Vega VEGAPULS Air 41 Operating instructions

Type
Operating instructions
Operating Instructions
Radar sensor for continuous level
measurement
VEGAPULS Air 41
Autarkic device with measured value trans-
mission via radio technology
Document ID: 64808
2
Contents
VEGAPULS Air 41 • Autarkic device with measured value transmission via radio technology
64808-EN-210216
Contents
1 About this document ............................................................................................................... 4
1.1 Function ........................................................................................................................... 4
1.2 Target group ..................................................................................................................... 4
1.3 Symbols used................................................................................................................... 4
2 For your safety ......................................................................................................................... 5
2.1 Authorised personnel ....................................................................................................... 5
2.2 Appropriate use ................................................................................................................ 5
2.3 Warning about incorrect use ............................................................................................. 5
2.4 General safety instructions ............................................................................................... 5
2.5 Lithium cells ..................................................................................................................... 6
2.6 Country of use .................................................................................................................. 6
3 Product description ................................................................................................................. 7
3.1 Conguration .................................................................................................................... 7
3.2 Principle of operation........................................................................................................ 8
3.3 Adjustment ....................................................................................................................... 9
3.4 Packaging, transport and storage ................................................................................... 10
4 Mounting ................................................................................................................................. 11
4.1 General instructions ....................................................................................................... 11
4.2 Mounting instructions ..................................................................................................... 11
5 Access protection .................................................................................................................. 16
5.1 Bluetooth radio interface ................................................................................................ 16
5.2 Protection of the parameterization .................................................................................. 16
5.3 Storing the codes in myVEGA ........................................................................................ 17
6 Operating modes, activate device ........................................................................................ 18
7 Setup with smartphone/tablet (Bluetooth) .......................................................................... 21
7.1 Preparations ................................................................................................................... 21
7.2 Connecting ..................................................................................................................... 21
7.3 Parameter adjustment .................................................................................................... 22
8 Setup with PC/notebook (Bluetooth) ................................................................................... 23
8.1 Preparations ................................................................................................................... 23
8.2 Connecting ..................................................................................................................... 23
8.3 Parameter adjustment .................................................................................................... 24
9 Menu overview ....................................................................................................................... 26
10 Diagnostics and servicing .................................................................................................... 29
10.1 Maintenance .................................................................................................................. 29
10.2 Rectify faults ................................................................................................................... 29
10.3 Status messages according to NE 107 .......................................................................... 30
10.4 Treatment of measurement errors .................................................................................. 32
10.5 Replacing lithium cells .................................................................................................... 36
10.6 Software update ............................................................................................................. 37
10.7 How to proceed if a repair is necessary .......................................................................... 37
11 Dismount................................................................................................................................. 38
11.1 Dismounting steps.......................................................................................................... 38
3
Contents
VEGAPULS Air 41 • Autarkic device with measured value transmission via radio technology
64808-EN-210216
11.2 Disposal ......................................................................................................................... 38
12 Certicatesandapprovals .................................................................................................... 39
12.1 Radio licenses ................................................................................................................ 39
12.2 EU conformity ................................................................................................................. 39
12.3 Environment management system ................................................................................. 39
13 Supplement ............................................................................................................................ 40
13.1 Technical data ................................................................................................................ 40
13.2 Radio networks LTE-M and NB-IoT ................................................................................ 43
13.3 Radio networks LoRaWAN - Data transmission ............................................................. 44
13.4 Dimensions .................................................................................................................... 46
13.5 Industrial property rights ................................................................................................. 47
13.6 Licensing information for open source software ............................................................. 47
13.7 Trademark ...................................................................................................................... 47
Safety instructions for Ex areas
TakenoteoftheExspecicsafetyinstructionsforExapplications.
These instructions are attached as documents to each instrument
with Ex approval and are part of the operating instructions.
Editing status: 2021-02-10
4
1 About this document
VEGAPULS Air 41 • Autarkic device with measured value transmission via radio technology
64808-EN-210216
1 About this document
1.1 Function
This instruction provides all the information you need for mounting,
connection and setup as well as important instructions for mainte-
nance,faultrectication,theexchangeofpartsandthesafetyofthe
user. Please read this information before putting the instrument into
operation and keep this manual accessible in the immediate vicinity
of the device.
1.2 Target group
This operating instructions manual is directed to trained personnel.
Thecontentsofthismanualmustbemadeavailabletothequalied
personnel and implemented.
1.3 Symbols used
Document ID
This symbol on the front page of this instruction refers to the Docu-
ment ID. By entering the Document ID on www.vega.com you will
reach the document download.
Information, note, tip: This symbol indicates helpful additional infor-
mation and tips for successful work.
Note: This symbol indicates notes to prevent failures, malfunctions,
damage to devices or plants.
Caution: Non-observance of the information marked with this symbol
may result in personal injury.
Warning: Non-observance of the information marked with this symbol
may result in serious or fatal personal injury.
Danger: Non-observance of the information marked with this symbol
results in serious or fatal personal injury.
Ex applications
This symbol indicates special instructions for Ex applications.
List
The dot set in front indicates a list with no implied sequence.
1 Sequence of actions
Numbers set in front indicate successive steps in a procedure.
Battery disposal
This symbol indicates special information about the disposal of bat-
teries and accumulators.
5
2 For your safety
VEGAPULS Air 41 • Autarkic device with measured value transmission via radio technology
64808-EN-210216
2 For your safety
2.1 Authorised personnel
All operations described in this documentation must be carried out
onlybytrained,qualiedpersonnelauthorisedbytheplantoperator.
During work on and with the device, the required personal protective
equipment must always be worn.
2.2 Appropriate use
The VEGAPULS Air 41 is an autarkic sensor for continuous level
measurement.
Youcannddetailedinformationabouttheareaofapplicationin
chapter " Product description".
Operational reliability is ensured only if the instrument is properly
usedaccordingtothespecicationsintheoperatinginstructions
manual as well as possible supplementary instructions.
2.3 Warning about incorrect use
Inappropriate or incorrect use of this product can give rise to applica-
tion-specichazards,e.g.vesseloverllthroughincorrectmounting
or adjustment. Damage to property and persons or environmental
contamination can result. Also, the protective characteristics of the
instrument can be impaired.
2.4 General safety instructions
This is a state-of-the-art instrument complying with all prevailing
regulations and directives. The instrument must only be operated in a
technicallyawlessandreliablecondition.Theoperatorisresponsi-
ble for the trouble-free operation of the instrument. When measuring
aggressive or corrosive media that can cause a dangerous situation
if the instrument malfunctions, the operator has to implement suitable
measures to make sure the instrument is functioning properly.
The safety instructions in this operating instructions manual, the na-
tional installation standards as well as the valid safety regulations and
accident prevention rules must be observed by the user.
For safety and warranty reasons, any invasive work on the device
beyond that described in the operating instructions manual may be
carried out only by personnel authorised by the manufacturer. Arbi-
traryconversionsormodicationsareexplicitlyforbidden.Forsafety
reasons,onlytheaccessoryspeciedbythemanufacturermustbe
used.
To avoid any danger, the safety approval markings and safety tips on
the device must also be observed.
The low transmitting power of the radar sensor as well as the inte-
grated LTE-NB1, LTE-CAT-M1 or LoRa radio module is far below
the internationally approved limits. No health impairments are to be
expected with intended use. The band range of the transmission
frequency can be found in chapter " Technical data".
6
2 For your safety
VEGAPULS Air 41 • Autarkic device with measured value transmission via radio technology
64808-EN-210216
2.5 Lithium cells
The power supply of the device is provided by integrated lithium cells
in the housing. If the device is used as intended with the lid closed
withinthetemperaturesandpressuresspeciedinthetechnicaldata,
it is thus adequately protected.
Note:
Pleaseobservethespecicsafetyinstructionsinthescopeofdeliv-
ery of the device.
2.6 Country of use
Selectionofthecountryofusedenescountry-specicsettingsfor
transmission into the mobile radio network or LoRaWan. It is impera-
tive to set the country of use with the respective operating tool in the
operating menu at the beginning of the setup (see chapter " Menu
Overview", " Main Menu", " Radio Transmission" .
Caution:
Operation of the device without selecting the country of use can lead
to malfunctions and constitutes a violation of the radio licensing regu-
lations of the respective country.
7
3 Product description
VEGAPULS Air 41 • Autarkic device with measured value transmission via radio technology
64808-EN-210216
3 Product description
3.1 Conguration
The scope of delivery encompasses:
Radar sensor
IntegratedidenticationcardforLTE(eSIM)(optional)
Magnet for activation
Information sheet " Documents and software" with:
Instrument serial number
QR code with link for direct scanning
Information sheet " PINs and Codes" with:
Bluetooth access code
IdentierforLoRaWANnetwork(DeviceEUI,ApplicationEUI,
AppKey)
Information sheet " Access protection" with:
Bluetooth access code
Network access code (authentication/encryption for mobile
radio)
Emergency Bluetooth unlock code
Emergency device code
IdentierforLoRaWANnetwork(DeviceEUI,ApplicationEUI,
AppKey)
The further scope of delivery encompasses:
Documentation
Safety instructions for lithium metal cell
Ifnecessary,furthercerticates
Note:
Optional instrument features are also described in this operating
instructions manual. The respective scope of delivery results from the
orderspecication.
This operating instructions manual applies to the following instrument
versions:
Hardware version from 1.0.0
Software version from 1.0.0
Scope of delivery
Scope of this operating
instructions
8
3 Product description
VEGAPULS Air 41 • Autarkic device with measured value transmission via radio technology
64808-EN-210216
4
2
3
1
5
Fig. 1: Components of the VEGAPULS Air 41 sensor - Example version with
thread G1½
1 Radar antenna
2 Processtting
3 Contact surface for NFC communication
4 Cover
5 Ventilation
Thetypelabelcontainsthemostimportantdataforidenticationand
use of the instrument.
VEGAPULS Air 41
AR - 222 226
MWP: -1...+2bar(-100...+200kPa)
Device EUI E8E8B7000040BA20
www.vega.com
s/n: 49789937
IP66/67
15m
D-77761 Schiltach
Made in Germany
PVDF
LTE-NB-IoT, LTE-Cat-M1, LoRa
1
5 6
7
2
3
4
Fig. 2: Layout of the type label (example)
1 Product code
2 Field for approvals
3 Wireless signal outputs, frequency bands
4 Device EUI LoRa
5 Technical data
6 Bluetooth access code
7 QR code for device documentation
3.2 Principle of operation
VEGAPULS Air 41 is an autarkic radar sensor with radio technology
for continuous level measurement on vessels and tanks.
The device is suitable for almost all liquids as well as for bulk solids.
Depending on the version, mounting is carried out via thread:
G1½
1½ NPT
R1½
The measurement is carried out through a suitable nozzle opening on
the vessel.
Constituent parts
Type label
Application area
Functional principle
9
3 Product description
VEGAPULS Air 41 • Autarkic device with measured value transmission via radio technology
64808-EN-210216
The instrument emits a continuous, frequency-modulated radar signal
throughitsantenna.Theemittedsignalisreectedbythemedium
andreceivedbytheantennaasanechowithmodiedfrequency.The
frequency change is proportional to the distance and is converted into
the level. The measured value is transmitted wirelessly as part of the
data transmission.
The measuring cycle described above is time-controlled via the
integrated clock. Outside of the measuring cycle, the device is in a
sleep mode.
Depending on the availability of the radio networks, the device trans-
mitsitsmeasuredvalueswirelesslytoanLTE-M(LTE-CAT-M1)orNB-
IoT(LTE-CAT-NB1)mobileradiooraplant-sideLoRaWANnetwork.
The transmission or evaluation is carried out via an Asset Manage-
ment System, e.g. VEGA Inventory System.
The device is supplied with energy by integrated, exchangeable pri-
mary cells. The lithium cell used for this purpose is a compact storage
device high cell voltage and capacity for a long service life.
3.3 Adjustment
The device is activated contactlessly from outside:
Via magnet
By NFC technology via smartphone/tablet with VEGA Tools app
The device has an integrated Bluetooth module, can be operated
wirelessly using standard operating tools:
Smartphone/tablet(iOSorAndroidoperatingsystem)
PC/notebook with Bluetooth USB adapter (Windows operating
system)
1
3
2
Fig. 3: Wireless connection to standard operating devices via Bluetooth
1 Sensor
2 Smartphone/Tablet
3 PC/Notebook
Measured value transmis-
sion
Voltage supply
Activation
Adjustment
10
3 Product description
VEGAPULS Air 41 • Autarkic device with measured value transmission via radio technology
64808-EN-210216
3.4 Packaging, transport and storage
Your instrument was protected by packaging during transport. Its
capacity to handle normal loads during transport is assured by a test
based on ISO 4180.
The packaging consists of environment-friendly, recyclable card-
board. For special versions, PE foam or PE foil is also used. Dispose
of the packaging material via specialised recycling companies.
Transport must be carried out in due consideration of the notes on the
transport packaging. Nonobservance of these instructions can cause
damage to the device.
The delivery must be checked for completeness and possible transit
damage immediately at receipt. Ascertained transit damage or con-
cealed defects must be appropriately dealt with.
Up to the time of installation, the packages must be left closed and
stored according to the orientation and storage markings on the
outside.
Unless otherwise indicated, the packages must be stored only under
the following conditions:
Not in the open
Dry and dust free
Not exposed to corrosive media
Protected against solar radiation
Avoiding mechanical shock and vibration
Storage and transport temperature see chapter " Supplement -
Technical data - Ambient conditions"
Relative humidity 20 … 85 %
Packaging
Transport
Transport inspection
Storage
Storage and transport
temperature
11
4 Mounting
VEGAPULS Air 41 • Autarkic device with measured value transmission via radio technology
64808-EN-210216
4 Mounting
4.1 General instructions
The instrument is suitable for standard and extended ambient condi-
tions acc. to DIN/EN/IEC/ANSI/ISA/UL/CSA 61010-1. It can be used
indoors as well as outdoors.
Note:
For safety reasons, the instrument must only be operated within the
permissibleprocessconditions.Youcannddetailedinformationon
the process conditions in chapter " Technical data" of the operating
instructions or on the type label.
Hence make sure before mounting that all parts of the instrument ex-
posed to the process are suitable for the existing process conditions.
The device measures the level only when aligned downwards.
To ensure this, the device has a GPS position sensor and an inde-
pendent position sensor.
Note:
If the container is aligned horizontally (e.g. tilted during transport of a
mobilecontainer)nomeasurementistaken.
4.2 Mounting instructions
Radar sensors for level measurement emit electromagnetic waves.
The polarization is the direction of the electrical component of these
waves.
The position of the polarisation is in the middle of the type label on the
instrument.
1
Fig. 4: Position of the polarisation
1 Middle of the type label
Note:
When the device is rotated, the direction of polarization changes and
hencetheinuenceofthefalseechoonthemeasuredvalue.Please
keep this in mind when mounting or making changes later.
When mounting the device, keep a distance of at least 200 mm
(7.874in)fromthevesselwall.Ifthedeviceisinstalledinthecenter
of dished or round vessel tops, multiple echoes can arise. However,
these can be suppressed by an appropriate adjustment (see chapter
" Setup").
If you cannot maintain this distance, you should carry out a false
signal suppression during setup. This applies particularly if buildup on
Ambient conditions
Process conditions
Transport, alignment,
position detection
Polarisation
Installation position
12
4 Mounting
VEGAPULS Air 41 • Autarkic device with measured value transmission via radio technology
64808-EN-210216
the vessel wall is expected. In such cases, we recommend repeating
the false signal suppression at a later date with existing buildup.
> 200 mm
(7.87
")
Fig. 5: Mounting of the radar sensor on round vessel tops
In vessels with conical bottom it can be advantageous to mount the
device in the centre of the vessel, as measurement is then possible
down to the bottom.
Fig. 6: Mounting of the radar sensor on vessels with conical bottom
The sealing surface at the bottom of the hexagon is the beginning of
the measuring range and at the same time the reference plane for the
min./max. adjustment, see the following graphic:
1
Fig. 7: Reference plane
1 Reference plane
For nozzle mounting, the nozzle should be as short as possible and
itsendrounded.Thisreducesfalsereectionsfromthenozzle.
Theantennaedgeshouldprotrudeatleast5mm(0.2in)outofthe
nozzle.
Reference plane
Nozzle
13
4 Mounting
VEGAPULS Air 41 • Autarkic device with measured value transmission via radio technology
64808-EN-210216
≥ 5 mm
(
0.20
")
Fig. 8: Recommended socket mounting of VEGAPULS Air 41
Ifthereectivepropertiesofthemediumaregood,youcanmount
VEGAPULS Air 41 on sockets longer than the antenna. The socket
end should be smooth and burr-free, if possible also rounded.
Note:
When mounting on longer nozzles, we recommend carrying out a
false signal suppression (see chapter " Parameter adjustment").
Youwillndrecommendedvaluesforsocketheightsinthefollowing
illustration or the table. The values come from typical applications.
Deviating from the proposed dimensions, also longer sockets are
possible, however the local conditions must be taken into account.
d
h
Fig. 9: Socket mounting with deviating socket dimensions
Socket diameter d Socket length h
80 mm 3" ≤300mm ≤11.8in
100 mm 4" ≤400mm ≤15.8in
150 mm 6" ≤600mm ≤23.6in
In liquids, direct the device as perpendicular as possible to the me-
dium surface to achieve optimum measurement results.
Fig. 10: Alignment in liquids
In order to measure as much of the vessel volume as possible, the
device should be aligned so that the radar signal reaches the lowest
level in the vessel. In a cylindrical silo with conical outlet, the sensor is
mounted anywhere from one third to one half of the vessel radius from
theoutsidewall(seefollowingdrawing).
Alignment - Liquids
Orientation - Bulk solids
14
4 Mounting
VEGAPULS Air 41 • Autarkic device with measured value transmission via radio technology
64808-EN-210216
r
rr...
/
1
3
/
1
2
Fig. 11: Mounting position and orientation
Due to optimum socket design, the device can be easily aligned to
the vessel centre. The necessary angle of inclination depends on the
vessel dimensions. It can be easily checked with a suitable bubble
tube or mechanic's level on the sensor.
d
a
α
Fig. 12: Proposal for installation after orientation VEGAPULS Air 41
The following table shows the necessary angle of inclination. It
depends on the measuring distance and the distance "a" between
vessel centre and installation position.
15
4 Mounting
VEGAPULS Air 41 • Autarkic device with measured value transmission via radio technology
64808-EN-210216
Distance d
(m)
10°
2 0.1 0.1 0.2 0.3 0.4
4 0.1 0.3 0.4 0.6 0.7
6 0.2 0.4 0.6 0.8 1.1
8 0.3 0.6 0.8 1.1 1.4
10 0.3 0.7 1.1 1.4 1.8
15 0.5 1 1.6 2.1 2.6
Example:
In a vessel 10 m high, the installation position of the sensor is 0.7 m
from the vessel centre.
The necessary angle of inclination of 4° can be read out from this
table.
16
5 Access protection
VEGAPULS Air 41 • Autarkic device with measured value transmission via radio technology
64808-EN-210216
5 Access protection
5.1 Bluetooth radio interface
Devices with a Bluetooth radio interface are protected against un-
wanted access from outside. This means that only authorized persons
can receive measured and status values and change device settings
via this interface.
A Bluetooth access code is required to establish Bluetooth com-
municationviatheadjustmenttool(smartphone/tablet/notebook).
This code must be entered once when Bluetooth communication is
establishedforthersttimeintheadjustmenttool.Itisthenstoredin
the adjustment tool and does not have to be entered again.
The Bluetooth access code is individual for each device. It is printed
on the device housing and is also supplied with the device in the infor-
mation sheet " PINs and Codes". It can be changed by the user after
therstconnectionhasbeenestablished.IftheBluetoothaccess
code has not been entered correctly, a new entry can only be made
after a waiting period has elapsed. The waiting time increases with
each additional incorrect entry.
The emergency Bluetooth access code enables Bluetooth communi-
cation to be established in the event that the Bluetooth access code
is no longer known. It can't be changed. The emergency Bluetooth
access code can be found in information sheet " Access protection".
If this document is lost, the emergency Bluetooth access code can
be retrieved from your personal contact person after legitimation.
The storage and transmission of Bluetooth access codes is always
encrypted(SHA256algorithm).
5.2 Protection of the parameterization
Thesettings(parameters)ofthedevicecanbeprotectedagainstun-
wanted changes. The parameter protection is deactivated on delivery,
all settings can be made.
To protect the parameterization, the device can be locked by the user
with the aid of a freely selectable device code. The settings (param-
eters)canthenonlybereadout,butnotchanged.Thedevicecode
is also stored in the adjustment tool. However, unlike the Bluetooth
access code, it must be re-entered for each unlock. When using the
adjustment app or DTM, the stored device code is then suggested to
the user for unlocking.
The emergency device code allows unlocking the device in case the
device code is no longer known. It can't be changed. The emergency
device code can also be found on the supplied information sheet " Ac-
cess protection". If this document is lost, the emergency device code
can be retrieved from your personal contact person after legitimation.
The storage and transmission of the device codes is always encrypt-
ed(SHA256algorithm).
Bluetooth access code
Emergency Bluetooth
unlock code
Device code
Emergency device code
17
5 Access protection
VEGAPULS Air 41 • Autarkic device with measured value transmission via radio technology
64808-EN-210216
5.3 Storing the codes in myVEGA
If the user has a " myVEGA" account, then the Bluetooth access code
as well as the device code are additionally stored in his account under
" PINs and Codes".Thisgreatlysimpliestheuseofadditionaladjust-
ment tools, as all Bluetooth access and device codes are automati-
cally synchronized when connected to the " myVEGA" account
18
6 Operating modes, activate device
VEGAPULS Air 41 • Autarkic device with measured value transmission via radio technology
64808-EN-210216
6 Operating modes, activate device
The VEGAPULS Air 41 has the following operating modes that can be
set via operating tools:
Deactivated
Activated
Information:
On delivery, the device is in the deactivated state and must be acti-
vated for operation using a smartphone or magnet.
The activation and function of these operating modes is described
below.
In the deactivated state, the device is not woken up by the integrated
clock despite a set measuring interval.
The fact that the sensor does not wake up and does not carry out
measurement cycles or communication means that the lithium cell is
not unnecessarily discharged. In this state, longer storage is possible
until the device is used.
The following options are available for activating the device from the
deactivated delivery status:
By smartphone with VEGA Tools app via NFC
Via magnet
By smartphone
Proceed as follows for activation by NFC:
1. Start VEGA Tools app on smartphone
2. Activate NFC communication
3. Hold the adjustment tool tightly on the instrument side with the
lettering " VEGA"
1
2
Fig. 13: Activate the sensor
1 Adjustment tool, e.g. smartphone
2 Contact surface for NFC communication
Theappconrmssuccessfulactivationandthedeviceisreadyfora
radio connection for 60 seconds.
Via magnet
Proceed as follows for activation by magnet:
Operating modes
Deactivated
Activate
19
6 Operating modes, activate device
VEGAPULS Air 41 • Autarkic device with measured value transmission via radio technology
64808-EN-210216
→
Hold the magnet close to the side of the device and move it
towards the housing cover
ACTIVATION
Magnet
ACTIVATION
Magnet
1
2
Fig. 14: Activate the sensor
1 Radar sensor
2 Contact surface for magnet
3 Magnet
The device is ready for a radio connection for 60 s.
Note:
If no Bluetooth connection is established within these 60 seconds,
the device automatically returns to sleep mode. If an established
Bluetooth connection is interrupted, a new connection is possible for
a further 10 seconds, etc.
When activated, the device is woken up by the integrated clock and
carriesoutameasurementcycle(measurementandtransmission).It
then automatically switches to an energy-saving sleep mode.
Themeasuringintervalrunsonthebasisofthefactorypre-congura-
tionorauser-setconguration.
Note:
In sleep mode, it is not possible to connect to the device via
Bluetooth.
The instrument can be deactivated via the VEGA Tools app or the
DTM, e.g. for temporary shutdown. The device is reactivated as
described above.
To transmit the measured values to the cloud, the device requires ac-
cess to mobile network or a LoRaWAN network at the installation site,
depending on the version. If no corresponding network is available, a
LoRaWAN gateway must be installed.
Note:
Ensure free access to the radio network. The device must not be cov-
ered by metal - especially at medium height - or even enclosed.
Note:
Simultaneous operation of LTE-M or LTE-IoT and LoRaWAN is not
supported.
The following measured values or data are transmitted:
Activated
Deactivate
Communication
20
6 Operating modes, activate device
VEGAPULS Air 41 • Autarkic device with measured value transmission via radio technology
64808-EN-210216
Distance from the medium surface
Electronics temperature
Geographical position determined by GNSS
Installation position
Remaining life of Lithium cells
Device status
The geographical position is determined by an integrated GNSS
sensor via navigation satellites. It is optionally available with the LTE-
M/NB-IoTversionofthedeviceandcanbeswitchedon/oviathe
VEGA Tools app or PACTware/DTM.
1)
If position determination is activated, it is carried out once after tilting
the device by 20°. If no satellite signal has been found and no position
determined after 180 s, the procedure is aborted.
Information:
If the sensor is tilted by more than 20°, the device goes into fault
mode; no more radar measurements are made.
Position determination
1)
No position determination in LoRa mode
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Vega VEGAPULS Air 41 Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI