JT910SASS - GE Profile Performance
™
30" Single Wall Oven
Specification Revised 8/99
Note: Oven is rated for use only under the
following cooktops:
• GE 30" and 36" electric coil and
CleanDesign cooktops (Excluding Induction)
• GE 30" and 36" gas standard and sealed
burner cooktops
Note: Gas or electric cooktops may be installed
over this oven. See cooktop installation
instructions for cutout size. See label on back
of oven for approved cooktop models.
Installation Information: Before installing,
consult installation instructions [Pub.
No. 31-10125] packed with product for
current dimensional data and for alternate
installation options.
Single Oven Wall-Mount or Cabinet Installation
Dimensions (in inches)
Optional Undercounter Installation
with 36" Gas Cooktop (in inches)
Power cord
for counter unit
Junction box
for oven
Junction box in
adjacent cabinet
for counter unit
hook-up
2 (two) 90°elbows &
sufficient pipe to
connect in adjacent
cabinet
Right cabinet side
3/4" Support
Shut-off
valve
Pressure
regulator
1/2" Black
iron pipe
Union
Conduit
30" Built-in
oven
3-1/2" MIN.
Free space
4" To 4-1/2"
3-1/4
22
19-1/16" Cutout depth
Side View
Note: These ovens are
not
approved for stackable or
side-by-side installations.
Most 30" Wall Cabinets can be used with this unit.
28-1/2'' MIN.
28-5/8'' MAX.
30
28-1/4
30
Recommended
cutout location
32-1/2"
from floor
21
Junction
box
location
Allow minimum of 21'' for clearance
to adjacent corners, drawers, walls, or etc.
A=Allow 1" overlap of oven over top and bottom edges of cutout.
B=Allow 11/16"-3/4" for overlap of oven over side edges of cutout.
Conduit
(48" long)
5
27-1/4'' MIN.
27-5/16'' MAX.
Cutout height
A
B
23-1/2'' MIN.
Cutout depth
22'' MIN.
Cut Opening
in Solid
Bottom
10
Note: If a solid
bottom is used
instead of the
runners, a 6" x 10"
rectangle must be
cut out of the
bottom for optimum
performance
and proper air
circulation.
6
6
(Must Support 275 lbs.)
For answers to your Monogram,
®
GE Profile Performance Series,
™
GE Profile
™
or GE appliance questions, call
GE Answer Center
®
service, 800.626.2000.
Listed by
Underwriters
Laboratories
Must Support 200 lbs.
KW Rating
240V 3.6
208V 2.7
Breaker Size
20 Amps
†
†
Note: Check local codes for required
breaker size.