Potter SL24W-1530 Select-A-Strobe Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the Potter SL24W-1530 Select-A-Strobe Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
SL24W-1530
SELECT-A-STROBE
Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 631464161 • Phone: 8003253936/Canada 8888821833 • www.amsecokai.com
MKT. #8850010 - REV B
9/07 PAGE 1 OF 2
PRINTED IN USA
•MeetsorexceedsNFPA/ANSIStandardsandADAAccessibilityGuidelines
•ULListedforwallmounting   
•ScrewterminalcapacityuptoAWG12 
•Universalmountingplateincluded
•24VDCstrobewithtwofieldselectablesettings:15cdor30cd
•Polarizedstrobeswithwideoperatingvoltagerangeusingfilteredor
unfilteredFWRinputvoltage
•Mountsto4”square,singlegang,doublegang,oroctagonalbackbox
•Tamperproofcandelaselectorswitch
•SynchronizationrequiresSyncModule(SMD103A)
•Availableinredorwhitehousing
Amseco’sSelectAStrobeSeriesisdesignedtocomplywiththeAmericanswithDisabilitiesAct(ADA)andmeetULstandard1971
requirements for emergency signaling devices for the hearing impaired.
TheSelectAStrobeSL24Wseriesfeaturesauniquecandelaintensityfieldselectorswitchforalternatingthecandelaoutput15cdto30cd
(75cdonaxis).Thestrobehousingisclearlylabeledwithvertical“FIRE”lettering.Thestrobeispolarizedforconnectingtosupervisedfire
alarmcircuitsandisdesignedwithaxenonflashtubetoprovidemaximumperformancewithacandelaintensityfieldselectorswitch.
The SL24W-1530 can be synchronized by using the SMD10-3A Sync Module to comply with NFPA recommendations concerning
photosensitiveepilepsywheninstallingtwoormorevisualapplianceswithinthefieldofview.Thestrobesignalsarelistedforindooruse,wall
mount, under UL 1971 standard.
Model Number Housing
Color Input
Voltage Operating
Vo lta ge Ra nge Selectable
Strobe Output Flash Rate Wiring
Type Mounting
Type Sync
Module
Operating
Temperature
Range
SL24W-1530R Red Regulated
24V DC/
FWR
16 - 33V DC
16 - 33V FWR 15cd or 30cd 60 times/
min. Terminals Wall
Mount SMD10-3A 32°F - 120°F
(0°C - 49°C)
SL24W-1530W White
EngineeringSpecifications
The visual alarm indicating appliance shall be Amseco model SL24W-1530 or equivalent device. The strobe shall be listed under UL 1971
standardforsignalingdevicesforthehearingimpairedandshallbeapprovedforfireprotectiveservice.ForoutdoorapplicationandinUL
NEMA-4X rated or UL Haz Dust Tight condition, use Amseco UL/ULC ESH1229/1229HTR polycarbonate covers. The candela output shall
befieldselectable,havingadualsettingof15cdor30cdoutput.Thesignalingstrobeshalloperateon24VDCfromanoncodedregulated
DCsupplyorfullwaverectified,unfilteredsupply.Thestrobeshallbedesignedtoproduceonesignalflashpersecondwithcontinuously
applied minimum voltage. The strobe shall have a universal back mounting plate, capable of wall mounting to a back box. When strobe
synchronization is required, the strobe shall be compatible with Amseco SMD10-3A (daisy chain) or other source of Amseco sync protocol.
Visual signaling devices shall be installed in accordance with current NFPA guidelines.
Ordering Information
Strobes must be used only on circuits with continuously operating
voltage. DO NOT use strobe on coded or interrupted circuits in which the
appliedvoltageisinterruptedONandOFFasthestrobemayfailtoash.
The applied voltage must be within its rated input voltage range.
Fuse ratings on signaling circuits must handle peak currents from all
devices connected to those circuits.
firealarmresources.com
MKT. #8850010 - REV B
9/07 PAGE 2 OF 2
PRINTED IN USA
Wiring Diagram
SL24W-1530
SELECT-A-STROBE
Installation
Dimensions: inches (mm)
Universal
Mounting
Plate
SL24W
Universal
Mounting Plate
SL24W
Universal
Mounting Plate
SL24W
4SP-M
Single Gang Box 4”SquareBackBox Double Gang Box 4BX-1
SL24W
Strobe Light
Specifications
Max. RMS
Operating Current
Regulated
24V DC Regulated
24V FWR
15cd 83 120
30cd 128 175
Under ULC
525/526 ULC Current at
24V DC (mA)
15cd 99
30cd 129
UL Required Minimum
Light Output Horizontal Vertical
Sound
Output
Dispersion
Horizontal
dB Ver ti ca l
dB
firealarmresources.com
/