Cisco UCS-MR-1X082RY-A= Datasheet

Category
Memory modules
Type
Datasheet

This manual is also suitable for

CISCO SYSTEMS PUBLICATION HISTORY
170 W
EST TASMAN DR.
S
AN JOSE, CA, 95134 REV B.1 NOVEMBER 8, 2012
WWW.CISCO.COM
Cisco UCS C240 M3
High-Density
Rack Server (Small Form
Factor Disk Drive Model)
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
2
CONTENTS
OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Chassis Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . . 6
CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
STEP 1 VERIFY SERVER SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
STEP 2 SELECT CPU(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
STEP 3 SELECT MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
STEP 4 SELECT RAID CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
STEP 5 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs) . . . . . . . . . . . . . 23
STEP 6 SELECT PCIe OPTION CARD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . 28
STEP 8 ORDER POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
STEP 9 SELECT AC POWER CORD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM . . . . . . . . . . . . . . . . . 35
STEP 11 ORDER A TRUSTED PLATFORM MODULE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL) . . . . . . . . . . . . . . . 37
STEP 13 ORDER OPTIONAL USB 2.0 DRIVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
STEP 14 SELECT OPERATING SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
STEP 15 SELECT OPERATING SYSTEM MEDIA KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
STEP 16 SELECT OPTIONAL VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . . . . . . . . . . . 42
STEP 17 SELECT SERVICE and SUPPORT LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
OPTIONAL STEP - ORDER RACK(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
OPTIONAL STEP - ORDER PDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
CHASSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
CPUs and DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Physical Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Memory Population Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Recommended Memory Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Supported DIMM Populations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Low-Voltage DIMM Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
RAID Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
RACKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
KVM CABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
Motherboard USB and SD Ports, and RAID Card Backup Locations . . . . . . . . . . . . . . . . . . .62
TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Compliance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
OVERVIEW
3
OVERVIEW
The UCS C240 M3 rack server is designed for both performance and expandability over a wide range of
storage-intensive infrastructure workloads from big data to collaboration.
Building on the success of the Cisco UCS C210 M2 rack server, the enterprise-class UCS C240 M3 server
further extends the capabilities of Cisco’s Unified Computing System portfolio in a 2U form factor with the
addition of the Intel® E5-2600 series processor family CPUs that deliver the best combination of
performance, flexibility and efficiency gains. In addition, the UCS C240 M3 server provides 24 DIMM slots, up
to 24 drives and 4 x 1 GbE LOM to provide outstanding levels of internal memory and storage expandability
along with exceptional performance.
Figure 1 Cisco UCS C240 M3 High-Density SFF Rack Server
Front View
Rear View
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
4
DETAILED VIEWS
DETAILED VIEWS
Chassis Front View
Figure 2 shows the Cisco UCS C240 M3 High-Density SFF Rack Server.
Figure 2 Chassis Front View
For more information about the KVM cable connection, see KVM CABLE, page 61.
1 KVM connector
(used with KVM cable that provides two USB,
one VGA, and one serial connector)
6 Temperature status LED
2 Asset tag (serial number) 7 Fan status LED
3 Drives (up to 24 2.5-inch hot-swappable
drives)
8 System status LED
4 Network link activity LED 9 Identification button/LED
5 Power supply status LED 10 Power button/power status LED
HDD 1
HDD 2
HDD 3
HDD 4
HDD 5
HDD 6
HDD 7
HDD 8
HDD 9
HDD 10
HDD 11
HDD 12
HDD 13
HDD 14
HDD 15
HDD 16
HDD 17
HDD 18
HDD 19
HDD 20
HDD 21
HDD 22
HDD 23
HDD 24
331807
4
5
6
7
8
10
9
3
21
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
DETAILED VIEWS
5
Chassis Rear View
Figure 3 shows the external features of the rear panel.
Figure 3 Chassis Rear View
1 Power supplies (up to two) 7 One RJ-45 10/100/1000 Ethernet dedicated
management port
2 Standard-profile PCIe slot on riser 2:
PCIe 5—full-height, 3/4-length, x16 lane
width, x24 connector, GPU ready
8 USB 2.0 port
3 Low-profile PCIe slot on riser:
PCIe 4—half-height, 3/4-length, x8 lane
width, x16 connector, no NCSI
2
support
9 Quad 1-Gb Ethernet ports
(LAN1, LAN2, LAN3, and LAN4)
4 VGA video connector 10 Standard-profile PCIe slots on riser 1(three):
PCIe 1—full-height, half-length, x8 lane
width, x8 connector
PCIe 2—full-height, half-length, x16 lane
width, x24 connector (supports Cisco Virtual
Interface Card (VIC))
PCIe 3—full-height, half-length, x8 lane
width, x16 connector
5 Serial connector (RJ-45) 11 Rear Identification button/LED
6 USB 2.0 port -
PSU1 PSU2
PCIe 1
PCIe 2
PCIe 3
PCIe 4
PCIe 5
4 98 107 1165
2 3
331826
1
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
6
BASE SERVER STANDARD CAPABILITIES and FEATURES
BASE SERVER STANDARD CAPABILITIES and FEATURES
Table 1 lists the capabilities and features of the base server. Details about how to configure the server for
a particular feature or capability (for example, number of processors, disk drives, or amount of memory)
are provided in
CONFIGURING the SERVER, page 9.
Table 1 Capabilities and Features
Capability/Feature Description
Chassis Two rack unit (2RU) chassis
CPU One or two Intel® E5-2600 series processor family CPUs
Chipset Intel® C600 series chipset
Memory 24 slots for registered ECC DIMMs (RDIMMs) or load-reduced DIMMs (LRDIMMs)
NIC Embedded dual-port Intel i350 PCIe-based Gigabit Ethernet controller,
supporting the following:
Pre-Execution Boot (PXE boot)
iSCSI boot
Expansion slots Five PCIe slots (on two riser cards)
Riser 1 (PCIe slots 1, 2, and 3):
One x16 PCIe Gen3 Slot, x24 extended connector, full-height,
half-length
Two x8 PCIe Gen3 Slots Full Height, x16 connector, half-length
Riser 2 (PCIe slots 4 and 5):
One x16 PCIe Gen3 Slot, Full Height, (225W GPU Ready), x24
connector, three-quarter length
One x8 PCIe Gen3 Slot, half-height, x16 connector, half-length
Internal storage devices Drives are installed into front-panel drive bays that provide hot-pluggable
access.
Small Form Factor (SFF) drives. The server can hold up to:
24 2.5 inch (63.5 mm) SAS or SATA hard drives (HDDs) or solid state
drives (SSDs) (24-drive backplane with SAS expander configuration)
16 2.5 inch (63.5 mm) SAS or SATA HDDs or SSDs (16-drive backplane
with no SAS expander configuration)
The server also contains one internal USB 2.0 port on the motherboard
that you can use with a USB thumb drive for additional storage
Cisco Flexible Flash
drives
The server supports one internal Cisco Flexible Flash drive (SD card).
The SD card is pre-loaded with four virtual drives. The four virtual
drives contain, respectively, the Cisco Server Configuration Utility, the
Cisco Host Upgrade Utility, the Cisco C-Series server drivers set, and a
blank virtual drive on which you can install an OS or a hypervisor.
4 GB is available for general use
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
BASE SERVER STANDARD CAPABILITIES and FEATURES
7
Storage controller Embedded RAID (3 Gbs)
• Embedded SATA-only RAID controller, supporting up to four SATA-only
drives (RAID 0, 1, 10)
ROM5 RAID upgrade, supporting up to eight SAS/SATA HDDs or SSDs
(RAID 0, 1, 10). SAS and SATA drives can be mixed.
ROM55 RAID upgrade, supporting up to eight SAS/SATA HDDs or SSDs
(RAID 0, 1, 10, 5). SAS and SATA drives can be mixed.
Note that embedded RAID options can be supported only with the version of
the C240 M3 SFF server that has been configured with a 16-drive backplane
with no SAS expander.
Mezzanine Cards (6 Gbs) - two versions
• Cisco UCSC RAID SAS 2008M-8i Mezzanine Card supports up to 8 or 16
SAS/SATA drives (depending on the backplane used) supporting RAID
0, 1, 10, 5, and 50. SAS and SATA drives can be mixed. This card has a
product ID (PID) of UCSC-RAID-11-C240.
• Cisco UCSC RAID SAS 2008M-8i Mezzanine Card supports up to 8 or 16
SAS/SATA drives (depending on the backplane used) supporting RAID
0, 1, and 10. SAS and SATA drives can be mixed. This card has a
product ID (PID) of UCSC-RAID-MZ-240.
Note that mezzanine cards are used as follows:
A mezzanine card in a 16-drive backplane system with no SAS
expander can support up to 8 drives.
A mezzanine card in a 24-drive backplane system with SAS expander
can support up to 16 drives.
Plug-in PCIe Cards (6 Gbs)
LSI MegaRAID SAS 9266-8i 8-port plug-in PCIe RAID RAID controller
card (occupies a half-height PCIe slot) supporting RAID levels 0, 1,
10, 5, 6, 50, 60 and up to 24 internal SAS or SATA drives (with
24-drive backplane with SAS expander). SAS and SATA drives can be
mixed.
LSI MegaRAID SAS 9266CV-8i RAID 8-port PCIe plug-in RAID controller
card, supporting RAID 0, 1, 10, 5, 6, 50, and 60 and up to up to 24
internal SAS or SATA drives (with 24-drive backplane with SAS
expander). SAS and SATA drives can be mixed.
Video The Emulex Pilot 3 Integrated Baseboard Management Controller provides
video:
Matrox G200e video controller
Integrated 2D graphics core with hardware acceleration
Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at
60 Hz
24-bit color depth for all resolutions less than 1600x1200
Up to 256 MB video memory
Capability/Feature Description
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
8
BASE SERVER STANDARD CAPABILITIES and FEATURES
Interfaces Rear panel
One RJ-45 10/100/1000 Ethernet management port, using Cisco
Integrated Management Controller (CIMC) firmware
Four 1-Gb LOM ports
One RJ45 serial port connector
Two USB 2.0 port connectors
One DB15 VGA connector
Various PCIe card ports (dependent on which cards are installed)
Converged Network Adapter (CNA) ports
Network Interface Card (NIC) ports
Host Bus Adapter (HBA) ports
Front panel
One KVM console connector (supplies two USB 2.0, one VGA, and one
serial connector)
Front Panel A front panel controller provides status indications and control buttons
Power subsystem One power supply is required (either 650 W or 1200 W). An additional power
supply may be ordered to provide 1+1 redundancy. The power supplies must
match in a redundant power supply configuration.
Fans Chassis:
Six hot-swappable fans for front-to-rear cooling
Power supply:
Each power supply is equipped with a fan.
Integrated management
processor
Cisco Integrated Management Controller (CIMC) firmware.
Depending on your CIMC settings, the CIMC can be accessed through the 1-Gb
Ethernet dedicated management port, the 1-Gb Ethernet LOM ports, or a
Cisco P81E or Cisco 1225 virtual interface card (VIC).
Capability/Feature Description
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
9
CONFIGURING the SERVER
Follow these steps to configure the Cisco UCS C240 M3 High-Density SFF Rack Server:
STEP 1 VERIFY SERVER SKU, page 10
STEP 2 SELECT CPU(s), page 11
STEP 3 SELECT MEMORY, page 13
STEP 4 SELECT RAID CONFIGURATION, page 18
STEP 5 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs), page 23
STEP 6 SELECT PCIe OPTION CARD(s), page 25
STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES, page 28
STEP 8 ORDER POWER SUPPLY, page 31
STEP 9 SELECT AC POWER CORD(s), page 32
STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM, page 35
STEP 11 ORDER A TRUSTED PLATFORM MODULE, page 36
STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL), page 37
STEP 13 ORDER OPTIONAL USB 2.0 DRIVE, page 38
STEP 14 SELECT OPERATING SYSTEM, page 39
STEP 15 SELECT OPERATING SYSTEM MEDIA KIT, page 41
STEP 16 SELECT OPTIONAL VALUE-ADDED SOFTWARE, page 42
STEP 17 SELECT SERVICE and SUPPORT LEVEL, page 43
OPTIONAL STEP - ORDER RACK(s), page 47
OPTIONAL STEP - ORDER PDU, page 48
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
10
CONFIGURING the SERVER
STEP 1 VERIFY SERVER SKU
Select one server product ID (PID) from Table 2.
The Cisco C240 M3 server:
Includes one tool-less rail kit, adjustable from 26 inches (660 mm) to 36 inches (914 mm)
Includes either a 24- or 16-drive backplane.
Does not include power supply, CPU, memory, hard disk drives (HDDs), solid-state drives
(SSDs), SD card, or plug-in PCIe cards.
Table 2 PID of the C240 M3 High-Density SFF Rack Base Server
Product ID (PID) Description
UCSC-C240-M3S2 UCS C240 M3 SFF, no CPU, memory, HDD, power supply, or PCIe, with rail kit,
16-drive backplane, and no SAS expander
UCSC-C240-M3S UCS C240 M3 SFF, no CPU, memory, HDD, power supply, or PCIe, with rail kit,
24-drive backplane, and SAS expander
NOTE: Embedded RAID can only be used with systems implementing a
16-drive backplane that contains no SAS expander.
Mezzanine cards can be used as follows:
A mezzanine card in a 16-drive backplane system with no SAS
expander can support up to 8 drives.
A mezzanine card in a 24-drive backplane system with SAS expander
can support up to 16 drives.
NOTE: Use the steps on the following pages to configure the server with
the components that you want to include.
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
11
STEP 2 SELECT CPU(s)
The standard CPU features are:
Intel E5-2600 series processor family CPU
Intel® C600 series chipset
Cache size of 10, 15, or 20 MB
Select CPUs
The available CPUs are listed in Table 3.
Table 3 Available Intel CPUs: E5-2600 Series Processor Family CPUs
Product ID (PID)
Intel
Number
Clock
Freq
(GHz)
Power
(W)
Cache
Size
(MB)
Cores QPI
Highest DDR3
DIMM Clock
Support (MHz)
1
Notes . . .
1. If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be
clocked at the lowest common denominator of CPU clock and DIMM clock.
UCS-CPU-E5-2690 E5-2690 2.90 135 20 8 8 GT/s 1600
UCS-CPU-E5-2680 E5-2680 2.70 130 20 8 8 GT/s 1600
UCS-CPU-E5-2670 E5-2670 2.60 115 20 8 8 GT/s 1600
UCS-CPU-E5-2667 E5-2667 2.90 130 15 6 8 GT/s 1600
UCS-CPU-E5-2665 E5-2665 2.40 115 20 8 8 GT/s 1600
UCS-CPU-E5-2660 E5-2660 2.20 95 20 8 8 GT/s 1600
UCS-CPU-E5-2650 E5-2650 2.00 95 20 8 8 GT/s 1600
UCS-CPU-E5-2650L E5-2650L 1.80 70 20 8 8 GT/s 1600
UCS-CPU-E5-2643 E5-2643 3.30 130 10 4 8 GT/s 1600
UCS-CPU-E5-2640 E5-2640 2.50 95 15 6 7.2 GT/s 1333
UCS-CPU-E5-2630 E5-2630 2.30 95 15 6 7.2 GT/s 1333
UCS-CPU-E5-2630L E5-2630L 2.00 60 15 6 7.2 GT/s 1333
UCS-CPU-E5-2620 E5-2620 2.00 95 15 6 7.2 GT/s 1333
UCS-CPU-E5-2609 E5-2609 2.40 80 10 4 6.4 GT/s 1066
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
12
CONFIGURING the SERVER
Approved Configurations
(1) 1-CPU configurations:
Select any one CPU listed in Table 3.
(2) 2-CPU Configurations:
Select two identical CPUs from any one of the rows of Table 3 on page 11.
Caveats
You can select either one processor or two identical processors.
For optimal performance, select DIMMs with the highest clock speed for a given processor
(see
Table 3 on page 11). If you select DIMMs whose speeds are lower or higher than that
shown in the tables, suboptimal performance will result.
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
13
STEP 3 SELECT MEMORY
The standard memory features are:
DIMMs
Clock speed: 1333 or 1600 MHz
Ranks per DIMM: 1, 2, or 4
Operational voltage: dual voltage capable (1.5 V or 1.35 V)
Registered ECC DDR3 DIMMS (RDIMMS) or load-reduced DIMMS (LRDIMMs)
Memory is organized with four memory channels per CPU, with up to three DIMMs per
channel, as shown in
Figure 4.
Figure 4 C240 M3 SFF Memory Organization
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
14
CONFIGURING the SERVER
Select DIMMs and Memory Mirroring
Select the memory configuration and whether or not you want the memory mirroring option.
The available memory DIMMs and mirroring option are listed in
Table 4.
Approved Configurations
(1) 1-CPU configuration without memory mirroring:
Select from 1 to 12 DIMMs. Refer to Memory Population Rules, page 52, for more detailed
information.
(2) 1-CPU configuration with memory mirroring:
NOTE: When memory mirroring is enabled, the memory subsystem simultaneously
writes identical data to two channels. If a memory read from one of the channels
returns incorrect data due to an uncorrectable memory error, the system
automatically retrieves the data from the other channel. A transient or soft error in
one channel does not affect the mirrored data, and operation continues unless there
is a simultaneous error in exactly the same location on a DIMM and its mirrored
DIMM. Memory mirroring reduces the amount of memory available to the operating
system by 50% because only one of the two populated channels provides data.
Table 4 Available DDR3 DIMMs
Product ID (PID) PID Description Voltage
Ranks/
DIMM
DIMM Options
UCS-ML-1X324RY-A 32GB DDR3-1600-MHz LR DIMM/PC3-12800/quad rank/x4/1.35v 1.35 V 4
UCS-MR-1X162RY-A 16GB DDR3-1600-MHz RDIMM/PC3-12800/dual rank/x4/1.35v 1.35 V 2
UCS-MR-1X162RX-A 16GB DDR3-1333-MHz RDIMM/PC3-10600/dual rank/x4/1.35v 1.35 V 2
UCS-MR-1X082RY-A 8GB DDR3-1600-MHz RDIMM/PC3-12800/dual rank/x4/1.35v 1.35 V 2
UCS-MR-1X082RX-A 8GB DDR3-1333-MHz RDIMM/PC3-10600/dual rank/x4/1.35v 1.35 V 2
UCS-MR-1X041RY-A 4GB DDR3-1600-MHz RDIMM/PC3-12800/single rank/x4/1.35v 1.35 V 1
UCS-MR-1X041RX-A 4GB DDR3-1333-MHz RDIMM/PC3-10600/single rank/x4/1.35v 1.35 V 1
Memory Mirroring Option
N01-MMIRROR Memory mirroring option
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
15
Select 2, 4, 6, 8, 10, or 12 identical DIMMs. The DIMMs will be placed by the factory as shown
in the following table.
Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on page 14.
(3) 2-CPU configuration without memory mirroring:
Select from 1 to 12 DIMMs per CPU. Refer to Memory Population Rules, page 52, for more
detailed information.
Total
Number
of
DIMMs
CPU 1 DIMM Placement in Channels
(for
identical DIMMs)
Blue Slot
(Slot 1)
Black Slot
(Slot 2)
Black Slots
(Slot 3)
2 (A1, B1)
4 (A1,B1); (C1,D1)
6 (A1,B1); (C1,D1) (A2,B2)
8 (A1,B1); (C1,D1) (A2,B2); (C2,D2)
10
1
Notes . . .
1. This configuration cannot be implemented with quad-rank DIMMs (the 32 GB DIMM). You can have
only 1 or 2 DIMMs per channel when using quad-rank DIMMs.
(A1,B1); (C1,D1) (A2,B2); (C2,D2) (A3,B3)
12
1
(A1,B1); (C1,D1) (A2,B2); (C2,D2) (A3,B3); (C3,D3)
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
16
CONFIGURING the SERVER
(4) 2-CPU configuration with memory mirroring:
Select 2, 4, 6, 8, 10, or 12 identical DIMMs per CPU. The DIMMs will be placed by the factory
as shown in the following table.
Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on page 14.
Number
of
DIMMs
per CPU
CPU 1 DIMM Placement in Channels
(for
identical DIMMs)
CPU 2 DIMM Placement in Channels
(for
identical DIMMs)
Blue Slots Black Slots Black Slots Blue Slots Black Slots Black Slots
2 (A1, B1) (E1, F1)
4 (A1,B1);
(C1,D1)
(E1,F1);
(G1,H1)
6 (A1,B1);
(C1,D1)
(A2,B2) (E1,F1);
(G1,H1)
(E2,F2)
8 (A1,B1);
(C1,D1)
(A2,B2);
(C2,D2)
(E1,F1);
(G1,H1)
(E2,F2);
(G2,H2)
10
1
Notes . . .
1. This configuration cannot be implemented with quad-rank DIMMs (the 32 GB DIMM). You can have only 1 or 2
DIMMs per channel when using quad-rank DIMMs.
(A1,B1);
(C1,D1)
(A2,B2);
(C2,D2)
(A3,B3) (E1,F1);
(G1,H1)
(E2,F2);
(G2,H2)
(E3,F3)
12
1
(A1,B1);
(C1,D1)
(A2,B2);
(C2,D2)
(A3,B3);
(C3,D3)
(E1,F1);
(G1,H1)
(E2,F2);
(G2,H2)
(E3,F3);
(G3,H3)
NOTE: System performance is optimized when the DIMM type and quantity are equal
for both CPUs.
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
17
Caveats
The server supports 1, 2, or 3 DIMMs per channel for single- or dual-rank RDIMMs.
The server supports 1, 2, or 3 DIMMs per channel for quad-rank LRDIMMs.
The server supports registered DIMMs (RDIMMs) or load-reduced DIMMS (LRDIMMs), however,
do not mix RDIMMs and LRDIMMs in a server.
When using mirroring, DIMMs must be installed in identical pairs across paired DDR3 buses.
That is, mirrored pairs in channels A and B must be identical and pairs in channels C and D
must be identical. However, the DIMMs used in channels A and B and in C and D can be
different.
UDIMMs and non-ECC DIMMs are not supported.
Memory mirroring reduces the amount of available memory by 50% (quantity of DIMMs must
be even for mirroring).
When single- and dual-rank DIMMs are populated for 2DPC, always populate the dual-rank
DIMM in the blue DIMM slot first (blue slot) and the single-rank DIMM last in the black DIMM
slots (only the 4GB DIMMs are single-rank).
By default, all DIMMs run at 1.35 V, which yields 1333-MHz memory speeds. To run the
memory DIMMS at 1600 MHz, you need to go into the BIOS or set the policy with UCSM
(service profile) to run in Performance Mode. This forces the DIMMs to operate at 1.5 V and
yields 1600-MHz speeds, provided:
The DIMMs are 1600-MHz devices and the DIMM type is RDIMM
The CPUs chosen support 1600-MHz operation
There are less than 3 DIMMs per channel
With 3 DIMMs populated per channel, memory always runs at 1.5 V regardless if the BIOS
setting is low-power mode (1.35 V) or performance mode (1.5 V).
For more information regarding memory, see CPUs and DIMMs, page 50.
NOTE: Memory speed is limited to 1066 MHz for 3 DPC configurations.
NOTE: 32 GB LRDIMMs run at a maximum speed of 1333 MHz for 1DPC and 2DPC even
though their specified maximum speed is 1600 MHz.
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
18
CONFIGURING the SERVER
STEP 4 SELECT RAID CONFIGURATION
The RAID controller choices are:
Embedded RAID (on motherboard)
Mezzanine RAID controller cards
Plug-in PCIe RAID controller cards
Cisco can provide factory-configured RAID systems depending on the RAID controller chosen and
the number of drives ordered. Factory-configured RAID options are listed with each RAID card
description.
Select RAID Options
Select as follows:
One embedded RAID upgrade option (see Table 5), or
One mezzanine RAID controller (see Table 6), or
One PCIe RAID controller card (see Table 7 on page 19)
NOTE: If you do not select a mezzanine card, a plug-in PCIe RAID card, or one of the
embedded RAID upgrade options, you will have an embedded SATA-only RAID
controller that supports up to four SATA-only drives (RAID 0, 1, 10)
NOTE: The number of RAID groups (logical drives/virtual drives) supported per
controller is as follows:
Embedded RAID = 8 drives
Cisco UCSC RAID SAS 2008M-8i Mezzanine Card = 16 drives
LSI MegaRAID SAS 9266-8i/9266CV-8i RAID controller cards = 64 drives
Table 5 Available Embedded RAID Options
Product ID (PID) PID Description
RAID Controllers
UCSC-RAID-ROM5 Onboard RAID, supporting up to 8 SAS or SATA drives. SAS and SATA drives can
be mixed. This option supports RAID 0, 1, and 10, and operates at 3 Gb/s.
Operating systems supported are Windows and Linux only (no VMware
support).
UCSC-RAID-ROM55 Onboard RAID, supporting up to 8 SAS or SATA drives. SAS and SATA drives can
be mixed. This option supports RAID 0, 1, 10, and 5, and operates at 3 Gb/s.
Operating systems supported are Windows and Linux only (no VMware
support).
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
19
Table 6 Available Mezzanine Card RAID Options
Product ID (PID) PID Description
RAID Controllers
UCSC-RAID-11-C240 Cisco UCSC RAID SAS 2008M-8i Mezzanine Card (RAID 0, 1, 10, 5, and 50
supported), operating at 6 Gbs.
Supports up to 8 or 16 internal SAS or SATA drives (depending on the
backplane size). SAS and SATA drives can be mixed.
Factory-configured RAID options available: RAID 0, 1, 10, and 5 (see the
RAID PIDs section in this table)
No data cache backup
UCSC-RAID-MZ-240 Cisco UCSC RAID SAS 2008M-8i Mezzanine Card (RAID 0, 1, 10 supported),
operating at 6 Gbs.
Supports up to 8 or 16 internal SAS or SATA drives (depending on the
backplane size). SAS and SATA drives can be mixed.
Factory-configured RAID options available: RAID 0, 1, and 10 (see the RAID
PIDs section in this table)
No data cache backup
Table 7 Available Plug-In PCIe Card RAID Options
Product ID (PID) PID Description
RAID Controllers
UCS-RAID-9266NB LSI MegaRAID SAS 9266-8i RAID controller card with no data cache backup
(RAID 0, 1, 10, 5, 6, 50, and 60 supported), operating at 6 Gbs.
Installed by default in the half-height PCIe slot (slot 2)
Supports up to 24 internal SAS and/or SATA drives. SAS and SATA drives can
be mixed.
Includes 1 GB of write cache
Factory-configured RAID options available: RAID 0, 1, 10, 5, and 6 (see the
RAID PIDs section in this table)
UCS-RAID-9266CV LSI MegaRAID SAS 9266CV-8i RAID controller card with data cache backup (RAID
0, 1, 10, 5, 6, 50, 60), operating at 6 Gbs.
Supports up to 24 internal SAS or SATA drives. SAS and SATA drives can be
mixed.
Includes a 1 GB Transportable Memory Module (TMM) and SuperCap power
module for data cache backup
Factory-configured RAID options available: RAID 0, 1, 10, 5, and 6 (see the
RAID PIDs section in this table)
Super Capacitor Option
UCS-RAID-CV-SC= LSI CacheVault Power Module for SAS 9266CV-8i
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
20
CONFIGURING the SERVER
RAID Configuration Options
R2XX-RAID0 Factory preconfigured RAID striping option
Enable RAID 0 Setting. Requires a minimum of one hard drive.
R2XX-RAID1 Factory preconfigured RAID mirroring option
Enable RAID 1 Setting. Requires exactly two drives with the same size, speed,
capacity.
R2XX-RAID5 Factory preconfigured RAID option
Enable RAID 5 Setting. Requires a minimum of three drives of the same size,
speed, capacity.
R2XX-RAID6 Factory preconfigured RAID option
Enable RAID 6 Setting. Requires a minimum of four drives of the same size,
speed, capacity.
R2XX-RAID10 Factory preconfigured RAID option
Enable RAID 10 Setting. Requires a even number of drives (minimum of four
drives) of the same size, speed, capacity.
NOTE: Although RAID levels 50 and 60 are not orderable from the factory, they are
supported for selected controllers as shown in Table 5
NOTE: No RAID option can be chosen if you have no drives
Table 7 Available Plug-In PCIe Card RAID Options (continued)
Product ID (PID) PID Description
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66

Cisco UCS-MR-1X082RY-A= Datasheet

Category
Memory modules
Type
Datasheet
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI