Meanwell DR-30 series Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the Meanwell DR-30 series Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
SPECIFICATION
DR-30-5 DR-30-12 DR-30-15 DR-30-24
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDTIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT (Typ.)
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGHUMIDITY
WORKINGTEMP.
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
5V 12V 15V 24V
3A 2A 2A 1.5A
0~3A 0~2A 0~2A 0~1.5A
15W 24W 30W 36W
80mVp-p 120mVp-p 120mVp-p
13.5~16.5V
150mVp-p
21.6~26.4V
2.0% 1.0% 1.0% 1.0%
10.8~13.2V4.75~5.5V
1.0% 1.0% 1.0% 1.0%
1.0% 1.0% 1.0% 1.0%
100ms,30ms/230VAC100ms,30ms/115VAC atfullload
100ms/230VAC30ms/115VAC atfullload
85~264VAC120~370VDC
47~63Hz
74% 81% 82% 83%
0.88A/115VAC0.48A/230VAC
COLDSTART 15A/115VAC30A/230VAC
105~160% ratedoutputpower
Protectiontype: Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
5.75~6.75V
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
13.8~16.2V 17.25~20.25V 27.6~32.4V
-20~+60 (Refertooutputloadderatingcurve)
20~90%RHnon-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50
10~500Hz,2G10min./1cycle,periodfor60min. eachalongX, Y,Zaxes
441.5Khrsmin.MIL-HDBK-217F(25 )
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
FileName:DR-30-SPEC2005-09-13
UL60950-1, TUVEN60950-1 EN50178Approved,Designreferto
CompliancetoEN55011,EN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2,EN61204-3Heavyindustrylevel,criteria A
30WSingleOutputIndustrialDINRailPowerSupply
DR-30 se ri es
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
ENVIRONMENT
PROTECTION
SAFETY &
EMC
(Note4)
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVAC
I/P-O/P:100MOhms/500VDC
EMICONDUCTION&RADIATION
Universal AC input/Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
Isolation class
LED indicator for power on
100% full load burn-in test
3 years warranty
Features :
78*93*56mm(W*H*D)
0.27Kg;48pcs/14Kg/1.02CUFT
BlockDiagram
OutputDerating
MechanicalSpecification
FileName:DR-30-SPEC2005-09-13
-20 0 10 20 30 40 50 60 70 (VERTICAL)
20
40
60
80
100
AMBIENTTEMPERATURE( )
LOAD(%)
TerminalPin.No Assignment
PinNo. PinNo.
2
1 5,6
3,4
7
8
Assignment Assignment
+V
AC/N
AC/L
-V
LED
+V ADJ.
ADMISSIBLEDIN-RAIL:TS35/7.5OR TS35/15
93
6
5 5 5 5
5
3
4
2
37.75
1
35
78
12.2
7
8
45
68
46.5
27.4
3
47
56
46.5
CIRCUIT
DETECTION
O.L.P.
EMI
FILTER
RECTIFIERS
&
FILTER
POWER
SWITCH-
FILTER
&
RECTIFIERS
+V
-V
I/P
ING
CONTROL
O.V.P.
OutputDeratingVSInputVoltage
INPUTVOLTAGE(VAC)60Hz
85 10095 120115 160140 200180 240220 264
LOAD(%)
Ta=25
90
100
80
70
60
50
40
CaseNo.918BUnit:mm
30WSingleOutputIndustrialDINRailPowerSupply
DR-30 se ri es
/