Eaton YHH30B Series User manual

Type
User manual
Instruction Manual
YHH30B Series
Explosion-proof Fixed Camera Station
Ex Marking:
II 2G Ex db II C T5 Gb (normal version) or
Ex db op pr IIC T5 Gb (optical fiber version)
II D Ex tb IIIC T95°C Db (normal version) or
Ex tb op pr IIIC T95°C Db (optical fiber version)
Certificate numbers: Presafe 19 ATEX 15006X, IECEx PRE 19.0070X
2 EATON www.eaton.com
Safty Requirement
Please read this Instruction Manual carefully before
installation and operation of this product.
1. Installation
Please read this Instruction Manual carefully before installation or
operation of this product and follow the Instruction Manual strictly.
Remove the power supply before any maintenance or repair of
the product.
Avoid opening of this product in environment where smoke,
heavy dust, high temperature or dewing may exist. These will
cause the decrease of the image definition.
Connect the cables according to the requirement indicated in
the Instruction Manual, or fault may occur.
Protect the flame proof joint in maintenance, avoid any metal
fragment or other abrasive substances getting inside the
internal chamber.
No disassembly or modification allowed.
2. Environmental protection
Components of the products made by our company may pollute
the environment, such as the PCB, electrical elements, plastic
and lubricant, collection and control measurement shall be
taken in maintenance and decommission of the products. These
pollution sources shall be delivered to the relevant authorities
for further treatment, do not casually discard, avoid any adverse
effect to the environment.
3EATON www.eaton.com
1.0 Content
1.0 General ........................................................................................................................................... 4
2.0 Technical data ................................................................................................................................ 4
2.1 Type and model .......................................................................................................................... 4
2.2 Certification ............................................................................................................................... 4
2.3 Model ........................................................................................................................................ 4
2.4 Electrical data ............................................................................................................................ 4
2.5 Mechanical data......................................................................................................................... 4
2.6 Service condition ....................................................................................................................... 4
2.7 Dimension ................................................................................................................................. 5
2.8 Installation size .......................................................................................................................... 5
2.9 Wiring ........................................................................................................................................ 5
3.0 Installation and service ................................................................................................................. 8
3.1 Safety cautions .......................................................................................................................... 8
3.2 Cable treatment ......................................................................................................................... 8
3.3 Fiber optic cable processing ...................................................................................................... 8
3.4 Installation of protective shield and cylinder ............................................................................. 8
3.5 System connection .................................................................................................................... 8
3.6 Install camera to platform ......................................................................................................... 9
3.7 Install camera to fixed support .................................................................................................. 9
3.8 Flame proof joint protection ...................................................................................................... 9
3.9 Grounding .................................................................................................................................. 9
3.10 Camera Time settings .............................................................................................................. 9
4.0 Ex structure instruction ................................................................................................................ 9
5.0 Troubleshooting ........................................................................................................................... 10
6.0 Transportation and storage ........................................................................................................ 10
7.0 Mounting accessories ..................................................................................................................11
8.0 Quality guarantee ........................................................................................................................ 13
9.0 Company statements .................................................................................................................. 13
Annex 1: Use of drying agent .......................................................................................................... 14
Annex 2: Table of poisonous and harmful substances or elements ............................................. 15
4
Installation instructions for YHH30B CCTV camera station
English
EATON TM378 ISSUE A JULY 2020 www.eaton.com
1.0 General
YHH30B Series Explosion-proof Fixed Camera Station is
manufactured according to EN IEC60079-0:2018, EN60079-1:2014,
EN60079-28:2015, EN60079-31:2014. It is used in the hazardous
areas which are classified as Zone 1 and Zone 2, Group IIA, Group
IIB and Group IIC gases, temperature group T1~T6, Zone 21
and Zone 22, containing a combustible dust atmosphere or the
combination of either. The product has the characteristics of small
volume, light weight, and ease of installation. It can be used in
petroleum, chemical, jetty, port, mine, spaceflight, war industry
and foodstuff process area.
All associate technical document, drawings and samples of
YHH30B Series Explosion-proof Fixed Camera Station(hereinafter
referenced as camera) are tested and certified by DNV, the
certification numbers are Presafe 19 ATEX 15006X, IECEx PRE
19.0070X.
Specifc Conditions of Use
Repairs of the flameproof joints must be made in compliance
with the structural specifications provided by the manufacturer.
Repairs must not be made on the basis of values specified in
tables 3 and 4 of EN 60079-1.
The mechanical property class of the fasteners which are
relevant to the flameproof joint should be at least A4-70 with
min. yield stress 450Mpa.
Before application, separate ATEX certified EX db IIC Gb or/
and Ex tb IIIC Db IP66/IP68 cable gland should be incorporated.
Unused entries must be closed by suitable ATEX or IECEx
certified blank plugs.
Before application, the optical fibre must be connected and
protected according to the guidance in the instruction manual to
meet the requirements of IEC 60079-28.
Essential Health and Safety Requirements
Essential Health and Safety Requirements (EHSRs) are covered by
the standards listed at item 9.
2.0 Technical data
2.1 Type and model
Second stage
Design code
Ex product code, H stand for
protective shield
Company code
YH H 30
2.2 Certification
Ex marking:
II 2G Ex db IIC T5 Gb (normal version) or Ex db
op pr IIC T5 Gb
(optical fiber version)
II 2D Ex tb IIIC T95°C Db (normal version) or Ex
tb op pr IIIC T95°C Db
(optical fiber version)
Cer. number: Presafe 19 ATEX 15006X, IECEx PRE 19.0070X
2.3 Model
YHH30B
Ex camera set, Wiper can be installed according to
customer reqvuirements
2.4 Electrical data
Input voltage 110~240V a.c. / 24V a.c. 50Hz/60Hz
Input Voltage floating
range
±10%
Current 0.2~0.45A /≤2A
POE Input voltage DC54V, ≤1A
Power supply of the
camera
12VDC (provided by internal device)
Consumption 50W
Network video signal
output
Output via CAT5e
Output via fiber
Output via coaxial cable (EOC)
Electrical connection
three-core cable is used for power supply, CAT5e cable is
used for camera control and Network signal output
2.5 Mechanical data
Material: stainless steel 316L
IP code
IP66
IPX8 (1.2M/45min) (The equipment has been
separately tested against the requirements of
IEC 60529)
External dimension 487.5(L) x 202(H) x 172.5(W) mm
Observation
port
Thickness 15mm
Exposed area Φ68mm
Weight/ Hauled weight 15Kg / 27.5Kg
Numbers of cable entries 3
Thread spec of the cable entries M25×1.5
Installation method
Electrical platform, semi-fixed platform,
fixed support
2.6 Service condition
Atmospheric pressure 80~110KPa
Ambient temperature
-40°C~+65°C
Relative humidity
95%RH(+25°C)
5
Installation instructions for YHH30B CCTV camera station
English
EATON TM378 ISSUE A JULY 2020 www.eaton.com
2.7 Dimension
Figure 1. External dimensions of YHH30B.
2.8 Installation size
Figure 2. Fixing holes at the bottom of the camera
2.9 Wiring
The product has the following wiring methods, please select one of the wiring methods according to the purchased specifications.
AC24V or AC220V input + Network video signal network cable output
6
Installation instructions for YHH30B CCTV camera station
English
EATON TM378 ISSUE A JULY 2020 www.eaton.com
AC24V or AC220V input + Network video signal coaxial cable output
AC24V or AC220V input + Network video signal fiber output
7
Installation instructions for YHH30B CCTV camera station
English
EATON TM378 ISSUE A JULY 2020 www.eaton.com
Power Over Ethernet
8
Installation instructions for YHH30B CCTV camera station
English
EATON TM378 ISSUE A JULY 2020 www.eaton.com
3.5 System connection
power input
The picture above is the 110~240V a.c. / 24V a.c. wiring method. POE power supply,
please directly connect the network cable to the input end of the built-in POE receiving device.
Figure 4.
3.0 Installation and service
3.1 Safety cautions
Check the following items before installation:
a. whether certification number is indicated;
b. check the Ex marking to confirm it is suitable for the
hazardous area application
c. ensure all the components are not damaged and with no
defect that may affect the explosion-proof performance;
d. whether the internal and external grounding are well
connected.
3.2 Cable treatment
To maintain the certification requirement of the units all cables/
conduits must be fitted at the entry, with certified Exd flameproof,
compound filled barrier glands, suitable for the application IP68.
Use cables of rated temperature above 75°C and wires of rated
temperature above 90°C.
3.3 Fiber optic cable processing
This product does not provide an output cable. Users using the
optical signal output version, please weld the incoming fiber and
the fiber jumper provided by our company with a fiber fusion
splicer. The welding place needs to be protected by a fiber
protection tube and placed in the fiber protection bracket . As
shown below.
Figure 3.
The insulation-fiber-removed optical fiber placed in the optical fiber
protection bracket needs to be protected by an insulation sleeve to
prevent light leakage.
3.4 Installation of protective shield and cylinder
Since this Ex camera set has high grade of protection level and
the flame proof surfaces are tightly contacted, pay attention to
protect the flame proof joint in installation. The rear cover and rear
part of the cylinder are flame proof surface, no knock or scratch
allowed. For the camera “ DO NOT OPEN WHEN ENERGIZED!”
An insulation gasket is adopted between the drawer plate and rear
cover plate of the rear cover assembly, measure the insulation
performance in cases of disassembling, the measured value shall
be no less than 100M. There is a grounding bolt mounted on the
middle of the rear cover, it shall be well grounded in installation.
9
Installation instructions for YHH30B CCTV camera station
English
EATON TM378 ISSUE A JULY 2020 www.eaton.com
3.6 Install camera to platform
See Instruction Manual for the electrical platform.
3.7 Install camera to fixed support
Figure 6. Installation of YHH30B support
3.8 Flame proof joint protection
Protect the flame proof joint in installation, operation, maintenance
of this product, no knock or scratch allowed.
3.9 Grounding
Internal and external grounding shall be well connected and
reliable.
3.10 Camera Time settings
During product use, the camera needs to reset the time after each
power outage restart.
4.0 Ex structure instruction
The maximum surface temperature will no more than 80°C in
normal operation.
Toughened glass is adopted in observation port, the toughened
glass has passed the impact and thermal shock test.
10
Installation instructions for YHH30B CCTV camera station
English
EATON TM378 ISSUE A JULY 2020 www.eaton.com
5.0 Troubleshooting
phenomenon analysis solution remark
Windshield wiper
locked send back for repair
blind corner adjust the axis self handle
No image
open circuit of
power supply
check the power
supply
self handle
open circuit of
signal wire
check the signal
wire
self handle
damaged camera replace the camera
contact the
manufacturer
damaged lenses replace the lenses
contact the
manufacturer
6.0 Transportation and storage
The packaged product can be delivered in all modes of
transportation but without exposure to direct rain or snow; it
can be stored for one year in environment of temperature range:
0°C~+40°C and humidity no more than 90%.
11
Installation instructions for YHH30B CCTV camera station
English
EATON TM378 ISSUE A JULY 2020 www.eaton.com
7.0 Mounting accessories
Mounting accessories(order needed):
Figure 7. YHZ-B20 support
12
Installation instructions for YHH30B CCTV camera station
English
EATON TM378 ISSUE A JULY 2020 www.eaton.com
Platform (top view) Platform (side view) Platform(bottom view)
Figure 8. YHZ-F1 semi-fixed platform
13
Installation instructions for YHH30B CCTV camera station
English
EATON TM378 ISSUE A JULY 2020 www.eaton.com
8.0 Quality guarantee
For all Ex product we promise 1 years quality warranty.
We provide free maintainence service in the guarantee period
except the follow conditions:
Damage caused by improper installation or operation and not in
accordance with this instruction manual.
Damage caused by unauthorized disassembly.
Thunder or other force majeure natural disasters.
If any other contracts between clients and us exist, we will follow
the promise or regulation strictly.
9.0 Company statements
Cooper Yuhua(Changzhou) Electric Equipment Manufacturing
Co., Ltd. reserves the right to the interpretation of the
modification of product design and specification without notice.
This Instruction Manual is Cooper Yuhua(Changzhou) Electric
Equipment Manufacturing Co., Ltd. owned, any copy or
plagiarization in any form of this document or part of this
document without written authorization is illegal, and we will
reserve the right to take any legal actions.
14
Installation instructions for YHH30B CCTV camera station
English
EATON TM378 ISSUE A JULY 2020 www.eaton.com
Annex 1: Use of drying agent
A package of drying agent is provided with accessories. Put the drying agent inside the chamber after it’s well installed and wired. The
place of drying agent put shall be away from the transmission element or electrical connection zone and difficult to slip to other places,
avoid any connection fault or transmission fault caused by drying agent.
15
Installation instructions for YHH30B CCTV camera station
English
EATON TM378 ISSUE A JULY 2020 www.eaton.com
Annex 2: Table of poisonous and harmful substances or elements
Component
Poisonous and harmful substances or elements
Lead
(Pb)
Mercury
(Hg)
cadmium
(Cd)
chromium VI
(Cr6+)
Polybromide
(PPB)
Polybrominated diphenyl
ethers (PBDE)
Stainless steel 304
Casting component
PCB
Movement
Connection cable
Power supply
(if applicable)
Support
(if applicable)
Accessories
Remark:
1. Symbol means the content of the poisonous, harmful substances or elements in the component (homogeneous material) is lower
than the limit specified in the standard;
2. Symbol × means the content of the poisonous, harmful substances or elements in the component (some certain homogeneous
material) is more than the limit specified in the standard SJ/T11363-2006. Leakage or mutation of this poisonous, harmful
substances or elements will not happen in the environmental life and will not harm the user’s health or properties. Treatment of
this poisonous, harmful substances or elements can not carried out by user selves, please deliver it to the appointed department
according to the local laws or regulation.
Eaton is a registered trademark.
All other trademarks are property
of their respective owners.
Eaton
No.60 Hehuan Rd, Zhonglou Development
Zone, Changzhou, Jiangsu, China.
Tel: 0519-83900389, 83900558ZIP
code: 213023
Fax: 0519-83978970
Website: http://www.eaton.com/yuhua-cctv
© 2020 Eaton
All Rights Reserved
Publication No. TM378 Issue A
July 2020
Eaton is a registered trademark.
All other trademarks are property
of their respective owners.
CONFIDENTIAL —
For internal use only by Eaton and
authorized distributors.
This information is intended to provide a
comparative analysis between Eatons
products and those of other manufacturers
based on the similarities and dissimilarities
between product offerings. It is not intended
to replace specific product literature for
Eaton products. Information contained in this
literature about other manufacturers’ product
is from written material and/or published, or
made available by the manufacturers.
CONFIDENTIAL —
For internal use only by Eaton and
authorized distributors.
This information is intended to provide a
comparative analysis between Eatons
products and those of other manufacturers
based on the similarities and dissimilarities
between product offerings. It is not intended
to replace specific product literature for
Eaton products. Information contained in this
literature about other manufacturers’ product
is from written material and/or published, or
made available by the manufacturers.
Proof 1 — July 2020
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Eaton YHH30B Series User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI