1.3 Specications
Designation, model ..........S5 ................S6 ................S8 ............... S10 ............. S13 ................ S16
Nominal heating performances (outside temperature/ initial temperature)
Heat output
+7 °C / +35 °C - Floor heating system kW........ 4,60 ..............6,50 .............8,00 ............10,30 ........... 13,70 .............16,20
-7 °C / +35 °C - Floor heating system kW........ 4,80 ..............5,60 .............6,65 .............8,10 ............ 11,55 .............12,40
+7 °C / +45 °C - Low temperature radiator kW........ 4,17 ..............5,40 .............6,20 .............8,30 ............. 9,70 ..............13,30
-7 °C / +45 °C - Low temperature radiator kW........ 4,05 ..............5,10 .............5,78 .............7,00 ............. 9,20 .............. 11,00
Power absorbed
+7 °C / +35 °C - Floor heating system kW........ 1,07 ..............1,63 .............2,11 .............2,58 ............. 3,42 ................4,15
-7 °C / +35 °C - Floor heating system kW........ 1,77 ..............2,24 .............2,89 .............3,52 ............. 4,37 ................4,77
+7 °C / +45 °C - Low temperature radiator kW........ 1,23 ..............1,61 .............2,07 .............2,51 ............. 2,98 ................4,20
-7 °C / +45 °C - Low temperature radiator kW........ 1,78 ..............2,32 .............2,97 .............3,33 ............. 4,30 ................5,37
Nominal coefcient of performance (COP)
(+7 °C / + 35 °C) -........ 4,30 ..............4,00 .............3,80 .............4,00 ............. 4,00 ................3,90
Electrical characteristics
Supply voltage (50 HZ) V.........230 .............. 230 .............. 230 .............. 230 ...............230 ..................230
Maximum current of the appliance A..........15 ................ 15 ................ 15 ................ 17 .................20 .....................26
Nominal intensity A......... 8,3 ................8,3 ..............10,6 .............11,7 ............. 16,7 ................20,6
Maximum current of the electrical back-ups A..........13 ................ 13 ................ 13 ...............26,1 .............26,1 ................26,1
Power of the electrical back-ups kW...........3 .................. 3 .................. 3 .................. 6 ...................6 ........................6
Real power absorbed
- By the fan W..........54 ................ 54 ................ 65 ............... 103 .............2x103 ............ 2x103
- By the circulation pump W......... 113 .............. 113 .............. 113 ...............113 ...............151 ..................151
Maximum power absorption
- By the outside unit W........3450 ............ 3450 ............ 3450 ............ 3910 .............4600 ...............5980
Hydraulic circuit
Maximum operating pressure bar...........3 .................. 3 .................. 3 .................. 3 ...................3 ........................3
Hydraulic system ow rate
4°C<Δt<8°C (nominal conditions)
- minimum l/h.........540 .............. 600 .............. 860 ............. 1000 .............1380 ...............1670
- maximum l/h........ 1100 ............ 1400 ............ 1700 ............ 2100 .............2700 ...............3300
Various
Weight of outside unit kg..........40 ................ 40 ................ 44 ................ 64 .................98 ...................105
Noise level at 5 meters (outside unit) dB.......... 39 ................ 39 ................ 40 ................ 41 .................40 .....................40
Weight of hydraulic module (empty/full of water) kg.... 52,5/77,5 ......52,5/77,5 .....52,5/77,5 .....52,5/77,5 ..... 52,5/77,5 ....52,5/77,5
Water capacity of the hydraulic module l.......... 25 ................ 25 ................ 25 ................ 25 .................25 .....................25
Heating system operating limits
Outdoor temperature mini/maxi °C......-15/+24 ........-15/+24 ........ -15/+24 ........ -15/+24 ........ -15/+24 ........-15/+24
Initial max. heating water temperature
- Floor heating system °C..........45 ................ 45 ................ 45 ................ 45 .................45 .....................45
- Low temperature radiator °C..........52 ................ 52 ................ 52 ................ 52 .................52 .....................52
Flow min. heating water temperature °C...........8 .................. 8 .................. 8 .................. 8 ...................8 ........................8
Refrigeration circuit
Diameter of gas pipes inches......... 1/2 ................1/2 ...............5/8 ...............5/8 ...............5/8 ...................5/8
Diameter of uid pipes inches......... 1/4 ................1/4 ...............1/4 ...............3/8 ...............3/8 ...................3/8
Factory charge of refrigerant R410A* g........1250 ............ 1250 ............ 1700 ............ 2100 .............3350 ...............3400
Maximum operating pressure bar..........45 ................ 45 ................ 45 ................ 45 .................45 .....................45
Minimum length of pipes m...........5 .................. 5 .................. 5 .................. 5 ...................5 ........................5
Maximum length of pipes** m..........15 ................ 15 ................ 15 ................ 20 .................20 .....................20
Maximum length of pipes*** m..........20 ................ 20 ................ 30 ................ 40 .................40 .....................40
Maximum level difference*** m..........15 ................ 15 ................ 20 ................ 30 .................30 .....................30
* Refrigerant R410A (as per the standard EN 378.1)
** Factory charge of refrigerant R410A.
*** Taking into account the possible additional load of refrigeration
uid R410A (see page 22).
Installation and operating manual "1303 - EN" - 5 -
Heat pump Alfea S