Toro Block Heater Kit, RT1200 Trencher Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Toro Block Heater Kit, RT1200 Trencher Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
FormNo.3378-127RevA
BlockHeaterKit
RT1200Trencher
ModelNo.25468
ModelNo.25468E
InstallationInstructions
Installation
WARNING
CALIFORNIA
Proposition65Warning
ThisproductcontainsachemicalorchemicalsknowntotheStateofCaliforniato
causecancer,birthdefects,orreproductiveharm.
1
PreparingtoInstalltheBlock
Heater
NoPartsRequired
DrainingtheCoolant
WARNING
Coolantistoxic.
Keepcoolantawayfromchildrenandpets.
Ifnotreused,disposeofcoolantinaccordance
withlocalgovernmentregulations.
WARNING
Heatedcoolantsprayorsteamcancausepersonal
injury.
Donotremovetherecoverytankcapwhenthe
engineishot.
Waituntilthecoolanttemperatureisbelow50°C
(120°F)beforeremovingtherecoverytankcap.
Important:Donotpourcoolantontothegroundorinto
anunapprovedcontainerthatcanleak.
1.Movethemachinetoalevelsurface,shutoffthe
engine,andremovethekeyfromthekeyswitch.
2.Allowtheengineandcoolingsystemtocool.
3.Removetheleftandrightsidepanels;refertoOperator’s
Manualforthemachine.
4.Removetherecovery-tankcapfromthetank(Figure1).
1
2
g024982
Figure1
1.Recovery-tankcap2.Fillerneck
5.Placeadrainpanwithaminimumcapacityof23L
(6USgallons)undertheopenendofthedrainhose
(Figure3).
©2014—TheToro®Company
8111LyndaleAvenueSouth
Bloomington,MN55420
Registeratwww.Toro.com.
OriginalInstructions(EN)
PrintedintheUSA
AllRightsReserved
*3378-127*A
Figure2
1.Drainhose
6.Openthedrainvalveontheradiatorandallowthe
coolanttodraincompletely.
Note:Disposeoftheusedcoolantproperlyaccording
tolocalcodes.
Figure3
1.Drainvalve
7.Closethedrainvalve(Figure3).
RemovingtheFreezePlug
1.Locatetheforwardfreezeplugattherightsideofthe
engine.
Figure4
1.Freezeplug(rightsideofengine)
2.Removethefreezeplug.
Figure5
3.Thoroughlycleantheholeintheengineblockwitha
rag.
Note:Ensurethattherearenoburrs,metalshavings,
orsharpedgesthatcancuttheO-ring.
2
2
InstallingtheBlockHeaterKit
Partsneededforthisprocedure:
1Blockheater
2
Flanged-headbolts(8x16mm)
1Heater-electricalcord
1
Cabletie
Procedure
1.LubricatetheO-ringontheblockheaterwith15W-40
engineoil.
2.Inserttheblockheaterintotheholeintheengineblock
withtheelementoftheheaterpointingdown(Figure
6).
Figure6
1.Flanged-headbolts(8x
16mm)
3.Blockheater
2.Heaterelement
4.Hole(engineblock)
3.Aligntheholeintheblockheaterwiththeholeinthe
engineblock(Figure6).
4.Securetheblockheatertotheblock(Figure6)withthe
2anged-headbolts(8x16mm).
5.Torquetheboltsto24N-m(212in-lb).
6.Connecttheconnectoroftheheater-electricalcordto
theconnectoroftheblockheater(Figure7).
Figure7
1.Connector(electricalcord)2.Connector(blockheater)
7.Routethecordoverthetopoftheright-framechannel
ofthemachine(Figure8).
Figure8
1.Cabletie3.Chargecable(alternator)
2.Plug(electricalcordforthe
blockheater)
4.Right-framechannel
8.Securetheelectricalcordoftheblockheatertothe
chargecableofthealternatorwithacabletie(
Figure8)
3
3
FillingtheCoolingSystem
withAntifreeze
NoPartsRequired
Procedure
Thecoolantcapacityoftheengineandtheradiator:18.5
L(19.5USqt).
Important:Fillthecoolingsystemproperlytoprevent
airlocksinthecoolingpassages.Failingtoventthe
coolingsystemproperlycandamageboththeengine
andthecoolingsystem.
Important:Neverusesealingadditivetostopleaks
inthecoolingsystem.Thiscanresultinthecooling
systempluggingandinadequatecoolantow,causing
theenginetooverheat.
1.Removetheradiatorcapfromtherecoverytank
(Figure1).
2.Fillthecoolingsystemwiththespeciedcoolant
mixture(Figure9)untiltheuidlevelisuptothe
midpointinthesightgauge(Figure9).
Figure9
1.Coolantlevel(midpointin
thesightgauge)
3.Coolant(amixtureof50%
ethyleneglycoland50%
water)
2.Funnel
3.Installtherecovery-tankcap(Figure1).
4.Starttheengineandrunitathalfthrottlefor5minutes.
5.Stoptheengineandremovethekey.
6.Wait30minutes,thenchecktheuidlevelinthe
recoverytank.
Note:Ifthecoolantlevelislow,addcoolanttothe
recoverytankuntiltheuidlevelisuptothemidpoint
ofthesightgauge.
7.Installthesidepanels;refertoOperator’sManualforthe
machine.
Operation
UsingtheBlockHeater
ConnectingtheBlockHeaterto
ElectricalPower
Electricalsourcespecication:110to120voltsAC
Note:Toreducetheriskofelectricshock,thisappliance
hasapolarizedplug(i.e.,uniquebladeshapesandwidths).
UseonlyapolarizedsocketthatiscompliantwithNEMA
specicationsattheelectricalsource,andpolarizedextension
cordsthatareUL-listed(CSAcertiedinCanada)for
outdooruse.Apolarizedplugoftheelectricalcordforthe
blockheaterwilltinapolarizedcordonlyoneway.If
youdonothaveanoutletthatisgroundedandpolarized,
contactaqualiedelectriciantoinstalltheproperoutlet.Do
notmodifytheelectricalcordfortheblockheaterorthe
extensioncordpluginanyway.
1.Beforeparkingthemachine,moveitclosetotheoutlet
thatwillserveastheelectricalsourcefortheblock
heater.
2.Settheparkingbrake,shutofftheengine,andremove
thekeyfromthekeyswitch.
3.Iftheelectricalcordfortheblockheaterisinsidethe
enginecompartment,removetherightsidepanel;refer
totheOperator’sManualforthemachine.
4.Plugtheelectricalcordfortheblockheaterintoa
grounded-typeextensioncord(Figure10).
Important:Useonly3-wireextensioncordswith
terminalsandsocketsforthelive,neutral,and
groundcircuits.
Usetheshortestextensioncordpossibleandin
1piece.
Note:Whenusinganin-linegroundfaultcircuit
interrupter(GFCI)device,locatetheGFCIascloseto
theelectricalsourceaspossible.
4
Figure10
1.Electricalcord(block
heater)
4.In-lineGFCI
2.Extensioncord
5.Grounded-electricaloutlet
3.Driploop
5.Stowtheconnectorsoftheblock-heatercordand
extensioncordinsidetheenginecompartmentofthe
machine.
6.Routetheextensioncordtoformadriploopbelow
theconnectionattheblock-heatercordandextension
cord,andtheconnectionattheextensioncordandthe
receptaclefortheelectricalsource(Figure10).
7.Connectagroundedextensioncordintothe
grounded-electricaloutletthatwillserveasthe
electricalsourcefortheblockheater(Figure10).
Important:Connecttheblockheatertoa3-pole
receptaclewithlive,neutral,andgroundcircuits
only.
8.Installtherightsidepanel;refertotheOperator’sManual
forthemachine.
DisconnectingtheBlockHeaterfrom
ElectricalPower
1.Disconnecttheextensioncordfromtheoutletthatis
servingastheelectricalsourcefortheblockheater
(Figure10).
2.Removetherightsidepanel;refertotheOperator’s
Manualforthemachine.
3.Disconnectthecordoftheblockheatercordintothe
extensioncord(Figure10).
4.Stowthecordoftheblockheaterintheengine
compartment,awayfrommovingparts.
5.Installtherightsidepanel;refertotheOperator’sManual
forthemachine.
5
Notes:
6
Notes:
7
/