Little GIANT 558589 Installation guide

Type
Installation guide
OWNER’S MANUAL
4” SUBMERSIBLE PUMP
BEFORE INSTALLING PUMP, BE SURE TO READ
THIS OWNER’S MANUAL CAREFULLY.
Fill the pump with water before starting or
the pump will be damaged. The motor on this pump is
guaranteed by the manufacturer, and in the event of failure
it must be returned to an authorized service station for
repairs. The motor warranty is void if repairs are not made
by an authorized repair station.
INSPECT THE SHIPMENT
Examine the pump when it is received to be sure there
has been no damage in shipping. Should any be evident,
report it immediately to the dealer from whom the pump
was purchased. Please check the pump package to see
that it includes pump, motor, and motor leads (if your pump
purchase includes a motor).
This pump includes either a built-in or externally-mounted
check valve with the discharge head. Make certain that your
available voltage corresponds to that of your motor.
CAUTION
READ AND FOLLOW SAFETY
INSTRUCTIONS
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one of
the following signal words and be alert to the potential for
personal injury:
DANGER
warns about hazards that will cause serious
personal injury, death, or major property damage if ignored.
WARNING
warns about hazards that can cause serious
personal injury, death, or major property damage if ignored.
CAUTION
warns about hazards that will or can cause
minor personal injury or major property damage if ignored.
The label NOTICE indicates special instructions, which are
important but not related to hazards.
Carefully read and follow all safety instructions in this
manual and on pump.
Keep safety labels in good condition.
Replace missing or damaged safety labels.
Wire motor for correct
voltage. See Electrical
Information section of this manual
and motor nameplate.
Ground motor before
connecting to power supply.
Meet National Electrical
Code, Canadian Electrical
Code, and local codes for all
wiring.
Follow wiring instructions in
this manual when
connecting motor to power lines.
Hazardous voltage.
Can shock, burn, or
cause death.
Ground pump before
connecting to power
supply. Disconnect
power before working
on pump, motor
or tank.
WARNING
Franklin Electric Co., Inc.
www.franklinwater.com
ATTENTION!
IMPORTANT INFORMATION FOR
INSTALLERS OF THIS EQUIPMENT!
THIS EQUIPMENT IS INTENDED FOR INSTALLATION BY
TECHNICALLY-QUALIFIED PERSONNEL. FAILURE TO
INSTALL IT IN COMPLIANCE WITH NATIONAL AND LOCAL
ELECTRICAL CODES AND WITH FRANKLIN ELECTRIC
RECOMMENDATIONS MAY RESULT IN ELECTRICAL SHOCK
OR FIRE HAZARD, UNSATISFACTORY PERFORMANCE,
Form 106257101 Rev. 002 11/2013
2
AND EQUIPMENT FAILURE. FRANKLIN ELECTRIC
INSTALLATION INFORMATION IS AVAILABLE FROM PUMP
MANUFACTURERS AND DISTRIBUTORS, AND DIRECTLY
FROM FRANKLIN ELECTRIC. CALL FRANKLIN ELECTRIC
TOLL FREE AT 800-701-7894 FOR INFORMATION. RETAIN
THIS INFORMATION SHEET WITH THE EQUIPMENT FOR
FUTURE REFERENCE.
WARNING
SERIOUS OR FATAL ELECTRICAL SHOCK MAY RESULT
FROM FAILURE TO CONNECT THE MOTOR, CONTROL
ENCLOSURES, METAL PLUMBING, AND ALL OTHER
METAL NEAR THE MOTOR OR CABLE TO THE POWER
SUPPLY GROUND TERMINAL USING WIRE NO SMALLER
THAN MOTOR CABLE WIRES. TO REDUCE RISK OF
ELECTRICAL SHOCK, DISCONNECT POWER BEFORE
WORKING ON OR AROUND THE WATER SYSTEM. DO
NOT USE MOTOR IN SWIMMING AREAS.
INSTALLATION RECORDS
It is a good idea to keep an accurate record of your
installation. Be sure to record the data below:
Purchased from:
Date of installation:
Pump model*:
Pump date code*:
Well inside diameter (in/mm):
Depth of well (ft/m):
Depth of water (ft/m):
Pump setting (ft/m):
Drop pipe size:
Wire size (pump to control box):
Wire size (control box to power source):
Horizontal offset (between well & house):
Make of motor*
Amps HP Volts Phase
Make of control box
HP Volts
Power supply
Volts HZ
Pressure switch limits
Cut-in (PSI) Cut-out (PSI)
*This information is on your pump or motor tag. It will help
us identify your pump in case of later inquiries.
TEST RUNNING
If test running pump before installation:
1. Ensure that the power supply corresponds with that
shown on the nameplate of the motor and control box (if
required).
2. Install pump and components appropriate for the test as
shown in Fig. 1.
3. Make sure power supply is turned off and circuit
breaker or disconnect switch is open. Make electrical
connections appropriate to your motor as shown in
Figure 2, 3 or 4.
4. On a three-phase motor, use a magnetic starter equipped
with quick-trip, ambient compensated heaters of correct
size for the horsepower of the motor.
To ensure correct rotation of three-phase units, brace
pump shell securely and apply power momentarily by
snapping line switch quickly on and off. If rotation is
correct, reaction of the shell will be clockwise when
viewed from pump discharge (that is, pump shaft will
rotate counter clockwise). Interchange any two leads at
magnetic starter to reverse rotation.
5. Run pump and motor unit for a few seconds to ensure
that it is in working order.
FIGURE 1
Installation Diagram
Pressure tank
Pressure switch
Gate valve
Service pipe
Pressure gauge
Pressure relief valve
Spring-loaded
check valve
See Wiring Diagrams
Sanitary well seal
or pitless adapter
Discharge pipe
Submersible cable
Spring-loaded
check valve
(Recommended every 100’/30m)
Safety cable
Drop pipe
Cable
(secured to drop
pipe with tape or
clamps every 10’/3m)
Well casing
Spring-loaded
check valve
at pump discharge
Submersible
pump
Suction screen
Motor
Well screen or
casing perforations
Note: Keep pump at least 5' (1.5 m) from
bottom of well and above well screen
or casing perforations.
Torque arrestor
SUITABILITY OF WELL
Install the pump only in a well that has been properly
developed. Water from an undeveloped well often contains
an excessive amount of sand, dirt, and abrasives which can
damage the pump. Check that the well is large enough to
3
allow the pump to be set at the required depth. Do not set the
pump below the casing perforations or well screen unless you
make arrangements to ensure an adequate ow of water over
the motor for cooling purposes. Determine the correct pump
setting from the driller’s record by taking into account the
static water level and the drawdown at the proposed pumping
rate. Keep the pump at least ve feet from the bottom of a
drilled well.
SPLICING THE POWER CABLE
Follow the instructions enclosed in the cable splicing kit
(purchased separately).
DROP PIPE
Submersible drop pipe manufacturer’s usage guidelines
should always be followed when suspending a submersible
pump in a well. Generally either galvanized steel or plastic are
used for the pump drop pipe. When using plastic piping it is
important to follow the manufacturer’s depth and pressure
rating. Give special consideration to:
1. A safety cable to prevent loss of pump if pipe should break.
2. A torque arrestor just above pump to prevent chang the
cable when pump and pipe twist during the starting and
stopping cycle. (See Figure 1.)
Schedule 40 galvanized pipe is suitable for settings to 600
feet (180m). For deeper settings, use schedule 40 pipe for the
bottom 600 feet (180m), and schedule 80 for the remainder.
NOTICE: Drop pipe sizes and usages depths should be
considered as general guidelines only. Drop pipe manufacturer
data and recommendations supersedes these instructions.
Take great care to keep pipes clean and free from pebbles,
scale, and thread chips. Make sound, air-tight connections at
all ttings. Pipe sealant is recommended.
CHECK VALVES
It is recommended that one or more check valves always be
used in submersible pump installations. If the pump does not
have a built-in check valve, an inline check valve should be
installed in the discharge line within 25 feet of the pump and
below the draw down level of the water supply. If permitted by
local codes it is recommended that an additional check valve
be installed in the system plumbing between the wellhead
and the system’s pressure tank. For pump installations that
are more than 200 feet (60m) below the wellhead; additional
check valves should be installed in the drop pipe. This should
be done at intervals of 200 feet (60m) or at the check valve
manufacturer’s specied installation interval. More than one
check valve is often needed, but more than the recommended
number of check valves should not be used.
Swing type check valves are not acceptable and should never
be used with submersible motors/pumps. Swing type check
valves have a slower reaction time which can cause water
hammer (see next page). Internal pump check valves or spring
loaded check valves close quickly and help eliminate water
hammer.
Check valves are used to hold pressure in the system when
the pump stops. They also prevent backspin, water hammer
and upthrust. Any of these can lead to early pump or motor
failure.
NOTE: Only positive sealing check valves should be used in
submersible installations. Although drilling the check valve or
using drain-back check valves may prevent back spinning,
they create upthrust and water hammer problems.
A. Backspin - With no check valve or a failed check valve,
the water in the drop pipe and the water in the system can
ow down the discharge pipe when the motor stops. This can
cause the pump to rotate in a reverse direction. If the motor is
started while it is back spinning, an excessive force is placed
across the pump-motor assembly that can cause impeller
damage, motor or pump shaft breakage, excessive bearing
wear, etc.
B. Upthrust - With no check valve, a leaking check valve, or
drilled check valve, the unit starts under a zero head condition.
This causes an uplifting or upthrust on the impeller-shaft
assembly in the pump. This upward movement carries across
the pump-motor coupling and creates an upthrust condition in
the motor. Repeated upthrust can cause premature failure of
both the pump and the motor.
C. Water Hammer - If the lowest check valve is more than 30
feet above the standing (lowest static) water level, or a lower
check valve leaks and the check valve above holds, a vacuum
is created in the discharge piping. On the next pump start,
water moving at very high velocity lls the void and strikes the
closed check valve and the stationary water in the pipe above
it, causing a hydraulic shock. This shock can split pipes, break
joints and damage the pump and/or motor. Water hammer can
often be heard or felt. When discovered, the system should
be shut down and the pump installer contacted to correct the
problem.
REMOVABLE POPPET CHECK VALVE
4” submersible pumps with a 1-1/4” discharge are supplied
with a spring-loaded, removable poppet check valve
assembly. This check valve can be removed from the pump
discharge when drain back is desired.
WARNING
Fluid draining back through the pump can
cause the pump to rotate backwards. If pump/motor starts
during this time, damage to the pump can occur.
The check valve can be removed using a T-handle poppet
wrench (purchased separately), or with standard needle-nosed
pliers. The poppet assembly is left-hand threaded and is
removed by turning clockwise.
When reinstalling a poppet check valve assembly, tighten it to
15 inch-pounds.
Poppet Assembly
T-Handle Poppet Wrench
INSTALLATION OF PUMP, DROP PIPE, AND
ASSOCIATED EQUIPMENT
Figure 1 illustrates a typical well installation showing in ground
components. Adhere to the following items when installing the
pump and drop pipe:
1. Fasten the submersible cable to the drop pipe with clamps
or appropriate tape every 10 ft. (3m) to prevent tangling and
4
damage to the cable. The cable must remain slack when
using plastic drop pipe to allow for stretching of pipe when
installed in the well.
2. Take care not to scrape or pinch the submersible cable
against the well casing.
One sentence needs to be together on same page
3. Use an ohmmeter or megger to make insulation and
continuity checks on the cable once the pump is installed.
This locates any fault in the cable.
4. Make sure a check valve is in accordance with the
guidelines in this manual.
5. Install a torque arrestor just above the pump to prevent
chang the cable when pump and pipe twist during starting
and stopping.
6. Attach a safety cable to pump to prevent loss of pump if
pipe should break.
7. Place a sanitary well seal or pitless adapter with an
approved cover plate over top of well per manufacturers
recommendations.
8. Keep pump at least 5’ (1.5m) from bottom of well and above
well screen or casing perforations.
ELECTRICAL INFORMATION
1. Employ a licensed electrician to perform the wiring. All
wiring must be done in accordance with applicable national
and local electrical codes.
2. Check that the power supply corresponds with the electrical
rating of the submersible motor and the control box (if
required). Make sure that the control box electrical rating
matches the motor electrical rating.
3. Every installation requires a fused disconnect switch or
circuit breaker.
4. Every installation must be grounded. There must be a
reliable ground connection between the pump and the
distribution panel. The motor lead incorporates a green
grounding conductor.
5. Lightning arrestors are recommended for every installation.
All stainless steel, single phase motors through 5CV
have built-in lightning arrestors. 3-phase motors require
a separate lightning arrestor installed as close to the
wellhead as possible. Install the arrestor in accordance
with manufacturer’s recommendations. Lightning arrestors
provide protection against only induced voltage surges on
secondary power lines; they are not effective against direct
hits.
6. Mount the control box in an area protected from rain, snow,
direct sunlight, or other high temperatures as this may
cause tripping of the overload protector. Also protect the
control box from extreme cold (below 25
o
F/-32
o
C) as this
may have adverse effects on the starting capacitor.
7. A two-wire pump does not require a motor control box; all
electrical components are built inside the motor. Figure 2
shows a typical wiring diagram for a two-wire installation.
FIGURE 2
2-wire, 1-phase, 1/3 through 1-1/2 HP
Pump Wiring Diagram
Incoming 1-phase power
1-phase submersible motor
Submersible cable
Switch or timer
Circuit breaker or
fuse disconnect switch
8. A three-wire, 1-phase pump requires a motor control box
incorporating overload relays. Figure 3 shows a typical
wiring diagram for a three-wire, single-phase installation.
Note that a magnetic contactor must be used if the
pressure switch electrical rating is not sufcient to handle
the submersible motor electrical rating. The pressure switch
would then be incorporated into a pilot circuit to control the
magnetic contactor. Make the connections at the control
box in accordance with the wiring diagram in the control
box to avoid damage to the motor.
FIGURE 3
3-wire, 1-phase, 1/3 through 15 HP
Pump Wiring Diagram
Circuit breaker
or fused disconnect switch
Pressure switch for pilot circuit
(if magnetic contactor is used
for starting)
Single-phase
control box
Red
Yellow
Black
1-phase sumbersible motor
Switch or timer (for direct switching) OR
magnetic contactor (w/pilot circuit)
Incoming 1-phase power
Note: Order of red, yellow, and black may
vary from control box to control box.
Always connect like colors.
L1
L2 R
Y B
9. A three-wire, three-phase pump does not require a motor
control box . Figure 4 shows a typical wiring diagram
for a three-wire, three-phase installation. A magnetic
contractor with three-leg protection and quick-trip ambient
compensated overload relays must be used.
FIGURE 4
3-wire, 3-phase, 1-1/2 thru 50 HP
Pump Wiring Diagram
Incoming 3-phase power
3-phase submersible motor
Circuit breaker OR
fused disconnect switch
Pressure switch
Magnetic contactor with
3-leg protection and
quick-trip ambient
compensated overload relays
5
10. Use an ohm meter to make continuity and insulation
checks after the installation is completed.
11. Place the additional pump nameplate onto the submersible
label and place both onto disconnect switch or circuit
breaker box for future reference.
WELL TEST
Check the pump and well performance before making
the nal connection to the discharge system.
1. Install a gate valve on the end of the pipe. Partially
open the valve.
2. Start the pump.
3. Open the valve gradually to give full ow.
4. If the discharge is not clear, let the pump run until
water clears. If water does not clear in 30 minutes,
stop the pump and take the necessary steps to
correct the condition. After the water appears clear,
check for sand by discharging into a clean bucket or
suitable container.
5. Close valve until maximum required system ow
rate is obtained. This should correspond to the
cut-in pressure of the pressure switch. Ensure that
the output of the pump at this setting is not greater
than the yield of the well. This can be checked by
monitoring the well drawdown level and ensuring that
the level is stable at the maximum required system
ow rate.
CAUTION
Never run the pump unless it is
completely submerged in water. If run without
water, the pump and motor could be damaged.
Note also that air drawn into the pump can cause
an airlock under certain conditions.
LOW-YIELDING WELL
A low-yielding well exists when the output from the pump is
greater than the yield of the well. It can reduce the water level
to the suction screen so that a mixture of air and water enters
the pump. Pumping may stop since the pump cannot generate
pressure with insufcient water. In this case, the column of
water already in the drop pipe holds the check valve closed
and an airlock may develop inside the pump. Because the
conditions ensure neither adequate lubrication of the pump
nor proper cooling for the motor, damage can result if power is
not cut off quickly. Use one or more of the following methods
to correct and/or protect this installation.
1. Install an additional length of drop pipe to place pump lower
in well if possible.
2. Install a Franklin Pumptec or similar electronic drawdown
sensor.
3. Install a oatless liquid level control. This device consists of
an electrical relay activated by currents owing through the
ground-return circuits of electrodes hung in the well. The
lower (stop) electrode, just above the pump, ensures that
the water level can never be pumped down to the suction
screen. The upper (start) electrode, just below the lowest
static water level, ensures that the pump can start again
as soon as the well has recovered. A oatless liquid level
control works in series with the pressure switch. Refer to
the manufacturers instructions provided with the control.
4. Install a ow control valve in the discharge line upstream
from the pressure switch. This restricts the output from the
pump without affecting the rate that water can be drawn
from the pressure tank. Nevertheless, a heavy demand
for water could empty the pressure tank, so a tank with a
bonded diaphragm, air cell, or water bag is recommended.
5. Install a smaller pump to avoid over-pumping the well. Have
the dealer size the pump to the well yield.
6. Install a low pressure cut off switch, or a pressure switch
with such an arrangement built in. This protects a shallow-
well pump from losing its prime, but it does not always
provide satisfactory protection to a submersible pump
from the effects of over-pumping the well. This is because
it responds to a loss of pressure at the surface, which may
occur after an air lock has formed inside the pump. Either
a oatless liquid level control or a ow control valve, in that
order, is recommended in preference to a low-pressure
cutoff switch as protection against over-pumping.
DISCHARGE PLUMBING
Figure 1 illustrates a typical well installation showing above-
ground components. Refer to Figure 1 and the following steps
when installing the discharge plumbing.
1. Install an above-ground check-valve upstream from the
pressure switch.
2. Always install a pressure relief valve in the system. The relief
valve should be capable of discharging the ow rate of the
pump at the rated working pressure of the pressure tank.
Locate the relief valve close to the pressure tank.
3. Install a pressure switch between the check valve and the
pressure tank. Refer to Figure 2, 3, or 4 for proper wiring
connections of pressure switch.
4. Install a pressure tank as close as possible to the pressure
switch. Refer to manufacturer’s recommendations for
installation.
INSTALLATION IN LAKE OR STREAM
A submersible pump is usually isolated at the bottom of a well,
where electrical leakage from its motor and cable presents no
hazard to life. This natural protection is lost when it is installed
it in a lake, pond, stream, or fountain because there is no way
to stop people and animals from entering or touching the
surrounding water. It is recommended that such an installation
be done by a licensed electrician in conformance with all
applicable national and local electrical codes. Grounding
as described in this manual is a minimum requirement, and
a ground fault circuit interrupter (GFCI) is advisable. But
in the absence of explicit national or local regulations, ask
the local electric utility for guidance. In any case, support
the pump from the shore or bottom at a 15
o
slant to assure
proper motor bearing lubrication. Shield the pump from direct
physical contact by people and animals. Protect and screen
the pump intake to prevent blockage by leaves and weeds,
but remember the need for adequate ow over the motor for
cooling purposes. In addition, protect the entire underwater
installation from water currents, ice, boats, anchors, debris,
vandalism, and other hazards.
6
TROUBLESHOOTING
1. PUMP FAILS TO START
a) Electrical trouble - call dealer or electrician
b) Drawdown protection device has pump turned off
c) Overload tripped
d) Reset low pressure cutoff switch (if installed)
2. PUMP FAILS TO DELIVER WATER
a) Air lock in pump
b) Clogged intake screen
c) Insufcient well yield
3. PUMP GIVES REDUCED OUTPUT
a) Insufcient well yield
b) Worn pump
c) Clogged intake screen
d) Low voltage
e) Incorrect rotation (3-phase only)
4. PUMP CYCLES TOO FREQUENTLY
a) Excessive pressure drop between pressure switch and
pressure tank
b) Cut-in pressure at pressure tank too high
c) Cut-out pressure at pressure tank too low
d) Waterlogged pressure tank
e) Start and stop electrodes of oatless liquid level control
set too close together
f) Tank sized too small to meet system requirements
5. OVERLOADS TRIP
a) Electrical trouble - call dealer or electrician
6. PRESSURE SWITCH CYCLES RAPIDLY WHEN
PUMP STARTS
a) Pressure switch too far from pressure tank
b) Improper air charge of tank - adjust to manufacturer’s
recommendations
19
LIMITED WARRANTY
THIS WARRANTY SETS FORTH THE COMPANY’S SOLE
OBLIGATION AND PURCHASER’S EXCLUSIVE REMEDY
FOR DEFECTIVE PRODUCT.
Franklin Electric Company, Inc. and its subsidiaries (hereafter “the
Company”) warrants that the products accompanied by this warranty are
free from defects in materials or workmanship of the Company that exist
at the time of sale by the Company and which occur or exist within the
applicable warranty period. Any distributor, sub-distributor, recipient, end-
user and/or consumer agrees that by accepting the receipt of the products,
the distributor, sub-distributor, recipient, end user and/or consumer
expressly agrees to be bound by the terms of the warranty set forth herein.
I. Applicable Warranty Period
The products accompanied by this warranty shall be covered by this
Limited Warranty for a period of 12 months from the date of original
purchase by the consumer. In the absence of suitable proof of purchase
date, the warranty period of this product will begin to run on the product’s
date of manufacture.
II. Instructions Applicable to this Limited Warranty
1. Consumers wishing to submit a warranty claim must return the products
accompanied by this warranty to the point of purchase for
warranty consideration.
2. Upon discovery of a defect, any personal injury, property damage
or any other type of resulting damage, if applicable, shall be
reasonably mitigated to the extent possible.
3. At its discretion, the Company may inspect products either at its facilities or in
the field, and after determination of a warranty claim, will, at its option, repair
or replace defective parts. Repaired or replaced parts will be returned freight
prepaid by the Company.
4. This warranty policy does not cover any labor or shipping charges. The
Company shall not be liable for any costs or charges attributable to
any product testing, maintenance, installation, repair or removal, or
for any tools, supplies, or equipment needed to install, repair, or
remove any product.
III. Limitations Applicable to this Limited Warranty
THIS WARRANTY DOES NOT APPLY TO ANY OF THE FOLLOWING:
1. Any product that is not installed, applied, maintained and used in
accordance with the Company’s published instructions, applicable
codes, applicable ordinances and/or with generally accepted
industry standards.
2. Any product that has been subject to misuse, misapplication, neglect,
alteration, accident, abuse, tampering, acts of God (including
lightning), acts of terrorism, acts of war, fire, improper storage or
installation, improper use, improper maintenance or repair, damage
or casualty, or to an excess of the recommended maximums as set
forth in the product instructions.
3. Any product that is operated with any accessory, equipment, component, or
part not specifically approved by the Company.
4. Use of replacement parts not sold by the Company, the unauthorized
addition of non-Company products to other Company products, and
the unauthorized alteration of Company products.
5. Products damaged by normal wear and tear, normal maintenance
services and the parts used in connection with such service, or any other
conditions beyond the control of the Company.
6. Any product that has been used for purposes other than those for which it was
designed and manufactured.
7. Any use of the product where installation instructions and/or instructions for
use were not followed.
The Company reserves the right at any time, and from time to time,
to make changes in the design and/or improvements upon its
product without thereby imposing any obligation upon itself to make
corresponding changes or improvements in or upon its products already
manufactured and/or previously sold. The Company further reserves
the right to substitute parts or components of substantially equal quality
in any warranty service required by operation of this Limited Warranty.
This written Limited Warranty is the entire warranty authorized and offered
by the Company. There are no warranties or representations beyond
those expressed in this document.
THIS WARRANTY AND REMEDY IS IN LIEU OF ALL OTHER
WARRANTIES AND REMEDIES INCLUDING WITHOUT LIMITATION,
WARRANTIES OF MERCHANTABILITY AND/OR FITNESS FOR A
PARTICULAR PURPOSE, WHICH ARE HEREBY SPECIFICALLY
DISCLAIMED AND EXPRESSLY EXCLUDED. CORRECTION OF NON-
CONFORMITIES, IN THE MANNER AND FOR THE PERIOD OF TIME
AS SET FORTH ABOVE, SHALL CONSTITUTE FULFILLMENT OF
ALL LIABILITY OF THE COMPANY TO THE PURCHASER WHETHER
BASED ON CONTRACT, NEGLIGENCE, OR OTHERWISE.
THE COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES SUCH AS, BUT NOT
LIMITED TO:
DAMAGE TO OR LOSS OF OTHER PROPERTY OR EQUIPMENT, LOSS
OF USE OF EQUIPMENT, FACILITIES OR SERVICE, LOSS OF PROFIT
OR SALES, COST OF PURCHASES OR REPLACEMENT GOODS,
CLAIMS OF CUSTOMERS OF THE PURCHASER, FAILURE TO WARN
AND/OR INSTRUCT, LOSS OF OTHER PRODUCTS, OR COSTS OF
ENVIRONMENTAL REMEDIATION, OR DIMINUTION IN PROPERTY
VALUE. THE REMEDIES OF THE PURCHASER SET FORTH HEREIN
ARE EXCLUSIVE, AND THE LIABILITY OF THE COMPANY SHALL
NOT, EXCEPT AS EXPRESSLY PROVIDED HEREIN, EXCEED THE
PRICE OF THE PRODUCTS UPON WHICH SUCH LIABILITY IS
BASED. DAMAGES AS SET FORTH IN THIS PARAGRAPH SHALL
BE REASONABLY MITIGATED TO THE EXTENT POSSIBLE. THIS
PARAGRAPH SHALL ALSO APPLY TO ALL DAMAGES RESULTING
FROM CONDITIONS SET FORTH IN SECTION III ABOVE AND (1)
DEFECTS IN PRODUCT PROTOTYPES OR REPLACEMENT PART
PROTOTYPES THAT HAVE NOT BEEN PUT INTO PRODUCTION,
CIRCULATED AND SOLD BY THE COMPANY, AND/OR (2) DEFECTS
THAT WERE NOT FOUND AT THE TIME OF SALE DUE TO SCIENTIFIC
AND TECHNOLOGICAL REASONS.
This Limited Warranty gives you specific legal rights. You may have
other rights, which vary according to the applicable laws and regulations.
Where any term of this warranty is prohibited by such laws, it shall be
null and void, but the remainder of this warranty shall remain in full force
and effect.
DISCLAIMER: Any oral statements about the product made by the seller,
the Company, the representatives or any other parties, do not constitute
warranties, shall not be relied upon by the user, and are not part of the
contract for sale. Seller’s and the Company’s only obligation, and buyer’s
only remedy, shall be the replacement and/or repair by the Company of
the product as described above. Before using, the user shall determine
the suitability of the product for his intended use, and user assumes all
risk and liability whatsoever in connection therewith.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Little GIANT 558589 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI