Hager 46CE Installation guide

Type
Installation guide

Hager 46CE is a cylinder escutcheon that provides key-operated locking and unlocking of lever handles. It requires a mortise cylinder and an “L” cam with a radius of 0.637” (16mm), both sold separately. The 46CE is suitable for use with single or double door panic exit hardware and is compatible with 4920, 4950, 4920F, and 4952 strike options. It features a square handing pin for easy adjustment of the lever handle direction and comes with a 5/8” collar for a secure fit. The 46CE is designed to enhance the security and functionality of your panic exit hardware.

Hager 46CE is a cylinder escutcheon that provides key-operated locking and unlocking of lever handles. It requires a mortise cylinder and an “L” cam with a radius of 0.637” (16mm), both sold separately. The 46CE is suitable for use with single or double door panic exit hardware and is compatible with 4920, 4950, 4920F, and 4952 strike options. It features a square handing pin for easy adjustment of the lever handle direction and comes with a 5/8” collar for a secure fit. The 46CE is designed to enhance the security and functionality of your panic exit hardware.

4600 Series Narrow Stile Trim
Installation Instructions
I-ED01164
Rev 3, Rev Date: 8/4/2017 27390048 Page 1 of 5
Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.hagerco.com
OVERVIEW
46CE
Cylinder Escutcheon
Key Locks & Unlocks Levers
Requires a mortise cylinder (3902)
and “L” Cam (3976)
with radius 0.637” (16mm). Both
sold separately.
46NK
Night Lever
Lever Operable When Key Is Turned. Key Removable Only
When Locked
Requires a mortise cylinder (3902) and “L” Cam (3976)
with radius 0.637” (16mm). Both sold separately.
46BE
Blank Escutcheon
Always Operable
46DT
Dummy
Pull When Exit Device Is Dogged
46NL
Night Latch
Key Retracts Latchbolt
Requires a RIM cylinder (3901) and
extra long
tailpiece (2-639-7058).
Both sold separately.
Handing Pin
Mounting Post
(2 places)
Cylinder Cam
Cylinder Nut
Adjustable
Tailpiece
DEVICES COVERED IN THIS DOCUMENT:
46CE Cylinder Escutcheon Key locks and
unlocks lever
46BE Blank Escutcheon Always operable
46NK Night Lever (09 Function) Lever operable
when key is turned. Key removable only when
locked.
Cylinder Collar
Mortise Cylinder
Lever Handle
(46CE Cylinder
Escutcheon Shown)
4600 Series Narrow Stile Trim
Installation Instructions
I-ED01164
Rev 3, Rev Date: 8/4/2017 27390048 Page 2 of 5
Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.hagerco.com
APPLICATIONS
4950 BLADE STOP STRIKE SINGLE DOOR
4920 STANDARD STRIKE SINGLE DOOR
4920 STANDARD STRIKE AND MULLION
4952 SEMI-FLUSH STRIKE AND MULLION
4920 Standard Strike Application
Single or Double Door Panic Exit Hardware
(4912 strike available for fire-rated applications)
4952 Semi-Flush Strike Application
Single or Double Door Panic Exit Hardware
TOOLS REQUIRED
4950 Blade Stop Strike Application
Single Door Panic Exit Hardware
4920 Standard Strike Application
Single or Double Door Panic Exit Hardware
(4920F Strike Available for Fire Rated Applications)
4600 Series Narrow Stile Trim
Installation Instructions
I-ED01164
Rev 3, Rev Date: 8/4/2017 27390048 Page 3 of 5
Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.hagerco.com
1. SET TRIM HANDING
A. Rotate lever handle to the right or left direction to match the desired door handing.
B. Align the handle for the desired door handing position and then insert the square handing pin into the trim
escutcheon as shown below.
2. INSTALL MORTISE CYLINDER (for CE and NK trim only)
A. Install mortise cylinder into collar and
escutcheon trim.
B. From the back of the trim escutcheon
screw cylinder nut onto mortise cylinder
until secure.
Test Installation (CE trim only)
Insert the key and rotate counterclockwise.
Turn the lever handle and observe the
tailpiece. It should be unlocked and the
tailpiece will rotate. Rotate the key clockwise
to lock the trim. Verify that the tailpiece does
not rotate when the handle is turned.
Test Installation (NK trim only)
Insert the key and rotate counterclockwise.
While keeping the key rotated, turn the lever
Handle and observe the tailpiece to see if it
has rotated. The handle should cause the
tailpiece to turn only when the key remains
turned. Release the key. Rotate the lever
handle and confirm that the tailpiece is not
turning.
Left Hand Reverse (LHR) show
Square Handing Pin
Cylinder Nut
5/8” Collar
46CE Cylinder
Escutcheon
Mortise Cylinder
Part # 3902 with
3976 Cam
R 0.637” (16mm)
(Ordered separately)
4600 Series Narrow Stile Trim
Installation Instructions
I-ED01164
Rev 3, Rev Date: 8/4/2017 27390048 Page 4 of 5
Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.hagerco.com
3. INSTALL NIGHT LATCH RIM CYLINDER (for NL trim only)
A. Replace standard length tailpiece with extra-long tailpiece (2-3/8”).
B. Install rim cylinder into collar and escutcheon trim.
C. Install cylinder mounting bracket from back side of escutcheon trim as shown below.
D. Adjust break-off screws to eliminate excess length and secure rim cylinder.
E. Insert key and rotate. Observe the back of the trim and verify that the tailpiece rotates.
4. DRILL MOUNTING HOLES FOR ESCUTCHEON TRIM
A. Mark horizontal centerline by matching it to exit device centerline,
which can be found on the push side of the door.
B. Mark vertical centerline by matching it to exit device centerline,
which can be found on the push side of the door. Refer to Applications
section on page 2 to determine the location of the vertical centerline.
C. Apply template to door using centerlines.
D. Mark and drill holes as shown below.
i. Note that the mounting holes are the same for all functions but
the tailpiece clearance hole is different depending on function.
Note: Available templates include T-ED01194 4600 Trim Template (BE,
CE,DT) and T-ED01195 46NL Trim Template
#12-24 Break-off screws
Cylinder Mounting Bracket
46NL
Night Latch
5/8” Collar
RIM Cylinder
Part No. 3901
& Extra Long Tailpiece
Part # 2-639-7058
(Both Sold Separately)
Door Stile
(Pull Side)
Frame
Note B
Note C
Note A
Note A
Notes:
A. Trim centerline corresponds to exit device centerline.
B. Trim mounting clearance holes (2 places):
i. Drill ø 1/2” [13] holes on pull side.
ii. Drill ø 5/16” [8] holes on push side.
C. Trim tailpiece clearance hole:
i. For CE, NK and BE functions:
1. Drill ø 3/4” [19] hole on pull side.
2. Drill ø 1/2” [13] hole on pull side.
ii. For NL function, drill ø 1/2” [13] thru hole.
iii. Not required for DT function.
4600 Series Narrow Stile Trim
Installation Instructions
I-ED01164
Rev 3, Rev Date: 8/4/2017 27390048 Page 5 of 5
Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.hagerco.com
5. ADJUST TELESCOPING ACTUATING SHAFT (for BE, CE and NK trim only)
A. The telescoping actuating shaft is preset at the factory for a 1-3/4” thick door. For thicker door applications
follow these steps:
i. Remove the small screw on the side of the actuating shaft and keep it handy for the next step.
ii. Use the chart below to choose the appropriate setting for your door application. For other door/shim
kit thicknesses, use the closest larger size.
iii. Slide the center shaft out until it lines up properly with the setting you chose in the last step.
iv. Replace the screw and secure.
v. Check for proper engagement with the exit device in the next step.
INSTALL ESCUTCHEON TRIM
A. Insert trim mounting
posts and actuating shaft
through door.
B. Mate trim actuating
shaft with cam on
back of exit device.
C. Secure from push
side of door with
provided ¼”-20
machine screws.
D. Test installation by
rotating lever
handle or key to
verify trim functions
properly.
4600 Narrow Stile
Exit Device
Adjust Shaft Length
Telescoping Actuating Shaft
Remove Screw
Preset Door Thickness Positions
For Telescoping Actuating Shaft
3”
2-1/2”
2”
2-1/4”
1-3/4”
(Factory preset
46CE Cylinder Escutcheon
Door Stile
¼”-20 Mounting Screws
Replace Screw
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Hager 46CE Installation guide

Type
Installation guide

Hager 46CE is a cylinder escutcheon that provides key-operated locking and unlocking of lever handles. It requires a mortise cylinder and an “L” cam with a radius of 0.637” (16mm), both sold separately. The 46CE is suitable for use with single or double door panic exit hardware and is compatible with 4920, 4950, 4920F, and 4952 strike options. It features a square handing pin for easy adjustment of the lever handle direction and comes with a 5/8” collar for a secure fit. The 46CE is designed to enhance the security and functionality of your panic exit hardware.

Ask a question and I''ll find the answer in the document