Brita PURITY Quell ST User manual

Type
User manual
PURITY Quell ST
W a t e r F i l t e r S y s t e m
08/2019
d e u t s c h
e n g l i s h
f r a n ç a i s
n e d e r l a n d s
i t a l i a n o
e s p a ñ o l
p o l s k i
d a n s k
H a n d b u c h
M a n u a l
M o d e d e m p l o i
H a n d b o e k
M a n u a l e
M a n u a l
Podręcznik
M a n u a l
русский язык
Руководство по
эксплуатации
Deutsch Seite 1 – 18
1 Begriffsübersicht
2 Allgemeine Informationen
3 Betriebs- und Sicherheitshinweise
4 Installation
5 Inbetriebnahme eines Neufilters
6 Austausch der Filterkartusche
7 Filterkapazität
8 Instandhaltung
9 Abfragemodus
10 Fehlerbehebung
11 Batterie
12 Technische Daten
13 Bestellnummern
English Page 19 – 36
1 Definition of terms
2 General Information
3 Operating and Safety Information
4 Installation
5 Commissioning a New Filter
6 Replacing the Filter
7 Filter Capacity
8 Repair
9 Query Mode
10 Troubleshooting
11 Battery
12 Technical Data
13 Order Numbers
14 Information for Australian market
Français Page 37 – 54
1 Eléments
2 Généralités
3 Consignes d’utilisation et de sécurité
4 Installation
5 Mise en service d’un nouveau filtre
6 Remplacement de la cartouche filtrante
7 Capacité de filtration
8 Entretien
9 Mode d’interrogation
10 Dépannage
11 Pile
12 Caractéristiques techniques
13 Références
Nederlands Pagina 55 – 72
1 Overzicht van de begrippen
2 Algemene informatie
3 Bedrijfs- en veiligheidsvoorschriften
4 Installatie
5 Inbedrijfstelling van nieuw filterpatroon
6 Vervangen van de filterpatroon
7 Filtercapaciteit
8 Onderhoud
9 Vraagmodus
10 Verhelpen van storingen
11 Batterij
12 Technische gegevens
13 Bestelnummers
Italiano Pagina 73 – 91
1 Panoramica delle definizioni
2 Informazioni generali
3 Informazioni sul funzionamento e sulla sicurezza
4 Installazione
5 Messa in funzione di un nuovo filtro
6 Sostituzione della cartuccia filtrante
7 Capacità filtrante
8 Manutenzione
9 Modalità di interrogazione
10 Eliminazione dei guasti
11 Batteria
12 Dati tecnici
13 Numeri d‘ordine
14 Ulteriori informazioni sul prodotto
Español Página 92 – 108
1 Términos
2 Información general
3 Indicaciones de funcionamiento y seguridad
4 Instalación
5 Puesta en marcha de un filtro nuevo
6 Cambio del cartucho filtrante
7 Capacidad del filtro
8 Mantenimiento
9 Modo de acceso
10 Solución de fallos
11 Batería
12 Datos técnicos
13 Números de pedido
Polski Strona 109 – 126
1 Przegląd pojęć
2 Informacje ogólne
3 Wskazówki dotyczące użytkowania
i bezpieczeństwa
4 Instalacja
5 Rozruch nowego filtra
6 Wymiana wkładów filtracyjnych
7 Wydajność filtra
8 Konserwacja
9 Tryb odczytu
10 Usuwanie usterek
11 Bateria
12 Dane techniczne
13 Numery zamówień
Dansk Side 127 – 143
1 Oversigt over begreber
2 Generelle informationer
3 Drifts- og sikkerhedshenvisninger
4 Installation
5 Ibrugtagning af et nyt filter
6 Udskiftning af filterpatronen
7 Filterkapacitet
8 Vedligeholdelse
9 Kontrolmodus
10 Udbedring af fejl
11 Batteri
12 Tekniske data
13 Bestillingsnumre
Русский язык Страница 144 161
1 Термины
2 Общие сведения
3 Руководство по использованию и безопасности
4 Установка
5 Ввод в эксплуатацию нового фильтра
6 Замена фильтрующего картриджа
7 Ресурс фильтра
8 Уход за фильтром
9 Режим запроса
10 Устранение неполадок
11 Аккумулятор
12 Технические параметры
13 Артикулы для заказа
P U R I T Y 4 5 0 6 0 0 1 2 0 0
4 5 0
X X
6 0 0 X
X
1 2 0 0 X X
ATTENTION! ATTENTION!
DE
EN : The PURITY replacement cartridge may only be used in combination with the pressure vessel
that has been specically designed for its size.
DE: Die PURITY Filterkartusche darf nur in Kombination mit dem Druckbehälter verwendet
werden, der speziell für ihre Größe ausgelegt ist.
F R : La cartouche PURITY peut être utilisée uniquement avec la chambre de pression qui correspond
à sa taille.
N L : Het PURITY-reservepatroon mag alleen worden gebruikt in combinatie met de drukbehuizing
die speciaal voor die maat is ontworpen.
I T : Il ltro di ricambio PURITY può essere adoperato solo in combinazione con il recipiente a pres-
sione appositamente progettato per la sua capacità.
ES : El cartucho de recambio PURITY solo puede utilizarse junto con el depósito a presión diseñado
especícamente para su tamaño.
P L : Wymienny wkład ltrujący PURITY może być używany jedynie z pojemnikiem ciśnieniowym
o odpowiadających mu rozmiarach.
DK : PURITY udskiftningspatronen må kun anvendes i kombination med trykbeholderen, som er
specielt designet til dens størrelse.
R U : Сменный картридж PURITY можно использовать только с напорным резервуаром,
который был специально разработанный под его размер.
19
EN
2 General Information
2.1 Function and Application PURITY Quell ST
The BRITA PURITY Quell ST Water Filter System is used for decarbonisation of drinking water to
prevent limescale deposits in downstream appliances. Depending on the by-pass setting, calcium,
magnesium and metal ions can be selectively removed from the drinking water during the flow pro-
cess. Furthermore, the filter material reduces cloudiness and organic impurities, as well as contents
which affect taste and odour (e.g. chlorine residues) in the filtrate and bypass water. By-pass settings
on the connector head are used to set the total hardness reduction to the local water hardness or the
requirements of the application in order to achieve an optimum water quality. The filter systems are
available in 3 different filter system sizes (PURITY 450, PURITY 600 and PURITY 1200) and each
in the version without integrated measuring and display electronics or with measuring and display
(Advanced Control System, ACS-Technology) electronics.
Filter systems with ACS Technology show you the current remaining capacity and bypass setting of
your filter cartridge, the set type and size of the filter system and the last replacement date of the
filter cartridge. This ensures optimum filter control and water filtrate quality. Further information on
the filter system with ACS Technology can be found in Chapter 5.2.
The unique IntelliBypass ensures a constant by-pass proportion over the entire usage periods, irre-
spective of the volumetric flow of the terminal device concerned. The result is a consistently high water
quality specifically tailored to the application-specific requirements and the local water conditions.
Typical applications for BRITA PURITY Quell ST water filter systems are coffee and espresso
machines, hot and cold drinks vending machines as well as steam ovens (combi ovens) and air
humidifiers.
The filter system is designed for limited spaces, especially in drinks machines and kitchen installations
and can be operated horizontally and vertically.
The food quality of BRITA water filter products has been inspected and confirmed by an independent
institute.
2.2 Guarantee provisions
The PURITY filter system is subject to the statutory guarantee of 2 years. A guarantee claim may
only be asserted if all of the instructions in this manual are followed and observed.
2.3 Storage/Transport
Adhere to the ambient conditions in the Technical Data (Chapter 12) for storage and transport.
The manual should be seen as part of the product and kept for the whole service life of the filter
system and passed on to subsequent owners.
1 Definition of Terms
1
Pressure Vessel
2
Filter Cartridge
3
Pressure Vessel Lid
4
Connector Head
(optionally with measuring unit)
5
Display Unit (optional)
6
Inlet Hose
7
Connection Inlet Hose
8
Terminal Device Connection
9
Flush Valve with Water Outlet
10
Connection of Outlet Hose
11
Filter Change Sticker
12
Kick Loops
13
Ejector Base
14
Display of the Display Unit (optional)
15
Lock
16
Mantle Handle
17
Reducer 1"– 3/4"
18
Transport Protective Cap
19
By-pass Screw
20
Lid Handle
21
Flush Hose
20
EN
2.4 Recycling/Disposal
Disposing of this product and its packaging in the correct manner protects people and the environment.
The battery and display unit must not be burnt and must not be disposed of in domestic waste.
Please ensure that these are disposed of correctly, in accordance with local regulations. See also
Chapter 11.
Used filter cartridges can be returned to the BRITA addresses listed (see back of the cover).
3 Operating and Safety Instructions
3.1 Qualified Personnel
Installation, filter replacement and maintenance of the filter system may be carried out only by
specialist staff.
3.2 Correct Use
The product can only operated perfectly and safely if it is installed, used and serviced in the manner
described in this manual.
Only solution-specific BRITA filter cartridges may be used for the applications listed.
3.3 Liability Exclusion
Installation must be performed precisely in accordance with the instructions in this manual. BRITA
shall not be held liable for any damage, including subsequent damage, arising from the incorrect
installation or use of the product.
3.4 Specific Safety Information
Only water of drinking water quality may be used as intake water for the BRITA water filter
system. The BRITA water filter system is only suitable for cold water use within the water
intake temperature stated in Chapter 12. No microbiologically impaired water or water of
unknown quality may be used without appropriate disinfection.
If there are official instructions to boil tap water, BRITA filtered water must also be boiled. When
the requirement to boil water comes to an end, the filter cartridge must be replaced and the
connections cleaned.
It is generally recommended to boil tap water for certain groups of people (e.g. people with
weakened immune systems, babies). This also applies to filtered water.
Note for people with kidney disease or dialysis patients: during the filter process, the potassium
content may be increased slightly. If you suffer from kidney disease and/or have to stick to
a special potassium diet, we recommend prior agreement with your doctor.
The water filtrate is classified in Category 2 according to DIN EN 1717.
BRITA recommends that the filter system not be decommissioned for a long period. If the BRITA
filter system is not used for several days (2–3 days), we recommend that the PURITY Quell filter
system be flushed with at least x* litres according to the table below. After stagnation periods of
over 4 weeks, the filter should be flushed with at least x** litres (see table below) or else replaced.
Please also note that the maximum usage period of the filter cartridge is 12 months (Chapter 6).
Filter system x* flush quantity
after 23 days stagnation
x** flush quantity
after 4 weeks stagnation
PURITY 450 6 litres 30 litres
PURITY 600 12 litres 60 litres
PURITY 1200 24 litres 120 litres
The filter system is not resistant to heavily concentrated cleaning agents (e.g. bleach, chlorinated
solvents, heavy oxidants) and must not come into contact with them.
The filter system must not be opened or dismantled during operation. The filter cartridge must
not be opened.
The pressure vessel and the pressure vessel lid of the filter systems have a service life of up to ten
years (from the date of installation), provided that they are installed and used correctly and the operat-
21
EN
ing conditions outlined in the Technical Data chapter are adhered to. They must always be replaced
after a maximum of ten years. The hoses must be replaced in rotation after a maximum of five years.
Production date:
Production code sticker filter cartridge and box, example: B615002010
6 Production year, here: 2016
15 Production week, here: calendar week 15
002 Batch No. Filter medium, here the second batch filled in terms of quantity
010 Serial number of the filter cartridge, here the tenth cartridge from the second batch
Production code sticker connector head - Example: 1001801 E 619316008764
1001801 BRITA identification number
E Supplier ID
6 Production year, here: 2016
19 Production week, here: calendar week 19
3 Production day from Monday (1) to Friday (5), here: Wednesday
16 Production year, here: 2016
008764 Serial identification number
Production date pressure vessel and pressure vessel lid – example: 1115
11 Production month, here: November
15 Production year, here: 2015
3.5 Safety Assembly Instructions
The terminal device operated with the filter must be free of limescale prior to installation.
The filter system can also be operated downstream of water softening systems.
Protect the filter system from sunlight and mechanical damage. Do not assemble near sources
of heat and open flames.
A stop valve must be installed before the filter system intake hose.
If the water pressure is higher than 6.9 bar or if there are statutory requirements, a pressure
reducer must be installed before the filter system.
A non-return valve according to DIN EN 13959 tested by the DVGW has been factory installed
at the water intake of the filter head.
When choosing the material for parts that come into contact with water after the BRITA filter
system, it is important to remember that, due to the process, decarbonised water contains
free carbon dioxide. For this reason, only materials that are compatible with free carbon dioxide
must be used. We recommend the use of BRITA hoses.
All parts must be installed in accordance with the country-specific guidelines on the installation
of drinking water facilities.
4 Installation
!
Caution: Prior to installation, read the Technical Data (Chapter 12) and the Operating and Safety
Information (Chapter 3). After the product has been stored and transported at temperatures below
0°C, it must be stored with the original packaging open for at least 24 hours before commissioning.
4.1 Delivery Scope
To install a PURITY Quell new filter, you need a pressure vessel
1
, filter cartridge
2
and pressure
vessel lid
3
.
Before installing, remove everything included in the delivery from the packaging and check that
everything is present:
1 x Pressure Vessel
1
1 x Pressure Vessel Lid
3
1 x Filter Cartridge
2
1 x Manual
1 x Carbonate hardness test or total hardness test
If anything is missing, please contact your local BRITA Ofce.
22
EN
4.2 Assembling the Pressure Vessel and the Pressure Vessel Lid
Stand with both feet on the kick loops
12
.
Lift the pressure vessel
1
and turn it clockwise until the mantle handles
16
are over the kick loops
12
.
Remove the transport protective cap
18
from the filter cartridge.
Check that the O-ring seal of the filter cartridge
2
is correctly seated in the
groove and also check for dirt and damage.
Note: the cartridge seat has been lubricated with food-safe lubricant at the
factory.
Stand on the kick loops
12
with both feet and place the pressure vessel lid
3
on the pressure vessel
1
. The position of the arrow marking on the lid handle
20
must match the “INSERT” groove.
Press the pressure vessel lid
3
down and turn clockwise until the lock
15
engages.
4.3 Assembly of Inlet and Outlet Hoses
Note: The inlet and outlet hoses are not included in the standard scope of delivery. The use of
BRITA hose sets is recommended (Chapter 13).
Fit inlet hose
6
at the inlet of the connector head
4
and outlet hose
10
at the outlet of the
connector head
4
.
Note: Inlet “IN” and outlet “OUT” of the connector head
4
are equipped with O-rings as
seals, therefore no additional flat seals may be used here. Check that the O-rings are seated
correctly.
!
Caution: The max. tightening torque at the 1" and 3/4" connections must not exceed 15 Nm!
Only hose connections with flat seals may be used. Hoses with conical screwed connections
damage the filter head connections and invalidate any guarantee claims. Only hoses that comply
with DVGW-W 543 may be used to connect the device.
Before assembly, note the direction of flow on the upper side of the filter head, “IN” = water inlet,
“OUT” = water outlet. Prior to installation, note installation dimensions and operating position
(Chapter 12). If no original hoses are used, the 1"3/4"
17
adapter supplied must be used to ensure
the return valve is sealed correctly (pre-tted in the water inlet).
5 Commissioning a New Filter
5.1 By-pass setting for filter systems without and with measuring and display unit
For PURITY Quell ST filter systems: identify the local carbonate hardness in degrees of
German hardness °dH (BRITA nomenclature °KH) using the enclosed carbonate hardness test.
Check the by-pass setting on the by-pass adjuster
19
.
Note: A 30% by-pass setting has been made in the factory, and might be changed to suit the
local carbonate hardness or total hardness and the application (Chapter 7).
23
EN
5.2 Commissioning the filter systems with measuring and display unit
Representation in operating mode
Local Carbonate
Hardness Set
Type/
By-Pass Proportion
Date Field: Installation or
last filter change date
Available residual
capacity in litres
Bar Display
Flow Symbol
Carbonate hardness
The units of carbonate hardness or total hardness can be set as required to German °dH (= display
setting °KH, °DH), English (°e = Clark) (= display setting °EH), French (°f) (= display setting °FH),
American (grains per gallon) (= display setting gpg) or international hardness values (mg/l CaCO
3
)
(= display setting mg/L).
If the setting for the type of hardness (= unit) is changed while the filter is operating, the values that
were set originally are converted automatically.
Bar chart
Representation of the remaining capacity using bar charts. After installation of a new filter system or
after a filter change, the symbolised filter cartridge is completely filled with 10 bars.
Bypass proportion in percentage
The by-pass proportion is defined as the proportion of decarbonised water in the total amount of
filtrate and is indicated as a percentage.
Flow symbol
When water is removed via the filter system, a graphic wave is shown on the display.
Available remaining capacity of the filter cartridge
The remaining capacity of the filter cartridge is shown in litres or in US gallons, depending on which
has been selected.
When water is removed, it counts backwards in 1 litre or 1 US gallon stages. If the cartridge is
already exhausted, the capacity is indicated as being negative by flashing.
With a remaining capacity of 20% the last two bars in the bar chart start to flash.
With a remaining capacity of 10% the last bar in the bar chart flashes with the two change arrows.
From a remaining capacity of 0% the negative bars and the change arrows flash alternately with
the remaining capacity shown in negative.
Date Field: Installation or
last filter change date
Local Carbonate
Hardness Set
Type/
By-Pass Proportion
Bar Display
Available residual
capacity in litres
Change arrow
24
EN
If the monthly limit has been reached up to a month before expiry of the set time limit, it is signalled
by the date field flashing.
If the monthly limit is 100% reached, it is signalled by alternate flashing of the date field and the
change arrows.
If the remaining capacity and the monthly limit are exceeded, the negative remaining capacity and
the date field flash alternately with the change arrows.
Date of the filter commissioning or last filter cartridge change
The date of filter commissioning or last filter cartridge change is indicated as follows:
Example: 28/10/09
28 Day, here the 28th day
10 Month, here October
09 Year, here 2009
Selecting the units of measurement
You can choose between European, American and international units of measurement on the
display.
For European units of measurement: depending on the type of filter system (STD, STM), select the
specified unit of measurement for water hardness °KH, °EH, °FH or ° DH. The unit of volume and
date format are then automatically displayed in litres and DD/MM/YY respectively.
For American units of measurement, select gpg (unit of measurement for water hardness); the
unit of volume and the date format are then automatically displayed in US gallons and MM/DD/YY
respectively.
For international units of measurement, select mg/L (unit of measurement for water hardness);
the unit of volume and the date format are then automatically displayed in litres and DD/MM/YY
respectively.
Parameterisation
The following parameters have to be entered:
Filter system type and size
STD 4 = PURITY 450 Quell ST
STD 6 = PURITY 600 Quell ST
STD 12 = PURITY 1200 Quell ST
STM 4 = PURITY 450 Steam
STM 6 = PURITY 600 Steam
STM 12 = PURITY 1200 Steam
Water hardness unit and water hardness value
The following units of hardness may be selected for the various types of filter system:
Unit of carbonate hardness for filter system types STD and STM:
°KH (German unit of hardness)
°EH (English unit of hardness)
°FH (French unit of hardness)
gpg (American unit of hardness)
mg/L (international unit of hardness)
25
EN
Monthly limit 212
Carbonate Hardness Type/Filter System Size
Date fieldExhaustion after months
Reminder function filter usage period in months
Irrespective of the remaining capacity display function, you can set a monthly limit of
2–12 months to activate a reminder function for filter replacement. If the monthly limit has been
reached up to a month before the export of the set time limit, it is signalled by the date field
flashing. Factory set to 12 months.
Example: When set to 9 months, the date field starts to flash on the display after 8 months.
Operating the display unit
To operate the display unit, it must be removed from the connecting fittings.
Slide the display housing up approx. 10 mm and pull off the display unit.
The display unit is operated using a button on the back of the display unit.
The display unit is supplied in standby mode. To activate the display, press the
button on the back once briefly and then reset after inputting the parameters.
Parameter input water hardness and filter system size
At this level, parameters needed for operation are set manually.
The type and size of filter system is selected, the unit of hardness is set, the local carbonate hard-
ness or total hardness of the tap water is entered, and the maximum cartridge service life (monthly
limit) is activated. After this the parameters must be accepted.
To activate the display, press the back button once
(< 1 second) until the data field appears.
< 1 sec
FIN
Press and hold the button (> 4 seconds and
< 10 seconds) until the parameter input for the filter
system type and size flashes.
> 4 sec
Press and hold the button (> 2 seconds) until the filter
system type (STD, STM) and corresponding value for
the filter system size (04, 06, 12) has been reached.
> 2 sec
Press the button once (< 1 second) to access the next
parameter input unit of hardness. The unit of hardness
flashes.
< 1 sec
26
EN
Press and hold the button (> 2 seconds) until the
desired unit of hardness has been selected.
> 2 sec
Press the button once (< 1 second) to access the next
parameter input hardness value. The hardness value
input flashes.
< 1 sec
Press and hold the button (> 2 seconds) until the value
for the water hardness rises and keep it pressed until
the desired value has been reached.
> 2 sec
Press the button (< 1 second) to access the next
parameter input monthly limit. The monthly limit input
flashes.
< 1 sec
Press the button (> 2 seconds) and keep it pressed
until the desired value has been reached.
> 2 sec
The set parameters can now be accepted.
If you want to accept the parameters, proceed as follows:
Press the button once (< 1 second) until the message
“Reset” appears and flashes.
< 1 sec
Press the button once (> 2 seconds) until the total
capacity (at 0% bypass) and the current date appear.
> 2 sec
The set parameters have been accepted.
Note: If no input is made within 30 seconds, the display will return to standby or operating mode
without accepting amended parameters.
Insert the display unit from the front at a height of approx. 10 mm and slide down. The loops on
the display part must be inserted in the grooves on the measuring head. Continue with Chapter
5.4 Flushing/Draining for Filter Systems with and without Measuring and Display Unit.
27
EN
5.3 By-pass setting
Determining the by-pass setting
The by-pass setting is identified according to the application and the carbonate hardness or total
hardness identified on the basis of the bypass and capacity table (Chapter 7). The by-pass is then
set on the by-pass screw
19
as follows:
Turn the by-pass screw
19
until the desired by-pass (050%) agrees with the marking.
!
Caution: Use Allen key 6mm or 7/32".
!
Caution: Never overwind the by-pass screw to avoid any damage.
5.4 Flushing/Bleeding Filter Systems with and without Measuring and Display Unit
Note: A 10 litre bucket is required for flushing/draining.
Position filter system horizontally.
Completely open flush valve
9
.
Open the inlet valve
7
at inlet hose
6
while holding the flush hose in the
bucket. Flush quantity at least 10 litres with a minimum volumetric flow of 3 l/
min (180 l/h).
Close flush valve
9
, put filter system in upright position and empty bucket.
Carefully open flush valve
9
while holding the flush hose in the bucket. Flush
quantity once again at least 10 litres.
Close flush valve
9
.
Check system for any leaks.
Note installation date of the filter system and the next exchange date on the enclosed sticker
and attach it to the pressure vessel. Note: There is space for several stickers on the pressure
vessel. Apply the new sticker with the installation date at the top position.
Note: Filter systems without measuring and display units are now ready for operation.
28
EN
5.5 Checking initialisation of filter systems with a measuring and display unit
By-pass setting in percent, remaining capacity in litres, capacity bars and the current date must
be shown in the display.
Note: If these values are not shown in the display, the filter system must be flushed again
(Chapter 5.4) until the values are shown in the display. Filter systems with a measuring and
display unit are now ready for operation. Cf. Chapters 10.6 to 10.8
6 Replacing the Filter Cartridge
!
Caution: The PURITY replacement cartridge may only be used in combination with the pressure
vessel that has been specifically designed for its size. See cover.
!
Caution: During the exchange, carefully examine all dismantled parts! Faulty parts must be
exchanged and dirty parts should be cleaned. Read the Operating and Safety Information (Chapter 3)
prior to replacement. After the product has been stored and transported at temperatures below 0 °C,
it must be stored with the original packaging open for at least 24 hours before commissioning at the
ambient temperatures stated in Chapter 12.
Filter systems without a measuring and display unit
The filter cartridge must be replaced after 6–12 months, at the latest 12 months after commission-
ing, irrespective of the level of exhaustion of the filter system. If the capacity of the filter cartridge
has already been exhausted (Chapter 7), it must be exchanged earlier.
Filter systems with a measuring and display unit
The filter cartridge must be replaced no later than 12 months after commissioning, irrespective of
the level of exhaustion of the filter system. If the capacity of the filter cartridge has already been
exhausted (Chapter 7), it must be replaced earlier.
If the cartridge is already exhausted, the capacity is indicated as being negative by flashing. No bars
are shown in the display.
If the monthly limit for the cartridge has been exceeded, this is indicated by the date flashing.
Resetting the display unit
To operate the display unit it has to be removed from the connecting fittings. Slide the display
housing up approx. 10 mm and pull off the display unit to the front. The display unit is operated
using a button on the back of the display unit.
If this button is pressed (> 10 seconds), the data
set on initial installation will be accepted again, and
the capacity, by-pass setting and input date are all
updated.
> 10 sec
Note: This automatically sets the monthly limit to 12 months.
Note: If no input is made within 30 seconds, the display will return to operating mode without
accepting amended parameters.
Insert display unit from front at a height of approx. 10 mm and slide down. The loops on the display
part must be inserted in the grooves on the measuring head.
29
EN
6.1 Removing the Filter Cartridge
Switch off power supply to the terminal device (remove plug).
Close inlet valve
7
at inlet hose
6
.
Place the flushing hose in a bucket and remove pressure from the filter system by opening the
flush valve. Catch the escaping water in a bucket.
Note: If the escaping water is more than 1 litre, the inlet valve
7
is not completely closed or is
blocked with scale.
Stand on the kick loops
12
with both feet while opening the pressure vessel
lid
3
by pressing the lock
15
and turning it anticlockwise as far as it will go.
Place the pressure vessel lid
3
vertically on both lid handles
20
.
Note: Do not turn the lid horizontally on its head.
Stand on the kick loops
12
with both feet while turning the pressure vessel
1
anticlockwise by
the mantle handles
16
as far as it will go.
Take your feet off the kick loops
12
and press the pressure vessel
1
down with both hands on
the mantle handles
16
.
Remove exhausted filter cartridge
2
from the pressure vessel
1
.
Place the exhausted filter cartridge
2
in the sink with the connection facing down to drain the
remaining water (> 5 min.).
Lock the exhausted filter cartridge
2
with the transport protective cap
18
of the new filter
cartridge and return in the original packaging to the appropriate BRITA address listed on the
back of the cover.
6.2 Inserting the Filter Cartridge
Check the connector seat of the filter cartridge O-ring
2
in the pressure vessel
lid
1
for dirt and damage.
Check that the O-ring seal of the filter cartridge
2
is correctly seated in the
groove and also check for dirt and damage.
Note: The cartridge seat has been lubricated with food-safe lubricant at the
factory.
Place the new filter cartridge
2
in the pressure vessel
1
.
Stand on the kick loops
12
with both feet, lift the pressure vessel
1
turning it
clockwise until the mantle handle
16
is over the kick loops
12
.
Stand on the kick loops
12
with both feet and place the pressure vessel
lid
3
on the pressure vessel
1
. The positioning of the arrow marking on the
lid handle
20
must line up with the “INSERT” groove.
Press the pressure vessel lid
3
down and turn clockwise until the lock
15
engages.
Switch on power supply to the terminal device (plug).
To flush and bleed the new filter cartridge
2
carry out the steps described under 5.3.
30
EN
7 Filter Capacity
7.1 Filter Capacity PURITY Quell ST
Carbonate Hardness
in °dH (°KH)
By-pass setting Filter capacity in litres
PURITY 450 PURITY 600 PURITY 1200
4 50% 8250 14100 25800
5 50% 8250 14100 25800
6 50% 8250 14100 25800
7 50% 7071 12086 22114
8 50% 6188 10575 19350
9 50% 5500 9400 17200
10 40% 4217 7207 13187
11 40% 3833 6552 1198 8
12 30% 3077 5260 9624
13 30% 2841 4855 8884
14 30% 2638 4508 8249
15 30% 2462 4208 7699
16 30% 2308 3945 7218
17 30% 2172 3713 6793
18 30% 2052 3506 6416
19 30% 1944 3322 6078
20 20% 1650 2820 5160
21 20% 1571 2686 4914
22 20% 1500 2564 4691
23 20% 1435 2452 4487
24 20% 1375 2350 4300
25 20% 1320 2256 4128
28 20% 1179 2014 3686
31 20% 1065 1819 3329
35 20% 943 1611 2949
By-pass and capacity table for combi ovens and conventional ovens
Depending on machine type, select by-pass setting 10% to achieve optimally treated water for the
combi oven/conventional oven. We will be happy to make specific recommendations.
Carbonate Hardness
in °dH (°KH)
By-pass setting Filter capacity in litres
PURITY 450 PURITY 600 PURITY 1200
4 10% 4991 8530 15607
5 10% 4991 8530 15607
6 10% 4991 8530 15607
7 10% 4278 7311 13378
8 10% 3743 6397 11706
9 10% 3327 5686 10405
10 10% 2995 5118 9364
11 10% 2722 4652 8513
12 10% 2496 4265 7804
13 10% 2304 3937 7203
14 10% 2139 3655 6689
15 10% 1996 3412 6243
16 10% 1872 3199 5853
17 10% 1762 3010 5508
18 10% 1664 2843 5202
19 10% 1576 2694 4929
20 10% 1497 2559 4682
21 10% 1426 2437 4459
22 10% 1361 2326 4257
23 10% 1302 2225 4071
24 10% 1248 2132 3902
31
EN
Carbonate Hardness
in °dH (°KH)
By-pass setting Filter capacity in litres
PURITY 450 PURITY 600 PURITY 1200
25 10% 1198 2047 3746
28 10% 1070 1828 3344
31 10% 966 1651 3021
35 10% 856 1462 2676
Note: The capacity limits refer to average utilisation of the terminal equipment, do not contain any
filter flushing and cleaning cycles and depend on local water quality, flow, mains pressure and flow
continuity.
8 Repair
Regularly check the filter system for leaks. Regularly check the hoses for kinks. Bent hoses must be
replaced.
The complete filter system must be replaced in rotation after a maximum of ten years.
The hoses must be replaced in rotation after a maximum of five years.
!
Caution: Prior to changing, read the Technical Data (Chapter 12) and the Operating and Safety
Information (Chapter 3).
Regularly clean the outside of the filter system with a soft, damp cloth.
!
Caution: Do not use any substances incompatible with the material (Chapter 3.4) or abrasive
cleaning materials.
9 Query Mode
The following data can be queried in the query mode:
Production data
Briefly press button 1 x (< 1 second), the following message appears.
Serial Appliance Number Battery Service Life
ID Level Production Year
Production year: Example 08 = 2008
Device number: consecutive
Battery useful life: Example 31/12/19 = The battery in the display unit will be exhausted on 31/12/19
and the complete filter system has reached its max. usage period.
32
EN
Total volume meter
Briefly press button 2 x (< 1 second), the following message appears.
00 level current data (today)
00 Indicator for current level Filter system size
Current dateTotal volume meter
The total volume meter is managed at this level; it counts up from 0 irrespective of the cartridge change.
Memory Call-Up
In the Memory Call-Up mode, the data of the last 4 filter cartridges used can be called up.
Briefly press button 3 x (<1 second) until the following message appears.
-1, -2, -3, -4 level – data of the cartridges used before the current one.
Carbonate hardness By-pass
Total meter reading when
changing the filter cartridge
Date of inserting the cartridge
alternating
Cartridge indicator Type
At the top left, the indicator for the filter cartridge (-1 for previous filter cartridge) is displayed alter-
nately with the carbonate hardness set and the hardness unit. At the top right, the filter system
size is displayed alternately with the by-pass setting (display 1 s indicator, 1 s carbonate hardness),
at the bottom left, the meter reading when changing the cartridge (-1) and at the bottom right,
the installation date of the cartridge.
Meaning: the filter cartridge most recently used was a PURITY 1200 cartridge, the filter cartridge
was inserted on 25/06/09 and operated up to a meter reading of 23166 litres.
The carbonate hardness set was 14°KH and the by-pass measured was 30%.
The same applies to the cartridge(-2), preceding filter cartridge and the other preceding filter
cartridges -3, -4.
Error Messages
Error level E1 indicates whether an error has occurred in blend detection.
E1 is activated as soon as the current bypass is not correctly identified.
The word Start is then displayed together with the date of occurrence.
alternating
As soon as the current bypass setting is identified correctly again, the error has ended and the Stop
date is added. At error level 01 the Stop and Start display alternates every second.
33
EN
Error level E2 indicates whether and from when until when an error has occurred at the outlet water
meter. Display is similar to level E1.
Program Overview
ID-Information

00 Current level

-1 History level 1

-2 History level 2

-3 History level 3

-4 History level 4

E1 Error inlet metre

E2 Error drainage metre
Filter system type and size 2 sec.

Type of hardness (unit)
and value 2 sec.

Monthly limit 2 sec.

RESET 2 sec.

Parameter acceptance
Operating mode
ParameterisationRetrieval mode
1 x button Press button 4 seconds
30 sec.no activity =
no Parameter acceptance
20 sec. no activity
Carbonate hardness • Ca-
pacity • By-pass • last filter
change date
10 Troubleshooting
10.1 No water flow
Cause: Water intake closed.
Troubleshooting: Open water intake on the upstream stop valve or inlet valve
7
on inlet hose
6
.
!
Caution: Installation and maintenance of the filter system may be carried out only by specialist staff.
10.2 No or low water flow in spite of open water intake
Cause: Mains pressure too low.
Troubleshooting: Check mains pressure.
If the fault continues in spite of adequate mains pressure, check the filter
system and filter cartridge and change if necessary.
!
Caution: Prior to changing, read the Technical Data (Chapter 12) and the
Operating and Safety Information (Chapter 3).
34
EN
10.3 Leak at Screwed Connections
Cause: Screwed connections not fitted correctly.
Troubleshooting: Check mains pressure. Check all screwed connections and mount according to
Chapter 4.
If the fault continues, exchange filter system.
!
Caution: Prior to changing, read the Technical Data (Chapter 12) and the
Operating and Safety Information (Chapter 3).
10.4 Leak after Filter Replacement
Cause: O-ring at the filter cartridge is not seated correctly.
Troubleshooting: Check correct seat of the O-ring (Chapter 6.2).
!
Caution: Prior to dismantling read the data (Chapter 12) and the Operating
and Safety Information (Chapter 3).
10.5 No Display Function
Cause: Battery drained.
Troubleshooting: Replace display unit (Order number see Chapter 13).
Note: When replacing the display unit, follow the enclosed manual.
10.6 Data on Display Flashing
Cause: Monthly limit expired or the remaining capacity of the filter cartridge is
exhausted (Chapter 5.2).
Troubleshooting: Replace filter cartridge (Chapter 6).
10.7 Bypass setting in the display does not agree with the setting of the bypass screw
(cf. 10.8/10.9)
Cause: Filter was not commissioned correctly.
Troubleshooting: Flush filter again (Chapter 5.4). Check data in the display after flushing
(Chapter 5.5).
10.8 Bypass setting in the display does not agree with the setting of the bypass screw
(cf. 10.7/10.8)
Cause: Valve strip of the by-pass setting not set correctly.
Troubleshooting: Flush filter system again and readjust bypass screw (Chapter 5.3)
11 Battery
The installed battery is designed for a service life of approx. 10 years. The battery and display unit
must not be burnt and must not be disposed of in domestic waste.
To remove the battery, please proceed as follows:
Remove the screw on the back of the display unit and open and remove the back
of the housing.
Disconnect the soldered contacts on the battery with side cutters and remove the battery
from the bracket.
Replace the back of the housing on the display unit and tighten the screw.
Dispose of the battery and display unit following
the local environmental guidelines for battery disposal.
35
EN
12 Technical Data
PURITY Quell ST filter system
PURITY 450 Quell ST PURITY 600 Quell ST PURITY 1200 Quell ST
MAE*
Distributor
head
MAE*
Distributor
head
MAE*
Distributor
head
Operating pressure 2 bar – max. 6.9 bar
Operating/water temperature 4°C to 30°C
Ambient tempera-
ture during
operation 10°C to 40°C
storage –20°C to 50°C
Flow rate with 1 bar pressure loss 300 l/h 350 l/h 300 l/h 350 l/h 300 l/h 350 l/h
Empty filter cartridge volume 3.9 l 5.8 l 10.9 l
Weight (dry/wet) 10 kg/12 kg 12 kg/15 kg 18 kg/24 kg
Dimensions 249 mm/222 mm/408 mm 249 mm/222 mm/520 mm 288 mm/255 mm/550 mm
Operating position Vertically or horizontally
Inlet connection G 1"
Outlet connection G 3/4"
* with ACS Technology
System Tested and Certified
by NSF International against
NSF/ANSI Standard 42 for the
reduction of Chlorine taste and
odor and against CSA B483.1.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170

Brita PURITY Quell ST User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI