Bticino 3485 is a powerful and versatile burglar alarm and telephone dialer designed to provide comprehensive security for your home or business. With its advanced features, it offers reliable protection and peace of mind.

Bticino 3485 is a powerful and versatile burglar alarm and telephone dialer designed to provide comprehensive security for your home or business. With its advanced features, it offers reliable protection and peace of mind.

06/08 - CT
Version 1.0
TiSecurityPolyx user manual
Software for the conguration
of the 3485 Burglar Alarm Unit
3
CONTENTS
1. Hardware and Software requirements 4
2. Installation
4
3. Basic concepts
8
3.1 Menus and general buttons for selecting functions
4. Importing data from an existing project 11
4.1 Importing voice messages
4.2 Importing conguration data
5. Connecting to the Unit 13
6. Exchanging data with the Unit 1
5
7. Parameters 1
6
7.1 Work area
7.1.1 Data input procedure
7.2 Exchanging conguration parameters with the Unit
7.2.1 Receiving conguration parameters
7.2.2 Sending conguration parameters
7.2.3 Receiving the history of events
7.3 Conguration of the Burglar alarm section
7.3.1 Zones
7.3.2 Automations
7.3.3 User Preferences
7.3.4 Installer Preferences
7.3.5 Key management
7.3.6 Scenarios
7.4 Conguration of the Dialling device section
7.4.1 Telephone number directory
7.4.2 Setting up calls
7.4.3 Telephone functions
7.4.4 Block (Lock)
7.4.5 Protocol - MyHome Portal
7.4.6 Protocol - ADEMCO
7.4.7 Line test
7.4.8 Telephone commands
8. Messages 50
8.1 Work area
8.2 Exchanging voice messages with the Unit
8.2.1 Sending voice messages
8.2.2 Listening to messages from the Unit loudspeaker
8.2.3 Receiving voice messages
8.3 Voice message commands
8.3.1 Importing an audio le
8.3.2 Emitting a voice message
8.3.3 Recording a voice message
8.3.4 Retrieving voice messages
9. Update Firmware 54
4
TiSecurityPolyx
Hardware requirements
• Personal Computer with Pentium processor >400 MHz
• 256 MB RAM
• SVGA graphics card with resolution 800x600
• CD-ROM unit
• Mouse
Software requirements
Windows 2000, XP or Vista; Internet Explorer 6.0 or higher.
Space used on hard-disk
• 91 Mbyte.
1. Hardware
and Software
requirements
Please note: The TiSecurity-
Polyx program is the essential
tool for the conguration of
the 3485 Burglar alarm Unit.
The content of this program
is under the exclusive rights
of Bticino SpA.
Follow this procedure to install the TiSecurityPolyx program:
1. Insert the CD-ROM in the drive;
2. After displaying the main page in the web format, select “Install TiSecurityPolyx”;
3. The installation program will now copy the system les necessary for the execution of the
TiSecurityPolyx program.
2. Installation
> Select the installation kit language
> Click the
Ok button
5
The following screen will appear
> Click the Next button
> Click Next to install the program in the default directory
“C:\Programmi\BTicino\TiSecurityPolyx_0100”
> Click Browse to select the required path
Or
The following screen will appear
6
TiSecurityPolyx
The following screen will appear
> Click Next if you are ready to install TiSecurityPolyx
Or
> Click
Back to return to the previous screen
The following screen will appear
> Select the TiSecurityPolyx interface language (The language can also be changed when using
the application, without the need for reinstallation).
> Click the
Next button
7
The installation of the program will now begin.
Depending on the operating system setup in use, it may be necessary to restart the system.
> Click Finish to end the process
8
TiSecurityPolyx
3. Basic concepts
The TiSecurityPolyx software is used for the conguration of the 3485 Burglar alarm Unit which com-
bine the burglar alarm and telephone dialling device into one device.
After opening the program, the following screen will appear:
Please note: For proper
functioning of the software,
the 3485 Burglar Alarm Unit
must be installed according
to the indications specied
in the installation manual
supplied with the device.
Depending on the technician and users needs, it is possible to begin with a new conguration or
change an existing conguration.
In this manual the various screens will refer to the second mode.
Creating a new conguration:
Start TiSecurityPolyx
Execute and save the conguration
Send data to the Unit
Modifying an existing conguration:
Execute the system auto-learning function from the Unit
Receive data from the Unit with TiSecurityPolyx
Edit, if required
Send data to the Unit
In order to perform a proper conguration, it is necessary to execute the system auto-learning
function before connecting the Unit to the PC.
Using the Firmware Update function, with the TiSecurityPolyx it is also possible to update the per-
manent Control Unit Software, using new issues published by BTicino.
9
3.1 Menus and general buttons for selecting functions
The main functions that can be executed with TiSecurityPolyx can be selected by using the icons
in the toolbar or by opening drop-down menus, thus selecting the various options. Quick keys can
also be used for some functions, like:
to create a new project, it is possible to select New from the File drop-down menu, from the toolbar
and from the keyboard by using the keys Ctrl +N.
The followings functions are included in the toolbar:
Create a new
project
Save the current
project
Opens the Para-
meters section
Executes connection to
the Unit
Opens an existing
project
Opens the Voice
message section
Selects the serial port of
the PC to which the Unit is
connected
Executes connection to
the Bticino website
Select the interface
language
The followings functions are included in the drop-down menus:
“File menu
New creates a new project
Open opens an existing project
Save saves the current project
Save as (with name) saves the project after requesting a le name
Export conguration exports the project thus creating a le with
extension .csv which can be imported into
Microsoft Excel®.
Exit exits the program
“Edit” menu
Import messages from project imports all voice messages from an existing
project
Import conguration data from project
imports all conguration data from an existing
project
Load pre-dened audio messages retrieves voice messages set up for the Unit
Select all messages selects all messages of the project
Select all xed messages selects all xed messages of the project
10
TiSecurityPolyx
“?” menu
About... displays information on the TiSecurityPolyx program
Supported versions displays information on TiSecurityPolyx, hardware and
software versions of the Unit
The status bar shows the following information:
Current data
Current time
Loaded project le
“Language” menu
select the TiSecurityPolyx interface language
Type of Unit
Tools” menu
Parameters opens the Parameters section
Messages opens the Messages section
Receive conguration receives the conguration from the Unit, it is active only
when connecting to the Unit
Send conguration sends the conguration to the Unit, it is active only when
connecting to the Unit
Update Firmware starts the Unit rmware update procedure
Connection to Unit enables connection between the PC and the Unit
11
> Select Import messages from project from the Edit menu
> Select the project le (. jai) from where you want to import the messages
> Click the Open button
When the procedure has been completed, the imported messages will appear
4.1 Importing voice messages
To import voice messages from a project le:
The following screen will appear
4. Importing data
from an existing
project
It is possible to import data (conguration parameters and voice messages) from a previously saved
project le.
Please note: it is recommend
to save the current congu-
ration le of before starting
the procedure.
12
TiSecurityPolyx
Please note: it is recommend
to save the current congu-
ration le of before starting
the procedure.
> Select Import conguration data from project from the Edit menu
> Select the project le (. jai) from where you want to import the conguration
> Click the Open button
When the procedure has been completed, the new conguration will appear
4.2 Importing conguration data
To import a previously saved conguration:
The following screen will appear
13
> Select Connection to Unit from the Tools menu
The following message will appear
5. Connecting to the
Unit
To access some functions (e.g. Receive conguration, Send messages, etc.) there must be a con-
nection between the PC where TiSecurityPolyx is installed and the Unit, following the operation
described below.
> From the Port menu, select the serial port address of the PC you want to connect the Unit to
(COM1, COM2, etc.).
> Execute the required operations and then click OK
Select the maintenance menu
of the Unit and start the auto-
learning function
Slide switch
b
a
b
ON
BUS
ART.3485
T1
_
OFF
ON
BUS
ART.3485
T1
_
OFF
Item 335919
Item 3559
Flip the slide switch to o
Click the OK button
Connect the programming cable to a
serial port or USB of the PC and to the
6–way connector of the Unit
14
TiSecurityPolyx
When connecting to the Unit, a comparison will be made between the conguration of the Unit
which reects the real system, and the conguration of the current project.
If the congurations are dierent, the following warning message it will appear:
> Click YES to display the details of the dierences found
The data can be exported into a le with extension .csv, which can be imported in Microsoft
Excel.
At this stage, by clicking the Details button, it is possible to display the list of communication acti-
vities between the personal computer and the unit.
15
6. Exchanging data
with the Unit
When the connection to the Unit has been activated, it will be possible to:
Send/receive conguration parameters
Send/receive voice messages
Receive the history of events from the unit
Refer to paragraphs “7.2 Exchanging conguration parameters with the Unit” and “8.2 Exchanging
voice messages with the Unit” to carry out these functions.
At the end of the procedure the Connection button will change into Disconnection.
It is now possible to swap data with the Unit
Click Disconnection to stop connection.
The following message will appear
> Disconnect the programming cable from the Unit
> Click the OK button
> Click YES to load the conguration of the system in the Unit
> Click NO to keep the current project unchanged
However, there will be a connection to the Unit.
> The following message will appear if click QUIT
16
TiSecurityPolyx
7.1 Work area
7. Parameters
In this section it is possible to execute the Unit parameters congurations.
In this section all typical parameters for the conguration of the Unit are displayed, represented
hierarchically with a tree structure on the left side.
On the right side, a specic template for inputting data and, if the connection is active, for commu-
nicating with the Unit can be displayed by selecting each element of the hierarchic structure.
17
Data input template
Receives conguration
from the Unit
Send conguration to the
Unit
Receives the history of
events from the Unit
Fixed zone
Data input
zone
Help zone
Communication bar with
the Unit
The upper bar includes the commands for communication with the control unit (only active when
the connection with established PC); the central section is for data entry, and will vary depending
of the selected parameter; the lower bar displays the instructions to guide the user through the
data entry procedure.
7.1.1 Data input procedure
Inputting by typing in data:
> Click the data input zone
> The text, if any, will be edited (e.g. Input)
> Type in new data
Inputting data with the drop-down menu:
> Click the data input zone; the button will appear
> A drop-down menu will appear after clicking the button
> Select any data available
Displays information
18
TiSecurityPolyx
Inputting data with the sliding menu:
> Click the data input zone; the button will appear
> Use the button to move through the available data
Inputting with an independent window:
> Click the data input zone; the button will appear
> An independent window will appear after clicking the button
> Enter the data
> Click OK to close the window
19
7.2 Exchanging conguration parameters with the Unit
7.2.1 Receiving conguration parameters
This function allows you to receive the conguration parameters from the Unit.
> Execute the Connection to Unit procedure
> Click Receive button
The following screen will appear
> Click the Yes button
When the procedure has been completed, the Unit conguration parameters will be available in
the relative section for future verications or changes.
To activate a new conguration the sending procedure, described in the following paragraph, must
be completed.
> Click the Yes button
If the current project has not been saved, a reminder appears on the screen.
20
TiSecurityPolyx
7.2.2 Sending conguration parameters
This function allows you to send the conguration parameters to the Unit.
> Execute the Connection to Unit procedure
> Click Send button
The following screen will appear
> Click the Yes button
When sending the parameters, a comparison will be made between the conguration of the Unit
and the conguration of the current project, if these are dierent the following warning message
will appear:
> Click the Yes button
If the current project has not been saved, a reminder appears on the screen.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58

Bticino 3485 User manual

Category
Software
Type
User manual

Bticino 3485 is a powerful and versatile burglar alarm and telephone dialer designed to provide comprehensive security for your home or business. With its advanced features, it offers reliable protection and peace of mind.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI