DELTA DORE DRIVER 610, Driver 620 User manual

  • Hello! I am an AI chatbot trained to assist you with the DELTA DORE DRIVER 610 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Override
Time setting
Automatic mode
DRIVER 610 or 611
follows the programming.
DRIVER 620 or 621 follows the
programming in both zones.
Example: it is 15:30 and you would like to switch to
Comfort mode before the set time (17:00).
6h 8h
0h0h
17h15h30 23h
Override
Because of changes in standards and equipment, the characteristics given in
the text and the illustrations of this document are not binding unless confi rmed
by our services.
• Carefully read these instructions prior to use.
• Do not attempt to repair the unit yourself ;
after-sales service is available.
The following options are only available on the
DRIVER 611 or 621.
TYPHONE 500
When associated with the DRIVER 611 or 621, the
TYPHONE 500 allows you to control your heating
remotely by telephone.
MINOR 500
Regulates an underfl oor heating or radiant ceiling
heating system. In combination with the DRIVER 611
or 621, this unit is used to control the set points and
determine the room temperature measured by each
probe.
DRIVER
Description
NOTE : If the unit is confi gured for a daily program,
the days setting is not offered.
59
0
23
0
1 8
2
3
4
5
6
7
7
1
59
0
23
0
1 8
2
3
4
5
6
7
7
1
DRIVER
Selector
dial
position
Modifi cation
buttons
Selector dial
3
1
72:00
00:15
1
2
3
4
5
6
Timer mode
6h 8h
0h0h
17h11h 23h
13h30
This mode is used to select a mode for a given
time and for one zone only.
Example : comfort from 11h to 13h30.
3
1
72:00
00:15
1
2
3
4
5
6
3
1
72:00
00:15
1
2
3
4
5
6
3
1
72:00
00:15
1
2
3
4
5
6
3
1
72:00
00:15
1
2
3
4
5
6
During the AUTO, or modes, press the i button repeatedly to fi nd out:
Si option MINOR 500
Information button
365
1
1
2
3
Décompte S18 00:00
365
1
1
2
3
Décompte S18 00:00
1
365
1
1
2
3
Décompte S18 00:00
Absence mode
Shutdown mode
Absence mode
Timer mode
Automatic mode
Continuous mode
Time setting
Programming
Override
Information
button
Room
temperature
Current day
Time
Current
mode
Temperature
measured
by the sensor
Countdown
N° sensor
Indication of a sensor or
sensors on the installation
User guide
www.deltadore.com
DRIVER 610 - 620 - 611 - 621
Pilot wire programmer 1 or 2 zones
DELTA DORE - 08/18
Turn the selector dial to .
The days fl ash.
Press + or - to change the day, then press OK to
confi rm and continue on to the next setting.
To leave the “setting the time” mode, turn the
selector dial.
Turn the selector dial to AUTO.
In automatic mode, override is used to go from Comfort to Economy mode (or conversely) until the next program change.
Press the override button
of zone 1.
Current override on
zone 1
To cancel the current override, press the button once more.
At 17:00, the program will
return to its usual program.
Choice of the zone
proposed on the
DRIVER 620 or 621
(the other zone follows
the AUTO mode).
Confi rm.
Selection of the Comfort
or Economy mode.
Confi rm.
Adjustment of the duration
from 15 minutes to 72 hours
(in increments of 15 minutes).
Confi rmation and start of the
countdown
Return to AUTO
mode at the end of
the countdown
This mode lets you place your home under Frost
protection if you need to leave for several days.
Turn the selector dial to
.
Adjustment of the number of days (1 to 365).
Example : for a departure on 10th March and a return
on 18th March, program 8 days of absence.
Automatic operation will resume on 18 March at
midnight.
Confi rm and start the
calendar countdown.
Return to AUTO mode at
the end of the countdown
To cancel the current absence
mode, turn the selector dial.
If MINOR 500 option
1
2
2
2
Troubleshooting
Shutdown mode
This mode allows you to choose a continuous
mode for each of the zone.
DRIVER 610 or 611 DRIVER 620 or 621
Permanent mode
1
2
2
2
1
2
2
2
30°C
5°C
30°C
5°C
15°C
5°C
Consigne
1
Consigne
2
Consigne
Validation
Validation
Validation
3
MINOR 500 option : set point settings
30°C
5°C
30°C
5°C
15°C
5°C
Consigne
1
Consigne
2
Consigne
Validation
Validation
Validation
3
Prog
E.g. : Comfort from 6:00 to 8:00 and from 17:00 to 23:00.
Repeat actions for each
day of the week
6h 8h
0h0h
17h 23h
1
2
3 5
6
7
8
8
4
COPY
>3s
1
2
3 5
6
7
8
8
4
COPY
>3s
1
2
3 5
6
7
8
8
4
COPY
>3s
1
2
3 5
6
7
8
8
4
COPY
>3s
1
2
3 5
6
7
8
8
4
COPY
>3s
You can copy the program
on the next day
COMMENTS : Depending on the confi guration
made during installation, programming can be
weekly or daily. Likewise, this programming may
be done in increments of one hour, 30 minutes,
or 15minutes. To change these settings, refer to
the “installation guide”, or contact our customer
service department or your installer.
The purpose of this section is to help you quickly
solve the most common problems that you may
encounter with your product during use.
If you’re unsure, or if the problem persists or isn’t in
this list, contact our customer service department.
Nothing is displayed on the room unit screen.
There is no power supply.
Check your circuit breaker.
The i symbol fl ashes.
A fault has been detected in the system.
Press the button to consult the fault or faults.
The unit displays: dEF and a number.
There is a fault on the unit or the installation.
Contact your installer or our customer service
department.
The unit displays ---- instead of the temperature
measured by each MINOR 500 sensor.
There is a problem on at least one of the probes.
Contact your installer or our customer service
department.
The unit is in time setting mode.
There was a mains disruption that lasted more than
2 hours.
Set the time. All other settings have remained
unchanged.
When setting the time, there is no option to set
the day.
You are in daily programming.
To switch to weekly programming, refer to the
installation guide or contact your installer or our
customer service department.
The temperature displayed does not match the
temperature measured in the room (thermome-
ter).
Refer to the installation guide or contact your
installer or our customer service department.
The unit displays HEAT
Your underfl oor heating or radiant ceiling heating
system is in “gradual heating” mode.
If you want to know the number of days remaining,
press the i button.
The heating elements are in Frost Protection
mode
You are in programming mode, the absence mode
or time setting mode.
Turn the selector dial to select another mode.
Pb ---- is displayed on the screen.
Problem with the connection of a heating element.
Contact your installer or our customer service
department.
This mode shuts down your heating system.
Turn the selector dial to
.
This mode is used to modify the Comfort and
Shutdown set points of each sensor.
Turn the selector dial to
.
Repeat the operations for each probe.
When the last probe is set, you can set the Frost
Protection set point for all the zones.
To exit the mode, turn the selector dial to another
mode.
Turn the selector dial to PROG.
The default program is a Comfort period from 6:00 to 23:00.
1. Create your program
Programming starts on day 1 at midnight.
Press the
or buttons to create different Economy or Comfort periods.
2. Confi rm and copy the program
Press and hold the OK button for 3 seconds to confi rm the program you created and copy it to the next day.
3. Confi rm the program
Press the OK button to confi rm and continue on to the next day to program it separately.
Check your program
Press the
buttonrepeatedly to check the accuracy
of the Comfort and Shutdown periods you created.
Press the OK button to check the next day.
Programming zone 2)
The programming for zone 2 is available after pressing
(OK) of the day 7 of the zone 1.
Exiting the programming mode
Turn the selector dial to another mode.
or
Set point
Set point
Set point
Confi rm
Confi rm
Confi rm
/