EuroLite LED IP FL-12 Floodlight MD User manual

Category
Floodlights
Type
User manual
©
Copyright
Nachdruck verboten!
Reproduction prohibited!
Für weiteren Gebrauch aufbewahren!
Keep this manual for future needs!
BEDIENUNGSANLEITUNG
USER MANUAL
LED IP FL-6 /IP FL-10/
IP FL-12/IP FL-30/
IP FL-50
Floodlight MD
00071238.DOC, Version 1.1
2/14
MULTI-LANGUAGE-INSTRUCTIONS
Inhaltsverzeichnis
Table of contents
EINFÜHRUNG................................................................................................................................................... 3
Features ......................................................................................................................................................... 3
SICHERHEITSHINWEISE................................................................................................................................. 4
BESTIMMUNGSGEMÄSSE VERWENDUNG .................................................................................................. 5
INSTALLATION ................................................................................................................................................ 6
Befestigung .................................................................................................................................................... 6
Anschluss ans Netz........................................................................................................................................ 6
BEDIENUNG ..................................................................................................................................................... 7
REINIGUNG UND WARTUNG.......................................................................................................................... 7
TECHNISCHE DATEN ...................................................................................................................................... 8
INTRODUCTION ............................................................................................................................................... 9
Features ......................................................................................................................................................... 9
SAFETY INSTRUCTIONS............................................................................................................................... 10
OPERATING DETERMINATIONS.................................................................................................................. 11
INSTALLATION .............................................................................................................................................. 12
Attachment ................................................................................................................................................... 12
Connection with the mains........................................................................................................................... 12
OPERATION.................................................................................................................................................... 13
CLEANING AND MAINTENANCE ................................................................................................................. 13
TECHNICAL SPECIFICATIONS..................................................................................................................... 14
Diese Bedienungsanleitung gilt für die Artikelnummern: / This user manual is valid for the article numbers:
51914542, 51914547, 51914552, 51914557, 51914582, 51914587, 51914650, 51914652, 51914655,
51914657,
Das neueste Update dieser Bedienungsanleitung finden Sie im Internet unter:
You can find the latest update of this user manual in the Internet under:
www.eurolite.de
00071238.DOC, Version 1.1
9/14
USER MANUAL
LED IP FL-Floodlight MD
For your own safety, please read this user manual carefully before you initially start-up.
Every person involved with the installation, operation and maintenance of this device has to
- be qualified
- follow the instructions of this manual
- consider this manual to be part of the total product
- keep this manual for the entire service life of the product
- pass this manual on to every further owner or user of the product
- download the latest version of the user manual from the Internet
INTRODUCTION
Thank you for having chosen a EUROLITE LED IP FL-Floodlight MD. If you follow the instructions given in
this manual, we are sure that you will enjoy this device for a long period of time.
Unpack your LED IP FL-Floodlight MD.
Features
Brilliant floodlight with LED technology and motion detector
Add highlights to your house and garden
Ideal LED luminary for outdoor use
The weather-resistant housing also allows operation during bad weather
For permanent installation, mounting bracket included
Extremely compact housing in an appealing design
Particularly bright illuminating power of the LEDs
2 color temperatures of the white LEDs available: 6400 K or 3000 K
Beam reflection angle of 120°
Motion detector setting options: daylight sensor, illumination duration, motion detection sensor (not for
article 51914650 and 51914652)
Ready for connection via power cord with safety-plug
00071238.DOC, Version 1.1
10/14
SAFETY INSTRUCTIONS
CAUTION!
Becarefulwithyouroperations.Withadangerousvoltageyoucansufferadangerous
electricshockwhentouchingthewires!
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to
ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning
notes written in this user manual.
Important:
Damages caused by the disregard of this user manual are not subject to warranty. The dealer
will not accept liability for any resulting defects or problems.
If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it
on immediately. The arising condensation water might damage your device. Leave the device switched off
until it has reached room temperature.
Please make sure that there are no obvious transport damages. Should you notice any damages on the A/C
connection cable or on the casing, do not take the device into operation and immediately consult your local
dealer.
This device falls under protection-class I. The power plug must only be plugged into a protection class I
outlet. The voltage and frequency must exactly be the same as stated on the device. Wrong voltages or
power outlets can lead to the destruction of the device and to mortal electrical shock.
Always plug in the power plug last. The power plug must always be inserted without force. Make sure that
the plug is tightly connected with the outlet.
Never let the power-cord come into contact with other cables! Handle the power-cord and all connections
with the mains with particular caution! Never touch them with wet hands, as this could lead to mortal
electrical shock.
Never modify, bend, strain mechanically, put pressure on, pull or heat up the power cord. Never operate next
to sources of heat or cold. Disregard can lead to power cord damages, fire or mortal electrical shock.
The cable insert or the female part in the device must never be strained. There must always be sufficient
cable to the device. Otherwise, the cable may be damaged which may lead to mortal damage.
Make sure that the power-cord is never crimped or damaged by sharp edges. Check the device and the
power-cord from time to time.
If extension cords are used, make sure that the core diameter is sufficient for the required power
consumption of the device. All warnings concerning the power cords are also valid for possible extension
cords.
Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the
power-cord by the plug. Never pull out the plug by tugging the power-cord. Otherwise, the cable or plug can
be damaged leading to mortal electrical shock. If the power plug or the power switch is not accessible, the
device must be disconnected via the mains.
If the power plug or the device is dusty, the device must be taken out of operation, disconnected and then be
cleaned with a dry cloth. Dust can reduce the insulation which may lead to mortal electrical shock. More
severe dirt in and at the device should only be removed by a specialist.
There must never enter any liquid into power outlets, extension cords or any holes in the housing of the
device. If you suppose that also a minimal amount of liquid may have entered the device, it must immediately
be disconnected. This is also valid, if the device was exposed to high humidity. Also if the device is still
running, the device must be checked by a specialist if the liquid has reduced any insulation. Reduced
insulation can cause mortal electrical shock.
00071238.DOC, Version 1.1
11/14
There must never be any objects entering into the device. This is especially valid for metal parts. If any metal
p
arts like staples or coarse metal chips enter into the device, the device must be taken out of operation and
disconnected immediately. Malfunction or short-circuits caused by metal parts may cause mortal injuries.
K
eep away children and amateurs!
Never operate the device without protective shield!
Replace any cracked protective shield.
OPERATING DETERMINATIONS
This device is a fixed general purpose luminaire. This product is only allowed to be operated with an
alternating voltage of 230 V, 50 Hz and was designed for indoor use only.
This device is splash-proof (IP X4) and therefore qualified for indoor and outdoor use. In order to maintain
this protection grade after opening the housing, any rubber sealings must be examined for damages and
always be correctly installed.
For outdoor use, the installer must always make sure to connect a rubber cable H05RN-F or HO5RR-F. For
installations in the ground, an underground power cable NYY must be used!
All valid instructions concerning the installation of cables outdoors or in the ground must be adhered!
The ambient temperature must always be between -5° C and +45° C. Keep away from direct insulation
(particularly in cars) and heaters.
The maximum relative humidity is 100 % with an ambient temperature of 25° C.
This device must only be operated in an altitude between -20 and 2000 m over NN.
Do not shake the device. Avoid brute force when installing or operating the device.
When choosing the installation-spot, please make sure that the device is not exposed to extreme heat,
moisture or dust. There should not be any cables lying around. You endanger your own and the safety of
others!
The symbol
---m
determines the minimum distance from lighted objects. The minimum distance
between light-output and the illuminated surface must be more than 0.1 meters.
Make sure that the area below the installation place is blocked when rigging, derigging or servicing the
fixture.
Operate the device only after having become familiarized with its functions. Do not permit operation by
persons not qualified for operating the device. Most damages are the result of unprofessional operation!
Please use the original packaging if the device is to be transported.
Please consider that unauthorized modifications on the device are forbidden due to safety reasons!
If this device will be operated in any way different to the one described in this manual, the product may suffer
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, crash etc.
00071238.DOC, Version 1.1
12/14
INSTALLATION
Attachment
Permanent installation is recommended!
Before attaching the device, make sure that the installation area can hold a minimum point load of 10 times
the device's weight.
T
he device must only be installed absolutely planar at a vibration-free, oscillation-free and fire-resistant
location. Make sure that the device is installed absolutely planar by using a water-level.
The device must be installed out of the reach of people.
The device must always be installed via all fixation holes. Do only use appropriate screws and make sure
that the screws are properly connected with the ground.
The durability of the installation depends very much on the material used at the installation area (building
material) such as wood, concrete, gas concrete, brick etc. This is why the fixing material must be chosen to
suit the wall material. Always ask a specialist for the correct plug/screw combination indicating the maximum
load and the building material.
Procedure:
Step 1: The holes for the installation are on the mounting bracket.
Step 2: Pay attention to the correct mounting position for the floodlight. Only mount it with the motion
detector pointing downwards.
Step 3: The ideal installation height is between 2 and 4 meters depending where it is installed and the
ambient conditions (layout of access routes to be monitored, etc.)
Step 4: Hold the mounting bracket onto the location where the device is to be installed.
Step 5: Mark the boreholes with a pen or a suitable tool.
Step 6: Drill the holes.
Step 7: Hold the mounting bracket in the desired position and fix it.
Step 8: Adjust the desired inclination-angle via the mounting-bracket and tighten the fixation screws.
DANGERTOLIFE!
Beforetakingintooperationforthefirsttime,theinstallationhastobeapprovedbyanexpert!
Connection with the mains
Connect the device to the mains with the power plug. The occupation of the connection cables is as follows:
Cable Pin International
Brown Live L
Blue Neutral N
Yellow/Green Earth
Attention! The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
00071238.DOC, Version 1.1
13/14
OPERATION
These instructions are for all items except for article 51914650 and 51914652:
Adjusting the sensor sensitivity with SENS: The more the control is turned to the right, the more
sensitive is the reaction of the motion detector; i.e. it responds more quickly to slight temperature
changes in the detection area. If you set the sensitivity too high, even small animals or the motion of
leaves (on bushes or trees) may activate the motion detector, unintentionally activating the lamp.
For all items:
Adjusting the illumination duration after detection with TIME: Using this control, you can set the
duration for the luminary’s on-time. Turning the control counter clockwise lengthens the on-time, turning
clockwise shortens it. The on-time can be adjusted from 12 seconds to 600 seconds.
Adjusting the brightness sensitivity with DAYLIGHT: With this control knob, the brightness sensitivity can
be set, at which the motion detector is activated. The further the knob is turned clockwise (towards the
„moon“ symbol), the later this will be. If the motion detector is to be active while it is still light, turn the
knob anti-clockwise (towards the „sun“ symbol).
After you connected the device to the mains, the EUROLITE LED IP FL-Floodlight MD starts running.
CLEANING AND MAINTENANCE
Disconnectfrommainsbeforestartingmaintenanceoperation!
DANGERTOLIFE!
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no serviceable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers only
in order to avoid hazards.
Should you have further questions, please contact your dealer.
00071238.DOC, Version 1.1
14/14
TECHNICAL SPECIFICATIONS
Version: 51914650/51914652 51914655/51914657 51914542/51914547
Power supply: 230 V AC, 50 Hz ~ 230 V AC, 50 Hz ~ 230 V AC, 50 Hz ~
Power consumption: 10 W/22 VA 16 W/30 VA 11 W/23 VA
Protection grade: IP 44 IP 44 IP 44
M
aximum ambient temperature T
a
:
45° C 45° C 45° C
Max. housing temperature T
C
(steady state):
60° C 60° C 60° C
Minimum distance from flammable surfaces: 0.50 m 0.50 m 0,50 m
Minimum distance to lighted object: 0.10 m 0.10 m 0,10 m
LED type: 1 W 1 W 10 W
Number of LEDs: 6 12 1
LED beam angle: 120° 120° 120°
Range: approx: 8 m approx: 10 m ca. 7 m
Dimensions (LxWxH): 112 x 145 x 220 mm 123 x 207 x 280 mm 114 x 90 x 230 mm
Weight: 1 kg 1.4 kg 0.77 kg
Version: 51914552/51914557 51914582/51914587
Power supply: 230 V AC, 50 Hz ~ 230 V AC, 50 Hz ~
Power consumption: 33 W/53 VA 54 W/62 VA
Protection grade: IP 44 IP 44
Maximum ambient temperature T
a
:
45° C 45° C
Max. housing temperature T
C
(steady state):
60° C 60° C
Minimum distance from flammable surfaces: 0,50 m 0,50 m
Minimum distance to lighted object: 0,10 m 0,10 m
LED type: 30 W 50 W
Number of LEDs: 1 1
LED beam angle: 120° 120°
Range: ca. 7 m ca. 10 m
Dimensions (LxWxH): 130 x 223 x 320 mm 140 x 284 x 314 mm
Weight: 2.2 kg 3.1 kg
Please note: Every information is subject to change without prior notice. 25.09.2012 ©
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

EuroLite LED IP FL-12 Floodlight MD User manual

Category
Floodlights
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI