AGA 3 oven gas Power Flue AIMS Owner's manual

Type
Owner's manual

This manual is also suitable for

AGA 3 oven gas Power Flue AIMS upgrade guide

This guide provides instructions for upgrading your AGA 3 oven gas Power Flue cooker with the AIMS (Advanced Intelligent Management System) upgrade. AIMS is a sophisticated electronic control system that offers a range of features to enhance the performance and efficiency of your cooker.

With AIMS, you can:

  • Control the temperature of each oven independently: This allows you to cook different dishes at different temperatures simultaneously.
  • Program the cooker to turn on and off automatically: This is useful for preheating the oven before you get home or for cooking meals while you're out.

AGA 3 oven gas Power Flue AIMS upgrade guide

This guide provides instructions for upgrading your AGA 3 oven gas Power Flue cooker with the AIMS (Advanced Intelligent Management System) upgrade. AIMS is a sophisticated electronic control system that offers a range of features to enhance the performance and efficiency of your cooker.

With AIMS, you can:

  • Control the temperature of each oven independently: This allows you to cook different dishes at different temperatures simultaneously.
  • Program the cooker to turn on and off automatically: This is useful for preheating the oven before you get home or for cooking meals while you're out.
05/09 EINS 515702
Retro-Fit Kit Instruction Sheet
Aga 3 Oven Power Flue
STRIP DOWN PROCEDURE
1. Isolate gas and electrical supply.
2. Disconnect and remove shrouds from top plate.
3. Remove flue mixing shroud. (Fig. 1)
4. Remove thermostat phials from location bracket and
location bracket from flue nozzle outlet (Fig. 2).
5. Disconnect wiring from fan unit.
6. Disconnect solenoid cable and remove:
a) connections L2, N2 and earth on electrical
chassis.
b) solenoid plug from burner.
7. Remove electrical chassis.
8. Disconnect and remove burner assembly.
9. Remove top plate.
10. Remove insulation and vermiculite from LH of
cooker down to baking oven level.
11. Remove hotspot from fire barrel.
12. Remove fire barrel complete with tunnel assembly.
13. Remove cable guide tube, gas inlet pipe and oven
stat guide tube from burner housing.
14. Remove burner housing assembly.
REBUILD
1. Fit new burner housing complete with insulation pad
JPAD212038 (Fig. 3).
2. Refit cable guide tube, gas inlet pipe and oven stat
guide to burner housing.
3. Refit fire barrel complete with tunnel assembly. Seal
with ropes and gaskets supplied.
4. Refit hotspot and check levels.
5. Refill with vermiculite.
6. Fit new top plate insulation blanket.
7. Refit top plate
8. Refit electrical chassis.
9. Reconnect wiring to fan unit.
10. Refit thermostat phial location bracket to flue outlet
nozzle and refit thermostats.
11. Refit flue mxing shroud.
12. Fit new burner assembly and reconnect to gas
supply (Fig. 4).
Fig. 1
Fig. 2
Fig. 3
13. Feed wiring harness from ‘AIMS’ controller through
cable guide tube up to electrical chassis.
14. Connect wiring harness to electrical chassis. (Fig. 5).
See Page 11 Installation instructions.
15. Secure PCB mounting plate to burner housing.
Ensure gasket is fitted between mounting plate and
burner housing and also ‘L’ shaped pad is fitted
behind PCB mounting plate.
16. Feed ‘AIMS’ thermocouple and oven stat phial
through guide tube into roasting oven. Secure to
new phial support plate and fix to top of roasting
oven. Page 11 installation instructions.
17. Fit controls cover ensuring solenoid cables pass
through ‘half moon’ notches in RH side and AIMS
thermocouple passes through notch at top rear of
RH side of cover.
18. Connect solenoid plugs to burner assembly:
a) Mains inlet solenoid plug should be identified
with coloured marker.
This connects to normally closed solenoid
(aluminium body).
b) AIMS control solenoid plug connects to
normally open solenoid (brass body).
19. Refit shrouds to top plate.
20. Fit new control door lining panel (AG2M212109)
complete with lighting instruction label
(AG4M212085). (Fig. 6).
FOR COMMISSIONING OF BURNER AND AIMS SET-
UP REFER TO INSTALLATION INSTRUCTIONS
Fig. 4
Fig. 5
Fig. 6
  • Page 1 1
  • Page 2 2

AGA 3 oven gas Power Flue AIMS Owner's manual

Type
Owner's manual
This manual is also suitable for

AGA 3 oven gas Power Flue AIMS upgrade guide

This guide provides instructions for upgrading your AGA 3 oven gas Power Flue cooker with the AIMS (Advanced Intelligent Management System) upgrade. AIMS is a sophisticated electronic control system that offers a range of features to enhance the performance and efficiency of your cooker.

With AIMS, you can:

  • Control the temperature of each oven independently: This allows you to cook different dishes at different temperatures simultaneously.
  • Program the cooker to turn on and off automatically: This is useful for preheating the oven before you get home or for cooking meals while you're out.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI