Abstract
This document describes disk drive firmware support for all P6000 EVA models (EVA3000/5000, EVA4000/6000/8000,
EVA4100/6100/8100, EVA4400/6400/8400, and P6300/P6500 EVA).
HP Part Number: 5697-1869
Published: April 2012
Edition: 16
© Copyright 2008-2012 Hewlett-Packard Development Company, L.P.
Description
This document lists the supported Fibre Channel, near-online FATA (Fibre Channel Advanced
Technology Attachment), SSD (solid state disk), and SAS (serial-attached SCSI) disk drive models
and firmware versions for all currently active VCS and XCS controller software versions. HP
recommends that you always maintain your array at active controller software versions.
P6000, used throughout this document, is the current branding for the Enterprise Virtual Array
product family.
NOTE:
The information in this document is current as of the publication date.
To maintain your storage system at the most current configuration, HP recommends that all
disk drives use the recommended version of firmware.
For disk drive guidelines and best practices, see the Enterprise Virtual Array configuration best
practices white paper for the appropriate array model. The white papers are available at the
following website:
http://h18006.www1.hp.com/storage/arraywhitepapers.html?jumpid=reg_R1002_USEN
Product models
HP EVA3000/5000 Enterprise Virtual Arrays
HP EVA4000/6000/8000 Enterprise Virtual Arrays
HP EVA4100/6100/8100 Enterprise Virtual Arrays
HP EVA4400/6400/8400 Enterprise Virtual Arrays
HP P6300/P6500 Enterprise Virtual Arrays
NOTE: HP Command View EVA 9.4 is the only active version that supports the EVA3000/5000
family.
Devices supported
Table 1 (page 3) through Table 10 (page 8) list the supported disk drives. You can use a
combination of drive types if they support a mutual version of controller software and firmware.
Fibre Channel disk drives
Table 1 10K RPM Fibre Channel drives
Supported controller
software version
Recommended
firmware version
Minimum supported
firmware version
HP model displayed in HP
P6000 Command View
Type
3.110,
1
4.100,
1
6.2x03BE93BE9BD0365449936 GB, 10K RPM
3.110,
1
4.100,
1
6.2x0HP07HP05BD03655B28
3.110,
1
4.100,
1
6.2x0HP0AHP09BD03656ABA
3.110,
1
4.100,
1
6.2x0HP05HP02BD03659532
3.110,
1
4.100,
1
6.2x03BE93BE9BD0725449872 GB, 10K RPM
3.110,
1
4.100,
1
6.2x0HP07HP05BD07255B29
3.110,
1
4.100,
1
6.2x0HP0AHP09BD07256ABB
3.110,
1
4.100,
1
6.2x0HP04HP01BD07258224
Description 3
Table 1 10K RPM Fibre Channel drives (continued)
Supported controller
software version
Recommended
firmware version
Minimum supported
firmware version
HP model displayed in HP
P6000 Command View
Type
3.110,
1
4.100,
1
6.2x0HP05HP01BD0725822B
3.110,
1
4.100,
1
6.2x0HP0AHP09
2
BD14656ABC146 GB, 10K
RPM
3.110,
1
4.100,
1
6.2x0HP04HP01BD14658225
3.110,
1
4.100,
1
6.2x0HP07HP05BD14655B2A
3.110,
1
4.100,
1
6.2x0HP05HP01BD1465822C
3.110,
1
4.100,
1
6.2x0HP01HP01BD1465B778
3.110,
1
4.100,
1
6.2x0,
0953x000, 10000000
or later
HP01HP00BD300DAJZF300 GB, 10K
RPM
3.110,
1
4.100,
1
6.2x0HP04HP00BD30058226
3.110,
1
4.100,
1
6.2x0HP05HP00BD30058232
3.110,
1
4.100,
1
6.2x0HP01HP01BD3005B779
3.110,
1
4.100,
1
6.2x0HP03HP02BD300DADFP
0953x000, 10000000
or later
HP03HP01BD400DADFQ400 GB, 10K
RPM
6.2x0, 0953x000,
10000000 or later
HP01HP00BD450DAJZH450 GB, 10K
RPM
6.2x0, 0953x000,
10000000 or later
HP01HP00BD600DAJZK600 GB, 10K
RPM
1
VCS 3.110 and 4.100 are inactive software versions but remain the latest and only recommended versions for use with
EVA3000/5000. HP Command View EVA 9.4 is the only active version that supports the EVA3000/5000 family.
2
On VCS 3.110, the minimum supported version is HP0A.
Table 2 15K RPM Fibre Channel drives
Supported controller
software version
Recommended
firmware version
Minimum supported
firmware version
HP model displayed in HP
P6000 Command View
Type
3.110,
1
4.100,
1
6.2x0HP03HP01BF0365300536 GB, 15K RPM
3.110,
1
4.100,
1
6.2x03BE93BE9BF03654564
3.110,
1
4.100,
1
6.2x0HP07HP05BF03655B2B
3.110,
1
4.100,
1
6.2x0HP03HP00
2
BF03658242
3.110,
1
4.100,
1
6.2x0HP07HP04BF036D8617
3.110,
1
4.100,
1
6.2x0HP03HP02BF036DAJZL
3.110,
1
4.100,
1
6.2x0HP07HP05BF07255B2C72 GB, 15K RPM
3.110,
1
4.100,
1
6.2x0HP06HP05BF0725754B
3.110,
1
4.100,
1
6.2x0HP03HP00BF07258243
3.110,
1
4.100,
1
6.2x0HP06HP04BF07258222
3.110,
1
4.100,
1
6.2x0HP04HP01BF0725A692
3.110,
1
4.100,
1
6.2x0HP03HP00BF0725A476
3.110,
1
4.100,
1
6.2x0HP07HP04BF072D6186
4
Table 2 15K RPM Fibre Channel drives (continued)
Supported controller
software version
Recommended
firmware version
Minimum supported
firmware version
HP model displayed in HP
P6000 Command View
Type
3.110,
1
4.100,
1
6.2x0HP03HP02BF072DAJZN
3.110,
1
4.100,
1
6.2x0HP03HP00BF14658244146 GB, 15K RPM
3.110,
1
4.100,
1
6.2x0HP06HP04BF14658227
3.110,
1
4.100,
1
6.2x0HP04HP01BF1465A693
3.110,
1
4.100,
1
6.2x0HP03HP00BF1465A477
3.110,
1
4.100,
1
6.2x0, 0953x000,
10000000 or later
HP04HP00BF146DA47A
3.110,
1
4.100,
1
6.2x0, 0953x000,
10000000 or later
HP07HP04BF146DA47C
3.110,
1
4.100,
1
6.2x0, 0953x000,
10000000 or later
HP03HP02BF146DAJZP
3.100,
1
4.100,
1
6.2x0, 0953x000,
10000000 or later
HP02HP00BF300DASTH300 GB, 15K RPM
3.110,
1
4.100,
1
6.2x0HP03HP00BF3005A478
3.110,
1
4.100,
1
6.2x0, 0953x000,
10000000 or later
HP04HP00BF300DA47B
3.110,
1
4.100,
1
6.2x0, 0953x000,
10000000 or later
HP07HP04BF300DA482
3.110,
1
4.100,
1
6.2x0, 0953x000,
10000000 or later
HP04HP02BF300D6188
3.110,
1
4.100,
1
6.2x0, 0953x000,
10000000 or later
HP03HP02BF300DAJZQ
6.2x0, 0953x000,
10000000 or later
HP02HP00BF450DASTK450 GB, 15K RPM
6.2x0, 0953x000,
10000000 or later
HP07HP04BF450DA483
6.2x0, 0953x000,
10000000 or later
HP04HP02BF450D6189
6.2x0, 0953x000,
10000000 or later
HP03HP02BF450DAJZR
6.2x0, 0953x000,
10000000 or later
HP02HP00BF600DASTL600 GB, 15K RPM
6.2x0, 0953x000,
10000000 or later
HP03HP02BF600DAJZT
1
VCS 3.110 and 4.100 are inactive software versions but remain the latest and only recommended versions for use with
EVA3000/5000. Only HP Command View EVA Version 9.4 and earlier support the EVA3000/5000 family.
2
On VCS 3.110, the minimum supported version is HP01.
Devices supported 5
Table 3 Near-online (FATA) disk drives
Supported controller
software version
Recommended
firmware version
Minimum supported
firmware version
HP model displayed in HP
P6000 Command View
Type
3.110,
1
4.100,
1
6.2x0HP04HP00ND2505823A250 GB, 10K RPM
3.110,
1
4.100,
1
6.2x0HP05HP00ND25058238
3.110,
1
4.100,
1
6.2x0HP00HP00ND2505AGXU
3.110,
1
4.100,
1
6.2x0HP03HP02NB40059392400 GB, 7.2K RPM
3.110,
1
4.100,
1
6.2x0HP03HP02NB50058855500 GB, 7.2K RPM
3.110,
1
4.100,
1
6.2x0HP07HP03
2
NB500DA48A
6.2x0, 0953x000,
10000000 or later
HP07HP03
2
NB1000D44501 TB, 7.2K RPM
6.2x0, 0953x000,
10000000 or later
HP01HP00NB1000DCLAL
6.2x0, 0953x000,
10000000 or later
HP02HP00NB1000DBZPL
10000000 or laterHP03HP02NB2000DAMYV2 TB, 7.2K RPM
3
10000000 or laterHP02HP00NB2000DBZPN
1
VCS 3.110 and 4.100 are inactive software versions but remain the latest and only recommended versions for use with
EVA3000/5000. HP Command View EVA 9.4 is the only active version that supports the EVA3000/5000 family.
2
HP strongly recommends that you use the recommended version of HP07. If you add a disk drive that is running firmware
version HP03 to an array, ensure that you first power off the array.
3
For EVA4400/6400/8400 models only. The capacity limit per disk group is 400 TB. This capacity limit is any combination
of drives in a disk group that results in a total physical capacity of up to 400 TB, for example, 200 2 TB drives or 400
1 TB drives. See the QuickSpecs on these array models for their maximum addressability limits and maximum array
sizes. This drive is supported with XCS 10000000 and later.
Fibre Channel SSD drives
NOTE: Fibre Channel SSD drives are not supported on the P6300/P6500 Enterprise Virtual
Array.
Table 4 0 RPM Fibre Channel SSD drives
Supported controller
software version
Recommended
firmware version
Minimum supported
firmware version
HP model displayed in HP
P6000 Command View
Type
0953x000, 10000000
or later
HP03HP01JL0072DAKXK72 GB, 0 RPM
09534000, 10000000
or later
HP03HP02JL0200DBCQQ200 GB, 0 RPM
09534000, 10000000
or later
HP03HP02JL0400DBCQR400 GB, 0 RPM
6
SAS disk drives
NOTE: SAS disk drives are supported only on the P6300/P6500 Enterprise Virtual Array.
Table 5 10K Small Form Factor SAS drives
Supported controller
software version
Recommended
firmware version
Minimum supported
firmware version
HP model displayed in HP
P6000 Command View
Type
10000000 or laterHPD6HPD5EG0300FBDBR300 GB, 10K RPM
10000000 or laterHPD5HPD5EG0300FBLSE
10000000 or laterHPD6HPD5EG0450FBDBT450 GB, 10K RPM
10000000 or laterHPD5HPD5EG0450FBLSF
10000000 or laterHPD6HPD5EG0600FBDBU600 GB, 10K RPM
10000000 or laterHPD5HPD5EG0600FBLSH
10000000 or laterHPD5HPD5EG0900FBLSK900 GB, 10K RPM
Table 6 15K Small Form Factor SAS drives
Supported controller
software version
Recommended
firmware version
Minimum supported
firmware version
HP model displayed in HP
P6000 Command View
Type
10000000 or laterHPDGHPDFEH0146FAWJB146 GB, 15K RPM
10000000 or laterHPD1HPD1EH0146FBQDC
10000000 or laterHPD1HPD1EH0300FBQDD300 GB, 15K RPM
Table 7 15K Large Form Factor SAS drives
Supported controller
software version
Recommended
firmware version
Minimum supported
firmware version
HP model displayed in HP
P6000 Command View
Type
10000000 or laterHPD5HPD3EF0300FARMU300 GB, 15K RPM
10000000 or laterHPD7HPD7EF0300FATFD
10000000 or laterHPD5HPD3EF0450FARMV450 GB, 15K RPM
10000000 or laterHPD7HPD7EF0450FATFE
10000000 or laterHPD5HPD3EF0600FARNA600 GB, 15K RPM
10000000 or laterHPD7HPD7EF0600FATFF
Table 8 7.2K Small Form Factor Midline SAS drives
Supported controller
software version
Recommended
firmware version
Minimum supported
firmware version
HP model displayed in
HP P6000 Command
View
Type
10000000 or laterHPD5HPD4MM0500FAMYT500 GB, 7.2K RPM
10000000 or laterHPD5HPD5MM0500FBFVQ
10000000 or laterHPD5HPD5MM1000FBFVR1 TB, 7.2K RPM
Devices supported 7
Table 9 7.2K Large Form Factor Midline SAS drives
Supported controller
software version
Recommended
firmware version
Minimum supported
firmware version
HP model displayed in
HP P6000 Command
View
Type
10000000 or laterHPD5HPD3MB2000FAMYV2 TB, 7.2K RPM
10000000 or laterHPD1HPD1MB2000FBZPN
10000000 or laterHPD3HPD3MB2000FBUCL2 TB, 7.2K RPM
Table 10 SSD SAS drives
Supported controller
software version
Recommended
firmware version
Minimum supported
firmware version
HP model displayed in
HP P6000 Command
View
Type
10000000 or laterHPD5HPD5EO0200FBRVV200 GB, 0 RPM
10000000 or laterHPD5HPD5EO0400FBRWA400 GB, 0 RPM
Downloading disk drive firmware
You can download the disk drive firmware bundled image and installation instructions from:
www.hp.com/support/evadiskfirmware
For the EVA3000/5000, EVA4000/6000/8000, EVA4100/6100/8100 and
EVA4400/6400/8400 families, select the HP EVA FC Hard Disk Drive Firmware Bundle, and
then click Download.
For the P6000 array family, select the HP P6000 EVA SAS Hard Disk Drive Firmware Bundle,
and then click Download.
For instructions to download and install the firmware bundled images, see Finding Disk Drive
Firmware Images Read This First file located at the same website.
8
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

HP EVA3000 Firmware Support

Type
Firmware Support

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI