M38 TAP
1” PF TAP
(in side)
M38 TAP
M38 TAP
HDA 401(PF 1”)
CEILING
WALL
* EXPLODE VIEW
1. ASSEMBLY PARTS LIST
PLASTIC BUSHING
MACHINE SCREW
PLATE
MOUNT BASE
SCREW TAPPING
PIPE (90 ANGLE TYPE)(Option)
PIPE (STRAIGHT TYPE)(Option)
SEAL TAPE
SET SCREW
L-WRENCH
MACHINE SCREW
ANCHOR ( Φ6.0mm)
UNC #8-32 SCREW (L=8mm)
Gl 1.6t
M38 TAP, ALUMINUM
M6, L = 35.0mm
PT 1" M38 TAP, ALUMINUM
PT 1" M38 TAP, ALUMINUM
TEFLON
M5 x 5.0mm
M6 x 12.0
1
2
3
4
5
6
7
8
9
10
11
3
2
1
1
3
1
1
1
2
1
3
ITEM
Q’TY
PART NAME
DESCRIPTION
2. INSTALLATION
3. Fit the pipe (of which threads are covered by teflon tape) into the mount base ( ) and turn
until it is securely fastened.
1. Attach the mount base ( ) and plate ( )to the ceiling or wall using the supplied M6
tapping screws ( ) and plastic bushings( )
(Please refer to page 3 for an assembly drawing of the of plate)
4. Pull all the required cables through the mount base( ) and pipe( , ).
HDA 401[PF 1”]
7. Fasten the vandal proof dome housing to the dome adaptor ( ) Wind
Teflon tape ( ).
2. Wind Teflon tape ( ) around both threaded ends of the pipe (about 20times) for sealing.
If necessary, use a sillicone rubber sealant to seal the area where the mount base and the
pipe meet.
HDA 401[PF 1”]
6. Fasten the mount base ( ), dome adaptor ( ) using the set screw ( ).
5. Align the dome adaptor ( ) with the pipe and turn until it is securely fastened.
HDA 401[PF 1”]
* How to install the plate
Ex1. Without junction box
* Attention to the plate side.
Cable Cable
Junction box
Ex2. With junction box Ex3. Install the Conduit box
Pipe
Conduit box