Jenn-Air JGD8130ADS20 Installation guide

Category
Barbecues & grills
Type
Installation guide
CONVERTIBLEGAS GRILL
COOKTOPSERIES
JGD8130 & JGD8345
=JENN-AIR ,1
403WESTFOURTHSTREET,NORTH NEWTON,IA 5020
DIMENSIONSSHOWN IN BOTH INCHES AND CENTIMETERS
*Blower may be rotated for horizontal or vertical direction by loosening nuts around blower inlet. Accessible inside ventilation
chamber.
NOTICE TO INSTALLER: Leave these instructions with the appliance.
NOTICE TO CONSUMER: Retain these instructions for future reference.
TIEDOWNBOLT
ON EACHEND
BLOWERCANBE GREASE
SWIVELED90° CONTAINER
,--I"1 29" + 1
, 73,66 cm
DUCTINGINSTALLA-
TION INSTRUCTIONS).
T 3 1/2"
8.8 cm
t
13 13/16"
35.1 cm
2 7/8"
7.3 crn
.Am_
REGULATOR
21" + 1/16"
53,34 cm
7 9/16"
19,21 cm
APPLIANCEPRESSURE
REGULATOR
TIE DOWNBOLT
ON EACHEND
GREASE
BLOWERCANBE CONTAINER
SWIVELED90°
43 1/4" + 1/ 21" + 1/16"
_"_1 109.86 cm , 53.34cm
79/16"
1 7/8"
Min.
'l 15/16" 4,76 cm
Min.
Clearance
2.38 cm
3RIATE _"4f _ ._
(SEE---'
SELECTAPPROPRIATE
DUCTCUT OUT
DUCTINGINSTALLA-
GREASE TION INSTRUCTIONS).
CONTAINER GREASE
r II" \_ "1_ ;l_ _ _ CONTA,NER
[ .
I II I[[F_]_'_'_'_APPLEANCE
PRESSURE 13
FEGULATOR 35 .
3_.9om _o.ooo 7237,8L
INSTRUCTIONSTO INSTALLER
Dimension "A" - Provide 2" min. (5.08 cm) cabinet clearance to motor for cooling purpose.
Note - Where possible, 6" (15.24 cm) is recommended for motor/blower service.
Side Clearance - Grills installed near a side wall must allow a minimum clearance of 8".
Access must be provided to remove and empty grease container(s).
8101 P580-60
(04-04-00)
InstallingCabinetryOver Your Jenn-Air Grill
*A = 30" (76.2 cm) minimum vertical clearance between
cooking surface and construction above the
appliance.
*B = 13" (33.02 cm) maximum depth of cabinets installed
above cooking top.
t_ i_ mmm
A ÷
Dotted lines
indicate
range hood
construction
* To eliminate associated potential hazards such as
reaching over open flames, avoid use of cabinets above
cooktop for storage space.
CabinetsAbove CookingTop
Maximum depth of cabinets installed above cooking top is
13 inches.
CAUTION: SOME CABINETS AND BUILDING
MATERIALS ARE NOT DESIGNED TO WITHSTAND
THE HEAT PRODUCED BY THE NORMAL SAFE
OPERATION OF A LISTED APPLIANCE.
DISCOLORATION OR DAMAGE, SUCH AS
DELAMINA- TION, MAY OCCUR.
WARNING
THISPRODUCTSHOULDNOT
BE INSTALLEDBELOWA
VENTILATIONTYPEHOOD
SYSTEMTHATDIRECTSAIR
IN A DOWNWARDDIRECTION.
(SEEFIGURE)
THESESYSTEMSMAYCAUSE
IGNITIONAND COMBUSTION
PROBLEMSWITHTHEGAS
BURNERSRESULTINGIN
___j[_ PERSONALINJURYAND MAY
AFFECTTHE COOKING
PERFORMANCEOFTHEUNIT.
ART # 9215-252
NOTE:THE FIGUREMAYNOTACCURATELYREPRESENT
YOUR RANGEORCOOKTOP;HOWEVER,THISWARNING
APPLIESTOALLGASCOOKINGPRODUCTS.
InstallationOf Appliance
Follow accompanying ducting instructions carefully.
This appliance is designed to always be vented outdoors.
The Countertop Cutout, Cabinet Front Cutout and Duct
Opening should be prepared according to the illustrations
on pages 1 and 2.
The installation of this appliance must conform with local
codes or, in the absence of local codes, with the latest
edition of the National Fuel Gas Code, ANSI Z223.1 USA
or current CAN/CGA-B149 INSTALLATION CODE.
This product must be installed by a licensed plumber or
gas fitter when installed within the Commonwealth of
Massachusettsl
A' T handle type manual gas va!ve must be installed in
the gas supply I neto this appliance.
A flexible gas connector; when used, must not exceed a
length of three (3)feet / 36 inches.
The electrical supply required is
110/120 Volt, A.C., 15 amp, 60
Hz. This appliance is equipped
with a grounded tpe power cord.
A grounded outlet must be pro-
vided. It is recommended, for
convenience, this outlet be lo-
cated in the area shown in the
shaded illustration (see figure 2).
Cabinet Bottom
Figure 2
User may experience occasional circuit tripping if Ground
Fault Circuit Interrupter (GFCl) outlet or breaker is in use.
This appliance, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the latest edition of the
National Electrical Code ANSI/NFPA No. 70 USA or
current CSA STANDARD C22.1 Canadian Electrical Code
)art 1.
ELECTRICAL GROUNDING INSTRUCTIONS
IS EQUIPPED WITH
THREE,PRONG GROUNDING PLUG FOR YOUR
PROTECTION AGAINST SHOCK HAZARD
SHOULD BE PLUGGED DIRECTLY INTO A
PROPERLY GROUNDED RECEPTACLE. DO NOT
CUT OR REMOVE THE GROUNDING PRONG FROM
THIS PLUG. .........................
2
ConnectingApplianceTo Gas Supply
,WARNING
Gas leaks may occur in your system and result in a
dangerous situation. Gas leaks may not be detected by
smell alone. Gas suppliers recommend you purchase and
install an UL approved gas detector. Install and use in
accordance with the manufacturer's instructions.
A QUALIFIED SERVICEMAN OR GAS APPLIANCE
INSTALLER MUST MAKE THE GAS SUPPLY
CONNECTION. Leak testing of the appliance shall be
conducted by the installer according to the
instructions given.
Install a manual shutoff valve in an accessible location in
the gas line external to this appliance for the purpose of
turning on or shutting off gas to the appliance.
Make the gas connection to the inlet to the appliance
pressure regulator on this appliance with a 112" male pipe
thread. Use an approved pipe joint compound resistant to
the action of LP gas at pipe connections. Test all joints for
gas leaks with a soap and water solution or other
accepted leak detection means. Never test for gas leaks
with an open flame.
High Altitude Notice
The specified gas burner ratings typically apply to
elevations up to 2000 feet. For higher altitudes, the rates
may need to be reduced to achieve satisfactory operation.
A local certified gas servicer will be able to advise if a
reduction is necessary.
Apply a non-corrosive leak detection fluid to all joints and
fittings in the gas connection between the supply line
shut-off valve and the range. Include gas fittings and
joints in the range if connections were disturbed during
installation. Check for leaks! Bubbles appearing around
fittings and connections will indicate a leak. If a leak
appears, turn off supply line gas shut-off valve and retest
for leaks. Never test for gas leaks with an open flame.
InstructionsTo Installer
1. Chamfer all exposed edges of decorative laminate to
prevent damage from chipping.
2. Radius corners of cutout and file to insure smooth
edges and prevent corner cracking. Recommend
1/4" or 3/8" diameter drill in each corner.
3. Rough edges, inside corners which have not been
rounded and forced fit can contribute to cracking of the
counter top laminate.
4. Countertop must be supported within 3" of cutout.
Minimum horizontal clearance between the edge of the
appliance and combustible construction extending from
the cooking surface to 18" (45.7 cm) above the cooking
surface is:
15/16" (2.38 cm) at rear
8" at sides
This is not the recommended clearance, but minimum
allowable clearance.
T--
18-
45,7 _)
t
(
Air Shutter Adjustment
This appliance is shipped from the factory with air
shutters adjusted for use with Natural Gas. If further
adjustment is necessary, or to reset for use with LP,
adjust air shutters as follows:
Grill Burnerand Surface BurnerCartridgeAir
Shutters (SeeIllustrations"A" & "B")
The left hand air shutter controls the rear half of the
burner. The right hand shutter controls the front half.
Access to air shutters on the surface burner cartridge may
be found through openings on the bottom of the cartridge
housing.
Slide air shutters backward or forward to increase or
decrease the size of the air opening. Air shutters fit
snugly, so a screwdriver blade may be required to make
this adjustment (see illustration).
Observe change in flame appearance as the air shutter is
moved. Adjustment is satisfactory when a clearly defined,
even blue flame results at the high flame setting. The
snug fit of the air shutter assures it will remain positioned
correctly.
Grill Burner Air Shutter and Surface Burner
.,___.,. (if so equipped)
:,: "%;"
L sc wo ,w ,.
SLOT AND TWIST WITH SLIGHT
PRESSURE TO ALLOW AIR SHUTTER
TO SLIDE EASILY
On any burner, closing the air shutter too far will cause
the flame to become soft and yellow tipped. Opening the
air shutter too wide will cause the flame to blow away
from the burner ports. Proper adjustment will produce a
sharp, clearly defined, even blue flame.
AIR SHUTTER
4
Low FlameAdjustment(See Illustration "C")
This appliance is shipped from the factory with low and
medium flame settings adjusted for use with Natural Gas.
If further adjustment is necessary, or to readjust for use
with LP, proceed as follows:
1. Light burner and set control knob for low flame.
2. Remove control knob from valve stem.
NEVER USE A METAL BLADE TO PRY KNOB OFF:
IF KNOB CANNOT BE EASILY REMOVED, TUCK THE
FOLDS OF A CLOTH DISHTOWEL UNDER THE KNOB
AND PULL THE TOWEL UPWARD WITH STEADY
EVEN PRESSURE.
3. Insert a slender, thin-blade screwdriver into the recess
at center of valve stem and engage blade with slot in
adjusting screw.
4. Turn center stem adjusting screw to set flame size.
clockwise to reduce.
counterclockwise to increase.
5. Replace control knob when adjustment is completed.
Proper adjustment will produce a stable, steady blue
flame of minimum size. The final adjustment should be
checked by turning knob from high to low several times
without extinguishing the flame.
This adjustment, at low setting, will automatically provide
the proper flame size at medium setting.
CLOCKWISE
TO REDUCE
FLAME SlZE
COUNTERCLOCKWISE TO
INCREASE FLAME SIZE
VALVE
STEM
PressureTesting
The maximum gas supply pressure for the appliance
pressure regulator supplied on this appliance is 14" W.C.
The test pressure for checking this appliance pressure
regulator must be at least 6" W.C. for Natural Gas, and at
least 11" W.C. for LP. It is shipped from the factory set for
Natural Gas at 5" W.C. output pressure.
This appliance and its individual shutoff valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 112" PSIG (3.5 k Pa).
This appliance must be isolated from the gas supply
piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2" PSIG
(3.5 k Pa).
AppliancePressureRegulatorConversion
(See Illustration "D")
This unit is supplied with a Maxitrol Appliance Pressure
Regulator. Follow the instructions in illustration "D".
MAXITROL APPLIANCE PRESSURE REGULATOR
CONVERTER_I LP
_A CAP I
ND PIN.,..-"
NAT I ..r ,'°
i.J !
APPLY DOWNWARD
FINGER PRESSURE
AT DISC EDGES TO
REPLACE PIN IN CAP
APPLY
_'t k SIDEWARD
FINGER
NAT T PRESSURE TO I LP
I REMOVE PIN i
FROM CAP @
ConversionTo LP Gas
This appliance is shipped from the factory equipped for
use with Natural Gas. To convert it from Natural Gas for
use with LP Gas, perform steps 1 through 4.
1. Remove natural gas orifice hoods. Install color coded
orifice hoods supplied, located in a pack attached to
the outer plenum area of this appliance. (See
Illustration "E", and LP Gas Conversion Instructions on
page 6).
2. Invert cap in convertible appliance pressure regulator (if
so equipped) located at entrance to gas manifold.
3. Adjust air shutters on individual burners for proper
flame appearance.
4. Adjust low flame setting at each burner by turning
adjustment screw in center of valve stem.
To make these conversion adjustments follow the
instructions and illustrations ("A" through "E" on
pages 4 - 5).
This appliance is shipped from the factory with orifice
hoods drilled for use with Natural Gas. To convert from
Natural Gas to LP, apply a 1/2" open-end wrench to hex
section of orifice hood. TURN COUNTERCLOCKWISE
TO REMOVE. Save the Natural Gas orifice hoods just
removed from this appliance for future use. Install color
coded orifice hoods supplied. (See LP Gas Conversion
Instructions above and page 6). TURN CLOCKWISE TO
INSTALL. Hold dimension specified in Illustration "E".
1/2" OPEN END
WRENCH
TURN
COUNTERCLOCKWISE
TO REMOVE
TURN
CLOCKWISE
TO TIGHTEN
ORIFICE HOOD
ControlSettings
The size and type of cookware and the amount and type
of food being cooked will influence the setting needed for
best cooking results. The setting indicated should serve
as a guide while you become familiar with your cooktop.
Use the HI flame setting to /_,_,
quickly bring foods to a boil or /F
to begin a cooking operation. _il_l_,_i_i)_ [ (
Then reduce to a lower __ [ i
setting to continue cooking. _ _,.._1\_
Never leave food unattended _
over a HI flame setting, i
Med setting is used to
continue a cooking opera-
tion. Food will not cook any
faster when a HI flame
setting is used than that is
needed to maintain a gentle
boil. Remember, water boils
at the same temperature
whether boiling gently or
vigorously.
Use Lo setting to keep food
at serving temperatures
without further cooking. You
may find that some cooking
may take place if the
cookware is covered.
|
MinimumSpacing Requirement
ConvertibleGasCooktops
For installing a Double Bay Downdraft
Cooktop in combination with another
Downdraft Cooktop, the minimum
spacing between adjacent units must
be provided, as shown, for satisfactory
performance.
13/16"
42.2 cm |
3/8"
X/4=_
DOUBLE BAY
DOUBLE BAY
TO CONVERTAPPLIANCEFOR USEWITH PROPANEGAS
Natural Gas To PropaneGas (LP) ConversionInstructions
A WARNING
Propane Gas conversion is to be performed by a
Jenn-Air Authorized Service Contractor (or other
qualified agency) in accordance with the
manufacturer's instructions and all codes and
requirements of the authority having jurisdiction.
Failure to follow instructions could result in serious
injury or property damage. The qualified agency
performing this work assumes responsibility for this
conversion.
Models - JGD8130 & JGD8345Series
A WARNING
ELECTRICALPOWERAND GAS MUST BE
TURNEDOFF PRIORTO CONVERSION
@
\
Manifold - Propane Gas pressure required - 10" W.C.
Incoming Propane Gas pressure required to appliance
pressure regulator- 11" - 12" W.C.
Propane Gas conversion orifice hoods are supplied with
these models.
Propane Gas input specified - JGD8130/JGD8345 -
33,000 BTU/hr / 51,000 BTU/hr.
TIE DOWN
BOLTON
EACHEND
GREASE
CONTAINER
REGULATOR
BLOWERCAN BE
(_ SWIVELED90"
JGD8345 (Shown)
Left Rear (LR) 7,500 #66 .0330 Zinc
Left Front (LF) 7,500 #66 .0330 Zinc
Right Rear (RR) 9,000 #63 .0370 Blue
Right Front (RF) 9,000 #63 .0370 Blue
Center Rear (CR) 9,000 #63 .0370 Blue
Center Front (CF) 9,000 #63 .0370 Blue
TO CONVERTAPPLIANCEFOR USEWITHNATURALGAS
PropaneGas(LP)ToNaturalGas
Conversion Instructions
If this appliance has been converted for use with LP
Gas, each of the following modifications must be
performed to convert the unit back to Natural Gas.
WARNING
Natural Gas conversion is to be performed by
a Jenn-Air Authorized Service Contractor (or
other qualified agency) in accordance with the
manufacturer's instructions and all codes and
requirements of the authority having jurisdic-
tion. Failure to follow instructions could result
in serious injury or property damage. The
qualified agency performing this work
assumes responsibility for this conversion.
Models - JGD8130& JGD8345Series
Manifold - Natural Gas pressure required - 5" W.C.
Incoming Natural Gas pressure required to appliance
pressure regulator - 6" - 7" W.C.
Natural Gas input specified, Model JGD8130/JGD8345 -
36,000 BTU/hr / 56,000 BTU/hr.
A. Replace all orifice hoods - Perform steps 1 through 4
on page 4. Locate the (4) four or (2) two Natural Gas
hoods (with small numbers stamped on their sides)
saved from the original Natural Gas unit. Page 5
Illustration "E". The two hoods with .0520 (#55 orifice)
stamped on them are for the left front and left rear
burners. The two hoods with the .0550 (#54 orifice)
stamped on them are for the two right burners.
To make these conversion adjustments follow the
instructions and illustrations ("A" through "E")
pages 4 and 5.
B. Invert cap in appliance pressure regulator (see
Illustration "D"). With the appliance installed, the
appliance pressure regulator is located on the center
underside of the appliance at the inlet to the gas
manifold. Identify the type of appliance pressure
regulator on the unit and follow the instructions in the
appropriate illustration.
C. Adjust low flame setting for each burner. Follow the
instructions for burner low flame adjustment on page
4 to increase the simmer flame size.
JGD8345 (Shown)
REGULATOR
TIE DOWN
BOLTON
EACHEND BOXCOVER
GREASE
CONTAINER BLOWERCANBE
SWIVELED90°
BURNER. BTU/hr ORIFICE DIAMETER COLOR
Left Rear (LR) 8,000 #55 .0520 Brass
Left Front (LF) 8,000 #55 .0520 Brass
Right Rear (RR) 10,000 #54 .0550 Brass
Right Front (RF) 10,000 #54 .0550 Brass
Center Rear (CR) 10,000 #54 .0550 Brass
Center Front (CF) 10,000 #54 .0550 Brass
REQUIREDADJUSTMENTSATTIME OF INSTALLATION
The installation of this appliance must conform with local codes, or in the absence of local codes, with
the latest edition of the National Fuel Gas Code ANSI Z223.1 USA or current CAN/CGA-B149 Installation
Code.
This range was manufactured for use with Natural Gas. If LP gas is the fuel of choice, follow the conversion
to LP procedure found in the installation instructions.
Test all external connections for gas leaks. Never test for gas leaks with an open flame.
Test all electrical connections.
Adjust all air shutters for proper flame.
Adjust all valves for low flame settings.
[_ Test the ventilation system for proper installation.
If a problem exists with the downdraft system, check the ducting installation to make sure it conforms to
the Jenn-Air specifications. Most downdraft system problems are attributed to poor ducting practices.
Contact your installer if the ventilation system will not remove smoke or cooking fumes from well trimmed
cuts of meat.
If ventilation problems persist contact your authorized Jenn-Air Service Contractor.
=JENN-AIR
403WESTFOURTHSTREET,NORTH° NEWTON,IA50208
SUPERFICIE PARACOCINAR CON
ASADOR DE GAS CONVERTIBLE
SERIES JGD8130 Y JGD8345
======,,,,,,.,,,,
403WESTFOURTHSTREET,NORTH*NEWTON, IA 50208
LAS DIMENSIONES SE MUESTRAN EN PULGADAS Y CENTiMETROS
* El ventilador puede girarse para colocarlo en posici6n vertical u horizontal aflojando las tuercas de alrededor de la entrada
del ventilador. Camara interior accesible de ventilaci6n.
AVISO AL INSTALADOR: Deje estas instrucciones con el aparato.
AVlSO AL CONSUMIDOR: Conserve estas instrucciones para consultarlas en el futuro.
DE
PRESIONDELAPARATO
PERNOpE
SUJECIONEN
CADAEXTREMO
RECIPIENTE DELCABLEADO
ELVENTILADOR DEGRASA
PUEDE GIRARSE 90 ° + 1/16"
29" +1/
73,66 cm 34 cm
8;m
15/16" ! /__
Min.
Espacio
libre
2,38 cm
SELECCIONEEL I
CORTEPARADUCTO
APROPIADO(VEA
LASINSTRUCCIOI_ES
DELA INSTALACION
DEDUCTOS). RECIPIENTE
DE GRASA
il
r
t 31_2,,i o \ o
1 8,8cm [ _,
' I II I
_ DELAPARATO
/
2 7/8" _ _ 13 3/4" _ 11 13/16" -_
7,3 cm 34,9 cm = 30,0 cm
7 9/16"
19,21 cm
PERNOpE
SUJECIONEN
CADAEXTREMO
ELVENTILADOR
PUEDEGIRARSE90°
RECIPIENTE
DEGRASA
REGUI._ADORDE
PRESIONDELAPARATO
CUBIERTADE LACAJA
DELCABLEADO
43 1/4" +1/1 21" +1/16"
109,86 cm 53,34 cm
_ 79/16"
_k_'_. _ 9 3/8" I 1 7/8"
Min.
15/16" _'_"_ 23'81 cm ! 4,76 cm
Min. I '_
Espacio I M "_1
libre I _ / . l
SELECCIONE_
CORTEPARADUCTO /7,x\
APROPIADO(VEALAS_ "
INSTRUCCION,ESDE
LAINSTALACIONDE
DUCTOS). RECIPIENTE
DEGRASA
/
Q
t 31/2"I _ /
1 8'8cmI /
! _ II I REGULADOR
/ _1 I DEPRESION
_ DELAPARATO
2 7/8" _ _ 13 3/4" -_ 26 3/4"
7,3 cm 34,9 cm 68,0 cm
.A o _
INSTRUCCIONESPARAEL INSTALADOR
Dimensi6n "A" - Proporcione 2" min. (5,08 cm) de espacio libre del gabinete al motor para
fines de enfriamiento.
Nota - En donde sea posible, se recomienda un espacio de 6" (15,24 cm) para poder
darle servicio al motor o al ventilador.
Espacio libre lateral--Los asadores instalados cerca de una pared
lateral deberan tener cuando menos un espacio libre de 8" (20 cm)
Debe proporcionarse acceso para quitar y vaciar los recipientes de grasa.
GRIL A GAZ CONVERTIBLE
SI_RIEPLAQUESDE CUISSON
JGD8130ET JGD8345
403WESTFOURTHSTREET,NORTH NEWTON,IA J
50208, ETATS-UNIS //
DIMENSIONSEN POUCESET EN CENTIMI_TRES
*Le ventilateur peut 6tre tourne pour I'orienter a I'horizontale ou a la verticale en d6vissant les 6crous qui se trouvent sur le
p6rim6tre de I'arriv6e d'air. Accessible a I'int6rieur de la chambre de ventilation.
NOTE A L'INTENTION DE L'INSTALLATEUR : Veuillez laisser ces instructions avec I'appareil.
NOTE A L'INTENTION DE L'UTILISATEUR • Veuillez conserver ces instructions pour r6f6rence ult6rieure.
DEL'APPAREIL
BOULOND,E
FIXATIONA,CHAQUE
EXTREMITE DECABLAGE
LEVENTILATEUR BECIPIENT
PEUTPIVOTER A GRAISSE
DE90°
_"'1 29" + 1/
. 73,7cm
?,
CONDUIT(VOIR LES
CONSIGNESDE POSE
DESCONDUITS). _
l 3 1/_"
8,8 cm
13 13116"
35,1 cm
+1/16"
3 cm
RECIPIENT
_, GRAISSE
2 7/8"
7,3 cm
7 9/16"
19,2 cm
/
13 3/4" _ 11 13/16"
34,9 cm / 30,0 cm
BOULONEE
FIXATIONA CHAQUE
EXTREMITE
DETENDEUR
DEUAPPAREIL
DECABLAGE
LEVENTILATEUR BI_CIPIENT
PEUTPIVOTER AGRAISSE
DE90°
43 1/4"+ 1/ 21" + 1/16"
,__,._ ]09,9cm 53,3cm
9 3/8" 17/8"
8 cm rain.
15/16"min. 4,8cm
D6gagement
2,4crn
SI_LECTIONNER_E
DECOUPE QUI
CONVIENT POUR _ "
CONDUIT(VOIR LES
CONSIGNESDE POSE
DESCONDUITS). I_ECIPIENT
A GRAISSE
3 1/2"
8,8 cm
1313/16,,I I _ I_."
35,1 cm
2 7/8" 13 3/4" 26 3/4"
7,3 cm 34,9 cm 68,0 cm
CONSIGNESA L'INTENTIONDE L'INSTALLATEUR
Dimension <<A >>- Prevoir 2 po min. (5,1 cm) de d6gagement par rapport a I'armoire pour permettre le
refroidissement du moteur.
Note - Chaque fois que cela est possible, un degagement de 6 po (15,2 cm) est recommande pour
permettre I'acces au moteur/ventilateur en cas de panne.
Degagement sur le c6te - Les gril montes pres d'une cloison laterale doivent avoir un
degagement de 8 po (15,2 cm) minimum.
L'acces dolt 6tre prevu afin de permettre de retirer et de vider le ou les recipients
graisse.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Jenn-Air JGD8130ADS20 Installation guide

Category
Barbecues & grills
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI