I NSTALLATION I NSTRUCTIONS
P RO W ALL V ENTILATION H OODS
As you follow these instructions, you will
notice WARNING and CAUTION symbols.
This blocked information is important for the
safe and efficient installation of Wolf equip-
ment. There are two types of potential
hazards that may occur during installation.
Another footnote we would like to identify is
IMPORTANT NOTE: This highlights informa-
tion that is especially relevant to a problem-
free installation.
signals a situation where minor injury or
product damage may occur if you do not
follow instructions.
states a hazard that may cause serious
injury or death if precautions are not
followed.
WOLF
®
is a registered trademark of Wolf Appliance Company, Inc.
CONTACT
INFORMATION
Wolf Customer
Service:
800-332-9513
Website:
wolfappliance.com
3
INSTALLATION REQUIREMENTS
IMPORTANT NOTE:
This installation must be
completed by a qualified installer or Wolf
authorized service center technician.
Installer:
Please read the entire Installation
Instructions prior to installation. Save these
instructions for the local inspector’s refer-
ence, then leave them with the homeowner.
Homeowner:
Please read and keep these
instructions for future reference and be sure
to read the entire Use & Care Information
prior to use.
Any questions or problems about the
installation should be directed to your Wolf
dealer or Wolf Appliance Company, Inc. at
800-332-9513. You can also visit our website
at wolfappliance.com.
IMPORTANT NOTE:
This appliance must be
installed in accordance with National Electrical
Codes, as well as all state, municipal and local
codes. The correct voltage, frequency and
amperage must be supplied to the appliance
from a dedicated, grounded circuit which is
protected by a properly sized circuit breaker or
time delay fuse. The proper voltage, frequency,
and amperage ratings are listed on the product
rating plate.
Record the model and serial numbers before
installing the Pro wall ventilation hood. Both
numbers are listed on the rating plate, located
on the left wall of the hood shell.
Model Number
Serial Number
WOLF PRO WALL VENTILATION HOODS
Low-Profile Wall Hood
Low-Profile Wall Hood
(R) Rail Option
24" (610) Wall Hood
24" (610) Wall Hood
(R) Rail Option
27" (686) Wall Hood
27" (686) Wall Hood
(R) Rail Option
Dimensions in parentheses are in
millimeters unless otherwise specified.
LIST OF MATERIALS
The following is a list of materials shipped
with the Wolf Pro wall ventilation hood.
Stainless steel wall hood
Transition with backdraft damper (attached
inside hoodneeds to be removed)
Decorative stainless steel rail and installa-
tion components(R) model hoods only
Control knobs—two for low-profile and 24"
(610) deep hoods, three for 27" (686) deep
hoods
Filters and grease cups (installed in hood)
(10) #10 x 2" (51) self-tapping hex head
screws
(10) 10-24 washer nuts
Installation package (taped to filters)
Installation Instructions
Use & Care Information and product
registration card
Wolf logo nameplate
4
WOLF PRO WALL VENTILATION HOODS
IMPORTANT NOTE:
Wolf recommends that
the Pro wall ventilation hood be installed
30" (762) to 36" (914) above the countertop.
Rail option (R) wall hoods come with a classic
stainless steel decorative rail and stand-offs.
Optional platinum or brass rails are available
to match Wolf dual fuel range bezels. Contact
your Wolf dealer for details.
ELECTRICAL REQUIREMENTS
Wolf Pro wall ventilation hoods require a
separate, grounded 110/120 V AC, 60 Hz power
supply. The service should have its own 15
amp circuit breaker. Locate the electrical
supply within the shaded area shown in the
Installation Specifications illustration for your
specific wall hood on page 6.
You must follow all National Electrical Code
regulations. In addition, be aware of local
codes and ordinances when installing your
service.
DUCT COVER
If you are installing a Wolf duct cover with the
wall hood, refer to instructions on page 21
before installing the hood.
RECIRCULATING KIT
If you are installing the accessory recirculating
kit, refer to the instructions included with the
kit before installing the hood.
ACCESSORIES
Optional acces-
sories are available
through your
Wolf dealer. To
obtain local dealer
information, visit
the Locator section
of our website,
wolfappliance.com.
INSTALLATION CONSIDERATIONS
Wolf Pro wall ventilation hoods are
recommended for use with all Wolf cooking
appliances.
IMPORTANT NOTE:
For optimal performance,
a Pro 27" (686) deep wall hood is recom-
mended for use with ranges and rangetops
that contain a charbroiler or griddle.
Proper installation is the responsibility
of the installer. Product failure due to
improper installation is not covered
under the Wolf Warranty. Refer to the Wolf
Pro Ventilation Hoods Use & Care
Information for warranty details, or visit
the Contact/ Help section of our website,
wolfappliance.com.
Make sure you have the tools and materials
necessary for proper installation.
Warranty service must be performed by a
Wolf authorized service center. Wolf is not
responsible for service required to correct a
faulty installation.
IMPORTANT NOTE:
Wolf Pro ventilation
hoods are shipped without the blower
assembly. Wolf internal, in-line and remote
blower assemblies are available, refer to page
20. Use only a Wolf blower with the Pro wall
ventilation hood.
5
Dimensions in parentheses are in
millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
10" (254)
OVERALL
HEIGHT
OVERALL WIDTH
4" (102)
22" (559)
OVERALL DEPTH
12"
(305)
2"
(51)
3
/4" (19)
DIAMETER
OF RAIL
OVERALL WIDTH
4" (102)
24" (610)
OVERALL DEPTH
12"
(305)
18" (457)
OVERALL
HEIGHT
2"
(51)
3
/4" (19)
DIAMETER
OF RAIL
OVERALL WIDTH
27" (686)
OVERALL DEPTH
12"
(305)
18" (457)
OVERALL
HEIGHT
2"
(51)
4" (102)
3
/4" (19)
DIAMETER
OF RAIL
OVERALL DIMENSIONS
LOW-PROFILE WALL HOODS
Overall Widths 30" (762), 36" (914),
42" (1067) and 48" (1219)
Overall Height
10" (254)
Overall Depth (
excluding
rail) 22" (559)
Shipping Weight (shell only) 39–55 lbs
(18–25 kg)
Dimensions may vary to ±
1
/
8
" (3).
24" (610) DEEP WALL HOODS
Overall Widths 30" (762), 36" (914),
42" (1067), 48" (1219), 54" (1372),
60" (1524) and 66" (1676)
Overall Height
18" (457)
Overall Depth (
excluding
rail) 24" (610)
Shipping Weight (shell only) 67–126 lbs
(30–57 kg)
Dimensions may vary to ±
1
/
8
" (3).
27" (686) DEEP WALL HOODS
Overall Widths 30" (762), 36" (914),
42" (1067), 48" (1219), 54" (1372),
60" (1524) and 66" (1676)
Overall Height
18" (457)
Overall Depth (
excluding
rail) 27" (686)
Shipping Weight (shell only) 69–128 lbs
(31–58 kg)
Dimensions may vary to ±
1
/
8
" (3).
Low Profile Wall Hood
shown with (R) rail option
24" (610) Deep Wall Hood
shown with (R) rail option
27" (686) Deep Wall Hood
shown with (R) rail option
6
WOLF PRO WALL VENTILATION HOODS
30" TO 36"
(762–914)
TO COUNTERTOP
30" TO 36"
(762–914)
TO COUNTERTOP
10" (254)
18" (457)
HEIGHT
OF HOOD
22" (559)
24" (610)
DEPTH OF HOOD
WIDTH OF HOOD
NOTE: Low-profile and 24" (610) deep wall hoods have a vertical or horizontal discharge; discharge direction varies with blower model.
E
6"
(152)
5"
(127)
LOCATION OF ELECTRICAL
30" TO 36"
(762–914)
TO COUNTERTOP
30" TO 36"
(762–914)
TO COUNTERTOP
18" (457)
HEIGHT
OF HOOD
27" (686)
DEPTH OF HOOD
WIDTH OF HOOD
E
6"
(152)
5"
(127)
LOCATION OF ELECTRICAL
NOTE: 27" (686) deep wall hoods are vertical discharge only.
INSTALLATION SPECIFICATIONS
Low-Profile and
24" (610) Deep
Wall Hoods
27" (686) Deep
Wall Hoods
7
Dimensions in parentheses are in
millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
INSTALLATION SPECIFICATIONS
The following chart provides dimensions
specific to each wall hood model. These
dimensions are critical for proper installation.
Also refer to the illustration below.
Low-Profile Wall Hoods
Model (A) (B) (C) (D)
W302210I 30" (762) 7
1
/2" (191) 15" (381) 4
11
/16" (119)
W362210I 36" (914) 7
1
/2" (191) 18" (457) 4
11
/16" (119)
W362210 36" (914) 7
1
/2" (191) 18" (457) 4
11
/16" (119)
W422210 42" (1067) 7
1
/2" (191) 21" (533) 4
11
/16" (119)
W482210 48" (1219) 7
1
/2" (191) 24" (610) 4
11
/16" (119)
24" (610) Deep Wall Hoods
Model (A) (B) (C) (D)
W302418 30" (762) 9
1
/2" (241) 15" (381) 5
13
/16" (148)
W362418 36" (914) 9
1
/2" (241) 18" (457) 5
13
/16" (148)
W422418 42" (1067) 9
1
/2" (241) 21" (533) 5
13
/16" (148)
W482418 48" (1219) 9
1
/2" (241) 24" (610) 5
13
/16" (148)
W542418 54" (1372) 9
1
/2" (241) 27" (686) 5
13
/16" (148)
W602418 60" (1524) 9
1
/2" (241) 30" (762) 5
13
/16" (148)
W662418 66" (1676) 9
1
/2" (241) 33" (838) 5
13
/16" (148)
27" (686) Deep Wall Hoods
Model (A) (B) (C) (D)
W302718 30" (762) 9
1
/2" (241) 15" (381) 5
13
/16" (148)
W362718 36" (914) 9
1
/2" (241) 18" (457) 5
13
/16" (148)
W422718 42" (1067) 9
1
/2" (241) 21" (533) 5
13
/16" (148)
W482718 48" (1219) 9
1
/2" (241) 24" (610) 5
13
/16" (148)
W542718 54" (1372) 9
1
/2" (241) 27" (686) 5
13
/16" (148)
W602718 60" (1524) 9
1
/2" (241) 30" (762) 5
13
/16" (148)
W662718 66" (1676) 9
1
/2" (241) 33" (838) 5
13
/16" (148)
Letters correspond to those in the illustration.
C
TO CENTER
OF TRANSITION
D
A
WIDTH
OF HOOD
TO CENTER
OF TRANSITION
B
HEIGHT OF
TRANSITION
8
LOW-PROFILE AND 24" (610) HOODS
STEP 1: INSTALL DUCTWORK
IMPORTANT NOTE:
Wolf recommends that
the Pro wall ventilation hood be installed
30" (762) to 36" (914) above the countertop.
IMPORTANT NOTE:
Consult a qualified HVAC
Engineer for specific ducting applications.
IMPORTANT NOTE:
All Wolf Pro wall hoods
must exhaust to the outdoors except when
used with the accessory recirculating kit.
Always use metal ducting. Do not use flex
ducting.
Decide where the ductwork will run between
the hood and the outside. A straight, short
duct run will allow the hood to perform more
efficiently. Limit the number of elbows and
transitions to as few as possible. Long duct
runs, elbows and transitions will reduce the
performance of the hood. Wolf recommends
the maximum linear duct run be no greater
than 50' (15 m). The low-profile and 24" (610)
deep wall hoods have an adjustable discharge
that can run vertically or horizontally.
Horizontal discharge is only applicable on
low-profile wall hoods (excluding W302210I
and W362210I) used with a remote blower.
In-line blowers and WBLOWER-60INT are not
for use in horizontal discharge applications
with a low-profile wall hood.
Horizontal discharge is applicable on 24" (610)
deep wall hoods used with WBLOWER-60INT,
WBLOWER-120INT or any Wolf remote blower.
In-line blowers and WBLOWER-90INT are not
for use in horizontal discharge applications.
IMPORTANT NOTE:
There is a possibility of
noise issues if there is a short duct run
coupled with a remote blower.
To reduce the risk of fire, use only metal
ductwork.
WOLF PRO WALL VENTILATION HOODS
DUCTWORK INSTALLATION
THROUGH ROOF
22" (559)
DEPTH OF HOOD
8" ROUND DUCT
SOFFIT OR CABINET
OR DUCT COVER
REMOTE BLOWER
*HORIZONTAL DISCHARGE APPLICABLE ON LOW-PROFILE WALL HOODS
(EXCLUDING W302210I AND W362210I) USING A REMOTE BLOWER. LOW-PROFILE WALL
HOODS WITH AN INTERNAL OR IN-LINE BLOWER MUST USE VERTICAL DISCHARGE.
DUCTWORK INSTALLATION
THROUGH WALL
DISCHARGE COLLAR
HORIZONTAL
DISCHARGE*
VERTICAL DISCHARGE
TRANSITION
17
3
/4"W x 4
1
/4"D TO 8" ROUND
9
3
/8"H (INCLUDING FLANGES)
30" TO 36"
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
10" (254)
HEIGHT OF HOOD
WALL HOOD
ROOF CAP OR REMOTE BLOWER –
TRANSITION FROM 8" (203) TO 10" (254) DUCT
REQUIRED FOR REMOTE BLOWER
Ducting options for low-profile wall hoods
LOW-PROFILE AND 24" (610) HOODS
Always install a roof or wall cap if you are not
installing a remote blower. Connect 8" (203)
round metal ductwork for low-profile hoods or
10" (254) round metal ductwork for 24" (610)
deep hoods to the cap and work back towards
the hood. Use duct sealing tape on joints
between ductwork sections.
IMPORTANT NOTE:
Do not use ducting
smaller than 8" (203).
Wolf Pro wall hoods come standard with a
backdraft damper included in the transition
assembly. Local codes may require the use of
an additional backdraft damper. Contact your
local HVAC professional for specific require-
ments. In cold weather installations, a back-
draft damper is necessary to minimize the
backflow of cold air into the room.
Local building codes may require the use of
make-up air. Consult your local HVAC profes-
sional for specific requirements in your area.
9
Dimensions in parentheses are in
millimeters unless otherwise specified.
DUCTWORK INSTALLATION
THROUGH ROOF
24" (610)
DEPTH OF HOOD
ROOF CAP OR REMOTE BLOWER
10" ROUND DUCT
SOFFIT OR CABINET
OR DUCT COVER
WALL CAP
OR REMOTE BLOWER
*HORIZONTAL DISCHARGE IS APPLICABLE ON 24" (610) DEEP WALL HOODS USED WITH
WBLOWER-60INT, WBLOWER-120INT OR ANY WOLF REMOTE BLOWER. WBLOWER-90INT
AND IN-LINE BLOWERS ARE NOT FOR USE IN HORIZONTAL DISCHARGE APPLICATIONS.
DUCTWORK INSTALLATION
THROUGH WALL
DISCHARGE COLLAR
HORIZONTAL
DISCHARGE*
VERTICAL DISCHARGE
TRANSITION
22
1
/4"W x 9"D TO 10" ROUND
10"H (INCLUDING FLANGES)
30" TO 36"
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
18" (457)
HEIGHT OF HOOD
WALL HOOD
To reduce the risk of fire and electric
shock, install this ventilation hood only
with a blower manufactured by Wolf.
Blower model numbers are listed on
page 20.
INSTALLATION INSTRUCTIONS
Ducting options for 24" (610) deep wall hoods
10
WOLF PRO WALL VENTILATION HOODS
ACCESSORIES
Optional acces-
sories are available
through your
Wolf dealer. To
obtain local dealer
information, visit
the Locator section
of our website,
wolfappliance.com.
LOW-PROFILE AND 24" (610) HOODS
STEP 2: WALL PREPARATION
Construct the wood wall framing flush with
the wall studs and centered in the location
that the hood will be mounted. Use the
rough-in plate shipped with hood to deter-
mine the location of the framing.
After the wall surface is finished, secure the
hood assembly to the wall.
Refer to the illustrations below for the location
of mounting holes for the low-profile and 24"
(610) deep wall hoods.
IMPORTANT NOTE:
Wolf recommends
installing the internal blower to the rough-in
plate prior to mounting the hood.
If you are installing WBLOWER-60INT,
WBLOWER-90INT or WBLOWER-120INT,
refer to the internal blower information on
page 17 and follow installation instructions
provided with the blower.
The hood assembly is shipped with the
rough-in plate/transition attached. The
transition is shipped upside down in the top
of the hood. It must be removed and rein-
stalled in the proper position.
Remove the filters by pushing each filter up
at the angle it is placed in, and rotate down.
Remove the center filter first. Then take out
the grease cups placed on the bottom edge
of the hood coinciding with the bottom
edge of the filters. Gloves should be worn
to provide the proper grip when removing
filters.
Detach the rough-in plate/transition
assembly from the hood by removing the
screws from the top and back of the
assembly. Refer to the illustration below.
Framing must be tied together and to
ceiling joists to provide enough structural
strength to support the weight of the
hood and internal blower, if applicable.
If wall framing is not available, wall
anchors must be used.
*
*
*
*
*
*
*
*
5" (127)
3
1
/2
"
(89)
*Dimension is 1
1
/2
" (38)
7
1
/2
" (191)
17
3
/4
" (451)
8" (203)
5"
(127)
5" (127)
5"
(127)
3
1
/4
" (83)
11
/16
" (17)
16
5
/8
"
(422)
*
*
*
*
*
*
*
*
*Dimension is 2" (51)
9
1
/2
" (241)
21
1
/4
" (540)
4
1
/2
" (114)
10" (254)
8
1
/2
" (216)
4
1
/2
"
(114)
4
1
/2
"
(114)
4
1
/2
" (114)
13
/16
" (21)
20" (508)
8" (203)
Mounting holes for low-profile hoods Mounting holes for 24" (610) hoods
Rough-In
Plate
Shipping
Screws
Transition
Rough-in plate/transition assembly
STEP 3: HOOD PREPARATION
IMPORTANT NOTE:
If a duct cover is to be
used, follow instructions on page 21 before
installing the wall hood. If you are installing a
recirculating kit, refer to instructions included
with the kit before installing the wall hood.
11
Dimensions in parentheses are in
millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
17 " (432)
8" (203)
Wall Cut-Out Area
Hood Centerline
4
1
/2
" (114) 4
11
/16
" (119)
4" (102)
Transition
Centerline
Wall cut-out for low-profile hoods – horizontal
discharge
21" (533)
Wall Cut-Out Area
Hood Centerline
10
1
/4
"
(260)
5
13
/16
"
(148)
Transition
Centerline
Wall cut-out for 24" (610) deep hoods –
horizontal discharge
LOW-PROFILE AND 24" (610) HOODS
Separate the transition from the rough-in
plate by removing the four shipping screws.
Do not discard the screws
; they will be
needed to reinstall the transition to the
rough-in plate.
Determine the direction of discharge for
your installation and rotate the back panel
accordingly. The wall hood back panel has
been designed to accommodate a vertical
or horizontal discharge.
Horizontal discharge is only applicable on
low-profile wall hoods (excluding W302210I
and W362210I) used with a remote blower.
Horizontal discharge is applicable on 24"
(610) deep wall hoods used with WBLOWER-
60INT, WBLOWER-120INT or any Wolf
remote blower.
In-line blowers and WBLOWER-90INT are not
for use in horizontal discharge applications.
Use the rough-in plate assembly to deter-
mine the location of wall studs. Position the
rough-in plate in the desired location and
mark the predrilled mounting holes on the
wall.
For horizontal discharge, the electrical box
will need to be moved so that it is in the
upper right-hand corner of the rough-in
plate when attached to the wall.
Horizontal discharge requires a wall cut-out.
Refer to the illustrations below. The location
of the cut-out is determined by the installa-
tion height of the hood.
If you are installing an in-line or remote
blower, drill a
7
/8" (22) hole through the
wood framing for the conduit. Refer to the
in-line and remote blower information on
pages 18–19 and follow installation instruc-
tions provided with the blower.
IMPORTANT NOTE:
Do not run wiring for the
remote blower through the ductwork.
STEP 4: REATTACH ROUGH-IN PLATE
Reattach the transition to the rough-in plate
using the four shipping screws removed
previously.
Position the studs on the rough-in plate into
the slots on the hood. Use the hex head
nuts (included with the hood) to secure the
hood assembly to the rough-in plate.
Reinstall the shipping screws removed
previously from the top and back of the
rough-in plate.
IMPORTANT NOTE:
If additional support is
required, drill supplementary mounting holes
in the rough-in plate and use these holes to
attach the hood assembly to the wall framing.
12
WOLF PRO WALL VENTILATION HOODS
Rough-In Plate
Mounting Holes
Soffit
Hood installation
LOW-PROFILE AND 24" (610) HOODS
STEP 5: INSTALL THE HOOD
IMPORTANT NOTE:
If a backsplash is to be
used, it should be installed before the wall
hood is mounted.
Align the hood assembly with the marked
location.
Install the #10 x 2" (59) screws (included
with the hood) through the mounting holes
on the rough-in plate. Verify that the screws
engage the wall studs or framing. If not,
wall anchors must be used.
Attach the transition to existing ductwork
with sheet metal screws and duct sealing
tape.
Due to the weight of the hood, be
sure to have adequate manpower for
installation.
COMPLETE THE INSTALLATION
To complete the installation for the low-profile
and 24" (610) deep wall hoods, follow Step 6:
Install Wiring and refer to information on
pages 17–19 for internal, in-line and remote
blowers.
Follow instructions to install the filters and
grease cups on page 21. If you will be attach-
ing the Wolf logo nameplate, follow the steps
on page 22.
13
Dimensions in parentheses are in
millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
30" TO 36"
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
18" (457)
HEIGHT OF HOOD
WALL HOOD
DUCTWORK INSTALLATION
THROUGH ROOF
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
27" (686)
DEPTH OF HOOD
10" ROUND DUCT
SOFFIT OR CABINET
OR DUCT COVER
VERTICAL DISCHARGE ONLY FOR 27" (686) DEEP WALL HOODS.
TRANSITION
22
1
/4"W x 9"D TO 10" ROUND
10"H
(INCLUDING FLANGES)
ROOF CAP OR REMOTE BLOWER
VERTICAL DISCHARGE
27" (686) DEEP WALL HOODS
STEP 1: INSTALL DUCTWORK
IMPORTANT NOTE:
Wolf recommends that
the Pro wall ventilation hood be installed
30" (762) to 36" (914) above the countertop.
IMPORTANT NOTE:
Consult a qualified HVAC
Engineer for specific ducting applications.
IMPORTANT NOTE:
All Wolf Pro 27" (686)
deep wall hoods must exhaust to the outdoors.
Always use metal ducting. Do not use flex
ducting.
Decide where the ductwork will run between
the hood and the outside. A straight, short
duct run will allow the hood to perform more
efficiently. Limit the number of elbows and
transitions to as few as possible. Long duct
runs, elbows and transitions will reduce the
performance of the hood. Wolf recommends
the maximum linear duct run be no greater
than 50' (15 m). The 27" (686) deep wall hood
is vertical discharge only.
Always install a roof or wall cap if you are not
installing a remote blower. Connect 10" (254)
round metal ductwork to the cap and work
back towards the hood. Use duct sealing tape
on joints between ductwork sections.
IMPORTANT NOTE:
Do not use ducting
smaller than 10" (254) round.
Pro wall hoods come standard with a backdraft
damper included in the transition assembly. In
cold weather installations a backdraft damper
is necessary to minimize the backflow of cold
air into the room.
Local building codes may require the use of
make-up air. Consult your local HVAC profes-
sional for specific requirements in your area.
To reduce the risk of fire, use only metal
ductwork.
Ducting options for 27" (686) deep wall hoods
To reduce the risk of fire and electric
shock, install this ventilation hood only
with a blower manufactured by Wolf.
Blower model numbers are listed on
page 20.
The hood assembly is shipped with the
rough-in plate/transition attached. The
transition is shipped upside down in the top
of the hood. It must be removed and rein-
stalled in the proper position.
Remove the filters by pushing each filter up
at the angle it is placed in, and rotate down.
Remove the center filter first. Then take out
the grease cups placed on the bottom edge
of the hood coinciding with the bottom edge
of the filters. Gloves should be worn to
provide the proper grip when removing
filters.
Detach the rough-in plate/transition
assembly from the hood by removing the
screws on the top and back of the assembly.
Separate the transition from the rough-in
plate by removing the four shipping screws.
Do not
discard the screws, they will be
needed to reinstall the transition to the
rough-in plate. Refer to the illustration
below.
Reattach the transition to the rough-in plate
using the four shipping screws removed
previously.
Attach the transition to existing ductwork
with sheet metal screws and duct sealing
tape.
14
WOLF PRO WALL VENTILATION HOODS
27" (686) DEEP WALL HOODS
STEP 2: WALL PREPARATION
Construct the wood wall framing flush with
the wall studs and centered in the location
that the hood will be mounted. Use the
rough-in plate shipped with hood to deter-
mine the location of the framing.
After the wall surface is finished, secure the
rough-in plate to the wall surface.
Framing must be tied together and to
ceiling joists to provide enough structural
strength to support the weight of the
hood and internal blower, if applicable.
If wall framing is not available, wall
anchors must be used.
*
*
*
*
*
*
*
*
*Dimension is 2" (51)
9
1
/2
" (241)
21
1
/4
" (540)
4
1
/2
" (114)
10" (254)
8
1
/2
" (216)
4
1
/2
"
(114)
4
1
/2
"
(114)
4
1
/2
" (114)
13
/16
" (21)
20" (508)
8" (203)
Mounting holes for 27" (686) hoods
Rough-In
Plate
Shipping
Screws
Transition
Rough-in plate installation
ACCESSORIES
Optional acces-
sories are available
through your
Wolf dealer. To
obtain local dealer
information, visit
the Locator section
of our website,
wolfappliance.com.
STEP 3: HOOD PREPARATION
IMPORTANT NOTE:
If a duct cover is to be
used, follow instructions on page 21 before
installing the wall hood.
Refer to the illustration below for the location
of mounting holes for the 27" (686) wall hood.
15
Dimensions in parentheses are in
millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
Rough-In
Plate
Soffit
Mounting
Holes
Hood installation
27" (686) DEEP WALL HOODS
If you are installing WBLOWER-90INT or
WBLOWER-120INT, refer to the internal
blower information on page 17 and follow
installation instructions provided with the
blower.
If you are installing an in-line or remote
blower, drill a
7
/8" (22) hole through the
wood framing for the conduit. Refer to the
in-line and remote blower information on
pages 18–19 and follow installation instruc-
tions provided with the blower.
IMPORTANT NOTE:
Do not run wiring for the
remote blower through the ductwork.
STEP 4: INSTALL ROUGH-IN PLATE
Use the rough-in plate assembly to deter-
mine the location of wall framing.
Install the #10 x 1" (25) screws (included
with the hood) through the rough-in plate
into the wall framing.
IMPORTANT NOTE:
If additional support is
required for the hood, drill supplementary
mounting holes in the rough-in plate and use
these holes to attach the hood assembly to the
wall framing.
STEP 5: INSTALL THE HOOD
IMPORTANT NOTE:
If a backsplash is to be
used, it should be installed before the wall
hood is mounted.
Align both ends of the hood assembly with
the ends of the rough-in plate. Refer to the
illustration below.
Insert the back edges of the hood assembly
into the rough-in plate and push the hood
assembly toward the wall.
Place the studs on the rough-in plate into
the slots on the hood. Use the hex head
nuts (included with the hood) to secure the
hood assembly to the rough-in plate.
Install the remaining #10 x 2" (51) screws
(included with the hood) in the lower
section of the hood. Verify that the screws
engage the wall studs or framing. If not,
wall anchors must be used.
Due to the weight of the hood, be
sure to have adequate manpower for
installation.
Remove the electrical box cover from the
rough-in plate. Connect black wire to power
supply black wire, white wire to power
supply white wire and green wire to green
wire or bare wire.
Place all wiring connections inside the elec-
trical box and reinstall on the rough-in plate
in the upper right-hand corner. Make sure
that the wires are secure and that no wires
are pinched between the cover and box.
16
WOLF PRO WALL VENTILATION HOODS
PRO WALL VENTILATION HOODS
STEP 6: INSTALL WIRING
This ventilation hood must be properly
grounded. This unit should be installed by
a qualified electrician in accordance with
all applicable national and local electrical
codes.
Before servicing or cleaning unit, switch
power off at service panel and lock the
service disconnecting means to prevent
power from being switched on acciden-
tally. When the service disconnecting
means cannot be locked, securely fasten a
prominent warning device, such as a tag,
to the service panel.
Do not remove the control knob bezel to
access hood wiring; this will damage the
bezel assembly.
Run a 120 V AC, 15 amp circuit power cable
from the service panel to the electrical box
in the rough-in plate.
Remove the knockout and install the
conduit connector on the rough-in plate
hole. Refer to the illustrations below for the
wiring location of your specific wall hood.
Insert the conduit through the hole on top
of the rough-in plate to the electrical box.
2
1
/2
" (64)
2
1
/2
" (64)
2" (51)
2
1
/2
" (64)
2
1
/2
" (64)
2" (51)
2
1
/2
" (64)
2
1
/2
" (64)
2" (51)
27" (686) deep hoods wiring locationLow-profile hoods wiring location 24" (610) deep hoods wiring location
IMPORTANT
NOTE
You must follow
all National
Electrical Code
regulations. In
addition, be aware
of local codes and
ordinances when
installing your
service.
17
Dimensions in parentheses are in
millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
INTERNAL BLOWERS
IMPORTANT NOTE:
Refer to the specific
installation instructions provided with each
internal blower for additional mounting and
wiring instructions.
IMPORTANT NOTE:
Use wire connectors or
wire nuts approved by UL or C/UL.
IMPORTANT NOTE:
Wolf recommends
installing the internal blower to the rough-in
plate assembly prior to installing the hood to
the wall framing.
INTERNAL BLOWER INSTALLATION
Assemble the blower housing to the blower
rough-in plate. Follow installation instruc-
tions included with the blower assembly for
proper installation.
Once the blower is mounted to the blower
rough-in plate, attach the blower assembly
to the hood rough-in plate. To attach, slide
the blower rough-in plate over the weld
studs and secure with eight nuts (included
with the blower). Refer to the illustration
below.
Verify that the blower discharge aligns with
the discharge cut-out in the back panel of
the hood.
Install the hood rough-in plate with blower
assembly to the wall. Secure the power
cord(s) without damaging or pinching while
installing the hood shell.
For low-profile and 24" (610) wall hoods,
follow hood installation instructions on
page 8. For 27" (686) wall hoods, follow
hood installation instructions on page 13.
Once the hood installation is complete, plug
the blower power cord(s) into receptacle(s)
located near the center of the hood shell.
Use the clips on the interior of the hood to
keep excess power cord away from moving
parts.
IMPORTANT NOTE:
Before turning the power
on to the ventilation hood, make sure the
blower is off.
Hood
Rough-In
Plate
Blower
Rough-In
Plate
Blower
Housing
Internal blower installation
18
WOLF PRO WALL VENTILATION HOODS
ACCESSORIES
Optional acces-
sories are available
through your
Wolf dealer. To
obtain local dealer
information, visit
the Locator section
of our website,
wolfappliance.com.
11
3
/4"
(298)
21
1
/2"
(546)
24
3
/8"
(619)
18
1
/2"
(470)
12
1
/4"
(311)
4
1
/2"
(114)
IN-LINE AND REMOTE BLOWERS
BLOWER INSTALLATION
IMPORTANT NOTE:
Refer to the specific
installation instructions provided with each
blower for additional mounting instructions.
Locate the blower so that the length of the
duct run and number of elbows and transitions
are kept to a minimum. Wolf recommends the
maximum linear duct run be no greater than
50' (15 m).
If possible, remote blowers should be located
between wall studs or roof rafters. Avoid
pipes, wires or other ductwork that may be
running through the wall.
Be sure that there is enough space for any
transitions that may be needed between the
blower and the connecting ductwork. For best
performance, locate transitions nearest the
blower.
Refer to the illustrations below and on the
following page for overall dimensions of Wolf
in-line and remote blowers. Also refer to the
specific installation instructions provided with
each remote blower to verify cut-out dimen-
sions.
Dimensions for BLOWER-60IL
18"
(457)
22"
(559)
24
7
/8
"
(632)
12"
(305)
18"
(457)
8"
(203)
Dimensions for BLOWER-110IL
19
Dimensions in parentheses are in
millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
IN-LINE AND REMOTE BLOWERS
BLOWER WIRING
IMPORTANT NOTE:
Refer to the specific
installation instructions provided with each
blower for additional wiring instructions.
Follow wiring instructions at the blower as
outlined in the specific installation instruc-
tions provided with each blower. Black (L1)
to black, white (neutral) to white, or white
to blue, or white to brown (depending on
model) and green to grounding screw. Run
blower cable (ROMEX) to the hood.
Insert 6" (152) of ROMEX cable through the
knockout opening and into the electrical
box on the rough-in plate of the hood.
Secure the cable to the electrical box with
an appropriate connector.
Locate the cord assembly provided with the
blower. The cord assembly has two leads,
black (L1) and white (neutral). Connect
these leads to the leads from the blower,
black to black and white to white.
Connect
all
green and bare wires together
to the ground screw in the electrical box.
Plug the cord assembly into the receptacle
located near the center of the hood shell.
Use the clips on the interior of the hood to
keep excess power cord away from moving
parts.
Reinstall the electrical box cover and
screws in the upper right-hand corner of the
hood. Make sure that all wires are secure
and that no wires are pinched between the
cover and box.
IMPORTANT NOTE:
Before turning the power
on to the ventilation hood, make sure the
blower is off.
When making electrical connections,
make sure the electrical power is turned
off at the power source or circuit breaker
before proceeding.
24
1
/2
"
(622)
15
1
/2
"
(394)
28
1
/4
"
(718)
20
3
/4
"
(527)
24
3
/4
"
(629)
14"
(356)
4
3
/4
"
(121)
10" (254)
Diameter
14
3
/4
"
(375)
29
1
/2
"
(749)
29
1
/2
"
(749)
18" (457)
22"
(559)
10
1
/8
"
(257)
7
1
/4
"
(184)
10"
(254)
10" (254)
Diameter
Dimensions for BLOWER-90REM
14
3
/4
"
(375)
29
1
/2
"
(749)
29
1
/2
"
(749)
21" (533)
25"
(635)
10
3
/8
"
(264)
7
1
/4
"
(184)
10"
(254)
10" (254)
Diameter
Dimensions for BLOWER-150REMDimensions for BLOWER-120REM
20
WOLF PRO WALL VENTILATION HOODS
REMOTE BLOWERS
BLOWER-60REM (801640) –
600 CFM
remote blower for low-profile wall hoods
(except Models W302210I and W362210I),
and Models W302418 and W302718.
BLOWER-90REM (801641) –
900 CFM
remote blower for low-profile wall hoods
(except Models W302210I and W362210I),
and 24" (610) and 27" (686) deep wall
hoods; 30" (762), 36" (914), 42" (1067), 48"
(1219) and 54" (1372) wide models.
BLOWER-120REM (801642) –
1200 CFM
remote blower for all 24" (610) and 27" (686)
deep wall hoods.
BLOWER-150REM (804701) –
1500 CFM
remote blower for all 24" (610) and 27" (686)
deep wall hoods.
RECIRCULATING KITS
RECIRC30 (808223) –
Must be used with
WBLOWER-60INT (807614). Blower included
with wall hood Model W302210I. Kit can be
installed on Models W302210I and
W302418.
RECIRC36 (808224) –
Must be used with
WBLOWER-60INT (807614). Blower included
with wall hood Model W362210I. Kit can be
installed on Models W362210I, W362210
and W362418.
BLOWER ASSEMBLIES
Wolf Pro wall ventilation hoods are shipped
without the blower assembly. Wolf internal,
in-line and remote blower assemblies are
available as sales accessories through your
Wolf dealer.
IMPORTANT NOTE:
Blower options vary with
the cooking surface. Use only a Wolf blower
with the Pro wall ventilation hood.
Refer to the Wolf Design Guide for Pro
ventilation recommendations. You can also
visit our website at wolfappliance.com.
INTERNAL BLOWERS
(
805347) –
600 CFM internal blower
included with Models W302210I and
W362210I.
WBLOWER-60INT (807614) –
600 CFM
internal blower for low-profile wall hoods
(except Models W302210I and W362210I),
and 24" (610) and 27" (686) deep wall
hoods; 30" (762), 36" (914) and 42" (1067)
wide models.
WBLOWER-90INT (805086) –
900 CFM
internal blower for 24" (610) and 27" (686)
deep wall hoods; 30" (762), 36" (914) and
42" (1067) wide models.
WBLOWER-120INT (804702) –
1200 CFM
internal blower for 24" (610) and 27" (686)
deep wall hoods; 48" (1219), 54" (1372), 60"
(1524) and 66" (1676) wide models.
IN-LINE BLOWERS
BLOWER-60IL (808189) –
600 CFM
in-line blower for low-profile wall hoods
(except Models W302210I and W362210I),
and 24" (610) and 27" (686) deep wall
hoods, Models W302418 and W302718.
BLOWER-110IL (808190) –
1100 CFM
in-line blower for all 24" (610) and 27" (686)
deep wall hoods.
/