  • Hello! I am an AI chatbot trained to assist you with the B&B Electronics MDR-40-24 Datasheet. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
SPECIFICATION
MDR-40-5 MDR-40-12 MDR-40-24 MDR-40-48
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME Note.5
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT (Typ.)
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGHUMIDITY
WORKINGTEMP.
DCOKSIGNAL
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
5V 12V 24V 48V
6A 3.33A 1.7A 0.83A
0~6A 0~3.33A 0~1.7A 0~0.83A
30W 40W 40.8W 39.8W
80mVp-p 120mVp-p 150mVp-p
24~30V
200mVp-p
48~56V
2.0% 1.0% 1.0% 1.0%
12~15V5~6V
1.0% 1.0% 1.0% 1.0%
1.0% 1.0% 1.0% 1.0%
500ms,30ms/230VAC500ms,30ms/115VAC atfullload
50ms/230VAC20ms/115VAC atfullload
85~264VAC120~370VDC
47~63Hz
78% 86% 88% 88%
1.1A/115VAC0.7A/230VAC
COLDSTART 30A/115VAC60A/230VAC
105~150% ratedoutputpower
Protectiontype: Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
6.25~7.25V
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
15.6~18V 31.2~36V 57.6~64.8V
-20~+70 (Refertooutputloadderatingcurve)
Relaycontactrating(max.):30V/1A resistive
20~90%RHnon-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50
Component: eachalongX, Y,Zaxes;Mounting:CompliancetoIEC60068-2-610~500Hz,2G10min./1cycle,periodfor60min.
301.7Khrsmin.MIL-HDBK-217F(25 )
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
FileName:MDR-40-SPEC2007-07-09
UL508, TUVEN60950-1approved,NECclass2/LPScompliant(12V,24V,48Vonly)
CompliancetoEN55011,EN55022(CISPR22),EN61204-3ClassB
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2,EN61204-3,heavyindustrylevel,criteria A
40WSingleOutputIndustrialDINRailPowerSupply
MDR-40 se ri es
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
ENVIRONMENT
PROTECTION
SAFETY &
FUNCTION
EMC
(Note4)
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
EMICONDUCTION&RADIATION
Universal AC input/Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
NEC class 2 / LPS compliant (12V,24V,48V only)
LED indicator for power on
DC OK relay contact
No load power consumption<0.75W
100% full load burn-in test
3 years warranty
Features :
40*90*100mm(W*H*D)
0.3Kg;42pcs/13.6Kg/0.82CUFT
LEAKAGECURRENT
<1mA /240VAC
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:>100MOhms/500VDC25 70%RH
BlockDiagram
DCOKRelayContact
MechanicalSpecification
FileName:MDR-40-SPEC2007-07-09
-20 0 10 20 30 45 55 60 70 (VERTICAL)
20
40
60
80
100
AMBIENTTEMPERATURE( )
LOAD(%)
CIRCUIT
DETECTION
O.L.P.
EMI
FILTER
ContactClose Whentheoutputvoltagereachestheadjustedoutputvoltage.
Whentheoutputvoltagedropbelow90%outputvoltage.
30V/1A resistiveload
ContactOpen
ContactRatings(max.)
RECTIFIERS
&
FILTER
POWER
SWITCHING
FILTER
&
RECTIFIERS
+V
DCOK
-V
I/P
CONTROL
O.V.P.
O.C.P.
OutputDeratingVSInputVoltage
INPUTVOLTAGE(VAC)60Hz
85 10095 120115 160140 200180 240220 264
LOAD(%)
Ta=25
90
100
80
70
60
50
40
DeratingCurve
+
InstallDINrail TS35/7.5or TS35/15
35
+V +V
90
40
-V -V
N L
DCOK
+V ADJ
5 5 5 5 5
7.5
7.5
100
fosc:60KHz
DCOK
CaseNo.962A Unit:mm
40WSingleOutputIndustrialDINRailPowerSupply
MDR-40 se ri es
/