon.
2. HOW TO CHECK PROGRAM SETTINGS
To check the current control program, power ON. The current control
program will be displayed on the screen.
3. TOO HOT” ERROR
If water temp exceeds 111°F the screen will display the message “Too
Hot” and the system will shut down completely. When the water temp
drops below 111°F the system can be activated.
5. LIGHT DOES NOT TURN ON
If the light will not turn on, there may be a bad connection or defective
light. Contact technical support.
2. FAQ & TROUBLESHOOTING
LCD DISPLAY: BLOWER
4-B
4-C
LCD DISPLAY: BLOWER
LCD DISPLAY: TIMER
4-D
5-B
LOW WATER/ NO WATER
PROGRAM SETTINGS
TEMP OVER 111°F
PROGRAM #CUSTOMER ID
4
2. FAQ & TROUBLESHOOTING
6. AUTOMATIC PURGE/CLEANING CYCLE
a. After water is drained from the tub, an automatic cleaning cycle activates the system blower.
b. If purge cycle is active the control pad will not turn the blower o.
c. The blower should automatically de-activate after 2-3 minutes if the purge cycle is active.
7. PUMP DOES NOT TURN ON
a. Check water level.
b. Pump will not engage without a sucient water level.
8. BLOWER DOES NOT TURN ON
Check electrical connections to the Blower.
9. SYSTEM TURNS OFF DURING USE
a. Check timer settings. Default system timer is 20 minutes.
b. Check for loss of power
10. WHAT IS THE LIGHT COLOR SEQUENCE?
The system is programmed with seven solid colors and one light “show.
White
Light Blue
Yellow
Green
Purple
Dark Blue
Red
Three Second Color Cycle (Cycles through all colors)
For all other technical issues please contact CMP technical support via email at
SUPPORT@C-M-P.COM or by phone at 1-800-733-9060 x 220.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

CMP 26413-100-110 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI