Hunter Fan 52008, 52009 Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the Hunter Fan 52008 Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
www.HunterFan.com
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
Table of Contents
PAGE
21
30 inches
7 feet
PAGE
2
What to Expect with
Your Installation
PAGE
5
Ceiling Bracket
Ladder
PAGE
3
Tools Needed
PAGE
11
Wiring
Operation
Maintenance
& Cleaning
Troubleshooting
PAGE
6
Preparation
?
?
?
Canopy
PAGE
12
PAGE
7
Downrod
PAGE
13
Blades
PAGE
15
Light Kit
PAGE
14
Switch Housing
PAGE
19
PAGE
4
Mounting Options
PAGE
10
Secondary
Hanging System
Congratulations on purchasing
your new Hunter® ceiling fan!
It will provide comfort and
performance in your home
or ofce for many years. This
installation and operation
manual contains complete
instructions for installing and
operating your fan.
We are proud of our work and
appreciate the opportunity
to supply you with the best
ceiling fan available anywhere
in the world.
To register your fan,
please visit:
www.HunterFan.com/
register
Save your receipt for proof of
purchase.
PAGE
17
Remote Control
1
www.HunterFan.com
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
What to Expect with Your Installation
Know your wiring
If you are unfamiliar
with wiring, use a
qualied electrician.
You may need a
friend to help you.
Check box to see
fan weight
Assess location
30 inches
from blade tip
to nearest wall
or obstruction
7 feet
from bottom
edge of blade
to the oor
Select a downrod length
Assess ceiling angle
Must be able to
secure the fan to
building structure or
fan-rated outlet box
1
2
3
Standard Downrod
for ceilings 8-10 feet high
Shorter Downrod
for fans installed close to ceiling
Longer Downrod
for ceilings 10 feet or higher
2
Ceiling angles greater
than 34° will require an
Angled Mounting Kit.
See page 4 for details.
Read and Save These Instructions
This product conforms to UL Standard 507.
WARNINGS
CAUTIONS
w.1 - To reduce the risk of re, electrical shock, or personal
injury, mount fan directly from building structure and/or an
outlet box marked acceptable for fan support of 70 lbs (31.8 kg)
and use the mounting screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing or
servicing your fan, disconnect the power by turning off the
circuit breakers to the outlet box and associated wall switch
location. If you cannot lock the circuit breakers in the off
position, securely fasten a prominent warning device, such as a
tag, to the service panel.
w.3 - To reduce the risk of re, electrical shock, or motor damage,
use only Hunter Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the blade
brackets when installing the blade brackets, balancing the blades,
or cleaning the fan. Do not insert foreign objects in between
rotating fan blades.
c.1 - All wiring must be in accordance with national and local
electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring,
use a qualied electrician.
c.2 - Use only Hunter replacement parts.
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and if not
installed and used in accordance with the instructions may cause
harmful interference to radio communications.
www.HunterFan.com
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
3
Tools Needed
Ladder
Power Drill
(optional)
9/64” Drill Bit
(optional)
Screwdrivers
Pliers Wire Strippers
If mounting to a support structure, you will also need these tools.
www.HunterFan.com
4
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
Mounting Options (continued)
If you have an angled ceiling:
1. You will need a longer downrod (sold separately).
2. If your ceiling angle is greater than 34°, you will
also need an Angled Mounting Kit (sold separately).
Guide Touches
BOTH Ceiling & Wall
S
I
T
U
A
T
I
O
N
1
Guide Touches
Wall
but
NOT Ceiling
S
I
T
U
A
T
I
O
N
2
You need BOTH
a Longer
Downrod &
an Angled
Mounting Kit
You need ONLY
a Longer
Downrod
*most common
If you have a at ceiling:
Hang your fan by a standard downrod (included).
Mounting Options
Use Standard Mounting
or Low-Prole Mounting
to hang the fan from a at ceiling.
Use Angled Mounting
to hang the fan from a
vaulted or angled ceiling.
4
34
O
CEILING
WALL
OPTION
1
Standard
Mounting
OPTION
2
Angled
Mounting
2 3
SLIDE
toward ceiling
PLACE
against wall
1
FOLD
on dotted line
34°
Use the three steps below to determine if your ceiling angle is greater than 34°
Support
Structure
Ceiling
Outlet Box
(required)
Angled
Mounting
Style
Standard
Mounting
Style
Support
Structure
Ceiling
Outlet Box
(required)
www.HunterFan.com
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
Ceiling Bracket
Refer to warning w.1 on pg. 2
To avoid possible electrical shock, before
installing your fan, disconnect the power by
turning off the circuit breakers to the outlet
box associated with the wall switch location.
For angled ceilings, point
opening toward peak.
If you are unable to do this,
call Technical Support at
1-866-268-1936.
Make sure all four bumpers are
still attached.
Use wood screws
(included) when securing
to support structure with
approved electrical outlet
box. Drill 9/64” pilot holes
in support structure to aid
in securing ceiling bracket
with hardware found in
the hardware bag.
Use machine screws
(provided with outlet
box) when securing to
existing ceiling fan-rated
outlet box. Make sure
it is securely installed
and is acceptable for fan
support of 31.8 kg (70 lbs)
or less.
Turn Power
OFF
5
www.HunterFan.com
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
Preparation
D
I
S
C
A
R
D
K
E
E
P
!
Remove the shipping blocks from the
motor. Save the screws. They will be
needed for blade iron installation.
Note: Some fans will have a shipping
ring instead of shipping blocks. Please
remove the ring and save the screws.
Time Saver Tip: Get a helper
to insert grommets, found in
the hardware bag, into the
blades while you’re doing the
next couple of steps.
If you are installing multiple remote-controlled
fans on the same circuit breaker,
you may need to perform a few extra steps to
prevent interference or faulty operation of your
remote controls.
Go to www.HunterFan.com/FAQs and click
“How do I properly install multiple remote-
controlled fans?” for more information.
6
www.HunterFan.com
7
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
Downrod
Slide
Slide
1 2 3 4 5
678910
Sold Separately
Included
Longer
Downrod
for angled
ceilings or
ceilings 10’ or
higher
Shorter
Downrod
for fans installed
close to ceiling
Standard
Downrod
for ceilings 8-10’ high
Option 1Option 2
Option 3
skip to next page
If you need a different downrod length follow these steps:
Steps 1-5 to remove standard downrod pipe
Steps 6-10 to reassemble with new pipe
Included
(pre-assembled)
www.HunterFan.com
8
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
KEEP!
8”
3/8”
C
U
T
&
S
T
R
I
P
(not to scale)
Remove the pre-installed
setscrew so that the downrod
can be inserted.
Hand tighten the downrod (at
least 4-5 full turns) until it stops.
The wires can be cut, but
leave at least 8” extending
from the top of the downrod.
Downrod (continued)
8”
3/8”
Tighten the setscrew
with pliers. DO NOT
HAND TIGHTEN.
If the setscrew is not tightened
securely, the fan may fall.
K
E
E
P
!
www.HunterFan.com
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
Downrod (continued)
DO NOT PICK THE FAN UP BY THE
CANOPY OR WIRES. Place the downrod
ball into the slot in the ceiling bracket.
Put the wires and downrod through
the canopy. Let the canopy sit loosely
on top of the fan.
9
www.HunterFan.com
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
Secondary Hanging System
3mm (1/8")
Insert the looped end of the
braided cable through the ceiling
bracket and one of the holes in the
outlet box into the ceiling. Access
the support brace in the ceiling.
You may not be able to do this from
below the ceiling depending on
your installation site.
Drive the wood screw and
washer found in the bag
into the side of the support
brace that holds the outlet box.
Leave 3 mm (1/8”) of space
between the support brace
and the washer.
Wrap the braided cable around
the support brace once creating
a complete circle. Hook the
looped end of the cable over the
wood screw so that the cable
lies between the washer and the
support brace.
Tighten the loop and secure the
screw and washer all the way
down to the support brace. Coil
up the excess cable.
Outlet Box
Ceiling
Support
Brace
Braided
Cable
10
www.HunterFan.com
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
Wiring
Refer to CAUTION c.1 on pg. 2
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
Using an orange wire
connector from
the hardware
bag, connect the
3 grounding wires
(green, green/yellow
stripe, or bare copper)
coming from the
ceiling, downrod, and
hanging bracket.
F
R
O
M
R
E
C
E
I
V
E
R
F
R
O
M
C
E
I
L
I
N
G
F
R
O
M
C
E
I
L
I
N
G
B
R
A
C
K
E
T
green/yellow
stripe (grounding)
green/yellow
stripe
green/yellow stripe
black
blue
yellow
blue
Note: To connect the
wires, hold the bare
metal leads together and
place a wire connector
over them, then twist
clockwise until tight.
Using the orange
wire connectors
from the remote
control hardware
bag, connect the blue
wire from the receiver
to the blue wire (or
possibly black with
white stripe wire) from
the fan. Connect the
yellow wire from the
receiver to the black
wire from the fan.
F
R
O
M
F
A
N
F
R
O
M
F
A
N
F
R
O
M
R
E
C
E
I
V
E
R
Using the orange wire
connectors from
the hardware bag,
connect the black wire
(ungrounded) from
the ceiling to the black
wire from the receiver.
Connect the white
wire (grounded) from
the ceiling to both the
white wire from the
receiver and the white
wire from the fan.
F
R
O
M
C
E
I
L
I
N
G
black
(ungrounded)
white (grounded)
black
white
F
R
O
M
F
A
N
white
11
www.HunterFan.com
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
Canopy
Lift the canopy into place so that
the screw holes are aligned.
Position the canopy so that, when
lifted into place, the canopy ts into
the hanging bracket as shown.
Screw
Holes
Insert the two canopy screws
found in the hardware bag.
Note: Fan style may vary.
12
www.HunterFan.com
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
Blades
Your blades are shielded with Dust Armor® which
is a nanotechnology coating that repels dust. For
cleaning the fan, use soft brushes or cloths to prevent
scratching. Cleaning agents may damage the nishes.
Lightly attach the blade irons to the
motor with screws found in
the hardware bag, then securely
tighten after both screws are attached.
Remember the screws that
you kept after removing the
shipping blocks (page 6)? You
need them plus ve more from
the hardware bag for this step.
Insert grommets found in the hardware
bag into the holes in the blades, then
secure each blade to a blade iron with
screws found in the hardware bag.
13
www.HunterFan.com
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
Feed the wire plug through the center
hole of the upper switch housing, then
wrap keyhole slots around the screws and
twist counterclockwise.
Screw two housing assembly screws
from the hardware bag halfway into
the motor housing. It does not matter
which two screw holes you choose.
Insert the third screw, found in
the hardware bag, into place and
then tighten all three screws.
Make sure the upper switch housing is securely
attached to the mounting plate. Failure to properly
secure all 3 assembly screws could result in the switch
housing xture falling.
Switch Housing
14
www.HunterFan.com
15
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
Connect the plugs from the upper and
lower switch housings. Make sure to line
up the colored markings on
the connectors.
Partially install two of the switch housing screws
found in the bag. Align the notches in the
sides of the lower switch housing with the
upper switch housing screws. Twist the lower
switch housing clockwise to lock into place.
Light Kit
Install the third switch housing screw.
Tighten all three screws securely.
Switch
Housing
Screw
Notch
Make sure the lower switch housing is securely attached to
the upper switch housing. Failure to properly secure all three
assembly screws could result in the light xture falling.
Want to install your fan without a light kit?
Go to www.HunterFan.com/FAQs and click
“How do I install my fan without the light kit?”
www.HunterFan.com
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
Light Kit (continued)
Note: Glass shade style and number of lights may vary.
Install a bulb into each of the
sockets. When necessary, replace
with bulbs of the same wattage.
Bulb
To install the shade, rst loosen
the thumb screws. Raise the
shade to the light xture. Tighten
all thumbscrews securely.
Shade
Thumb Screw
Connect the appropriate pull chain
pendant to each of the short chains
coming from the switch housing.
Fan Pull
Chain
Light
Pull
Chain
16
www.HunterFan.com
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
Remote Control
Note: The remote must be paired before
the fan will operate.
Within 3 minutes of restoring power to
the fan, press both the Fan Off button and
the High button for at least 4 seconds. Your
fan will turn on low to indicate successful
syncing. If it does not, turn off power to your
fan, wait 1 minute then try again. If using the
transmitter with multiple fans, repeat this
process for each fan.
Fan Off
High
To access the battery compartment, remove
the small Phillips head screw that secures the
battery door to the transmitter assembly. The
battery should be installed with the positive
(+) side up. Replace with a CR2032 battery
when necessary.
Phillips
Head
Screw
Battery
Door
If you are installing multiple remote-controlled fans on
the same circuit breaker, you may need to perform a few
extra steps to prevent interference or faulty operation of
your remote controls.
Go to www.HunterFan.com/FAQs and click
“How do I properly install multiple remote-controlled fans?”
for more information.
Turn Power
ON
17
www.HunterFan.com
18
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
Light Button
Push the light button on the remote transmitter.
Pull the light chain once. If the light does not
turn on, repeat step.
Light Chain
Push the 3 button on the remote transmitter for
high fan speed. Pull the fan speed chain until
the fan is on the highest speed.
3 Button
Fan Speed Chain
See next page for fan
operation instructions.
Remote Control (continued)
Light Button
CONGRATULATIONS!
YOU’RE DONE!
Note: In compliance with Canadian federal energy regulations, this
ceiling fan contains a device that restricts its light output. Exceeding
the wattage limit marked on the MAX wattage sticker afxed to the
light socket(s) may result in re hazard or improper operation.
www.HunterFan.com
19
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
Rocker- Style
Plate
Switch Cover Plate
Removed
Tabs
To install the transmitter cradle, remove the
two screws holding the switch cover plate. Do
not remove the cover plate. Orient the cradle
by lining up the two mounting holes with
those on the cover plate. Insert and tighten
the screws. Do not over tighten.
Note: For rocker-style cover plates, break off
the tabs by pushing outward.
To turn on fan, press a fan speed button. Speeds
range from off (0) to high (3). Quickly press the
Light button to turn the lights off and on.
Medium
Speed
Light
High
Speed
Fan
Off
Low
Speed
Operation, Maintenance, & Cleaning
To switch the direction of air ow, move the
reverse switch to the opposite position.
Reverse
Switch
www.HunterFan.com
1.866.268.1936
M0066-01 • 05/13/14 • © Hunter Fan Company
For questions regarding removing a light kit, call
customer service 1-866-268-1936.
Operation, Maintenance, & Cleaning (continued)
For cleaning the fan, use soft brushes or
cloths to prevent scratching. Cleaning
products may damage the nishes.
Safe-Exit
Press the Fan Off button for at least three seconds to
initiate the Safe-Exit Mode.
The lights will ash for visual conrmation.
The lights will stay on 50% brightness for 15 seconds and
then begin to dim. After a total of 30 seconds, the lights
will be completely off.
The Safe-Exit Program gives you about thirty seconds of
light when you turn the lights off to exit the room before
the lights go out. To use Safe-Exit:
Note: For CFL lighting, the lights will stay on 100%
brightness for 30 seconds. After a total of 30 seconds, the
lights will be completely off.
20
/