Invacare IH6300ADH Owner's Operator And Maintenance Manual

Type
Owner's Operator And Maintenance Manual

This manual is also suitable for

Owner’s Operation and Maintenance Manual
DEALER: This manual MUST be given to
the user of the tub.
USER:
BEFORE using this tub, read this
manual and save for future reference.
For more information regarding
Invacare products, parts, and services,
please visit www.invacare-ccg.com
Supine Bath Tub
IH6300 Fixed Height
IH6300ADH Adjustable Height
AFTER INSTALLATION, PLEASE CALL CUSTOMER SERVICE AT
1-800-668-2337 TO ARRANGE FOR AN IN-SERVICE ON THE TUB
Supine Bath Tub 2 Part No 1096926
WARNING
DO NOT USE THIS PRODUCT OR ANY AVAILABLE OPTIONAL EQUIPMENT
WITHOUT FIRST COMPLETELY READING AND UNDERSTANDING THESE
INSTRUCTIONS AND ANY ADDITIONAL INSTRUCTIONAL MATERIAL SUCH
AS OWNER’S MANUALS, SERVICE MANUALS OR INSTRUCTION SHEETS
SUPPLIED WITH THIS PRODUCT OR OPTIONAL EQUIPMENT. IF YOU ARE
UNABLE TO UNDERSTAND THE WARNINGS, CAUTIONS OR
INSTRUCTIONS, CONTACT A HEALTHCARE PROFESSIONAL, DEALER OR
TECHNICAL PERSONNEL BEFORE ATTEMPTING TO USE THIS EQUIPMENT -
OTHERWISE, INJURY OR DAMAGE MAY OCCUR.
THE INITIAL SET UP OF THIS TUB MUST BE PERFORMED BY A QUALIFIED
TECHNICIAN.
PROCEDURES OTHER THAN THOSE DESCRIBED IN THIS MANUAL MUST BE
PERFORMED BY A QUALIFIED TECHNICIAN.
ACCESSORIES WARNING
Invacare products are specifically designed and manufactured for use in conjunction
with Invacare accessories. Accessories designed by other manufacturers have not
been tested by Invacare and are not recommended for use with Invacare products.
Forfurtherinformationonthisproduct,pleasecallthefollowing:
CustomerService‐18006682337
TechnicalSupport‐18006682337
TABLE OF CONTENTS
Part No 1096926 3 Supine Bath Tub
TABLE OF CONTENTS
SPECIAL NOTES ................................................................................ 5
LABEL LOCATION ............................................................................ 6
TYPICAL PRODUCT PARAMETERS .................................................... 7
FEATURES ........................................................................................ 8
SECTION 1—GENERAL GUIDELINES ................................................... 9
Installation ....................................................................................................................................................9
Electrical .......................................................................................................................................................9
Grounding Instructions.........................................................................................................................9
Plumbing........................................................................................................................................................9
Maintenance and Inspection...................................................................................................................10
Electrical Shock Hazard......................................................................................................................10
Disinfecting.................................................................................................................................................10
Operation...................................................................................................................................................10
SECTION 2—DISINFECTING THE TUB .............................................. 12
Disinfecting the Tub Using the Closed Loop System.......................................................................12
SECTION 3—OPERATION ................................................................ 13
Overview....................................................................................................................................................13
Preparing the Tub for Use......................................................................................................................13
Operating the Tub....................................................................................................................................14
Using Water Temperature Setting ..................................................................................................14
Operating Shower/Massage Wand ..................................................................................................15
Filling the Tub .......................................................................................................................................15
Using Hydromassage ...........................................................................................................................15
Adjusting Tub Height - Model IH6300ADH ONLY.........................................................................16
Raising the Supine Tub........................................................................................................................16
Lowering the Supine Tub ...................................................................................................................16
SECTION 4—INSTALLATION ........................................................... 17
Preparing the Work Area.......................................................................................................................17
Securing the Tub.......................................................................................................................................18
Electrical Hook-up....................................................................................................................................19
Electrical Installation ................................................................................................................................21
Plumbing Hook-Up...................................................................................................................................22
Plumbing Installation ................................................................................................................................23
TABLE OF CONTENTS
Supine Bath Tub 4 Part No 1096926
TABLE OF CONTENTS
SECTION 5—MAINTENANCE ........................................................... 25
Parts Information......................................................................................................................................25
Safety Inspection Checklists...................................................................................................................25
Initially.....................................................................................................................................................25
Before Each Use...................................................................................................................................25
Every 80-150 Baths..............................................................................................................................25
Every Six Months..................................................................................................................................26
Maintenance for IH6300ADH Adjustable Height ONLY Glide Pads...........................................26
Removing Soap Film and Hard Water Deposits ...............................................................................26
Removing Calcium Deposits, Scale and Lime Build-up....................................................................26
Heavy Duty Cleaning Procedure ..........................................................................................................27
Calibrating the Disinfectant Flowmeter ..............................................................................................28
Maintenance Record ................................................................................................................................30
SECTION 6—TROUBLESHOOTING .................................................... 31
LIMITED WARRANTY ..................................................................... 32
SPECIAL NOTES
Part No 1096926 5 Supine Bath Tub
SPECIAL NOTES
Signalwordsareusedinthismanualandapplytohazardsorunsafepracticeswhich
couldresultinpersonalinjuryorpropertydamage.Refertothetablebelowfor
definitionsofthesignalwords.
NOTICE
THE INFORMATION CONTAINED IN THIS DOCUMENT IS SUBJECT TO
CHANGE WITHOUT NOTICE.
RADIO FREQUENCY INTERFERENCE
Most electronic equipment is influenced by Radio Frequency Interference (RFI).
CAUTION should be exercised with regard to the use of portable communication
equipment in the area around such equipment. If RFI causes erratic behavior, PUSH
the Red Power Switch OFF IMMEDIATELY. DO NOT turn the Power Switch ON
while transmission is in progress.
MAINTENANCE
Maintenance MUST be performed ONLY by qualified personnel.
Information on maintenance and adjustment of the thermoscopic mixing valve
(RADA) is in the RADA Owner’s Manual which is included with this product.
SIGNAL WORD MEANING
DANGER
Danger indicates an imminently hazardous situation which, if not avoided, will result in
death or serious injury.
WARNING
Warning indicates a potentially hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION
Caution indicates a potentially hazardous situation which, if not avoided, may result in
property damage or minor injury or both.
LABEL LOCATION
Supine Bath Tub 6 Part No 1096926
LABEL LOCATION
!
WARNING
ELECTRICAL SHOCK HAZARD. All
disassembly and maintenance of the Supine
Tub MUST be done by a qualified technician,
certified electrician or plumber. Disconnect
electrical supply or turn OFF circuit breaker
before performing any maintenance to the
Supine Tub.
1097132 Rev.A(1) - 02/00
!
DANGER
ELECTRICAL SHOCK HAZARD. For use with hospital
grade GFCI receptacle ONLY. Failure to do so may
result in an electrical shock and/or serious or fatal
injury. DO NOT remove this label.
1097131 Rev.A(1) - 02/00
! DANGER
The National Electrical Code requires
the use of a ground fault circuit
interrupter on all therapeutic pools
and tubs (hydro-therapeutic tanks).
Failure to follow this requirement
could result in serious or fatal injury.
1095610 Rev.A(1) - 02/00
CAUTION
Some state and local plumbing codes require the
installation of a “reduced pressure zone” (RPZ) assembly
on both the incoming hot and cold supply lines to prevent
back flow contamination into the potable water system.
Invacare recommends you check local plumbing code
requirements to determine if RPZs are required on your
tub installation. RPZs are NOT supplied by Invacare and
are to be provided by the customer if required.
P/N 1150759 Rev A
! WARNING
BEFORE using the
Supine Tub READ and
UNDERSTAND the
Owner's Manual for
proper operation and
safety procedures
.
Read and understand ALL
information on Invacare
disinfectant BEFORE use.
Refer to Owner's Manual
for proper disinfecting
procedures.
1095523 Rev.A(1) - 02/00
! WARNING
For disinfecting use ONLY. DO NOT use
for showering. Refer to Owner's Manual
for proper disinfecting procedures.
1095526 Rev.A(1) - 02/00
! WARNING
DO NOT stand in tub. Tub surfaces are
slippery when wet. Serious injury may occur.
1097288 Rev.A(1) - 02/00
! WARNING
DO NOT STAND ON TUB FRAME.
Frame is slippery when wet. Foot injury possible
when adjusting tub height.
1095525 Rev.A(1) - 02/00
! WARNING
BEFORE immersing patient or operating the
shower/massage wand, check that the
water temperature is between 95˚ and 105˚
fahrenheit (35˚ and 41˚ C) to avoid scalding
the patient.
1095524 Rev.A(1) - 02/00
! WARNING
This dispensing system has been
factory tested and calibrated for use
with INVACARE Disinfectant. The use of
any disinfectant with a dilution ratio or
viscosity level different than that of
INVACARE Disinfectant will result in an
improper mixture of disinfectant and
water. This may cause your system to be
improperly disinfected - or in some
instances, not disinfected at all. If you
choose to use a product other than
INVACARE Disinfectant, Invacare will not
be responsible for the proper calibration
or function of your disinfectant system.
1095611 Rev.A(1) - 02/00
P/N 1150694 Rev A
DO NOT install a heater in the tub. Installing a heater
will violate safety codes and may result in scalding
injuries to the user.
! WARNING
P/N 1150694 Rev A
1095523
1095526
1097288
1095611
1095524
1095525
1097132
1095610
NOTE:ModelIH6300ADHONLY
1097131
1150759
1150694
Disinfectant
Cabinet
PAR9992




!
"#$%#&$"''()
#!#*&+##,
#%-
'./.0'12).3'1"4.(
(56('72
%,
8'1
(.(6(723
%8
#
5
&)1'7.00.3+./29:;9
%#
!
#%

%
%#<==9
#<
%+
#%
0()



>?0
'?
51
!/8.(
+(.@8&'
#
.
72;
TYPICAL PRODUCT PARAMETERS
Part No 1096926 7 Supine Bath Tub
TYPICAL PRODUCT PARAMETERS
IH6300
FIXED HEIGHT
IH6300ADH
ADJUSTABLE HEIGHT
Height
Tub Rim 32 inches (813 mm)
Raised N/A 41 inches (1041 mm)
Lowered N/A 27 inches (686 mm)
Overall Tub Height 56 inches (1422 mm)
Raised N/A 65 inches (1651 mm)
Lowered N/A 51 inches (1295 mm)
Width
Tub Exterior 38 inches (965 mm) 38 inches (965 mm)
Tub Interior at Shoulder 30 inches (762 mm) 30 inches (762 mm)
Tub Interior at Hip 25 inches (635 mm) 25 inches (635 mm)
Tub Interior at Foot 22 inches (559 mm) 22 inches (559 mm)
Length
Overall Tub Length 94 inches (2388 mm) 94 inches (2388 mm)
Tub Interior 69 inches (1753 mm) 69 inches (1753 mm)
Frame Base 49 inches (1245 mm) 49 inches (1245 mm)
Weight
Tub (shipping weight) 725 lbs (329 kg) 725 lbs (329 kg)
Tub (empty) 700 lbs (318 kg) 700 lbs (318 kg)
Tub w/ 103 gal of water
(max water capacity)
1575 lbs (714 kg) 1575 lbs (714 kg)
Floor Load Capacity
66 PSI (45 n/cm
2
) 66 PSI (45 n/cm
2
)
Water Capacity
Maximum 103 gal (390 l) 103 gal (390 l)
w/ Tub Occupied (average usage) 70-77 gal maximum
(265-292 l)
70-77 gal maximum
(265-292 l)
Water Fill Rate 24 gal per min (91 l/min) 24 gal per min (91 l/min)
Water Pressure 65 PSI maximum (448 kPa) 65 PSI maximum (448 kPa)
Water Drain Rate 25 gal per min (95 l/min) 25 gal per min (95 l/min)
Hydromassage System
Pump Motor 3/4 HP 3/4 HP
Flow Rate 70 gal per min (265 l/min) 70 gal per min (265 l/min)
Electrical
Classification Class I, Type B Class I, Type B
Ingress Protection IPX5 IPX5
Power 115 VAC; 50/60 Hz 115 VAC; 50/60 Hz
Current Rating 11 amp continuous, maximum 13 amp continuous, maximum
FEATURES
Supine Bath Tub 8 Part No 1096926
FEATURES
CONTROL PANEL
TUB INTERIOR
Model IH6300ADH
Adjustable Height Tub
Tub Fill
ON/OFF
Disinfectant
Flow Meter
Disinfectant Wand
Disinfectant
Cabinet
Water Temperature
Thermometer
Shower ON/OFF
Tub Fill Spout
Disinfectant
On/Off
Whirlpool
ON/OFF
Model IH6300
Fixed Height Tub
Tub Controls UP/Down
Whirlpool
Aerator
Whirlpool
Jets
Whirlpool
Inlet
Shower Massage Wand
Water Temperature
Control Valve
Overflow
Drain
NOTE:ModelIH6300ADHAdjustableHeightTubShown.
SECTION 1—GENERAL GUIDELINES
Part No 1096926 9 Supine Bath Tub
SECTION 1—GENERAL GUIDELINES
WARNING
SECTION 1 - GENERAL GUIDELINES contains important information for the safe
operation and use of this product.
Checkallpartsforshippingdamagebeforeusing.Incaseofdamage,DONOTusethe
equipment.ContacttheICCGdealerforfurtherinstructions.
Installation
ICCGassumesnoresponsibilityforcodeinfractionsordamagetocomponentsdueto
improperinstallation.
Useextremecareduringinstallation.
TheinstallationareaMUSTbeabletosupportthe66poundspersquareinchload
capacityoftheSupineTub.
Afterinstallationandbeforeuseensureallpartsareproperlyandsecurelyinstalled.
Ensurebathroomfloorisdryandfreeofobstructionsbeforetransportingorassembling
unit.
BecertainALLelectricalworkisperformedbyaqualifiedelectricianandisincompliance
withlocalelectricalcodes.
Electrical
Grounding Instructions
ModelIH6300SupineTubMUSTbedirectwiredtowallusinghot,neutralandground
wiresinaccordancewiththeNationalElectricalCode.ExternalwiringMUSTbe
groundedthrougha15ampbreakerandGFCIreceptacle.
ModelIH6300ADHSupineTubMUSTbepluggedintoahospitalgradeGFCIreceptacle
witha
15AMPbreaker.
Plumbing
BecertainALLplumbingworkisperformedbyaqualifiedplumber.
Somestateandlocalplumbingcodesrequiretheinstallationofa“reducedpressurezone”
(RPZ)assemblyonboththeincominghotandcoldsupplylinestopreventbackflow
contaminationintothepotablewatersystem.Invacarerecommendsyouchecklocal
plumbingcoderequirementstodetermineifRPZsarerequiredonyourtubinstallation.
RPZsareNOTsuppliedbyInvacareandaretobeprovidedbythecustomerifrequired.
ThehotwatersupplytothetubMUSTNOTexceed110°F(43°C)toprotecttheuserfrom
scalding.
SECTION 1—GENERAL GUIDELINES
Supine Bath Tub 10 Part No 1096926
Whenoperatingwaterpressureexceeds55p.s.i.,pressureregulators(similartothe
¾inchWattsU5)MUSTbeinstalled.
Maintenance and Inspection
IfanypartofthesystemisNOTfunctioningproperly,DONOTusethesystem.Havethe
systemservicedtocorrecttheproblem.
ThesystemMUSTbemaintainedonaregularbasistoensureitisfunctioningproperly.
Electrical Shock Hazard
AlldisassemblyandmaintenanceofthetubMUSTbedonebyaqualifiedtechnician,
certifiedelectricianorplumber.DisconnectelectricalsupplyorturnOffcircuitbreaker
beforeperforminganymaintenancetothetub.
Disinfecting
DisinfectthetubafterinitialsetupandALWAYSdisinfectthetubAFTEReachuseto
avoidresidentinfectionandcontaminationofthetub.
DONOTdisinfectthetubwhenitisoccupiedotherwiseinjurymayoccur.
ALWAYSweargloves,protectiveapron,andfaceshieldprotectionwhendisinfectingor
cleaningyourtub.
ALWAYShandledisinfectants,cleaningcompounds,andpowderedsanitizerswith
extremecare.Physicalormechanicaldamagecausedbyimproperhandlingorusageof
suchproductswillnotbetheresponsibilityofICCG.
DONOTattempttoturnonwhirlpoolpumpduringthedisinfectantcycle.Doingso
couldresultinskinoreyecontactwiththedisinfectant,whichiscorrosive.Ifcontactis
made,rinseIMMEDIATELYwithwater .Ifirritationoccurs,consultaphysician.
ALWAYSreadandfollowdisinfectantlabeldirections carefully.
NEVERuseabrasivecleanerslikescouringpowderorliquidcleanerscontainingpumice
stone.Theuseofthesetypesofcleaners willmake
thegelcoatfinishofyourtubscratched
anddull.NEVERusecleanerscontainingiodine,bromine,Betadine
®
ormethyleneblue.
Theuseofthesetypesofcleanerswillcausethetubtostain.Neverusecleanerscontaining
bleach.Useofthesetypesofcleanerswilldryouttherubbersealsandgasketsandthetub
willnotfunctionproperly.
Operation
DANGER
Keep hair and body away from suction guard when pump is running.
SECTION 1—GENERAL GUIDELINES
Part No 1096926 11 Supine Bath Tub
TheSupineTubisspecificallydesignedtobeusedwithabathlift.ICCGrecommendsuse
oftheTraverseLiftModel1200ONLY.Bathliftsdesignedbyothermanufacturersare
NOTtobeutilizedwiththeSupineTub.Useoftheseproductsisprohibitedandwillvoid
ICCG’sSupineTubwarranty.UseONLYTraverseLiftModel1200tomaintainresident
safetyandproductutility.Refertotheliftownersmanualforcompletelifeoperatingand
safetyinstructions.
NEVERoperatewhirlpoolwithoutwaterlevelabovethewhirlpooljets.Severepump
damagewillresult.
DONOToperatethisunitwithouttheguardoverthe(waterintake)suctionfitting.The
guardisasafetydevicethatreducesthepotentialhazardofhairorbodyentrapment.
Toreducetheriskofinjury,DONOTpermitchildrenorinfirmpersonstousethisunit
unlesstheyaresupervisedatalltimes.
Recommendedlengthofabathis5to10minutes.However,ifyoubecomenauseousor
dizzyordevelopaheadache,getoutatonceandcooldown.Getmedicalattentionif
symptomspersist.Also,checkwithaphysicianbeforeusingthisunitagain.
Anyoneunderadoctorʹssupervision,pregnant,orwithpoorhealth,shouldcheckwitha
physicianbeforeusingthisunit.
DONOTusedirectlyaftereatingorwhileundertheinfluenceofalcoholordrugs.
SECTION 2—DISINFECTING THE TUB
Supine Bath Tub 12 Part No 1096926
SECTION 2—DISINFECTING THE TUB
WARNING
Disinfect the tub after EACH use to avoid resident infection and contamination of the tub.
DO NOT disinfect the tub when it is occupied otherwise injury may occur.
Read and understand all information on Invacare brand disinfectant before use.
ALWAYS wear rubber gloves, an apron and a face shield when using disinfectant. In case of eye or skin
contact, follow procedures on disinfectant container.
The disinfectant dispensing system has been factory tested and calibrated for use with Invacare disinfectant.
The use of any disinfectant with a dilution ratio (½ oz. per gallon) or viscosity level different than that of
Invacare disinfectant will result in an improper mixture of disinfectant and water. This may cause your system
to be improperly disinfected - or in some instances, not disinfected at all. If using any disinfectant with a dilution
ratio or viscosity level different than that of Invacare disinfectant or if switching from one type of disinfectant to
another type, the disinfectant flowmeter MUST be calibrated before performing this procedure. Refer to
Calibrating the Disinfectant Flowmeter
on page 28.
DO NOT use the disinfectant wand for showering. The disinfectant wand is to be used for disinfecting ONLY.
CAUTION
NEVER use abrasive cleaners like scouring powder or liquid cleaners containing pumice stone. The use of
these types of cleaners will make the gel-coat finish of your tub scratched and dull. NEVER use cleaners
containing iodine, bromine, Betadine or methylene blue. The use of these types of cleaners will cause the
tub to stain. Never use cleaners containing bleach. Use of these types of cleaners will dry out the rubber
seals and gaskets and the tub will not function properly.
Disinfecting the Tub Using the Closed Loop System
NOTE:Forthisprocedure,refertoFIGURE 2.1.
NOTE:Ensurethatthewhirlpooljetsandwhirlpool inletfittingareclosedbeforestartingthisproc edure.
1. Cleantheentiretubsurfacetoremov evisibletissueresidueandfluid.
2. Dependingonthetypeofwhirlpooljetsthatareinyourtub,clo seallje tsbyperforming
oneofthe following:
•Turnthecenterofthejetclockwisetoafullstop.
•Pushthecenterofthejetin.
3. Closethewhirlpoolinletbyge ntly pullingthepluginthecenteroftheinletcoveroutw arduntilitstops.
4. Openaerato rbyrotatingaeratorknobtw oturnscounte r clockwise.
5. Open
disinfectantcabinetonthetopofthetub.
6. Ensurethat disinfectantsiphontubeisplacedin
disinfectantcontainer.
7. Holdthedisinfectantwandovertheinteriorofthetub.
8. Adjustwatertemperatureto105°F(40°C).
9. Turndisi nfecta ntOn/OffvalvetotheOnposition.
NOTE:Liquid willbeginflowingfromthedisinfectantwandinto
the
tub.
10. Turntheadjustmentknobontheflowmeteruntilthe
floatingballrisestoalevelof35cc/min.
NOTE:At35cc/min.,disinfectantisbeingmixedwithwaterat
thepr operratio.
11. Continuetoholdthedisinfectantwandoverthe
interiorofthetub.
NOTE:Whendisinfectanthastotallyfilledtheinteriorplumbing,
liquidwillbegintoflowfro mthedisinfectantwand.
NOTE:Invacarerecommendsthatyouthor oughlyscruball
interiorsurfacesofthetubwithdisinfectant.Theuseofalo ng
handledbrushwillmakethisoperationeasier.
12. Spraytheinteriorsurfacesofthetub,includingthe
whirlpooljets,ov erflowfitting
andwhirlpoolinlet
fittingwithdisinfectant.Scruballinteri orsurfaces.
13. TurnthedisinfectantOn/OffvalvetotheOffposit ion.
14. Returndisinfectantwandtoits holder.
15. Afterscrubbingtheinterior surfaces,leavethe
disinfectantintheloopandonthetubsurfacesforten
minutes.
16. Usetheshower/massagewandonthepulsesetting
and
directthesprayintobothwhirlpooljetstobackflush
untilthewaterdisc hargingfromthewhirlpoolinletis
clear.
17. Rinseallinteriortubsurfaces.
18. ReverseSTEPS2and3toope nthewhirlpooljetsand
whirlpoolinlet.
FIGURE 2.1 Disinfecting the Tub Using the Closed Loop
System
Whirlpool Jets
Disinfectant
Wand
Overflow
Disinfectant
Siphon Tube
Whirlpool Inlet
Disinfectant Cabinet
Disinfectant
On/Off Valve
DETAIL “B” -
TUB DETAILS
Push In To
Close
Whirlpool Inlet
Plug
Ball
Turn Clockwise
to Close
Whirlpool Jet
DETAIL “A” -
WHIRLPOOL JET
AND INLET DETAILS
Flow meter
Adjustment Knob
SECTION 3—OPERATION
Part No 1096926 13 Supine Bath Tub
SECTION 3—OPERATION
Overview
Thetu bisdesignedtoimprovetheefficiencyandenvironmentalsafetyof yourfacilityʹs
operation.Howev er,if thetubisnotoperated ormaintainedproperly,thebenefitsdesigned
intothesystemwillnotberealized.Thepurpose ofthismanualis toprovideyouwith
recommendedprocedurestohelpyouobtainthemaximumefficiencyandsafetywhileusing
yourtub.
Whenusingthetub,performtheseproceduresinthefollowingorder:
1. Preparingthetubforuse
2. Transferringtheresidentintothetub
3. Bathing
4. Transferringtheresidentfromthetub
Preparing the Tub for Use
NOTE:Forthispr ocedur e,refertoFIGURE 3.1.
NOTE:Makesurethatyour tubhasbeen
disinfectedbefor epreparingthetubforuse.
NOTE:Thisprocedur emustbeperformedafter
disinfectingthetubtofinalizethedisinfecting
process.
1. Openthewhirlpoolinletbypushingthe
inletplu ginthecenteroftheinletcover
inuntilitstops.
2. Openallwhirlpooljetsbyperforming
oneofthefollowing:
•Turnthecenterjetcounter‐clockwise
toafullstop.
•Pullthecenterof thejetout.
3. Usingshower/massagewandon
Pulsesetting,directwatersprayintothe
whirlpooljetstobackflushthesystem
untilwatercoming
fromthewhirlpool
inletis clear.RefertoOperatingShow er/
MassageWandonpage 15.
4. Rinseallinteriortubsurfaceswith
shower/massagewandonSpraysetting.
5. V isuallyinspecttubfordamageandto
ensurethatalltubsurfacesarecleanand
thatno visibledisin fect antresidue
remains.
FIGURE 3.1 Preparing the Tub for Use
Whirlpool
Inlet
Shower/
Massage
Wand
Inlet
Plug
Whirlpool
Jet
Turn Counter-
Clockwise To Open
Pull Out
To Open
SECTION 3—OPERATION
Supine Bath Tub 14 Part No 1096926
Operating the Tub
WARNING
DO NOT stand in tub. Tub surfaces are slippery when wet. Serious injury may
occur.
DO NOT stand on tub frame. Frame is slippery when wet.
BEFORE immersing the resident or operating the shower/massage wand, check
that the water temperature is between 95° F and 105° F (35° C and 41° C) to avoid
scalding the resident.
Disinfect the tub after EACH use to avoid resident contamination.
NOTE:Forthisprocedure,refertoFIGURE 3.2.
Using Water Temperature Setting
FlowWaterThermometer‐Measuresthetemperatureofwatercomingfromthetubfill
spoutorshower/massagewand.
WaterTemperatureControlValve‐Setsandmaintainsconstanttemperatureforall
incomingwater .
WARNING
ALWAYS hand test the incoming water temperature and the water temperature in
the tub BEFORE immersing the resident. Failure to do so may result in a scalding
injury.
FIGURE 3.2 Using Water Temperature Setting
Whirlpool
Aerator
Flow Water
Thermometer
Shower
ON/OFF
Tub Fill
ON/OFF
Flow Water
Thermometer
Shower
ON/OFF
Tub Fill
ON/OFF
Water Temperature
Control Valve
Whirlpool
On/Off
Tub
Control
Down
Tub
Control
Up
Model IH6300
Model IH6300ADH
Whirlpool
On/Off
SECTION 3—OPERATION
Part No 1096926 15 Supine Bath Tub
Operating Shower/Massage Wand
NOTE:STEPS1‐3aretobeperformedwhileholdingtheshower/massagewandoverthetub.Referto
Featuresonpage 8foradditionalillustrations.
1. Turnshower/massagewandontodesiredflowbyrotatingknob.
2. Adjustwatertemperaturewhilewatchingthermometer.
3. Adjustshowerspraybyrotatingshowerwandhead.
NOTE:Refer tothefollowingchartforshowerheadadjustmentsettings.
4. TurnshowerOn/OffknobtoOffpositionwhenfinished.
Filling the Tub
1. Closethedrain.
2. TurntubfillOn/OffvalvetoOnpositionbyrotatingknob.
3. Adjustwatertemperaturewhilewatchingthermometer.
4. TurntubfillOn/OffvalvetoOffpositionwhenwaterreachesdesiredlev el.
NOTE:If hydr omassageuseisanticipated,waterlevelMUST becompletelyabovewhirlpooljets.
NOTE:Befor estartinghydr omassage,openthewhirlpoolinletandwhirlpoolje ts.
Using Hydromassage
CAUTION
Before starting hydromassage, water level MUST be completely above whirlpool jets
otherwise damage to the motor/pump will result.
1. Openthewhirlpoolin letbypushinginonthepluginthewhirlpoolinletfitting.
2. Openallwhirlpooljetsbyperformingoneofthefollowing:
•Turnthecenterofthejetcounterclockwisetoafullstop.
•Pullthecenterof thejetout.
3. AddInv acareDefoamertobathwater.Re ferto
De foamerbottlefordirections.
4. PushwhirlpoolOn/Offbuttontostartwhirlpooljets.
5. Adjustthewhirlpoolaeratorforde siredwateragitationbyrotatingtheknob.
6. Afteruse,pushwhirlpoolOn/Offbuttontostopwhirlpooljets.
7. Drainthetub.
Stream
Shower Spray
Mixture of Spray and Pulse Massage
Pulse Massage
SECTION 3—OPERATION
Supine Bath Tub 16 Part No 1096926
Adjusting Tub Height - Model IH6300ADH ONLY
WARNING
DO NOT stand on tub frame. Frame is slippery when wet. Foot injury is possible
when adjusting tub height.
CAUTION
DO NOT adjust height more than three cycles (up and down) within a ten minute
period. Damage to the actuator may result.
NOTE:ThesupinetubstopsautomaticallywhenmaximumheightadjustmentUporDownis
reached.
Raising the Supine Tub
1. PressandholdtubcontrolUpbutton.
2. ReleasetubcontrolUpbuttonwhendesiredheightisreached.
Lowering the Supine Tub
1. PressandholdtubcontrolDownbutton.
2. ReleasetubcontrolDownbuttonwhendesiredheightisreached.
SECTION 4—INSTALLATION
Part No 1096926 17 Supine Bath Tub
SECTION 4—INSTALLATION
Preparing the Work Area
NOTE:Forthisprocedure,refertoFIGURE 4.1.
1. Determinelocationforthesupinebathtubinstallation.
NOTE:Followrecommendedfloorplanwheninstallingtub.
2. Carefullyremovethetubfromcarton.
3. Removetubfromshippingpalletbyremovingscrewsfromlegmountingpads.
4. ModelIH6300ONLY‐Removethescrewsthatsecuretherearaccesspaneltoaccess
thepumpelectricalconnections(Detail“A ofFIGURE 4.1).
FIGURE 4.1 Preparing the Work Area
3 ft
(914 mm)
Wall
94 inches (2388 mm)
38 in.
(965 mm)
142 inches (3606 mm)
Screw
(1 of 4)
Access
Panel
Leg Mounting Pads
DETAIL "A"
3 ft
(914 mm)
3 ft
(914 mm)
1 ft
(304 mm)
SECTION 4—INSTALLATION
Supine Bath Tub 18 Part No 1096926
Securing the Tub
NOTE:Forthisprocedure,refertoFIGURE 4.1onpage 17andFIGURE 4.2.
1. Setthetubinplace.
2. Marklocationofanchorholes,usingpredrilledholesinlegmountingpadsasa
template(Detail“A ofFIGURE 4.1).
3. Movetubawayfrommountingarea.
WARNING
Protective eye wear MUST be worn when drilling to avoid possible eye injury.
4. Drillanchorholesinfloor.Useajackdrillwithacarbidebitforconcretefloorsora
woodbitforwoodfloors.
5. Repositionthetubinmountingarea,aligningtheholesinthelegmountingpadswith
theholesdrilledinSTEP4.
WARNING
DO NOT adjust height of legs more than 1 inch (25.4 mm); leg will disassemble
from leg mounting pad and serious injury may occur.
6. Levelthetubbyadjustingthetelescopiclegseitherupordown,usingawrench,to
achievethedesiredheight.
7. Checktomakesuretubislevelbyplacingalevelonthefrontandsidesofthetub
(Detail“A ofFIGURE 4.2).
8. RepeatSTEPS6and7untiltubislevel.
9. Securelegstofloorusingfastenersappropriateforthefloormaterialandinkeeping
withlocalcodes(Detail“B”ofFIGURE 4.2).
FIGURE 4.2 Securing the Tub
DETAIL “A” - LEVELING
Level
Level
Leg
Leg Mounting
Pad
Anchor
1-inch (25.4 mm)
Maximum Adjustment
DETAIL “B” - SECURING TUB
Lag Bolt
Leveling
End to End
Leveling
Side to Side
Lag Bolt
Anchor
SECTION 4—INSTALLATION
Part No 1096926 19 Supine Bath Tub
Electrical Hook-up
WARNING
Be certain ALL electrical work is performed by a qualified electrician and is in
compliance with local electrical codes.
Before installing and connecting the tub, make certain that the electric power
source is SHUT OFF to avoid electrical shock.
NOTE:Forthisprocedure,refertoFIGURE 4.3onpage 20.
NOTE:Forinstallationdetailsrefertoonpage 20.
1. InstalltheelectricalhookupsperFIGURE 4.3.
SECTION 4—INSTALLATION
Supine Bath Tub 20 Part No 1096926
FIGURE 4.3 Electrical Hook-up
Electrical
Hookup
115 V
Electrical
IH6300 Fixed Height
Use 15 Amp GFCI Breaker Only
IH6300ADH Adjustable Height
Use 15 Amp Hospital Grade GFCI Receptacle Only
DETAIL “B” - ELECTRICAL HOOK UP DETAILS
DETAIL “A” - ELECTRICAL HOOK UP LOCATION
Wall
Tub Wall
Pump
Motor
BLACK
WHITE
GREEN
DETAIL “C” - ELECTRICAL SCHEMATIC
Air Switch Line
Motor
Cover
Ground (GREEN)
Line (BLACK)
Neutral (WHITE)
Ground
Line
Neutral
DETAIL “E” - MOTOR END PLATE
DETAIL “D” - MOTOR COVER
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Invacare IH6300ADH Owner's Operator And Maintenance Manual

Type
Owner's Operator And Maintenance Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI