Unbranded E2 Product information

Category
Motorcycle Accessories
Type
Product information
Models: E2EB-015HB
7103180 (Replaces 7102470)
WIRING DIAGRAM
Optional 4-Speed
Blower
!
WARNING
Switch circuit breakers to the “off”
position before servicing the furnace.
Notes :
See unit data label for
recommended supply wire sizes.
Thermostat anticipator setting :
0.50 Amps
To change blower speed on units
without a relay box installed refer
to installation instructions
Refer to furnace and/or relay box
installation instructions for
thermostat connections.
If any wire in this unit is to be
replaced it must be replaced with
105 C thermoplastic copper wire
of the same gauge.
Not suitable for use on systems
exceeding 120V to ground.
This wire is used with some
accessories. See accessory
Installation Instructions for further
detail.
Refer to Installation Instructions
for complete wiring diagram.
1)
2)
3)
4)
5)
6)
7)
8)
IFR1
Cont
1
LS
IFR2
240V
Cont 1
CB-A
CB-B
CB-B
Transformer
Top - 15.0
E
24V
Red
White
Green
Grey
E
Fuse
CB-A
White Jumper Wire
(See note 7)
6 Org.
4 Speed
Cont 1
Grey
Black
Blue
Yellow
Red
2
3
4
5
1
ML
C
IFM
H
MH
L
IFR2
IFR1
LS
CB = Circuit Breaker
E = Heater Element
IFR = Fan Relay
IFM = Fan Motor
Cont = Contactor
LS = Limit Switch
Legend:
= Fan Plug
  • Page 1 1

Unbranded E2 Product information

Category
Motorcycle Accessories
Type
Product information

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI