S42 P

Danfoss S42 P Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Danfoss S42 P Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
B016
D91
B016
D
D032
(torque to 30-70 ft•lbs)
D91
D92
(torque to 30-70 ft•lbs)
D91
D91
D032
D
D92
From
To
From
To
Removal of the control spool spring
1. Clean the external surfaces of the pump.
2. Remove the control spool bore plug (item B016)
with a 5/16 in internal hex wrench.
3. Remove the control spool bias spring (item D91).
Installing the Upgrade Bias Spring
4. Assemble the spring guide to one end of the
upgrade spring (item D91).
5. Install the spring and guide assembly into the
control spool bore noting proper orientation.
6. Install the new control spool bore plug (item
D032) using a 7/8 in wrench and torque to [40-95
Nm (30-70 ft
lbf)].
7. Repeat the procedures 1 thru 6 on the second
pump of the tandem unit.
Final Adjustments
8. If the control neutral needs adjustment, refer to
BLN-10093 for proper procedure.
Old Spring New Spring
Free Length 2.8 in 3.35 in
I.D. 0.495 in 0.433 in
Spring Identification
© Danfoss, 2013 BLN-10158 Rev AA • September 2013 1
Service Kit Instructions
Series 42
Control bias spring upgrade
/