Lopi 430 EmberGlo Insert Owner's manual

Category
Fireplaces
Type
Owner's manual
430 Ember-Glo™
GSR2 Insert
Owner’s Manual
WARNING: FIRE OR EXPLOSION HAZARD
Failure to follow safet
y
warnin
g
s exactl
y
could result in serious in
j
ur
y
, death, or propert
y
dama
g
e.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Leave the building immediately
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
! DANGER
HOT GLASS WILL CAUSE
BURNS
DO NOT TOUCH GLASS
UNTIL COOLED
NEVER ALLOW CHILDREN
TO TOUCH GLASS
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and shall be installed for the protection of children
and other at-risk individuals.
Tested and Listed by
Report# G100518003PRT-002
ANSI Z21.88:19
CSA 2.33:19
Direct Vent Fireplace Insert
Masonry or Factory-Built
(Metal) Wood-Burning
Fireplace
Residential or Mobile Home
This appliance may be installed in an aftermarket, permanently located, manufactured home
(USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. A conversion
kit is supplied with the appliance.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
French language manuals at fireplacex.com. or
lopistoves.com
Manuels de langue Française à fireplacex.com or
lopistoves.com
Travis Industries, Inc. 12521 Harbour Reach Dr., Mukilteo, WA 98275 www.travisproducts.com
Copyright 2022, T.I. $10.00 4/26/2023 100-01521
2 Introduction
© Travis Industries 4/26/2023 - 1521 430 EG GSR2
Introduction
We welcome you as a new owner of a 430 GSR2 Insert. In purchasing this fireplace insert you have
joined the growing ranks of concerned individuals whose selection of an energy system reflects both a
concern for the environment and aesthetics. It is one of the finest home heaters the world over. This
manual will explain the installation, operation, and maintenance of this heater. Please familiarize yourself
with the Owner's Manual before operating your heater and save the manual for future reference. Included
are helpful hints and suggestions that will make the operation and maintenance of your new heater an
easier and more enjoyable experience. We offer our continual support and guidance to help you achieve
the maximum benefit and enjoyment from your heater.
Important Information
No other 430 EG GSR2 Insert has the same serial
number as yours. The serial number is below and to
the left of the gas control valve.
This serial number will be needed in case you require
service of any type.
Model: 430 EG GSR2
Serial Number:
Purchase Date:
Purchased From:
Register your warranty online at:
traviswarranty.com
Save Your Bill of Sale.
To receive full warranty coverage, you will
need to show evidence of the date you
purchased your heater.
We suggest that you attach your Bill of Sale
to this page so that you will have all the
information you need in one place should the
need for service or information occur.
Listing Details
This appliance was listed by Intertek. The listing label is attached to the appliance near the gas control
valve. A copy is shown on page 47.
Massachusetts Approval
This manual has been submitted to the Massachusetts Board of State Examiners of Plumbers and Gas Fitters.
National Fireplace Institute
Table of Contents 3
© Travis Industries 4/26/2023 - 1521 430 EG GSR2
Introduction ...................................................... 2
Important Information ...................................... 2
Listing Details ................................................... 2
Features ............................................................ 6
Installation Options .......................................... 6
Heating Specifications ..................................... 6
Dimensions ....................................................... 6
Electrical Specifications (for blowers) ........... 6
Fuel .................................................................... 6
Installation Warnings ....................................... 7
Packing List ...................................................... 7
Additional Items Required ............................... 7
Order of Installation ......................................... 7
Fireplace Requirements .................................. 8
Fireplace Clearances to Gas Insert ....................... 8
Masonry Fireplace Hearth Requirements ...... 8
Factory-Built (Metal) Wood-Burning Fireplace
Requirements ................................................... 9
Factory Built Fireplace Hearth Requirements9
Clearances ...................................................... 10
Mantel Clearances .............................................. 10
Vinyl Flooring Hearth Recommendations ... 11
Televisions Placed Above the Insert ............ 12
Leveling Bolts ................................................. 13
Electrical Requirements ................................ 14
Re-Routing the Power Cord to the Front of the
Insert ................................................................... 14
Using the Insert Wiring Kit................................... 14
Gas Line Requirements ................................. 15
Gas Inlet Pressure .............................................. 15
Gas Line Installation ...................................... 16
Vent Requirements ........................................ 17
Vent Installation ............................................. 18
Vent Location ................................................. 19
Vent Configurations ............................................ 19
Altitude Considerations ................................. 19
Vent Attachment – Tight Installations .......... 20
Exhaust Restrictor Settings .......................... 22
Glass Frame Removal and Installation ........ 25
Steps for Finalizing the Installation ............. 26
Before You Begin ........................................... 29
Remote Set-Up ............................................... 30
Starting the Heater for the First Time .......... 31
Location of Controls ...................................... 31
Direct Operation ............................................. 31
Continuous/Intermittent Pilot Switch ........... 32
Pilot Fuel Conservation Timer ...................... 33
Remote Operation .......................................... 34
Manual On-Off / Smart Thermostat / Standard
Thermostat ..................................................... 35
Mode Controls (Flame, Blower, Light,
Comfort Control, EmberBed Light) .............. 36
Mode Controls - continued ........................... 37
Display Fahrenheit or Celsius ...................... 37
Low Battery Indicator .................................... 38
Battery Replacement ..................................... 39
Power Outages ............................................... 39
Child-Proof Feature ....................................... 40
Normal Operating Sounds ............................ 40
Normal Operating Odors ............................... 40
Maintaining Your Heater's Appearance ....... 41
Accent Light Replacement ............................ 41
Ember-Glo Bulb Replacement ...................... 42
Yearly Service Procedure ............................. 44
Troubleshooting Table .................................. 45
Wiring Diagram .............................................. 46
Replacement Parts ........................................ 46
CONDITIONS & EXCLUSIONS ...................... 48
IF WARRANTY SERVICE IS NEEDED: ......... 48
LP Conversion Instructions .......................... 49
Fireback Installation ...................................... 52
Oak and Birch Log Set Installation (sku#
94500957, 94500956) ...................................... 56
Installation Warnings .................................... 56
Installation – Oak vs. Birch ........................... 56
Log Set Overview – Oak (sku# 94500957) ... 56
Log Set Overview – Birch (sku# 94500956) . 57
Log Set Installation ........................................ 58
Driftwood Log Set Installation (sku#
94500953) ........................................................ 66
Installation Warnings .................................... 66
Order of Installation ....................................... 66
Packing List .................................................... 67
Log Set Overview – Driftwood (sku#
94500953) ........................................................ 68
Log Set Installation ........................................ 68
4 Safety Precautions
© Travis Industries 4/26/2023 - 1521 430 EG GSR2
Failure to follow all of the requirements may result in property damage, bodily injury, or even death.
Young children should be carefully supervised when they are in the same room
as the appliance. Toddlers, young children, and others may be susceptible to
accidental contact burns. A physical barrier is recommended if there are at-risk
individuals in the house. To restrict access to a fireplace or stove, install an
adjustable safety gate to keep toddlers, young children, and other at-risk
individuals out of the room and away from hot surfaces.
Children and adults should be alerted to the hazards of high surface temperature
and should stay away to avoid burns or clothing ignition. Do not touch the hot
surfaces of the heater. Educate all children of the danger of a high-temperature
heater.
Due to the high temperature, the heater should be located out of traffic and away
from furniture and draperies.
This unit must be installed by a qualified installer to prevent the possibility of an explosion.
This appliance must be installed in accordance with all local codes if any; if not, in U.S.A. follow ANSI
Z223.1 and NFPA 54(88), in Canada follow CSA B149.1.
A manufactured home (USA only) or mobile home OEM installation must conform with the
Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a
standard is not applicable, the Standard for Manufactured Home Installations, ANSI/NCSBCS
A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4. This
appliance may be installed in Manufactured Housing only after the home is site located.
All exhaust gases must be vented outside the structure of the living area. Combustion air is drawn
from outside the living-area structure. The venting must not be connected to a chimney flue serving a
separate solid-fuel burning appliance.
Notify your insurance company before hooking up this fireplace.
The instructions in this manual must be strictly adhered to. Do not use makeshift methods or
compromise in the installation. Improper installation will void the warranty and safety listing.
This heater is approved for use with natural gas (NG) or propane (LP). Burning the incorrect fuel will
void the warranty and safety listing and may cause an extreme safety hazard. Direct questions about
the type of fuel used to your dealer.
Contact your local building officials to obtain a permit and information on any installation restrictions
or inspection requirements in your area.
If the flame becomes sooty, dark orange in color, or extremely tall, do not operate the heater. Call
your dealer and arrange for proper servicing.
It is imperative that control compartments, screens, or circulating air passageways of the heater be
kept clean and free of obstructions. These areas provide the air necessary for safe operation.
Do not operate the heater if it is not operating properly in any fashion or if you are uncertain. Call
your dealer for a full explanation of your heater and what to expect.
Do not store or use gasoline or other flammable liquids in the vicinity of this heater.
Do not operate if any portion of the heater was submerged in water or if any corrosion occurs.
Immediately call a qualified service technician to inspect the appliance and to replace any part of the
control system and any gas control which has been underwater.
Safety Precautions 5
© Travis Industries 4/26/2023 - 1521 430 EG GSR2
Safety Warnings (continued)
Because this heater can be controlled by a thermostat there is a possibility of the heater turning on
and igniting any items placed on or near the appliance.
Light the heater using the built-in igniter. Do not use matches or any other external device to light
your heater.
Never remove, replace, modify, or substitute any part of the heater unless instructions are given in
this manual. All other work must be done by a trained technician. Don't modify or replace orifices.
The viewing glass should be opened only for conducting service.
Allow the heater to cool before carrying out any maintenance or cleaning.
Operate the heater according to the instructions included in this manual.
If the main burners do not start correctly turn the gas off and call your dealer for service.
This unit is not for use with solid fuel.
Do not place anything inside the firebox (except the optional artwork).
Warning: Do not operate appliance with the glass front removed, cracked, or broken. Replacement
of the glass should be done by a licensed or qualified service person.
Do not throw this manual away. This manual has important operating and maintenance instructions
that you will need at a later time. Always follow the instructions in this manual.
Instruct everyone in the house how to shut the gas off to the appliance and at the gas main shutoff
valve. The gas main shutoff valve is usually next to the gas meter or propane tank and requires a
wrench to shut off.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this
appliance and shall be installed for the protection of children and other at-risk individuals.
If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this
appliance.
Clothing or other flammable material should not be placed on or near the appliance.
Any safety screen, guard, or barrier removed for servicing an appliance must be replaced prior to
operating the appliance.
Installation and repair should be done by a qualified service person. The appliance should be
inspected before use and at least annually by a professional service person. More frequent cleaning
might be required due to excessive lint from carpeting, bedding material, et cetera. It is imperative
that control compartments, burners, and circulating air passageways of the appliance be kept clean.
Travis Industries, Inc. grants no warranty, implied or stated, for the installation or
maintenance of your heater, and assumes no responsibility of any consequential damage(s).
6 Features and Specifications
© Travis Industries 4/26/2023 - 1521 430 EG GSR2
Features
- Works During Power Outages (battery backup system)
- Blowers and Remote Control Included
- Continuous or Intermittent (GreenSmart) Pilot
- Convenient Operating Controls
- Variable-Rate Heat Output
-
A
ccent Lights
Installation Options
Residential or Mobile Home
Fireplace Insert
Existing Masonry or Factory Built (Metal)
Wood-Burning Fireplace
Heating Specifications
Natural Gas Propane
A
pproximate Heatin
g
Capacit
y
(
in square feet
)
* 500 to 1,600 500 to 1,600
Maximum BTU Input Per Hour 31,000 31,000
* Heating capacity will vary with floor plan, insulation, and outside temperature.
Dimensions
Electrical Specifications (for blowers)
Electrical Rating 120 Volts, 1.8 Amps, 60 Hz (205 watts) (typical max amps: 5).
Fuel
This heater is shipped in natural gas (NG) configuration but may be converted to propane (LP) using
the LP Conversion Kit (included) and the LP stepper motor (SKU 250-01463, sold separately). The
sticker on top of the gas control valve will verify the correct fuel.
* See "Fireplace Requirements"
for minimum fireplace sizing.
21" *
(534mm) *
15" *
13-3/4"* if using panel trim.
(381mm) *
(350mm) *
29-1/2" *
(750mm) *
Small 38" (966mm)
Large 40" (1016mm)
Small 25"
(635mm)
Large 28-1/2"
(724mm)
19-1/2" *
(496mm) *
IDB1005
Installation (for qualified installers only) 7
© Travis Industries 4/26/2023 - 1521 430 EG GSR2
Installation Warnings
Failure to follow all of the requirements may result in property damage, bodily injury, or even death.
This heater must be installed by a qualified installer who has gone through a training program
for the installation of direct vent gas appliances.
The installation must conform with local codes or, in the absence of local codes, the National
Fuel Gas Code, ANSI Z223.1/NFPA 54, or the National Gas and Propane Installation Code, CSA
B149.1.
In Manufactured or Mobile Homes must conform with Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable, the
Standard for Manufactured Home Installations, ANSI/NCSBCS A225.1. This appliance may be
installed in Manufactured Housing only after the home is site located.
The heater is designed to operate on natural gas, or propane (LP).
All exhaust gases must be vented outside the structure of the living area. Combustion air is
drawn from outside the living-area structure.
Notify your insurance company before hooking up this heater.
The requirements listed below are divided into sections. All requirements must be met
simultaneously. The order of installation is not rigid – the qualified installer should follow the
procedure best suited for the installation.
Packing List
Propane (LP) Conversion Kit
Remote Control
"Fireplace Altered" tag (attach to the fireplace)
46” Flex Line with Adapter and Shutoff Valve
Additional Items Required
Faceplate
3" Diameter Gas Liner with Termination (Kit – sku# 96200339)
Gas Line Equipment (shutoff valve, pipe, etc.)
Panel Kit
Fireback Kit
Media
If using LP (propane) a conversion kit is required (sku# 250-01463 – GSR Stepper Motor Kit).
Stove Bright® Metallic Black touch-up paint
Order of Installation
1. Run gas line to the fireplace.
2. Remove the glass frame.
3. Run vent through fireplace chimney. On larger fireplaces, the vent connector may be left in place. For
smaller fireplaces, remove the vent connector. See “Vent Connector Removal and Installation” for details.
4. Place insert into position and attach the gas line and vent.
5. Remove the burner.
NOTE: If using propane (LP), convert the appliance at this time.
6. Install the firebacks.
7. Replace the burner.
8. Install the media (logs, stones - see instructions included with the media).
9. Install the surround panel (see instructions included with surround panel).
10. Follow the instructions under “Finalizing the Installation.”
8 Installation (for qualified installers only)
© Travis Industries 4/26/2023 - 1521 430 EG GSR2
Fireplace Requirements
Insert must be placed within a code-conforming masonry fireplace or tested and listed factory-built
(metal) wood-burning fireplace. Repair any fireplace damage prior to installation.
Because the insert uses a circulation blower, clean the fireplace, smoke shelf, and chimney prior to
installation.
This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance
produces when determining a location.
Do not place insulation or any other material on top of the insert. This may block the upper accent
light ventilation, leading to premature bulb failure.
Fireplace Sizing 1-Piece Panel 1-Piece Panel w/ Trim
Minimum Height 20-1/4” (515mm) 19-3/4” (502mm)
Minimum Width 30-1/2” (775mm) 30-1/4” (768mm)
Minimum Depth 15-1/2” (394mm) 14-1/4” (357mm)
Minimum Hearth
Depth (see “Hearth
Requirements” on
the following page
for full details)
0” (0mm) 0” (0mm)
Extension onto
Hearth 0” (0mm) 1-1/4”(32mm)
The gas and electrical line should be installed prior to installing
the heater.
For tight fits (under 24”) see the section “Removing the Vent
Connector”.
See “Leveling Legs” for details on leveling the heater.
I Attach the “This fireplace has been altered…” plate to the fireplace (use two screws or other suitable method). You may
wish to place it in a location where it will be covered by the surround panels.
Fireplace Clearances to Gas Insert
Side of Insert to Inside of Fireplace ½” (13mm)
Back of Insert to Inside of Fireplace ½” (13mm)
Top of Insert to Inside of Fireplace 3/4” (20mm)
Masonry Fireplace Hearth Requirements
A panel trim kit is available for this appliance. When using the kit, the appliance will sit forward of the fireplace
opening 1-1/4” (32mm).
WARNING:Anoncombustiblehearthisnotrequiredinfrontoftheappliance.However,iftheheaterisinstallednextto
thefloor,werecommendahearthtoprotecttheflooringsurfacefromdiscolorationorothernegativeimpacts
fromtheheater.
a
b
c
f
g
d
I
h
e
a
b
c
d
e
f
g
h
Installation (for qualified installers only) 9
© Travis Industries 4/26/2023 - 1521 430 EG GSR2
Factory-Built (Metal) Wood-Burning Fireplace Requirements
The damper ("A") and grate (with log set) ("B") must be removed (see the illustration below)
The smoke shelf ("C"), internal baffles ("D"), screen ("E"), masonry lining or refractory ("G" & "I"), and
metal or glass doors ("F") may be removed (if applicable)
The fireplace must be permanently marked to
indicate that it has been altered and is no longer
suitable for burning solid fuel (wood) unless the
removed parts are re-installed. Cutting of any
sheet metal parts is prohibited.
The metal floor (“J”) of the firebox may be removed
in certain cases*.
The insulation ("H"), and any structured rigid frame
members must not be removed or altered (side and
top of door frame, side, and top of the face of the
fireplace, metal sides, etc.).
*CAUTION – Removal of the firebox floor of a factory-built solid fuel fireplace in order to accommodate the
installation of a gas-fired fireplace insert is not covered under (ANSI Z21.88 – CSA 2.22 or ANSI Z21.50 – CSA
2.33) standard(s) used to certify the gas-fired fireplace insert or UL 127 and ULC S627 standards used to
certify solid fuel factory-built fireplaces. The Intertek safety certification will not apply to this installation method.
This installation method must be deemed acceptable by the Authority Having Jurisdiction (AHJ) prior to the gas-
fired fireplace insert being installed. The sheet metal base (or metal wrap) of the fireplace must be left in place
and a minimum ½” cement board sheet placed under the entire length and width of the appliance.
If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1-1/2 inch (37.5 mm) or
less may be drilled through the lower sides or bottom of the firebox in proper workmanship like
manner. This access hole must be plugged with non-combustible insulation after the gas supply line has
been installed.
Factory Built Fireplace Hearth Requirements
½” of non-combustible material is required underneath the entire footprint of the insert.
WARNING:
A non-combustible hearth is not required in front of the appliance. However, if the heater is installed next to the
floor, we recommend a hearth to protect the flooring surface from discoloration or other negative impacts from
the heater.
C
B
F
I
D
E
A
G
H
J
10 Installation (for qualified installers only)
© Travis Industries 4/26/2023 - 1521 430 EG GSR2
Clearances
Due to the high temperature of the heater, it should be located out of traffic and away from furniture and
draperies.
Minimum
Clearances
k Sidewall to Insert 5" (127mm)
l Side Facing
(
non-combustible
)
3-3/8 " (86mm)
m Top Facing*
(
non-combustible
)
32-3/8" (823mm)
n 12” Mantel* (combustible
or non-combustible
)
34-1/2" (877mm)
n 4” Mantel* (combustible
or non-combustible
)
33-1/2" (851mm)
p Hearth Extension to the
Front of Insert
0" (0mm)
x Extension onto Hearth
1 Piece Panel
1 Piece Panel w/Trim Kit
0" (0mm)
1-1/4” (32mm)
* Measured from the base of the insert.
NOTE: the non-combustible top facing must
extend 32-3/8” (823mm) above the base of
the insert or to the bottom of the mantel
(whichever is less).
Mantel Clearances
The maximum mantel depth is 12” (305mm).
NOTE: The combustible area above the non-combustible facing must not protrude more than 3/4"
(20mm) from the facing. If it does, it is considered a mantel and must meet the mantel requirements
listed in this manual.
Side
Wall
Combustible or Non-Combustible Mantel
Combustible Top Facing
Non-Combustible
Facing
l
k
x
n
m
p
IDB1007
35"+(889mm+)
33"(839mm)
32"(813mm)
31"
(
788mm
)
34"(864mm)
0"
1" (26mm)
2" (51mm)
8" (204mm)
7" (178mm)
6" (153mm)
5" (127mm)
4" (102mm)
3" (77mm)
9" (229mm)
10" (254mm)
11" (280mm)
12" (305mm
)
M
ax
i
mum
M
an
t
e
l
D
ep
th
antel Height
Above Base
of Fireplace
Installation (for qualified installers only) 11
© Travis Industries 4/26/2023 - 1521 430 EG GSR2
Vinyl Flooring Hearth Recommendations
Vinyl flooring such as Luxury Vinyl Plank (LVP), Luxury Vinyl Tile (LVT), and other vinyl flooring can be sensitive
to radiant heat and changes in temperature. If using vinyl flooring, we recommend installing the insert following
the guidelines below. If these recommendations are not followed, the heat from the fireplace may cause
discoloration, warping or other negative impacts.
NOTE: If using one of the hearth options, make sure to maintain the gap recommended by the manufacturer between
the flooring and the hearth. Seal the gap with a flexible caulk to allow for expansion and contraction of the flooring.
Install the insert at floor level with a 27”
(686mm) deep flush hearth (either combustible
or noncombustible). The minimum width of the
hearth is equal to the width of the fireplace
openin
g
.
The insert is elevated 12” (305mm)
above the vinyl floor. No hearth is
required. The vinyl flooring can be
installed up to the wall or front of
hearth if one is present.
Determine the height that the
Insert will sit above the finished
floor and use the chart below to
determine the minimum
recommended hearth depth.
12 Installation (for qualified installers only)
© Travis Industries 4/26/2023 - 1521 430 EG GSR2
Televisions Placed Above the Insert
The following section gives guidelines to place a television above the insert.
IMPORTANT NOTE REGARDING TELEVISIONS AND THIS INSERT
Most television manufacturers instruct the homeowner not to place the television above a heat source like this insert.
Doing so may decrease the longevity of the television and negate the warranty. If you do place a television above the
insert, you should place a mantel between the insert and television. Follow the guidelines below to reduce the
amount of heat reaching the television. Travis Industries does not take responsibility for any negative impact on
televisions placed near this insert.
Minimum Dimensions:
(a) Minimum Mantel Height above Base of Insert* 34” (864mm) with 8” (204mm) mantel depth
(b) Minimum Mantel Depth* 8” (204mm)*
* Minimum mantel depth must be 8”(204mm) to allow heat to dissipate. If using a mantel larger than 8”
(204mm), make sure to adjust the mantel height (a) to meet the mantel clearance (see mantel requirements
on page 10 for details).
The mantel must extend 2” in front of the television and 1” to both sides.
If you have a television that is greater than 6” deep (including the 1” gap behind), you will need to alter the
mantel depth and height (see the example below).
The television must have a 1” gap to the wall to allow for proper cooling.
WIRING NOTE: If running wiring into the enclosure, use thermal insulating wrap around the wiring. Secure the wiring
to protect from contact with hot surfaces.
Min. 1" (26mm)
Min. 1" (152mm)
Min. 2" (51mm)
b
Television (TV)
TOP
(4) AA Batteries
FU
SE
FU
SE
FU
SE
a
36"+(915mm+)
34"(864mm)
430 EG
35"(889mm)
0"
1" (25mm)
2" (51mm)
8" (203mm)
7" (178mm)
6" (152mm)
5" (127mm)
4" (102mm)
3" (76mm)
9" (229mm)
10" (254mm)
11" (279mm)
12" (305mm)
(b) Depth
Height
Above
Base of
Fireplace
(a)
Installation (for qualified installers only) 13
© Travis Industries 4/26/2023 - 1521 430 EG GSR2
Leveling Bolts
This heater includes front and rear leveling legs to accommodate fireplaces with a step-down firebox.
Loosen the (4) bolts and adjust the legs down until the insert is properly supported and level.
14 Installation (for qualified installers only)
© Travis Industries 4/26/2023 - 1521 430 EG GSR2
Electrical Requirements
Travis Industries manufactures a wiring kit specifically for inserts (sku 97200315). This kit allows installers to
wire 120 volt AC power into a fireplace directly to the insert, eliminating the need for an external power cord.
Plug the power cord into a grounded 120 Volt outlet (do not remove the grounding pin).
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.
Do not route the power over the appliance or near any hot or moving components.
Re-Routing the Power Cord to the Front of the Insert
The power cord is shipped attached to the side of the insert. It may be routed to the front where it exits
behind the face but in front of the surround panel. See the directions below for details.
Using the Insert Wiring Kit
See the instructions included with the wiring kit for attaching the kit to the side of the insert.
Remove the side
access panel.
Use pliers to remove
the strain relief.
a
b
Disconnect the
molex connection
Reconnect the
Reinstall the
access panel
molex connection.
and remove the
power cord.
e
d
a
Route wires through the
front mounting bracket.
Use pliers to reinstall the
strain relief.
d
c
Remove the side
access panel.
Use pliers to remove
the strain relief.
a
b
Disconnect the
molex connection
and remove the
power cord.
e
Attach the hard wire kit to
insert (see kit instructions for details).
a
d
c
Reconnect the Molex connector
and replace the access panel.
Installation (for qualified installers only) 15
© Travis Industries 4/26/2023 - 1521 430 EG GSR2
Gas Line Requirements
MASSACHUSETTS INSTALLATIONS - WARNING:
THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUMBER OR GAS FITTER WHEN INSTALLED WITHIN THE
COMMONWEALTH OF MASSACHUSETTS.
OTHER MASSACHUSETTS CODE REQUIREMENTS:
Flexible connector must not be longer than 36 inches.
Shutoff valve must be a “T” handle gas cock.
Only direct vent sealed combustion products are approved for bedrooms or bathrooms.
Fireplace dampers must be removed or welded in the open position prior to the installation of a fireplace insert or gas log.
A carbon monoxide (CO) detector is required in the same room as the appliance.
The gas line must be installed in accordance with all local codes if any; if not, follow ANSI 223.1 and
the requirements listed below.
A manual shutoff valve is required within 3’ of the heater. It should be placed upstream of the flex line
(if used) and may be installed behind the access door inside the heater.
The heater and gas control valve must be disconnected from the gas supply piping during any
pressure testing of that system at test pressures in excess of 1/2 psig. For pressures under 1/2 psig,
isolate the gas supply piping by closing the manual shutoff valve.
Leak test all gas line joints and the gas control valve prior to and after starting the heater.
This heater is designed either for natural gas or for propane (but not for both). Check the sticker on
the top of the gas control valve to make sure the correct fuel is used (see illustration on page 4).
Installation must be performed by a qualified installer, service agency, or the gas supplier (In
Massachusetts a licensed plumber/gas-fitter).
Gas Inlet Pressure
Gas Pressure
Max. Input Pressure Min. Input Pressure Max. Manifold Pressure Min. Manifold Pressure
Natural Gas
7" W.C. (1.74 kPA) 5.5” W.C. (1.37 kPA) 3.5” W.C. (0.87 kPA) 1.6” W.C. (0.40 kPA)
Propane
13" W.C. (3.23 kPA) 11” W.C. (2.74 kPA) 11” W.C. (2.74 kPA) 2.9” W.C. (0.72 kPA)
If the pressure is not sufficient, make sure the piping used is large enough, the supply regulator is
adequately adjusted, and the total gas load for the residence does not exceed the amount supplied.
The supply regulator (the regulator that attaches directly to the residence inlet or to the propane tank)
should supply gas at the suggested input pressure listed above. Contact the local gas supplier if the
regulator is at an improper pressure.
16 Installation (for qualified installers only)
© Travis Industries 4/26/2023 - 1521 430 EG GSR2
Gas Line Installation
1. Route the included flex tube through the hole in the left side of the insert and out the front as shown below.
2. Bend the flex tube up.
3. Attach the included gas shutoff valve to the end of the flex tube and gas inlet as shown below.
Position so the valve handle is on the right as shown.
Leak-test all gas line connections.
Installation (for qualified installers only) 17
© Travis Industries 4/26/2023 - 1521 430 EG GSR2
Vent Requirements
Travis Industries manufactures a vent kit specifically for this insert (sku
96200339). It includes 30’ (10M) of vent, hose clamps, and a high wind
cap. The flashing on the cap is 18” (458mm) by 18” (458mm).
Travis Industries manufactures a vent kit specifically for this insert (sku
96200330). It includes 30’ (10M) of vent, hose clamps, and a prairie
cap. The flashing on the cap is 18” (458mm) by 18” (458mm).
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to
a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas appliance must use its own
separate vent system.
Make sure the exhaust pipe on the heater connects to the exhaust portion of the cap. The illustrations below show
how the flex liners should be attached.
The exhaust vent must reline the entire length of the chimney and terminate above the chimney top.
Be careful not to crimp or rupture the liner when bending it into chimney offsets.
When installed, the vent must meet all of the vent manufacturer's requirements.
Use the following vent:
3” UL 441 or 1777 Gas Liner for Exhaust, 3” UL 441 or 1777 Gas Liner for Air Inlet
DuraVent 6-5/8” to 3” Co-Linear Adapter and Flashing (46DVA-Gk)
DuraVent High-Wind Vertical Termination (46DVA-VCH) for high-wind applications or Prairie Cap
Drafting Performance
This direct vent appliance requires natural draft to operate (similar to a wood stove or other heating appliance). Draft
can be adjusted using the included restrictor. The restrictor settings detailed in the manual should be followed
(variations may occur depending upon installation parameters).
Many factors may negatively influence the draft of the appliance. Travis Industries will not be responsible for improper
draft due to factors such as trees, hills, buildings, obstructions, excessive wind, extreme hot or cold outdoor
temperatures, restrictive vent terminations, or influence from mechanical systems.
Max. Ht. 40' (12.2M)
Min. Ht. 16' (5M)
Max. 4'
(1.2M)
offset
18 Finalizing the Installation
© Travis Industries 4/26/2023 - 1521 430 EG GSR2
Vent Installation
Secure the vent to the insert and termination kit using screws.
For optimum performance, keep the vent as straight as possible (no 90 bends).
Inlet (3" 76mm)
Exhaust
(3" 76mm)
Inlet
Exhaust
3" (76mm) dia. Gas Liner
Inlet Exhaust
Additional Coaxial
Sections May Be Added
(support as needed)
Approved
Cap
Finalizing the Installation 19
© Travis Industries 4/26/2023 - 1521 430 EG GSR2
Vent Location
An Exhaust Restrictor is built into the appliance to adjust the flow rate of exhaust gases. This
ensures proper combustion for all vent configurations. Depending upon the vent configuration, you
may be required to adjust the restrictor position. See “Exhaust Restrictor Settings” on page 22.
Vent Configurations
Altitude Considerations
This heater has been tested at altitudes ranging from sea level to 6,000 feet (1,800 M). In this
testing, we have found that the heater, with its standard orifice, burns correctly with just an air shutter
adjustment.
Failure to adjust the air shutter properly may lead to improper combustion which can create a safety
hazard. Consult your dealer or installer if you suspect an improperly adjusted air shutter.
Inlet
Z.C. (Metal) Wood-Burning Fireplace
Inlet & Exhaust Re-Line Exhaust Only Re-Line
Recommended Block-Off
Plate (non-combustible
metal and/or insulation).
Prevents odors from
chimney entering room.
A block-off plate must
seal the intake to the
chimney space. This
way air is drawn down
the chimney for
combustion air.
Block-Off Plate
(non-combustible
materials)
NOTE: You may use either re-line configuration with a masonry or zero-clearance fireplace.
Inlet
Masonry Fireplace
Any cracks or
damage inside the
chimney must be
repaired.
Exhaust
20 Finalizing the Installation
© Travis Industries 4/26/2023 - 1521 430 EG GSR2
Vent Attachment – Tight Installations
The vent connector is shipped attached to the insert but must be removed to facilitate tight
installations. See the directions below for installation.
1. Locate the screw in the top-center of the front of the insert. Use a ¼” nut driver to remove the screw
and slide the connector toward the back of the insert to disengage the connector from the top of the
insert.
2. Stretch the liners to their full length. Attach the flex liners to the cap (secure with screws). Route the
flex vent through the chimney from above.
1/4" Nutdriver
R
emove Screw
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80

Lopi 430 EmberGlo Insert Owner's manual

Category
Fireplaces
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI