TEC EMl-31055 User manual

Category
Kitchen scales
Type
User manual

This manual is also suitable for

Operations Manual
TEC LOAD CELL SCALE
(WITH LABEL PRINTER)
MODEL SL66
SERIES
.
(US-V
Version)
r&c TEC CORPORATION
EMl-31055
WARNING
This equipment generates, uses, and can radiate radio frequency energy and if not installed
and used in accordance with the instruction manual, may cause interference to radio
communications. It has been tested and found to comply with the limits for a Class A
computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to
provide reasonable protection against such interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause interference
in which case the user at his own expense will be required to take whatever measures may
be required to correct the interference.
EMl-31055
TABLE OF CONTENTS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
Page
l
INTRODUCTION
.............................................
1
.
PRECAUTIONS
.............................................
1
.%‘EClFlCATlONS
..............................................
2
OVERVIEW
.................................................. 3
REMOTEDISPLAY
............................................. 3
KEYLAYOUT
................................................. 4
KEY AND LAMP FUNCTIONS
.....................................
4
CONTROL LOCK
.............................................. 7
LEVEL ADJUSTMENT
........................................... 8
CLEANING THE PRINT HEAD
..................................... 8
REMOVAL AND REPLACEMENT OF LABEL ROLL ...................... 9
NOTES BEFORE STARTING OPERATIONS
...........................
10
OPERATION PROCEDURE
.......................................
11
1 I- 1. Weighed Article Registration ................................. 11
1 l- 2. By Count Registration
..................................... 13
1 l- 3. Fix Price Registration
...................................... 15
1 l- 4. Preset Count Registration
and Operation
........................
17
1 l- 5. Issuing Net Weight Label ................................... 22
1 l- 6. Tare Function Procedure ................................... 24
1 l- 7. SAVE Key Operation Sample ................................ 27
1 l- 8. VOID Key Operation Sample ................................. 28
1 l- 9. Date Change
............................................ 29
1 l- 10. Selection of Print Item on Registration Label
..................... 30
1 l- 11. Setting Automatic Display Switching Time .......................
31
11-12. Calling and Printing Grade Line ...............................
32
1 l- 13. Calling and Printing Logo
................................... 33
1 l- 14.
FUN Automatic Reception ..................................
34
TOTAL OPERATION PROCEDURES ................................ 36
12- 1. Hourly Report ...........................................
36
12-
2. Grand Total Report
.......................................
37
12- 3. PLUReport ............................................. 38
12- 4. Combination Report
.......................................
42
ACTION FOR ERROR MESSAGES ................................. 4%
LABEL PRINT FORMATS
........................................
46
BEFORE YOU CALL FOR SERVICE ................................. 50
16. APPENDIX
. . . . . . . . . . . . . . . . . . . . ..~.............................. 51
--m,
l-14-10 Uchlkanda, Chlyoda-ku. Tokyo, JAPAN
EMl-31055
INTRODUCTION
We
thank you very much for purchasing the TEC Electronic SL66 Series Scale.
This series has been designed with TEC reliability to offer a cost efficient system for a modest
investment.
The SL66 (with thermal printer)
takes advantage of the latest
technology in microprocessors. Because
of this, the decreased cabinet size permits the system to
be
placed
virtually anywhere in your store.
Your deli
and specialty departments can enjoy these high quality reliable TEC products. Improve your
operating effectiveness and watch the increased utilization of your front end scanning investment. This
electronic
Load Cell scale eliminates all moving parts and furnishes an accurate digital display of all
information.
We believe that your needs will now be fully satisfied, and you will have total reliability in price
calculation. Should you have any questions concerning the scale, please refer to this manual. Be sure
to keep this manual for future reference.
PRECAUTIONS
1. DON7 SUBJECT the weighing
platter to SUDDEN SHOCKS.
4. NEVER USE THINNER OR OTHER
VOLATILE SOLVENT for cleaning.
2. DON’T PRESS THE KEYS TOO
HARD.
Keys will operate correctly if they
are merely touched lightly.
5. DON‘T POUR WATER directly on
scale
7. When in use, avoid locations subject to vibration and direct sunlight.
4
3. Clean the cover and platter by
wiping with a dry cloth or a
cloth soaked with detergent
and wrung out thoroughly.
6. To ensure the scale is operat-
ing correctly, place a known
weight on the platter and
check for correct cornouting.
8. After the end of daily work, turn
the power OFF, then clean and
inspect the exterior of the scale
to allow you to use the scale at
its best condition.
1. SPECJFICATIONS
Items
Maximum Capacity
Minimum Scale Division
Using Weight Range
Display Range
Tare
Unit Price presettable
Minimum Price Display
Power Requirement
Current Consumption
Temperature Limits
Relative Humidity
Dimensions (approx.)
Weight
Remote Display
Weight
Unit Price
Total Price
Message
Display Designations
Remote Display Mode
Capacity of PLU Memory
Print Head
Label Issuing Method
Label
Interface Device (option):
Cassette Magnetic Tape Loader
PC Keyboard
SL66-3OL-US-V
30 Ibs
0.01 Ibs.
0.20 - 30 lbs.
O- 30.05 Ibs
0.0 1
- 30 Ibs.
$0.0 1 - 99.99
$0.0 1
AC 120V ? lo%, 60 Hz
12OV 1.5A 60 Hz
32” - 104°F
35% - 85% RH (No condensation)
15.7” (w) X 17.2” (D) X 18.7” (H)
33.1 Ibs.
4 digits
4 digits
5 digits
22 charactors (16 X 176 dot matrix)
NET, PREPACK, ERROR
Dual sides
Refer to below table.
Thermal Print Head
On-demand/Batch
RICOH 120LA or equivalent
AIWA DR-1
A FUJITSU PC Keyboard (FKB-2831-001) instead of the
IBM PC-XT Keyboard can be used. For use of other units,
please contact your TEC representative.
Capacity of PLU Memory
Option Kits
We
Capacity of
PLU
us-v
Max. 1400 PLUS
Name of Kit
OP-66-32K
OP-66-TMCC
OP-66-PCKEY
KS-60- 1
OP-66-PL
OP-66-PL-TMCC
OP-66-PIGGY
MC-l 28-EX
MC-256-EX
EMl-31055
Purpose
Expansion RAM Kit
Communication I/F Kit
(TMCC-3)
IBM PC-XT keyboard connec-
tion adapter
Label cassette case
Program Loader
Program Loader with Com-
munication I/F (TMCC-3)
Expansion RAM board
Memory Card (128 KB)
Memory Card (256 KB)
TMCC =
TEC
Multi-drop
Communication Control
-2-
EMl-31055
2. OVERVIEW
Remote
display
switch
.Power
Speed keyboard
L-- Operation keyboard
3. REMOTE DISPLAY
COMMODITY NAME
1
1
stable
leg
-3-
EMl-31055
4. KEY LAYOUT
FEED
:& TEST ZERO MSG
‘ROG N;fuT VOID
I I
NOTE: The characters (1 - 90) indicated on the speed keys are shown for the convenience of
explanation in this manual. The indications on the actual unit are not as shown in this illustration.
5. KEY AND LAMP FUNCTIONS
Name of Key & Lamp
Mode Switch (I)
AUTO
r
MANUAL
Mode Switch (2)
WEIGH
FIX
Function
“AUTO” position:
This position is used to issue regular scale labels.
When the weight becomes stable, the label will automatically be
issued.
“MANUAL” position:
When the weight becomes stable, the label will be issued by
depressing the a Key.
“WEIGHT” position:
This position is used in the weighing function of the SL66.
“FIX” position:
The Unit Price is entered directly to the Total Price on calling up
PLU, and that
Total Price cannot be changed by any subsequent weighing.
BY COUNT
“BY COUNT” position:
It is possible to produce labels which contain information on quantity
pricing, instead of weight.
NUMERIC Keys
These keys are used to enter PLU Number, Unit Price, and Tare weight.
cl
0 -
1
(9j
-4-
Name of Key & Lamp
Function
CLEAR Key
This key is used for clear-entry of numeric keys, return the scale
0
C
condition to the normal weighing mode, release the scale from the
SAVE or ERROR mode, and suspend batch printing.
TARE Key
Ll
T
r
PLU Key
El
PLU
PRINT/VERIFY Key
c
PRT/.
l/2 Key
cl
l/2
l/4 Key
0
l/4
SAVE Key
c
SAVE
This key is used to subtract tare weight.
--.-I-. 4--
This key is used to select a PLU number or return to the initial mode.
For issuing Total labels.
If the Label issue mode switch is set to the MANUAL position, it has
the function of label issue.
It is also used to resume batch printing if it has been suspended.
These keys are used to calculate the unit price by 1/2lbs or 1/4lbs.
This key is used to save tare and unit price after removing the
commodity from the platter.
DATE & TIME Key
DT
szl
M
GRADE LINE Key
GRADE
Cl
LINE
This-key is used for temporary date changes.
This key is used to call the grade line message.
In the “X” or “2” control lock position, this key is used to generate the
Zone Total Report.
VOID Key One article’s data can be cancelled by depressing this key after its
It is also used to return the operation step to the previous step.
NEXT PLU Key
NEXT
c
PLU
This key is used to call out the next PLU #, and forward the operation
step to the next step.
C
0
In the “X”or “Z” control lock position, this key is used to generate the
Block Total Report.
In the “REG.” control lock position, this key is used to select whether
the data should be printed on the label or not.
PROGRAM Key
c
PAOG.
This key is used to set the various programs.
*
EMl-31055
-5-
This key is used to adjust the ZERO point.
NET Lamp Lights when tare is subtracted.
PREPACK Lamp
<+$
Lights when the SAVE key is depressed.
ERROR Lamp Lights when this machine is improperly operated or there is a function
error.
EM1-31055
-6-
EMl-31055
6. CONTROL LOCK
The control lock has seven marked positions.
There are two control keys which will operate these locks.
Manager Key
This key (MA) will access the
PROG/CMT, REG, M. DOWN.
and REWRAP positions.
SE Key
This key (SE) will access all
seven positions.
Each of the following positions on the control lock serves a different function.
PROG. CMT. ~ With the manager key in this position, it is possible to program data in the PLU
file, Store Address, Message, Printing Position, Date, Time, Initial Set, and Bar
Code Format, etc., may also be programmed.
REG.
These positions are the normal control lock positions which allow the issuance
of printed labels.
M.DOWN ~
In the Markdown position, it is possible to designate an item for discount pricing.
REWRAP I___
In the Rewrap position, it is possible to designate an item for rewrapping products.
X (Read) - This posi’tion is used to read all the accumulated sales totals stored in the unit.
These totals include individual item totals, group totals, hourly totals, and the entire
file totals.
2 (Reset) - This position is used to reset all item file totals.
-7-
EMl-31055
7. LEVEL ADJUSTMENT
Set the scale on a stable and level surface. Level
the scale by turning the adjustable legs so that
the air bubble is inside the center circle.
Level Gauge
Correct
Incorrect
When the air bubble moves toward the left side,
When the air bubble moves toward rear, turn the
turn the right adjustable legs clockwise,
front adjustable legs clockwise.
8. CLEANING THE PRINT HEAD
If the print head is dirty, clear printing will not be produced. It is recommended to clean the head with
the thermal head cleaner every day before starting operation using the following procedure:
Then push the head-up lever in the direction
indicated by the arrow.
diagram with the thermal head cleaner.
Then set the label cassette, and push down the
print head.
NOTE: Be careful not to damage the print head
when cleaning.
. Thermal Head Cleaner
-8-
EMl-31055
9. REMOVAL AND REPLACEMENT OF LABEL ROLL
(for On-demand printing mode)
1. Remove the printer cover and right side cover.
Then push the head-up lever in the direction
indicated by the allow.
2. Pull out the label cassette and remove the core’
of the label roll and the label backing paper.
NOTE: To remove the label backing paper,
loosen the paper by turning the paper
winding shaft counterclockwise and
remove the paper stopper.
roll on the label cassette.
the feed key to confirm that the label is
issued correctly.
EMl-31055
0 Label (for Batch printing mode) and Report Paper Threading
Roll stopper
Label or Report paper
10. NOTES BEFORE STARTING OPERATION
(1) Be sure to plug the power plug into an AC outlet.
(2) When the power switch is turned on! the scale goes through the test scanning sequence, such as
0000, 0000, 0000, then 11 1 1, 1 11 1, 1 1 1 1 l..... and zeros appear on the displays.
(3) While the scale is in the test sequence, do not put anything on the platter.
(4) Do not move the unit while it is in operation. Should it become necessary to move it at any time,
turn the power switch to the OFF position and be sure to readjust the level indicator after relocaitng
the scale.
(5) Should a power failure occur during operation, remove the commodity from the platter and insert
the power plug into an AC outlet again when power is restored.
(6) If the scale is used with an unrated power source, inaccurate scaling or other errors may occur.
(7) If the Zero Point has shifted during scaling, and no tare is displayed, adjust the Zero Point by
depressing the Zero key.
- 10 -
EMl-31055
11 OPERATION PROCEDURE
11-l. Weighed Article Registration
Control lock : REG. M.DOWN, or REWRAP
Mode SW(2) : WEIGH
Example A) In the case of an article for which PLU # 100 and a unit price of s3.00/lb are set in speed
key
q
.
Depress the speed key.
1 ENTER THE PLU #
I
io.oollP
t T-BONE STEAK
1
Place an article on.
I
(Ex. 5.00 lbs)
T-BONE STEAK
1
pzqr-G-lpi5q
AUTO
I 1
AUTO
MANUAL
MANUAL
The label is issued.
T
The label is issued.
4601-h BINKERS CIRCLE AT
(Sample label)
NOTE: Depressing a speed key which is not stored in PLU data beforehand causes the scale to enter
an error mode.
- 11 -
EMl-31055
Example B) In the case of an article for which a unit price of S2.5O/lb is set for PLU # 505.
t ENTER THE PLU #
I
I
inn
bplp
Enter the PLU #.
Depress:
Place an article on<
(Ex. 7.00 Ibs)
/5//
r
T
I
I
PLU
I
1 ENTER THE PLU #
I
pEiq~]Ip
1 LAMB SIRLOIN
I
t LAMB SIRLOIN I
A”‘~ :;,,,
MANUAL
L 1 J MAX: gl,,
The label is issued.
PRT/.
‘i
The label is issued.
(Sample label)
- 12 -
EMl-31055
11-2. By Count Registration
Control lock : REG, M.DOWN, or REWRAP
Mode SW(2) : BY COUNT
Example A) In the event that a price of $1.80/l 2 pcs is set for PLU #lOS.
ENTER THE PLU#
1
Enter the PLU#.
cl
PLU
kRUSTY ROLLS I
1 I
I-----mm
cl
PAT/*
Press to
suspend label
issue
temporarily.
resume label
Press to cancel
label issue.
cl
C
PLU data is
returned to
the PLU file.
cl
PLU
(Sample label)
- 13 -
EMl-31055
Example
6) In
the case of
purchasing
20
pcs
of
an article
for
$1
.OO of
price
for 4
PCS. (In
the event
that a price
of $1.00/4
pcs
is set for PLU # 1 13.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SPLIT PRICE
Enter the PLU#
LIFEI
I
cl
PLU
I
Enter the quantity of
purchase.
(Max.2 digits)
Elm
I
0
PRT/*
iENTER THE PLU#
1
I-----IIppxq
AUTO
7
The label is issued in
succession after peeling it.
I
Single label is issued.
DONUTS
PACKED ON
AUG 21
SELL BY
AUG 26
20 PECLS
$5.00
NflWT m PRICE,lb ;3
TEC BAKERY (TEL)888-I
1-l I
4401-A BAHKERS CIRCLE Al.
(Sample
label)
.
- 14-
EMl-31055
11-3. Fix Price Registration
Control lock : REG, M.DOWN, or REWRAP
Mode SW(2) : FIX
Example A) In the event that PLU #3036 and a unit price of $3.80/lb are set in speed key
q
.
1 ENTER THE PLU # I
Depress the speed key.
piqp-jpE6q
7
q
SMOKED SALMON CHUNKS
~o.oollpziq
,
Place an article on.
SMOKED SALMON CHUNKS
pziii-jn~~
MANUAL
The lab!!+
The label is issued.
SHOKED SALMON CHlltlKS 1
[4401-A BANKERS CIRCLE AT
I
(Sample label)
- 15-
EMl-31055
1 l-4. Preset Count Registration and Operation
Control lock : REG. M.DOWN, or REWRAP
Mode SW(2) : WEIGH, BY COUNT, or FIX
Example A) When Mode SW. (2) is at the ‘WEIGH” position
Depress:
1
Set the number of labels
(Max. 99 labels)
Depress:
1
Enter the
PLU #.
PLU data is saved.
cl
SAVE
Place the shrimps on.
(Ex. 1.50 Ibs)
1 ENTER THE PLU #
I
pzqp-j1[p
1 PRESET COUNT BALANCE 1
PRESET COUNT BALANCE
=a 0
ENTER THE PLU #
I
Io.ool~l~l
: SHRIMPS
[ 0.00 1 1
0.90 1 1 0.00 J
[ SHRIMPS
I
(o.00~~
-g
PREPACK -
SHRIMPS
I
~1.50110.9o)r~
7*
PREPACK
MANUAL:
Ll
:AUTO
SHRIMPS
Batch printing 4
The label is issued with the
backing paper attached.
.
0
A
PACKED 0N
AU6 26
printing
~~~~~~1~~~~~~~~~
SELL BY
AUG 28
1.50 0.90
$1.35
NETWT = PRICE;!>: 3
4401-A BANKERS
CIRCLE AT
,
(Sample label)
(continued on next page)
- 17 -
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55

TEC EMl-31055 User manual

Category
Kitchen scales
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI