Contec DO-32LN-FIT Owner's manual

Category
Digital & analog I/O modules
Type
Owner's manual

This manual is also suitable for

F&eIT Series
Ethernet Remote I/O
F&eIT N Series
Isolated Digital Input/Output Unit
DIO-1616LN-FIT
DIO-0808LN-FIT
Isolated Digital Input Unit
DI-32LN-FIT
DI-16LN-FIT
Isolated Digital Output Unit
DO-32LN-FIT
DO-16LN-FIT
Users Guide
CONTEC CO., LTD.
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT
i
Check Your Package
Thank you for purchasing the CONTEC product.
The product consists of the items listed below.
Check, with the following list, that your package is complete. If you discover damaged or missing
items, contact your retailer.
Product Configuration List
- Unit (One of the following) ...1
[DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT,
or DO-16LN-FIT]
- First Step Guide …1
- Power connector …1
- I/O connector
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT …4
DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT …2
- Rubber feet …4
- Magnet …2
- CD-ROM [F&eIT Series Setup Disk] *1 …1
*1 The CD-ROM contains various software and User’s Manual (this manual)
Unit I/O connector Magnet Power connector Rubber feet
CD-ROM First step guide
[F&eIT Series Setup Disk]
ii
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT
Copyright
Copyright 2008 CONTEC CO., LTD. ALL RIGHTS RESERVED.
No part of this document may be copied or reproduced in any form by any means without prior written
consent of CONTEC CO., LTD.
CONTEC CO., LTD. makes no commitment to update or keep current the information contained in
this document. The information in this document is subject to change without notice.
All relevant issues have been considered in the preparation of this document. Should you notice an
omission or any questionable item in this document, please feel free to notify CONTEC CO., LTD.
Regardless of the foregoing statement, CONTEC assumes no responsibility for any errors that may
appear in this document or for results obtained by the user as a result of using this product.
Trademarks
F&eIT is a registered trademark or trademark of CONTEC CO., LTD. Other company and product
names that are referred to in this manual are generally trademarks or registered trade trademark.
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT
iii
Table of Contents
Check Your Package ............................................................................................................................ i
Copyright ............................................................................................................................................ ii
Trademarks .......................................................................................................................................... ii
Table of Contents ............................................................................................................................... iii
1. Before Using the Product 1
About the Unit ..................................................................................................................................... 1
Features ........................................................................................................................................ 2
Functions ...................................................................................................................................... 4
Support Software .......................................................................................................................... 5
Option list ..................................................................................................................................... 5
Customer Support................................................................................................................................ 6
Web Site ....................................................................................................................................... 6
Limited One-Year Warranty ............................................................................................................... 6
How to Obtain Service ........................................................................................................................ 6
Liability ............................................................................................................................................... 6
Safety Precautions ............................................................................................................................... 7
Safety Information ....................................................................................................................... 7
Handling Precautions ................................................................................................................... 7
Security Warning ......................................................................................................................... 9
Environment ............................................................................................................................... 10
Inspection ................................................................................................................................... 10
Storage ....................................................................................................................................... 10
Disposal ...................................................................................................................................... 10
2 Unit Nomenclature and Settings 11
Nomenclature of Unit Components ................................................................................................... 11
Setting a Group ID ............................................................................................................................ 15
Setup Method ............................................................................................................................. 15
Setting a Unit ID ............................................................................................................................... 16
Setup Method ............................................................................................................................. 16
3 Connection and Installation 17
Installation Method ........................................................................................................................... 17
Mounting on a DIN Rail............................................................................................................. 17
Desktop Installation ................................................................................................................... 19
Wall Installation ......................................................................................................................... 19
Installation Using the Magnet .................................................................................................... 20
Installation Conditions ...................................................................................................................... 22
iv
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT
Connection Method ........................................................................................................................... 24
Connecting an Interface Connector ............................................................................................ 24
Signal Layout on the Interface Connector .................................................................................. 25
Connecting Input Signals ........................................................................................................... 30
Input Circuit ............................................................................................................................... 30
Connecting a Switch ................................................................................................................... 30
Examples of Connectinon to an External Device ....................................................................... 31
Connecting Output Signals ......................................................................................................... 32
Output Circuit ............................................................................................................................. 32
Connection to the LED ............................................................................................................... 33
Example of Connection to TTL Level Input .............................................................................. 33
Example of a Connection between Input and Output Unit ......................................................... 34
Surge Voltage Countermeasures ....................................................................................................... 35
Digital Filter (Hardware) ................................................................................................................... 36
Digital Filter Operation Principle ............................................................................................... 36
Fail safe function ............................................................................................................................... 38
Operation outline of fail safe function ....................................................................................... 38
Setting the fail safe function ....................................................................................................... 38
Connection Method ........................................................................................................................... 40
How to Provide Power to This Product ...................................................................................... 40
Connecting the Unit to the SH-8008(FIT)H ............................................................................... 41
4 Setup 43
Setup Procedures ............................................................................................................................... 43
Quick Setup ................................................................................................................................ 43
Custom Setup ............................................................................................................................. 44
Utility Software Operating Procedures ............................................................................................. 46
5 Access to Devices 47
Access using API-CAP(W32) ........................................................................................................... 47
6 Virtual Address Map 49
Virtual Address Map ......................................................................................................................... 49
Virtual Address Space ................................................................................................................ 49
Common Device Information (00000000h) ............................................................................... 50
Device-Specific Information (00100000h) ................................................................................. 52
Definition of Device-Specific Information (00200000h) ........................................................... 53
I/O space (00300000h) ............................................................................................................... 53
Firmware Update Area (FFE00000h) ......................................................................................... 60
F&eIT Protocol Specifications .......................................................................................................... 61
Basic Specifications ................................................................................................................... 63
Control Information .................................................................................................................... 70
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT
v
7 System Reference 73
Specifications .................................................................................................................................... 73
Common Specifications ............................................................................................................. 73
Specifications < DIO-1616LN-FIT > ...................................................................................... 74
Specifications < DI-32LN-FIT > ............................................................................................. 75
Specifications < DO-32LN-FIT > ........................................................................................... 75
Specifications < DIO-0808LN-FIT > ...................................................................................... 76
Specifications < DI-16LN-FIT > ............................................................................................. 77
Specifications < DO-16LN-FIT > ........................................................................................... 77
Physical Dimensions ......................................................................................................................... 78
vi
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT
1. Before Using the Product
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT
1
1.
Before Using the Product
This chapter provides information you should know before using the product.
About the Unit
This product is an isolated digital input and output unit of F&eIT remote I/O system that realizes
monitoring and control of devices scattered remotely, through PCs connected to Ethernet.
Since existing network infrastructure can be used, the system can be built easily by just connecting with
LAN cables.
It is possible to connect external devices, such as adjacent switches, lamps and LEDs, to perform
input/output of digital signals.
Compact design not restricting installation location (188.0(W) x 78.0(D) × 30.5(H)) makes it easy to
install the product within the panel or device using DIN rail mounting jigs, or on the floor or wall.
Windows driver library is supplied. It is possible to confirm the operations through the diagnosis
monitor without any programming.
DIO-1616LN-FIT
The < DIO-1616LN-FIT > has the 16ch of Optocoupler isolated inputs and 16ch of Optocoupler
isolated open-collector outputs (input : 12 - 24VDC specification, output : 12 - 48VDC
specification). Input section corresponds to both of current sink and current source outputs. The
output rating is max. 24VDC, 150mA or 48VDC, 50mA per ch.
DIO-0808LN-FIT
The < DIO-0808LN-FIT > has the 8ch of Optocoupler isolated inputs and 8ch of Optocoupler
isolated open-collector outputs (input : 12 - 24VDC specification, output : 12 - 48VDC
specification). Input section corresponds to both of current sink and current source outputs. The
output rating is max. 24VDC, 150mA or 48VDC, 50mA per ch.
DI-32LN-FIT
The < DI-32LN-FIT > has the 32ch of Optocoupler isolated inputs (12 - 24VDC specification).
Input section corresponds to both of current sink and current source outputs.
DI-16LN-FIT
The < DI-16LN-FIT > has the 16ch of Optocoupler isolated inputs (12 - 24VDC specification).
Input section corresponds to both of current sink and current source outputs.
DO-32LN-FIT
The < DO-32LN-FIT > has the 32ch of Optocoupler isolated open-collector outputs (12 - 48VDC
specification). The output rating is max. 24VDC, 150mA or 48VDC, 50mA per ch.
DO-16LN-FIT
The < DO-16LN-FIT > has the 16ch of Optocoupler isolated open-collector outputs (12 - 48VDC
specification). The output rating is max. 24VDC, 150mA or 48VDC, 50mA per ch.
1. Before Using the Product
2
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT
Features
< I/O : DIO-1616LN-FIT, DIO-0808LN-FIT >
- Optocoupler isolated inputs (for use with current sink output / current source output), Optocoupler
isolated open-collector outputs (current sink type)
The < DIO-1616LN-FIT > has the 16ch of Optocoupler isolated inputs (for use with current sink output
/ current source output) and 16ch of Optocoupler isolated open-collector outputs (current sink type).
The < DIO-0808LN-FIT > has the 8ch of Optocoupler isolated inputs (for use with current sink output /
current source output) and 8ch of Optocoupler isolated open-collector outputs (current sink type).
The output rating is max. 24VDC, 150mA or 48VDC, 50mA per ch.
Common terminal provided per 8ch, capable of supporting a different external power supply.
You can check the digital input or output by using the LED indicator.
- Optocoupler bus isolation
As the Ethernet controller (PC) side is isolated from the input and output interfaces by Optocouplers,
this product has excellent noise performance.
- This product has a digital filter to prevent wrong recognition of input signals from carrying noise or a
chattering.
This product has a digital filter to prevent wrong recognition of input signals from carrying noise or a
chattering. All input terminals can be added a digital filter, and the setting can be performed by
software.
- Fail safe function
When communication failure occurs, such as LAN cable disconnection, it is possible to notify the
external devices by outputting a specific user-defined signal pattern.
< Input : DI-32LN-FIT, DI-16LN-FIT >
- Optocoupler isolated inputs (for use with current sink output / current source output)
The < DI-32LN-FIT > has the 32ch of Optocoupler isolated inputs (for use with current sink output /
current source output).
The < DI-16LN-FIT > has the 16ch of Optocoupler isolated inputs (for use with current sink output /
current source output).
Common terminal provided per 8ch, capable of supporting a different external power supply.
You can check the digital input by using the LED indicator.
- Optocoupler bus isolation
As the controller (PC) side is isolated from the input interfaces by Optocouplers, this product has
excellent noise performance.
- This product has a digital filter to prevent wrong recognition of input signals from carrying noise or a
chattering.
This product has a digital filter to prevent wrong recognition of input signals from carrying noise or a
chattering. All input terminals can be added a digital filter, and the setting can be performed by
software.
1. Before Using the Product
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT
3
< Output : DO-32LN-FIT, DO-16LN-FIT >
- Optocoupler isolated open-collector outputs (current sink type)
The < DO-32LN-FIT > has the 32ch of Optocoupler isolated open-collector outputs (current sink type).
The < DO-16LN-FIT > has the 16ch of Optocoupler isolated open-collector outputs (current sink type).
The output rating is max. 24VDC, 150mA or 48VDC, 50mA per ch.
Common terminal provided per 8ch, capable of supporting a different external power supply.
You can check the digital output by using the LED indicator.
- Optocoupler bus isolation
As the controller (PC) side is isolated from the output interfaces by Optocouplers, this product has
excellent noise performance.
- Fail safe function
When communication failure occurs, such as LAN cable disconnection, it is possible to notify the
external devices by outputting a specific user-defined signal pattern.
< Common >
- Compact design not restricting installation location (188.0(W) x 78.0(D) x 30.5(H))
Compact design of 188.0(W) × 78.0(D) × 30.5(H) does not require special installation location.
- Compatible with a wide range of power supplies : 5 to 24VDC
Compatible with a wide range of power supplies : 5 to 24VDC, and can be used in various
environments.
An FG terminal is also provided in the power connector. Furthermore, it is possible to screw fit the
power connector on to the body to prevent detachment.
- Can be used as digital input/output of Ethernet base remote I/O
As the control (monitoring and control) of digital input/output is performed via Ethernet, remote control
can be easily performed.
- Diverse installations such as screw fastening, magnet, DIN rail are possible
Installation on the floor / wall /ceiling is possible by screw fastening, magnet, rubber feet, etc.
In addition, DIN rail mounting mechanism is equipped as standard with the product, making it easy to
install the product within the panel or the device.
- Windows compatible driver libraries are attached.
Using the attached driver library makes it possible to create applications of Window. As the driver
library was designed taking into consideration compatibility with the API functions [API-PAC(W32)] of
the measurement control and communication interface board, if you have experience in these
applications, smooth programming is possible.
In addition, a diagnostic program by which the operations of hardware can be checked is provided.
In addition, using generic socket functions makes it possible to implement control under OS other than
Windows, such as UNIX machine.
1. Before Using the Product
4
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT
Functions
Generic I/O functions (data I/O operations that directly access the I/O ports)
- Input
The unit transmits a maximum of 32 channels (< DI-32LN-FIT >), 16 channels (<DIO-1616LN-FIT >, <
DI-16LN-FIT >) or 8 channels (< DIO-0808LN-FIT >) of externally supplied digital signals to a PC that
is connected to it via the LAN. Access to the unit from a PC is performed through the input port. When
an input port is read by the execution of an input command, the buffer gate associated with the input port
is opened, and the digital signals supplied from an external device are fetched in groups. During this
operation, signals that are transmitted to the unit will be [ON (closed): 1, OFF (open): 0].
- Output
The unit writes a maximum of 32 channels (< DO-32LN-FIT >), 16 channels (< DIO-1616LN-FIT >,
< DO-16LN-FIT >) or 8 channels (< DIO-0808LN-FIT >) of digital signals to an external device.
Access to the unit from a PC is performed through the output port. When data is written to the output
port by the execution of an output command, the data is held on the latch circuit that is associated with
the output port. After being electrically isolated by an Optocoupler, the digital signals are transmitted
to the connected external device through transistors. During this operation, signals that are transmitted
to the external device will be [ON (closed): 1, OFF (open): 0].
Output data monitoring function
This function allows you to keep track of the signal data that is being output.
Nomenclature
F&eIT N series :
The F&eIT N series is a general term that refers to any combination of I/O controller module with
device modules.
Each device contains a Group ID SW and a Unit ID SW.
The Group ID for this product can be set in 8 or A. The Unit ID can be set in the range 0 - 7.
If the Group ID is set to A, the Unit ID can be set in the range 0 - 7Fh, permitting up to 128 devices.
HUB :
This is a line concentration device that is used when a LAN is constructed using twisted-pair cables.
The F&eIT series includes an 8-port switching HUB unit (SH-8008(FIT)H) that is equipped with a DIN
rail mounting mechanism.
1. Before Using the Product
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT
5
Support Software
You should use CONTEC support software according to your purpose and development environment.
API-CAP(W32)
[Stored on the bundled CD-ROM F&eIT Series Setup Disk]
The API-CAP(W32) is the Windows version driver library software that provides products in the form of Win32 API
functions (DLL). Various programming languages such as Visual Basic and Visual C++ can be used to create high-
speed application software which maximizes the features of the F&eIT module. In addition, a diagnostic program,
which is useful for operation verification, is also provided.
For more details on the supported OS, applicable language and how to download the updated version, please visit the
CONTEC’s Web site (http://www.contec.com).
Option list
- POA201-10-2 : AC adapter (input : 90 - 264VAC, output : 12VDC 1.0A)
- POA200-20-2 : AC adapter (input : 90 - 264VAC, output : 5VDC 2.0A)
- POW-AD13GY : AC-DC power unit (input : 85 - 132VAC, output : 5VDC 3.0A)
- POW-AD22GY : AC-DC power unit (input : 85 - 264VAC, output : 5VDC 2.0A)
- POW-DD10GY : DC-DC power unit (input : 10 - 30VAC, output : 5VDC 3.0A)
* Check the CONTECs Web site for more information on these options.
1. Before Using the Product
6
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT
Customer Support
CONTEC provides the following support services for you to use CONTEC products more efficiently
and comfortably. No driver software is provided with this product. Please download the latest
drivers from the CONTEC web site (http://www.contec.com/). Documents including important notes
on the use of the product is also posted on the web site. Please visit the CONTEC web site before
using the product.
Web Site
Japanese http://www.contec.co.jp/
English http://www.contec.com/
Chinese http://www.contec.com.cn/
Latest product information
CONTEC provides up-to-date information on products.
CONTEC also provides product manuals and various technical documents in the PDF.
Free download
You can download updated driver software and differential files as well as sample programs available in
several languages.
Note! For product information
Contact your retailer if you have any technical question about a CONTEC product or need its price,
delivery time, or estimate information.
Limited One-Year Warranty
CONTEC products are warranted by CONTEC CO., LTD. to be free from defects in material and
workmanship for up to one year from the date of purchase by the original purchaser.
Repair will be free of charge only when this device is returned freight prepaid with a copy of the
original invoice and a Return Merchandise Authorization to the distributor or the CONTEC group
office, from which it was purchased.
This warranty is not applicable for scratches or normal wear, but only for the electronic circuitry and
original products. The warranty is not applicable if the device has been tampered with or damaged
through abuse, mistreatment, neglect, or unreasonable use, or if the original invoice is not included, in
which case repairs will be considered beyond the warranty policy.
How to Obtain Service
For replacement or repair, return the device freight prepaid, with a copy of the original invoice. Please
obtain a Return Merchandise Authorization number (RMA) from the CONTEC group office where you
purchased before returning any product.
* No product will be accepted by CONTEC group without the RMA number.
Liability
The obligation of the warrantor is solely to repair or replace the product. In no event will the
warrantor be liable for any incidental or consequential damages due to such defect or consequences that
arise from inexperienced usage, misuse, or malfunction of this device.
1. Before Using the Product
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT
7
Safety Precautions
Understand the following definitions and precautions to use the product safely.
Safety Information
This document provides safety information using the following symbols to prevent accidents resulting
in injury or death and the destruction of equipment and resources. Understand the meanings of these
labels to operate the equipment safely.
DANGER indicates an imminently hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury or in property damage.
Handling Precautions
- Do not use or store the unit in a hot or cold place, or in a place that is subject to severe temperature
changes.
(Operating temperature range: 0 - 50°C)
- Do not use or store the unit in a place subject to direct sunlight or near a heating device, such as a
stove.
- Do not use or store the unit in a dusty or humid place.
(Operating humidity range: 10 - 90%RH, No condensation)
- Do not use or store the unit near equipment generating a strong magnetic field or radio waves.
- As this unit contains precision electronic components, do not use or store it in environments subject
to shock or vibration.
- If you notice any strange odor or overheating, please unplug the power cable immediately.
- In the event of an abnormal condition or malfunction, please consult the dealer from whom the unit
was purchased.
- To avoid electric shock, please do not touch the unit with a wet hand.
- Do not modify the unit. CONTEC will bear no responsibility for any problems, etc., resulting
from modifying this unit.
- Do not open the unit casing. CONTEC will disclaim any responsibility for unit whose casing has
been opened.
- Do not strike or bend the unit. Doing so could damage the unit.
- To prevent contact malfunction, please do not touch the metallic pins on the external unit connector.
- There are switches on the unit that need to be set in advance. Be sure to check these before
installing the unit.
DAN
GER
WARNING
C
A
UTION
CA
UTION
1. Before Using the Product
8
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT
- Only set the switches on the unit to the specified settings.
Otherwise, the unit may cause a failure.
- Do not plug or unplug the cables (I/O connector) while the unit is still turned on. Otherwise, the
unit may cause a failure. Be sure that the unit is turned off.
- The unit has acquired the following FCC PART15 class A
- Regarding CE EMC Directive Notice”
The product is CE specifications certified. Note that use of AC adapter and FG grounding of
power input become mandatory to comply with these specifications. It is also recommended to
use POA201-10-2 when using AC adaptor.
However, a sufficient margin may not be secured for EMC standard. In this case, use a ferrite core
(SEIWA E04SR200935A or a compatible product) for DC cable of AC adapter. When attaching a
ferrite core to coil it around once near the connector while leaving it open, and then close it.
Image diagram
FCC PART 15 Class A Notice
This equipment has been tested and found to comply with the limits for a Class
A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
NOTE
FCC WARNING
Changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
Ferrite core
Cable
TURN: 1
TURN: 2
TURN: 3
TURN: 4
1. Before Using the Product
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT
9
Security Warning
When connecting to the network, be aware of security-related problems. See the examples of Security
measures below and set up the product properly along with the network devices.
[Information security risks]
- Unauthorized access from the outside through a network could cause the system halt, data damage, or
exposure to malware * 1.
- Invaded and used as a stepping stone, a device might attack the others through networks.
(a victim becomes an assailant)
- Information might leak without realizing due to the connection to the network.
- Secondary damages such as harmful rumors, liability in damages, social credibility fall, and
opportunity loss are expected led by the troubles described above.
*1…Malware (Malicious Software) is software that brings harm to a computer system and performs
unintended
operations.
[Security measures - e.g.]
- Do not keep using the default password. (Refer to the product manual for the password setting).
- Set a strong password.
Combined with upper and lowercase letters, and numbers so that it cannot be easily analogized
by others.
- Change the password periodically.
- Disable unnecessary network services and functions.
- Restrict access to the network with network devices.
*2
- Restrict ports to be released on the network with network devices.
- Create a closed network connection using such as dedicated network or VPN
*3.
*2…Inquire for setting procedure to manufacturers.
*3…VPN (Virtual Private Network): a secured network that wards off unauthorized access by
protecting the communication path with authentication and encryption.
Unfortunately, there are no perfect ways to avert unauthorized access or close a security hole that
are endlessly found day and night. Please understand that risks are always involved with the
Internet connection, and we strongly recommend a user should constantly update information
security measures.
1. Before Using the Product
10
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT
Environment
Use this product in the following environment. If used in an unauthorized environment, the unit may
overheat, malfunction, or cause a failure.
Operating temperature
0 - 50°C
Operating humidity
10 - 90%RH (No condensation)
Corrosive gases
None
Floating dust particles
Not to be excessive
Inspection
Inspect the product periodically as follows to use it safely.
Check that the ventilation slit has no obstruction and has no dust or foreign matter adhering.
Moreover, if there is the slit on the case side, please confirm it to the slit similarly.
Storage
When storing this product, keep it in its original packing form.
(1) Put the unit in the storage bag.
(2) Wrap it in the packing material, then put it in the box.
(3) Store the package at room temperature at a place free from direct sunlight, moisture, shock,
vibration, magnetism, and static electricity.
Disposal
When disposing of the product, follow the disposal procedures stipulated under the relevant laws and
municipal ordinances.
C
AUTION
2. Unit Nomenclature and Settings
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT
11
2
Unit Nomenclature and Settings
Nomenclature of Unit Components
Figure 2.1 shows the names of unit components.
Figure 2.1. Names of Unit Components
0
1
2
4
5
6
A
B
C
D
E
F
8
0
1
2
4
5
6
A
B
C
D
E
F
8
0
F
E
D
C
B
A
9
8
6
5
4
2
1
0
F
E
D
C
B
A
9
8
6
5
4
2
1
I/O Connector
Ethernet connector
Power input connector
LED indicator
GROUP ID
UNIT ID
LINK
ACT
2. Unit Nomenclature and Settings
12
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT
Names and Functions [Common]
Table 2.1. Names and Functions
Function
Settings & Indicator
POWER
OFF : Power off
ON : Power on
RUN
Refer to Table 2.2. Operating Modes and
Status Indicators
STATUS
OUTPUT 0-3
Displays the output status *2
OFF : No output
ON : Output
INPUT 0-3
Displays the input status *3
OFF : No input
ON : Input
LAN LED LINK OFF : Not connected
ON : Connected to the LAN
ACT OFF : Communication inactive
ON : Communication active
Group ID setup switch
Unit ID setup switch
: 0 - F
: 0 - F
Group ID : 8, A *1
8 : Normal operation mode
A : Normal operation mode *1
0 - 7, 9, B - D : Not used
E is used for Ver.UP and system recovery
mode.
F : Default initialization mode
Unit ID : 0 - 7 *1
8 - F : Not used
*1 If the “A” of Group ID is specified, the Unit ID can be set in the range 0 - 7Fh by the software.
*2 DO-32LN-FIT : OUTPUT 0 - 3
DIO-1616LN-FIT, DO-16LN-FIT : OUTPUT 0 - 1 only
DO-0808LN-FIT : OUTPUT 0 only
DI-32LN-FIT, DI-16LN-FIT : No OUTPUT LED
*3 DI-32LN-FIT : INPUT 0 - 3
DIO-1616LN-FIT, DI-16LN-FIT : INPUT 0 - 1 only
DO-0808LN-FIT : INPUT 0 only
DO-32LN-FIT, DO-16LN-FIT : No INPUT LED
2. Unit Nomenclature and Settings
DIO-1616LN-FIT, DI-32LN-FIT, DO-32LN-FIT, DIO-0808LN-FIT, DI-16LN-FIT, DO-16LN-FIT
13
Operating modes and status indicators [Common]
Table 2.2. Operating Modes and Status Indicators
Operating
mode
Starting
an operation
Condition
of Group ID
Status indicator
RUN
STATUS
Condition
Normal
op. mode
Power ON:
Reset switch ON:
Remote-reset
Set to 8 or A
ON
OFF
Normal operation
Continuous,
flashing
OFF
Resetting
OFF Continuous
flashing
Abnormal conditions
(e.g., memory check error)
ON ON Abnormal conditions
(e.g., start error)
Initialization
mode *1
Power ON:
Reset switch ON:
Remote-reset:
(does not
automatically
return to normal
operating mode)
“F” switch
settings
Continuous
flashing
Continuous
flashing
Initializing
ON
ON
Initialization complete
(To return to normal
operating mode, change
the GroupID and turn the
power on again or press
the Reset switch.)
OFF Continuous
flashing
Error during initialization
ON ON Abnormal conditions
(e.g., start error)
Ver.UP and
system recovery
mode
Power ON:
Reset switch ON:
Remote-reset:
(does not
automatically
return to normal
operating mode)
“E” switch
settings
Continuous
flashing
OFF
Starting
Continuous
flashing
Continuous
flashing
Writing to firmware
OFF Continuous
flashing
Write error occurred.
ON ON Abnormal conditions
(e.g., start error)
*1 About Initialization mode
Restore the setting of this product to its factory settings.
< Procedure >
(1) Set the Group ID to "F" and turn the power on.
(2) RUN and STATUS LEDs will start to flash.
(3) Once these LEDs stop flashing and grow solid, all settings (IP address / connection device information etc.)
will be initialized and return to its factory settings after next boot.
Connectors
Table 2.3. Connectors
Name
Specifications / Function
Ethernet
connector
Network connection port.
Communication speed : 10/100Mbps auto-detect
Communication type : Connected as full duplex or half duplex.
Power input
connector
Connector for power input
For more details on this, refer to Chapter 7, System Reference”.
I/O connector Connector for digital signal I/O.
For more details on this, refer to Chapter 7, System Reference”.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87

Contec DO-32LN-FIT Owner's manual

Category
Digital & analog I/O modules
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI