  • Hello! I am an AI chatbot trained to assist you with the Air-O-Swiss AOS 7135 Instructions For Use Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
PLEASE READ AND SAVE
ALL INSTRUCTIONS!
LISEZ ET CONSERVEZ
TOUTES LES INSTRUCTIONS!
¡POR FAVOR LEA Y
GUARDE TODAS
LAS INSTRUCCIONES!
AOS 7135
5
en
Instructions for use
6
en
Important safety instructions
• Priortousingtheappliance,readthroughthe
instructionsforcompleteuseandretaininasafeplace
forlaterreference.
• WARNING–OnlyusetheUltrasonicindoorsandwithin
thespecifiedtechnicaldata.Improperusecanbe
hazardousforthehealthandleadtocriticalinjury.
• Connecttheunitonlytoalternatingcurrent(AC)with
voltageaccordingtotheratinglabel.
• Childrencannotrecognizethehazardsassociated
withtheusageofelectricalappliances.Forthisreason,
alwayssupervisechildrenwhentheyarenearthe
humidifier(image1).
• Neverusetheapplianceifthereisanydamagetothe
applianceorcable(2),aftermalfunction,afterthe
appliancehasbeendropped(3)ordamagedinany
otherway.
• Repairsofelectricalappliancesareonlytobemadeby
qualifiedserviceengineers(4).Improperrepairwork
cancauseconsiderabledangertotheuser.
• Placethehumidifieronadry,levelsurface(5).
• Do not place the appliance directly on the flooror
nexttoaheatingvent(6).
• Ifthemistcomesincontactwiththefloorpriorto
evaporating,thefloorsurfacecanbecomedamaged.
Wedonotacceptanyliabilityfordamagesinthecase
ofincorrectplacementoftheunit.
• Theunitshouldbeplacedinanelevatedposition(7),
e.g.onatable,chestofdrawers,etc.
• Placeappliancewhereitisnoteasilyknockedover(8).
• Alwaysunplugwhennotinuse.
• Onlyoperatethehumidifierwhenitiscompletely
assembled.
• ALWAYSunplugbeforeremoving/filling/emptyingthe
watertank,beforecleaning/maintaining,assembling/
dismantlingofindividualpartsandbeforemovingthe
appliance.
• Donottouchthewaterinthebaseduringoperation
becauseofhighfrequencyvibrationsinthewater.
• Donotrunpowercordsundercarpets,anddonot
coverwiththrowrugs.Arrangecordsothatitwillnot
betrippedover.
• Neverpulltheplugfromtheoutletbythecableorwith
wethands.
• Donotusetheappliancewherecombustiblegasesor
vaporsarepresent.
• Donotexposetheappliancetorain,orusenearwater,
inabathroom,laundryareaorotherdamplocation.
• Thisunitmustbeusedinitsuprightposition.
• Donotallowforeignobjectstoenterventilationor
exhaustopeningasthismaycauseelectricshockor
damagetotheappliance.Donotblockairoutletsor
intakes.
• Donotpourwaterintothemistoutletoftheappliance.
• Thisappliancehasapolarizedplug(onebladeiswider
thantheother).Toreduceriskofshock,thisplugis
intendedtofitinapolarizedoutletonlyoneway.Ifthe
plugdoesnotfitfullyintheoutlet,reversetheplug.Ifit
stilldoesnotfit,contactaqualifiedelectrician.DONOT
attempttodefeatthissafetyfeature.
• Aloosefitbetweentheplug(receptacle)andthe
ACoutletmaycauseoverheatingandadistortion
oftheplug.Contactaqualifiedelectriciantoreplace
looseorwornreceptacles.
• Donotsit,standorplaceanyheavyobjectsonthe
appliance.
• Donotsubmergethemainbodyinwaterorother
liquids.
• Disconnectpowersupplybeforeservicing.
• Personswhoarenotfamiliarwiththeinstructions
foruse,aswellaschildrenandpersonsunderthe
influenceofmedication,alcohol,ordrugsarenot
permittedtooperatetheappliance,orareonlyper
mittedtooperateitundersupervision.
• Toprotecthealth safetyandproper humidifierfunction
useonlyclean,contaminationfree,cold,freshtapwa
terinyourhumidifier.Ifyourwatersourceiscontam
inatedorifyouareuncertainofitssafetyusedistilled
water.Inaddition,itisadvisedtoclean and maintain
your humidifierinatimelymanneras instructed in
this manual.
• Theuseofwateradditives,suchasethereal/essential
oils,fragrances,eucalyptus,waterconditionersetc.,
damagesthetankmaterialandasaconsequence
thewholeunit.Anyuseofsuchadditiveswillvoidthe
manufacturer’swarranty.
• Remark:Neitherhumansnoranimalscanhearthehigh
frequencyvibrations.
PLEASE READ AND SAVE ALL THESE INSTRUCTIONS!
8
en
Foreword
Congratulations on choosing the Ultrasonic humidifier
7135!
Didyouknowthatdryroomair:
• Causesthemembranesinyourrespiratorysystemto
dryout,andalsocauseschappedlipsandstinging
eyes?
• Encouragesinfectionsandillnessesofrespiratory
system?
• Causesweariness,tirednessandpoorconcentration?
• Stresseshouseholdpetsandhouseplants?
• Encouragestheformationofdustandtheelectrostatic
chargingoftextilesmadeofsyntheticfibers,carpets
andplasticflooring?
• Damagesfurnishingsmadeofwoodandparquet?
• Detunesmusicalinstruments?
General information
Acomfortableatmosphereindoorsisreachedwithare
lativehumiditylevelbetween40and 60%.Yourhumidi
fier automatically controls the humidity level according
todesiredsetting.Iftheairistoodry,thehumidifierwill
automaticallyswitchon.Assoonasthedesiredhumidity
levelisreached,itwillswitchoff.
Unpacking
• Carefullyremovethehumidifierfromthebox.Place
yourhandsunderneaththeproducttopullitoutofthe
box(10).
• Warning:Donottaketheunitoutoftheboxbypulling
uponthetankhandlebasemayfallandwillbeda
maged(11).
• Warning:Themistoutletispackedinaredbaginside
theboxinsert.Makesurethatyouremovethemist
outletfromthepackaging(12).
• Removetheplasticbagfromthehumidifier.
• Observetheinformationgivenontheratingplateabout
thevoltage.
• Usetheoriginalpackagingforstoringtheapplianceif
youdonotusethehumidifierallyearround.
10
11
12
9
en
Setting up
Findingtheideallocationforyourunit:
• Donotplacethehumidifierdirectlynexttoaheating
ventoronafloorwithfloorheating.Themoistureof
themistcandamagethefloorsurface(6)(seeSafety
Instructions).
• Theunitshouldbeplacedinanelevatedposition(7),
e.g.onatable,chest,etc.atleast3ftoffthefloor.
• Themistoutletmustnotbepointeddirectlyatplants,
furniture,orotherobjects(13).Keepdistanceofat
least20inches(50cm).
• Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(14).Theresinhastoabsorb
watertoreachmaximumperformance.Ifitissoakedin
thetank,makesuretoexchangethewaterandempty
thewaterfromthebasebeforeusingthehumidifier.
• Onaveragethedemineralizationcartridgeshould
bereplacedevery2–3monthsdependingonyour
waterhardness.Someareasmayneedtoreplacethe
cartridgesooner,somemaylastlonger.Thecartridge
mustbeexchangedatthelatestafter6monthsorthe
unitdoesnotreachitsfullperformanceanymore.
 See«Replacementofthedemineralizationcartridge».
• Readtheinstructionsunder«FillingtheTank»for
addingwaterinthehumidifier(15and16).
• Placethewatertankontothebase.
• Inserttheplugintothesocketandswitchonthe
applianceusingtheon/offbutton(19).
• About10to15minutesafteritisswitchedonthe
devicewillreachitsfulloutputlevel.
• Makesurethatthecableisnotpinchedanywhere(9).
Donotoperatethehumidifierifthecableisdamaged
(2).
Membrane
Controlpanel
Airinlet
Mistoutlet(rotating)
Demineralizationcartridge
Watertank
Evaporationchamber
Brush
Waterbase
Powerplug
Waterlevelsensor
Mainbody
Description of the appliance
Watertankcap
HydroCell
24 h
14
13
10
en
17
18
16
15
Filling the tank
Always unplug the unit before removing the
watertank.Donottouchthewaterinthebase
duringoperation!
Toprotecthealth safetyand proper humidi-
fierfunctionuseonlyclean,contaminationfree,
cold,freshtapwaterinyourhumidifier.Ifyour
watersourceiscontaminatedorifyouareuncertainofits
safetyusedistilledwater.
Do not operate the humidifier when the water tank is
empty!Whenthewaterreachestheminimumlevel,theunit
switchesoffthenebulizerfunctionautomatically.Thered
lightcomesonindicatingtankisempty.
•Removethewatertankfromthebaseandunscrewthe
watertankcap(15).Caution:themistoutletisloose!
• Makesurethatnoforeignobjectsareinthewater
tank.
• Fillthetankwithclean,coldwaterfromthetap(16).
Closethecapofthewatertanksecurely,placethe
watertankontothebase(17).Thewaterisnow
runningfromthetankintothebase.
• Donotpourwaterintothemistoutletoftheappliance
(18).
• Inserttheplugintothesocketandswitchonthe
applianceusingtheon/offbutton(19).Theredempty
indicatorlightmaystayilluminatedforsomeseconds
untilthebaseisfilledwithwater.
Do not use additives
Water additives (ethereal/essential oils, fragrances,
eucalyptus, water conditioners, etc.) must not be used!
Evenasmallamountcancausecracksinthematerial.The
materialisn’tmadefortheuseofsuchadditives.Onedrop
isenoughtodamagethetankandasaconsequencethe
unit.Anyuseofsuchadditiveswillvoidthemanufacturer’s
warranty.
19
11
en
C) Timer
Using button C, the operation time can be set adjusta
blebetween 1and9 hours orco(continious operation).
Symbol Gshowstheoperatingperiodthathasbeenset
(1h/2h/3h/4h/5h/6h/7h/8h/9h/co).Thedisplaywillautomat
icallyshowthecurrentvalueafterafewseconds.
D) Mist output (regulating mist output)
The mist output can be regulated by pressing button
Dseveral times. If thered bars aredisplayed,youhave
selectedthehighestlevelofmistoutput(symbol H).
E) Operation with water pre-heating
(warm mist)
ButtonEisusedforswitchingthepreheatingonandoff
(symbol Ilightsup).Asaresult,thewaterispreheated
toatemperature of 176°F(80°C)beforeentering the
nebulizerspace.Ittakesapprox.10to15minutesforthe
waterinthebasetowarmup.Themistnow leavesthe
humidifieratapleasanttemperatureof104°F(40°C).The
advantageofthisisthattheroomtemperaturedoesnot
dropand,in addition, it significantlyimproves thewater
qualitymaintenance.
F) Automatic mode and Sleep mode
Theautomaticandsleepmodescanbeactivatedbypres
singbuttonF.Bypressingthebuttononce,theautomatic
functionisswitchedon(symbol Jappearsonthedisplay),
maintainingtheoptimumhumiditysubjecttothetempera
ture.Controltakesplacebymeansofoutputquantityand
presettargetvalue. If the sleep function is switchedon
(thesymbol Kappearsonthedisplay),thetargethumidity
is60%;theoperationtimeisautomaticallysetat8hours;
theheatingisswitchedon.Inaddition,theoutputquantityis
alsocontrolledsubjecttothedifferencebetweenthetarget
valueandtheactualvalue.
TheTimercannotbechangedineithermode.Ifotherbut
tonsarepressed,theunitwillnolongerbeinautoorsleep
mode.
A) On / Off button
YoucanswitchtheunitonoroffbypressingbuttonA.This
buttonisalsousedtoresetthecleaningindicatorlight(by
holdingdown).
B) Hygrostat (setting the humidity level)
By pressing button B you can set the desired humidity
level in %. A relative humidity between 40% and 60%
isrecommended.Theaccuracyofmeasurementis+/5%.
Theunitwillswitchoffwhenthemoisturelevelexceedsthe
desiredsetting.Thedevicedoesnotswitchoffifthedis
playissetto«Co»(continuousoperation).Duringselection
thetargetvalueisdisplayed.Thedisplaywillautomatically
showthecurrentvalueafterafewseconds.
Operation 7135 G) Timer Indicator
H) Mist Output Indicator
I) Pre-heating Indicator
J) Automatic Mode Indicator
K) Sleep Mode Indicator
L) Empty indicator
Thewaterleveliseasytosee,thankstothetransparent
watertank.Theappliancealsoalertsyouwhenthewater
tankisempty.Theemptyindicatorisilluminated(symbolL).
Pleasereadthechapter«Fillingthetank»formoreinforma
tion.ThesymbolLmaystayilluminatedforsomeseconds
witharefilledtankuntilthebaseisfilledwithwater.
M) Cleaning indicator
IfsymbolMand«CLEAN»appearonthedisplay,theappli
anceshouldbecleanedasrecommendedbythemanufac
turer.Thissymbolcomesonautomaticallyevery2weeks,
dependingonthelevelofuse.The display can be reset
by holding down button A until the light disappears.
A
BC
DEF
M
LG
HIKJ
12
en
ACID
22
2521
24
Cleaning/Maintenance
Always unplug the unit before removing the
watertank.Donottouchthewaterinthebase
duringoperation!
Caution – risk of electric shock and
damage of the product!
• Switchofftheapplianceandunplugitfromthesocket
beforecleaningit(20).
• Cleanthewatertankandthebaseregularly.Usewater
only,nodetergents(21).
• UseEZCalandEZCalProcustomcleaninganddesca
lingagentsonlytoremovedepositsfromthememb
raneregularly(22and23).ThereisasampleofEZCal
includedinthepackagingofyourhumidifier.Instruc
tionsforusingareonthepacket.Onlyuse1packetfor
32ozofwater.Donotchangetheratio.DoNOTrunthe
unitwhenusingEZCalandEZCalPro.Thiscancause
damagetotheproductandvoidsthewarranty.Tho
roughlyrinsethebasewithtapwaterafterusingEZCal
andEZCalProandmakesurenoEZCalandEZCalPro
residuesremainsinthebase.
23
20
26
13
en
27
Water quality maintenance
TheHydroCellkeepshumidifiersoperatingattheirhighest
levelbetweenrecommendedcleanings.Goodforapproxi
matelyonetotwomonths,dependingonthewaterquality,
theHydroCellensuresthehumidifier’sfunctionalitywhile
providing fresh humidification performance. It starts to
workassoonasitcomesintocontactwithwater,even
iftheunitisturnedoff.TheHydroCellshouldbechanged
everyonetotwomonths*.Lookatpicture27/28forthepo
sitionoftheHydroCellinthewatertankoftheunit.Switch
offtheunitfirst.Contactyourlocalretailerorcheckour
websitewww.airoswiss.netforreorderinformation.
*Dependingonthewaterquality.
28
EZCalandEZCalProaretheonlyrecommended
cleaninganddescalingsolutions.DoNOT use
anyothercleaningsolutionssinceitcandamage
theproduct.Anyuseofcleaningsolutionsapart
fromEZCalandEZCalProwillvoidthewarranty.
• Makesuremainbodyisneversubmergedinwater
(24)!
• Thecleaningindicatorstillappearsonthedisplayafter
cleaning.ToresetitholddowntheON/OFFbuttonuntil
thecleanlightstopsflashing.
• Cleantheinnerpartswithasoftcloth.Donotuseany
solventsoraggressivecleaningagentstocleanthe
appliance(25).
• Onlyusethebrushtocleanthemembrane.Thisshould
bedoneonceaweek.Onlyusethesoftbristleportion
ofthebrush(26).
• Changethewaterinthetankatleastonceaweekif
waterisstandingformorethanaweek.
14
en
Replacement of the demineralization
cartridge
Always unplug the unit before removing the
watertank.Donottouchthewaterinthebase
duringoperation!
Thewatertankisequippedwithademineralizationcartridge.
This cartridgehas to be replacedevery 2 – 3 months. If
thewaterisveryhard,itmaybenecessarytoreplacethe
cartridgeearlier.Whitedustaroundthedeviceisasuresign
thatthecartridgeneedsreplacing.Pleasenotewhitedust
isnotharmful.Ifwhiteresiduestillformsaroundthedevice
afteranewcartridgehasbeeninserted,pleasemakesure
thatthewateryouareusingisuntreated.Ifthewaterflows
throughadecalcificationsystem–suchasanionexchanger
–(sodiumisaddedtoremovecalcium)inthebuildingbefore
itisusedinthehumidifier,saltcanprecipitateaswhitedust
aroundthedevice.Thedemineralizationcartridgeandorthe
granulesmustbeexchangedatthelatestafter6monthsor
theunitdoesnotreachitsfullperformanceanymore.
Option A: replace the resin
•Removethewatertankfromthebaseandunscrewthe
watertankcap(29).Caution:themistoutletisloose!
•Thedemineralizationcartridgeisattachedtothetank
cap.Unscrewthecartridgefromthecapbyturningit
counterclockwise(30).Important:doNOTdisposeof
thewatertankcap!
•Openthecartridge(31).
•Throwthecontentintothewaste(Attention!Disposed
resincanmakethefloorslippery!)(32).
•Placetheenclosedpinkstyrofoampieceinthecenter
ofthecartridge.Donotpushittothebottomasitwill
bedifficulttoremoveafterwards(33).
•Pourthecontentsofonerefillresinbagintotheplastic
cupthatisincludedwiththerefillresinpackaging(34).
•Placetheemptycartridgewiththepluginthecenter
ontotheplasticcup(35).
•Turntheplasticcupandcartridgeoverandshakeuntil
allresinisinthecartridge(36).
29
30
31 32
•Removetheplasticcupandthepinkstyrofoampiece
fromthecartridge(37)andretainforfutureuse(the
refillresinconsistsof3refillbags)(38).
•Closethecartridge(39).
•Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(42).Theresinhastoabsorb
watertoreachmaximumperformance.Ifitissoakedin
thetank,makesuretoexchangethewaterandempty
thewaterfromthebasebeforeusingthehumidifier.
•Screwthecartridgeonthewatertankcap(43).
•Screwthecartridgeonthebottomsideofthewater
tank,putthetankonthemainbody(44).
Placinggranulesinthecenterofthecartridge
allowsthemtoescapeintheunitortoclogthe
unit.Theunitwillnolongeroperateproperlyand
thegranulesneedtobecleanedoutthoroughly.
Option B: replace the whole cartridge
•Removethewatertankfromthebaseandunscrewthe
watertankcap(29).Caution:themistoutletisloose!
•Thedemineralizationcartridgeisattachedtothetank
cap.Unscrewthecartridgefromthecapbyturningit
counterclockwise(30).Important:doNOTdisposeof
thewatertankcap!
• Throwthewholecartridgeintothewaste(40).
•Unpackthenewcartridge(41).
•Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(42).Theresinhastoabsorb
watertoreachmaximumperformance.Ifitissoakedin
thetank,makesuretoexchangethewaterandempty
thewaterfromthebasebeforeusingthehumidifier.
•Screwthecartridgeonthewatertankcap(43).Close
tankcapwellandplacethetankonthemainbody
(44).
16
en
Technical data
Electricalvoltage 120V/60Hz
Powerconsumptionupto 45W/(140W*)
Humidityoutputupto 3.5gallons/24h*
Suitableforroomsupto 650sqft/60m
2
Dimensions(LxWxH) 15x8.7x13.8in
38x22x35cm
Weight(empty) 7.7lbs/3.5kg
Accessories 7531Demineralizationcartridge
HydroCellA200
 EZCalA7417
EZCalProA100
*whenusedwithpreheatingto176°F(80°C)
Storing the appliance for extended periods
Cleantheapplianceasdescribedearlierandallowtodry
thoroughly.Preferablystoretheapplianceinitsoriginalbox,
inadryplaceawayfromhightemperatures.
Legal notice
ThehumidifieriscULlisted.
Subjecttotechnicalchange.Theinstructionsforuseare
protectedbycopyright©PLASTONAG.
Accessories
Contact your local retailer or check our website www.
airoswiss.netforreorderinformation.
Customer Service
CustomerService(USA)18003360326
www.airoswiss.net
Troubleshooting
Problem Possible cause What to do
Unitdoesnotoperate Powercablenotpluggedin Pluginpowercable
Nowaterinthetank(Emptyindicatoron) Filltankwithwaterandwait10min.
Nomistoutput Unitneedscleaning DescalethewaterbaseusingEZCalandEZCalPro
Demineralizationcartridgeexhausted Replacecartridgeorgranules
Demineralizationcartridgeoverfilled Takeout2tablespoonsofgranulesandthrow
withgranules themaway
Weakmistoutput Watertemperaturetoolow Setmistoutputtomaximum,after15min.
thehumidifierwillworkproperlyagain
Mineraldepositsonmembrane CleanmembraneusingEZCalandEZCalProandbrush
Unitrunningintermittently Replacedemineralizationcartridgeorgranules
Whitedustaroundthehumidifier Demineralizationcartridgeexhausted Usedgranulesmustgoinwaste
17
en
General Humidifier Questions
Q.Why isn’t there enough moisture in my room?
A. Howoftendoyouruntheunit?Iftheunitisonlyrunat
night,thenduringthedaythemoisturelevelwilldropif
moistureisnotconstantlyaddedtotheair.
Q.Do you leave your door open or closed when the
unit is running?
A. a) Byleavingthedooropen,thisallowsmoistureto
leavetheroomandgointootherareasofthehouse.
Ifyouwouldlikethemoisturetostaywithinone
specificroomyoushouldconsiderclosingthedoor
whiletheunitisrunning.
A. b) Wood,leather,carpet,curtains,andothertypesof
fabricsoakupalotofmoisture,thusnotleavingen
oughmoisturefortheair.Ifthewindowisleftopen,
thenthisallowsmoisturetoescapetheroom.Ano
therfactorisalotoftimestheunitisplacednextto
aheatingdevice.Theideaisthattheairblowing
intotheroomwillquicklyplacemoisturearoundthe
room.Unfortunately,thisconceptdoesnotwork
becausethehotaircomingoutofaventwillsoak
upmostofthemoisture,andnoneoftheairwithin
theroomwillreceiveany.
Q.How much moisture do I need in my room?
A. Suggestedhumiditylevelsarebetween40–60%.
Q.What are the effects of too little or too much
humidity?
A. Dryaircancausedryskin,staticelectricity,outoftune
musicalinstruments,increasedlevelsofdust(dryair
causesdusttorise),damagetowoodenobjects(dry
outandeventuallycracksappear),discomfort,sick
ness,anddriesoutnasalmembranes.
Overhumidifyingtheaircancausemoldandwallpaper
topeel.
Q.Why do I need a humidifier when I can just open
my window?
A. Themoisturelevelwithintheoutsideairisnothigh
enoughtohumidifyaroom.Thecoldertheairtheless
moistureitiscapabletohold,andthemoretheairis
heatedupthepercentageofrelativehumidityislower.
Relativehumiditymeanstheamountofwatervaporin
theair,comparedtotheamounttheaircouldholdifit
wastotallysaturated.Thedifferenceishigherbetween
outsideandinsidetemperatures;morehumidification
isneededbecauseofthedryairintheroom.
Q.Where should I place my humidifier?
A. Theunitshouldbefreestandingandnotclosetoa
wall,window,door,orthermalbridgesothatairmay
circulatearoundtheunit.
Ultrasonic Frequent Questions
Q.Why does it say open/close on the demineralization
cartridge cap?
A. Thosedirectionsarethereincaseyoudecidetouse
therefilloptiontoreplacethegranules;thepurposeis
forhowtoopenandclosethecap.Ifyoudidopenthe
capbeforeplacingitinthewatertank,youwillmost
likelynoticethattherearegranulesinthewatertank
andthebaseoftheunit.Immediatelyturnofftheunit,
andemptythewateroutofthebaseandthewater
tank.Beginremovingallgranulesfrombaseandwater
tank.Usebrushtocleanaroundmembrane.
Caution:Donotdisposeofgranulesinsink!Used
granulesmustgoinwaste!
Q.I just replaced my cartridge, and the contents and
water in the base has turned a blue-green color.
A. Thissometimesoccurswhenthecartridge,oreven
thegranules,arereplaced.Thisdoesnotoccurwithall
replacementcartridgesorgranules,andisareactionof
watercontentandtheUltrasonicvibrations.Thisisnot
anindicatortoreplacethecartridge.
Q.There is no fill-line on the water tank, how far
may I fill it up?
A. Thereisnofilllineonthewatertank,anditmaybe
filledallthewaytothetop.
Q.What is the purpose of the demineralization
cartridge (DMC)?
A. TheDMCremovesmineralsfromthewatertoprevent
whitedust.Thecontentsofthecartridgeneedtobeso
akedfor24hrspriortofirstusingtheunitsothatthey
mayfullyexpandandremovemineralsfromthewater.
ThecontentsoftheDMChavealifeof2–3months.
Thecartridgemayneedtobereplacedmoreoften
dependingonwaterhardnessandhowoftentheunit
isused.AnindicationofwhentheDMCneedstobe
changedcanbewhitedustorreducedamountofmist
output.
Q.Is it ok to use distilled water with the unit?
A. Forbestresultswithyourultrasonichumidifieruse
distilledorreverseosmosiswaterandremovethe
demineralizationcartridge.
Q.I just replaced the contents of the cartridge and
now have granules everywhere.
A. First,makesuretherearenogranulesinthemiddle
ofthecartridge.Placinggranulesinthemiddleofthe
DMCallowsthemtoescapeintheunit.Immediately
turnofftheunit,andemptythewateroutofthebase
andthewatertank.Beginremovingallgranules
frombaseandwatertank.Usebrushtocleanaround
membrane.
Caution:Donotdisposeofgranulesinsink!Used
granulesmustgoinwaste!
Q. The directions tell me not to place the unit directly
on the floor, why do I have to elevate the unit?
A.Theideawiththisunitistoallowonetoforcehumidity
intotheair.Becauseofthis,thecarpetingorwoodfloor
surroundingtheunitmaybecomedamp.Iftheunitis
18
en
placedatleast3feetoffthefloor,themistwillhavethe
opportunitytoevaporatebeforehittingthefloor.
Q. Water does not go into the tank.
A.Inordertofillthetank,itmustbeturnedupsidedown.
Thecartridgeisplacedonthewatertankcap.Donot
pourwaterinthetubewhichisthemistoutlet.
Q. White dust is emitted from the unit
A.Whitedustparticlesaremineralsthatarebrokenupin
tinypiecesbytheultrasonicprocess.
Solve the problem:
•Soakthedemineralizationcartridgeinabowlofwater
foraminimumof24hours.Ifthecartridgeissoaked
inthewatertank,thewaterinthetankandthebase
needstobereplacedbeforeusingtheunit.
•Exchangethedemineralizationcartridgeafter12
monthswhenyouuseveryhardwater(forsofterwater
after23months).Nomatterhowhardyourwater
is,exchangethecartridgeattheverylatestafter6
months.
•Don’tusewaterfromapreinstalledwatersoftener,
orsodiuminsteadofcalciumwillbeemittedfromthe
unit.Usedistilledwaterinsteadandremovethedemi
neralizationcartridge.
•Forveryhardwaterareasuseonlydistilledwaterand
removethedemineralizationcartridge.
•UseReverseOsmosiswater(ROwater)insteadofdis
tilledwaterandremovethedemineralizationcartridge.
•Cleaning light is illuminated (digital models)
Switchofftheunitandunplugit.Emptythewaterin
thebase.Rinsethebasewithhot/cleanwater.Donot
submergethebase!Visuallyinspectthebasefordirt
ormineralbuildup.Ifsoftwaterisuseddecalcifying
theunitevery4weekswithEZCalissuggested.Ifhard
waterisusedtheunitshouldbedecalcifiedevery2
weeks.Donotforgettoresetthecleanlightafter
resettingtheunit.
Q.Reset cleaning light (digital models)
A. Thecleaninglightdoesnotautomaticallyreset.Hold
downthepowerbutton(buttonAininstructionmanual)
untilthelightstopsflashing.Thelightautomatically
comesonapprox.after14daysofpluggingintheunit.
Q.The hygrometer on unit reads a different humidity
level than external hygrometer.
A. Notallhygrometersarecalibratedthesame,andmost
areoffby+/5%.Plusthehumiditylevelisnotthe
sameinthewholeroom.Theaircirculationisdifferent
ineverycorneroftheroom.Theunitshouldnotbe
placednearaheatingventoraradiatorastheheatwill
absorballofthemoisture.
Q.Humidity level is not changing or does not reach
the desired humidity level.
A. Ifthewatertankneedsrefillingmorethanonceper
day,theunitisworkingproperlyandtheclimaticcon
ditionintheroomhasaninfluenceonthehumidity.
Reasons for low humidity level:
•aircirculationisveryhigh(airisfullyexchangedse
veraltimesperday–thehumidifierneedstostartsits
workfromscratch)
•insulationofhome(seeaircirculation)
•openspacewithhighceilings(notonlythefootageof
theroomcountsbutalsotheheight)–highrisebuil
dingsrequiremorehumidification.
•openwindows–workssimilartoaircirculation(ifitis
verycoldoutsidedon’topenthewindowmorethan2
timesperdayfor3minutes)
•bigdifferencebetweenoutsidetemperatureandinside
temperature–thecoldertheairthelessmoistureit
iscapabletoholdandthemoretheairisheatedup
theloweristhepercentageofrelativehumidity(=the
amountofwatervaporintheair,comparedtothe
amounttheaircouldholdifitwastotallysaturated)
•positionoftheunitifitisplacedclosetoadoor,win
doworairvent.Thisincreasestheaircirculation.
Q.Tank is leaking
A. Checkifthereareanyhairlinecracks.Droppedunitsor
watertanksthatarecrackedwillnotbecoveredunder
thewarranty.Pleasecontacttheretailertheunitwas
purchasedfromincaseyourunitarrivesdamaged.
Q.Placing the face in the mist
A. Itisnotrecommendedthatanybodyplacestheirface
inthemist.Itisanelectricalproductandshouldnotbe
playedwith.
Q.No mist / unit is not working / empty indicator
keeps flashing
A. Fillupthewatertank.Checkifwaterisflowingthrough
thedemineralizationcartridge(attachedtothewater
tankcap).Ifthewatertankisfullbutthereisonlylittle
waterinthebaseitindicatesthatthewaterisnow
flowingthroughthedemineralizationcartridge.
•Waitfor15minutestoallowthemisttocomeoutof
theunit.
•Iftheunitisnotworkingandtheemptylightisnotflas
hingyoumighthavesetthedesiredhumiditytoolow
andthecurrenthumiditylevelintheroomishigher.
Thatiswhytheunitswitchesoffautomatically.
•Iftheemptyindicatorkeepsflashingandthetankis
full,thewaterisnotflowingthroughthecartridge.
Exchangethecartridgeorthegranulesinthecartridge
after23months,inareaswithhardwaterexchange
thecartridgeafter12months.However,thedemi
neralizationcartridgeandorthegranulesmustbe
exchangedatthelatestafter6monthsortheunitdoes
notreachitsfullperformanceanymore
•Ifthegranulesarenew,seethefollowinginstructions:
•Makesurethecartridgeand/orgranulesweresoaked
for24hours,drygranulestakeevenlongerforwater
tofilterthroughthecartridgeandintothebase.Next,
pleaseremove2tablespoonsofgranulesfromthe
cartridge,andthrowthemaway.Whentherearetoo
manygranulesinthecartridgeitdoesnotallowwater
toflowfromthetanktothebase.
19
en
Q.Water tank cap is too tight to unscrew
A. Thiscouldbeacauseoftheairpressurewithinthe
watertank.Depressthespringonthebottomofthe
watertankcaptoreleaseairfromthewatertank.
Continuetodothisuntilyouareabletounscrewthe
watertankcap.
Q.Unit is running intermittently.
A. Howlonghasitbeensincethecontentsofthe
cartridgewerereplaced?If23monthshavepassed,
itistimetoreplacethecontentsofthecartridge.
Howeverthedemineralizationcartridgeandorthe
granulesmustbeexchangedatthelatestafter6
monthsortheunitdoesnotreachitsfullperformance
anymore.
•Ifthecontentsofthecartridgewerejustreplacedthere
areprobablytoomanygranulesinthecartridge.Re
move2tablespoonsofgranulesfromthecartridge.
Accessories
Q.Do I need to keep any parts before I replace the
demineralization cartridge?
A. Yes,alwayskeepthewatertankcap(thisisthepiece
thatattachesthedemineralizationcartridgetothe
watertank).
Q.What is the Hydro Cell and how long is it good for?
A.TheHydroCellkeepshumidifiersoperatingattheir
highestlevelbetweenrecommendedcleanings*.Good
forapproximatelyonetotwomonths,dependingonthe
waterquality,theHydroCellensuresthehumidifier’s
functionalitywhileprovidingfreshhumidification
performance.Itneedstobereplacedeveryonetotwo
months*.
*Dependingonthewaterquality.
Q.Placement of the Hydro Cell
A.Pleaseseepicture27/28forinstructions.
Q.What is EZCal and EZCal Pro?
A. ThereisasamplepacketofEZCalincludedinthe
packagingofyourhumidifier.EZCalandEZCalProare
usedforcleaninganddescalinganyofthehumidifiers
andcleansmineralbuildup.EZCalandEZCalProare
theonlyrecommendedcleaninganddescalingsolu
tions.DoNOTuseanyothercleaningsolutionssinceit
candamagetheproduct.Anyuseofcleaningsolutions
apartfromEZCalandEZCalProwillvoidthewarranty.
Instructionsforusingareonthepacket.Onlyuse1pa
cketfor32ozofwater.Donotchangetheratio.Itcan
alsobeusedforotherhumidifierbrands.Thoroughly
rinsethebasewithtapwaterandmakesurenoEZCal
andEZCalProresiduesremainsinthebase!EZCaland
EZCalProareavailableatselectedretailstoresand
onlinewww.airoswiss.net.