Contents of the package
Thank you for choosing a FRIAX's Monobloc system to control the aging of your wine.
Take the me to read this manual. It will help you understand the steps to install and adjust the MPC series.
What is a cellar Monobloc system FRIAX ?
The MPC serie is a refrigeraon system specially designed to keep the opmum temperature and humidity at
the aging of your wines. The system is composed of three essenals elements which are the evaporator, the
condenser unit and the regulaon box. These elements are interconnected by a refrigerant pipe and an
electrical connecon.
At the delivery, you must nd in your package, your Monobloc, the installaon manual and the accessories
describde on page 3. Check package to detect any damage on the carton. Note on the delivery of the carrier all
the observaons about the package condion, this could be useful in case of damage.
If in doubt contact your dealer.
When unpacking check that the material inside the package corresponds to the checklist on the box.
Safety
-Be sure to install the unit in a sheltered place.
-It is advisable to remove the device from its packaging with the help of someone.
-Connect the power supply once the enƟre installaƟon is complete.
O pallet dimensions:
750 mm x 490 mm x 510 mm ( P x L x H)
MPCA
Genesis - Vintage
Données techniques
3
MPCA 20 MPCA 20 C
Cooling capacity +6°C 500 W 500 W
Cooling capacity +12°C 610 W 610 W
Voltage 230 V - 50Hz 230 V - 50 Hz
Current heaƟng mode -
Power consumpƟon 230 W / 1,2 A 230 W / 1.2 A
Airow cellar side
1 m 1 m
Refrigerant R290 R290
nominal outside temperature
28°C 28°C
4 - 18 °C 4 - 18 °C
Weight 45 kg 49 kg
-
Current cooling mode 2,41 A 3,24 A
210 m3/h
210 m3/h
Temperature seƫng range
Airow outside
250 m3/h
250 m3/h
Power cable lenght
Genesis & Vintage Genesis
Condensate evaporator tray
No Yes
MPCA
Genesis - Vintage
Accessories
Monobloc FRIAX comes with
- A box with wireless remote, table stand for remote control and two baeries
- A exible drain tube Ø 16 2m length
- A bag containing screws xing brackets on the air condioner, this leaet and a ng
20/27 for hose Ø 10 on Vintage versions
Outside
28°C
Cellar
12°C
Condenser
Evaporator
4
260
48 42
204
19243
567
198 75
285
43
25
350
25326
374 139
Evaporator air inlet
Regulation LED + synchronization button Power Supply
Condenseur air outlet
Evaporator air outlet
Condensor air inlet
Dimensions
MPCA
Genesis - Vintage
OperaƟng principal
MPCA
Genesis - Vintage
Installation
Position of the opening in the bottom of the cabinet
5
90 mini
285
75
43
5
13
260 23
199
75199
26023
285
60
MPCA
Genesis - Vintage
Installation
6
567
570 between cleat
60 mini
480 mini
11
60
90
MPCA
Genesis - Vintage
Installation
ConnecƟon of the drain
Only units not equipped with the KBEC opon (condensate evaporaon pan kit) must be
connected to a drain.
Connect the drain
Connect the drain tube (Ø 16) to the end
of the elbow with the supplied collar.
7
MPCA
Genesis - Vintage
+
+
-
-
Wirless remote control
Power supply: 2 x 1.5V (AAA) provided
60
83
80
26
8
The remote control could be installed in any room. Its maximum range is 100m in a
completely open area. This distance could be extremly reduced by thickness of walls
and the locaon of the cellar. It is possible to x directly the remote to the unit by
using the screw holes on the MPC facade.
9
MPCA
Genesis - Vintage
Wireless remote
Configuration type
Key lock indicator
Crankcase heater indicator
Silent indicator (EC fan evaporator)
Heating indicator
Cooling indicator
Condenser temperature probe
Humidifier indicator (
VINTAGE model
)
Cellar temperature probe
Parameter number
Setup mode
Radio frequency signal
Temperature or humidity indicator (option)
Battery charge level indicator
°C / °F or humidity (%) unit indicator
Speed condensor fan
Speed evaporator fan
Time (12 AM/PM or 24 h)
existing if EC evaporator fan
existing if EC condenser fan
Minus for negatives values
Lighting control
%
1
23456789
10
11
12
14
15
13
18
17 16
OK
-
+
Menu key
Return
Navigation key
Start key
Stand by
Stop
Navigation key
Validation key
-Red : heating mode
-Green : cooling mode
-Flashing red : Alarm
19
20
21
22
12
13
14
15
16
17
18
19
20
21
22
1
2
3
4
5
6
7
8
9
10
11
10
MPCA
Genesis - Vintage
First start
Step I - Set the cellar fan speed
-For MPC 30 select the value * and conrm.
-For MPC 48 select the value * and conrm.
* For speed value, see the specic installaon instrucons when the appliance is installed outside the cave
(mounng OUT) and the evaporator is ducted.
Step II - StarƟng
Seng the
speed evapora-
tor fan cellar
Even if the screen
is blank Press
for 6 seconds
Change the
screens with
OK
OK
conrm with
-
+
Change the value with
or
Access to
menu
Parameters Display Handling
See below the value
set according to the
device
Login with
Shorten the waing
period ** hold
Start the unit with the
remote control
The unit starts in heang
or cooling mode. If the set
is idencal to the tempe-
rature of the cellar, the
screen shows no opera-
on.
The unit starts.
If the icons and
are ashing the unit is in
standby mode.
Press
for 2 seconds
or
becomes xed
or
xed or ashing
** It is the preheating of the compressor crankcase heater which avoid any blow of liquid during the
rst start. It is preferable to respect this period until its completion
To exit the menu,
press
funcons Handling Views Remarks
Remarks
11
MPCA
Genesis - Vintage
Settings: temperature and humidity *
OK
Seng Handling Display Remarks
Adjust the tempe-
rature setpoints
and humidity
(Vintage Version)
Press
For 2 seconds Flashing
Flashing
Flashing
Flashing
Displays the current value
of the setpoint tempera-
ture
Displays the current value
of the set point humidity
(* Only on Vintage models)
Displays the value of
setpoint desired humidity
(* Only on Vintage models)
Displays the value of the
desired setpoint tempera-
ture
Returns to the display of
measured values in the
cellar
%
%
OK
conrm with
OK
conrm with
-
+
Change the value with
or
-
+
Change the value with
or
Step III - Set the cellar temperature and humidity
Restart the unit with the
remote control Resume in step II
Stop the unit with the
remote control
Press
for 6 seconds
funcons Handling Views Remarks
Step IV - Stop the unit
Red LED on unit. The air
condioner is stopped but
the funcon of compres-
sor protecon remains
acve RC**
** If the unit remains o for a long period of time, it is better to stop it this way. This will protect the
compressor when restarting
* Only on Vintage models
12
MPCA
Genesis - Vintage
User menu
funcons Handling Views Remarks
Display the tempera-
ture or humidity of the
cellar
Put the fan in the cellar
in silent mode
Exit silent mode
Press
Press
Lock the keypad on the
remote control
Unlock the keypad on
the remote control
Pause the remote
screen
Out of standby screen
Stop the machine with
the remote
Start the unit with the
remote control
Flashing
Fixed
The display alternately
shows the value of the
temperature and humidity
(Only available on Vintage
model)
The fan switches to low
speed for 10 minutes
The fan returns to its
normal speed
Manipulaon buons no
longer possible to change
the sengs
Buons are accessible to
change the sengs
The screen turns o aer
a few seconds. The
appliance connues to
operate
The screen turns on and
displays the current values
Red LED on unit. The air
condioner stopped but
the compressor protecon
remains acve RC
(crankcase heater)
%
-
Press -
Then simultaneously
on
Then simultaneously
on
Press
Disappearing
Disappearing
Flashing
%
The unit starts.
If the lights and
are ashing the unit is in
standby mode.
or
xed
defrost mode Hold
Starts a manual defrost in
addion to the automac
defrost all 7 hours
Press
for 2 seconds
Press
for 2 seconds
Press
for 2 seconds
Press
for 2 seconds
Press
for 6 seconds
Lighng control
Press
5 Seconds
+
Lighng on / o
13
13
MPCA
Genesis - Vintage
User menu
Seng the me
display. 12 or 24
hours
Seng the
temperature
unit
Seng the me
Set hours
Minute seng
Seng ° C / ° F
Switches from 12 h
AM / PM display on
24
Access to
menu
Parameters Display Handling
OK
OK
conrm with
-
+
Change the value with
or
Login with
OK
OK
conrm with
-
+
Change the value with
or
Login with
OK
OK
conrm with
OK
conrm with
-
+
Change the value with
or
-
+
Change the value with
or
Login with
Remarks
Even if the screen
is blank Press
for 6 seconds
Change the
screens with
To exit the menu,
press
14
14
MPCA
Genesis - Vintage
User menu
Access to
menu
Parameters Screens Manipulations
OK
OK
conrm with
-
+
Change the value with
or
Login with
OK
OK
conrm with
-
+
Change the value with
or
Login with
OK
OK
conrm with
-
+
Change the value with
or
Login with
Remarks
This parameter is
set to 0 at the
factory. It may be
modied only in
the case where
there would be a
dierence
between the
seng tempera-
ture and the real
temperature of
the cellar.
This parameter is
set to 0 at the
factory. It may be
modied only in
the case where
there would be a
gap between the
moisture displayed
and the real humi-
dity of the cellar.
Only available on
model Vintage
Lets venlaon at
low speed when
the air condioner
reaches its setpoint
temperatures and
humidity, to have a
permanent air
circulaon in the
cellar.
It is recommended
to leave this seng
enabled when the
evaporator is
ducng (version
OUT).
Calibrang the
temperature
sensor
Calibraon of
humidity probe
Seng the fan
status when the
setpoint is
reached
Even if the screen
is blank Press
for 6 seconds
Change the
screens with
To exit the menu,
press
15
15
Alarms codes MPCA
Genesis - Vintage
Two types of errors may appear on the wireless remote control.
Type 1 alarm : The Green and red LED on the front panel ashes.
A warning message appears on the wireless control and buon
ashes when a buon is pressed.
The air condioner connues to operate.
Type 2 alarm : The red LED on the front panel ashes.
A warning message appears on the wireless control and buon
ashes when a buon is pressed.
The air condioner does not work anymore.
Contact your hardware vendor
Once the problem is solved, press the Sync buon on the unit or on
OK
OK
OK
Genesis temperature signal lost
type 2
Lower threshold wine cellar temperature
type 1
Upper threshold wine cellar temperature
type 1
Faulty wine cellar temperature
type 2
Vintage temperature signal lost
type 2
type 1
type 1
Upper threshold wine cellar humidity
type 1
type 2
Outside unit temperature signal lost
type 1
Upper threshold outside unit temperature
type 1
Faulty outside unit temperature
type 1
Faulty inside unit motor fan
type 2
type 2
Radio signal lost
type 1
AS1c
A SL
A SH
A SO
AS2c
A SL
A SH
AHRH
A SO
AS3c
AS3H
AS3O
AVEc
AVCc
A rF
Faulty outside unit motor fan
Upper threshold wine cellar temperature
Lower threshold wine cellar temperature
Faulty wine cellar temperature
Alarm code Error source
Cellar T° sensor
T° sensor + HR% cellar
(on Vintage model)
Condenser T° sensor
Evaporator fan
condenser fan
wireless communicaon
Type of error
Description
16
How to reset to factory conguraon with te remote controller
Reset
Genesis & Vintage
The reset will change the parameters to their factory value
Set the fan speed, temperature and humidity
Restart the unit
With the remote
Press .
For 2 seconds
Unit starts
If symbol or
ashes, unit is
in stand by mode
Press
unl or
become xed
Press simultaneously
OK
Push
+10 Seconds
SPC
Maintenance
Maintaining your air condioner cellar
The following maintenance repeated every 6 months operaons will allow your air condio-
ner MPC keep its opmal ways to ensure its longevity and your wines.
CAUTION
Before any maintenance work, switch o the power supply to the main circuit breaker.
Maintenance of the condenser (hot side)
Remove the front cover using an Allen wrench to access the condenser coil air. Use a vacuum
cleaner to remove dust. Be careful not to damage the ns.
Maintenance of the evaporator (cold side)
Remove the front cover using an Allen wrench to access the evaporator coil air. Use a vacuum
cleaner to remove dust. Be careful not to damage the ns.
Remove the condensate tray with a screwdriver, clean it with water then reinstall it
17
MPCA
Genesis - Vintage
Compressor
Fan
Heater
Wiring diagram
Solenoid valve on vintage
series
Crankcase heater Temperature sensor
Temperature & humidity sensor
on Vintage series
GND
PWM1
TAC
CP HGR KCH EVF CDF POWER Sonde
cond
LLL LL
NNN NN
blue
Yellow
White
Blue
Blue
Black
Black
5 x 20
10A GT
LN
T°+HGR
or
On Vintage
model
GND
PWM2
TAC2
Blue
Yellow
White
LNLN
EVF CDF
RC
LN
LN
16 A max
AUX (light)
NC NO
COM
COM
NC
NO
(Example)
Detached pieces
Designation Ref.
1 Compressor 30050077
2 Remote PR20050067
3 Control board PR20050070
4 Light switch
PR20070008
5Probe °C + HRG% 20050002-20070035
6 Fan PR20080082
7Drip tray 40010274
Bent hose PR60010039
Condensate pipe 60010291
4
2
1
6
3
7
5
18
19
Manufacturer’s declaration - Compliance with standards
GB-SPC-DF-0317
DECLARE QUE NOTRE APPAREIL APPARTENANT A UNE DES GAMMES SUIVANTES :
DECLARES THAT THIS MACHINE BELONGING TO ONE OF THE FOLLOWING RANGES:
SPC 30 EVPL (Genesis-Vintage) - SPC 48 EVPL (Genesis-Vintage) - SPC 82 EVPL (Genesis-Vintage) -
SPC 122 EVPL (Genesis-Vintage) - SPC 170 EVPL (Genesis-Vintage) - SPC 230 EVPL (Genesis-Vintage)
SPC 30 EVG / EVI (Genesis-Vintage) - SPC 48 EVG / EVI (Genesis-Vintage) - SPC 82 EVG / EVI
(Genesis-Vintage) - SPC 122 EVG / EVI (Genesis-Vintage) - SPC 170 EVG (Genesis-Vintage) - SPC 230
EVG (Genesis-Vintage)
SPC 30 EVA (Genesis-Vintage) – SPC 48 EVA (Genesis-Vintage) – SPC 82 EVA (Genesis-Vintage) – SPC
122 EVA (Genesis-Vintage)
MPC 30 (Genesis-Vintage) – MPC 48 (Genesis-Vintage) - MPCA 30 (Genesis-Vintage)
EST CONFORME:
IS IN CONFORMITY WITH
- AUX DISPOSITIONS DES DIRECTIVES EUROPEENNES SUIVANTES ET A LEURS MODIFICATIONS :
- THE REQUIREMENTS OF THE FOLLOWING EUROPEAN MEASURES AND THEIR MODIFICATION :
2014/35/EU (Basse Tension),
2014/35/EU
(Low Voltage),
2014/30/EU (Compatibilité électromagnétique),
2014/30/EU (Electromagnetic compatibility),
2014/68/EU (Equipements sous pression),
2014/68/EU (Equipements sous pression),
2011/65/EU (RohS),
2011/65/EU (RohS),
- AUX NORMES SUIVANTES :
- THE FOLLOWINGS STANDARDS :
NF C 15 100 (Installation électriques à basse tension),
NF C 15 100 (Low voltage installation),
EN 60204-1 (Equipement électrique des machines),
EN 60204-1 (Electric equipment of machines),
NF EN 378-1 à 4 (Systèmes de réfrigération (…) / Exigences de sécurité et d’environnement),
NF EN 378-1 to 4 (Refrigeration Systems(…) / Safety and environmental requirements),
-
AUX REGLEMENT (CE) 2037/2000 SUR LES SUBSTANCES APPAUVRISSANT LA COUCHE D’OZONE
-
THE REGULATION (EC) 2037/2000 CONCERNING OZONE LAYER DEPLETION PRODUCTS
ET QUE LE MARQUAGE A ETE APPOSE SUR LE MATERIEL.
AND THAT THE MARKING HAS BEEN AFFIXED ON UNIT
Directeur Général
Managing Director
Eric JACQUOT
FRIAX INDUSTRIE - RCS CHAMBERY 477 811 517
ZAC de la Prairie – F73420 VOGLANS
Tel : +33 (4) 79 34 91 84 – Fax : +33 (4) 79 34 91 85 [email protected]
Site web :www.friax.fr
Boite mail : @friax.fr
info
R
INDUSTRIE
231/233 Rue de la Prairie
F-73420 Voglans
Découvrez notre de cave de rangement pour la cave!
site web: www.visiorack.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20