Altronix AL642ULADA is an effective voltage regulated remote NAC Power Extender, designed to provide NAC expansion and auxiliary power to system accessories. It features four Class A/B outputs, two Class A/B FACP inputs, two NC dry contact trigger inputs, four Class A/B indicating circuits, and two parallelable Class B outputs. It also includes one Aux. Power Output with battery backup and one without, signal circuit trouble memory, 2-wire Horn/Strobe Sync mode, Temporal Code 3 Mode, Steady Mode, Input to Output Follower Mode, and March Time.

Altronix AL642ULADA is an effective voltage regulated remote NAC Power Extender, designed to provide NAC expansion and auxiliary power to system accessories. It features four Class A/B outputs, two Class A/B FACP inputs, two NC dry contact trigger inputs, four Class A/B indicating circuits, and two parallelable Class B outputs. It also includes one Aux. Power Output with battery backup and one without, signal circuit trouble memory, 2-wire Horn/Strobe Sync mode, Temporal Code 3 Mode, Steady Mode, Input to Output Follower Mode, and March Time.

•24VDCrated@6.5ampmax.
•
Four(4)ClassAorfour(4)ClassBoutputs.
•Two(2)ClassAortwo(2)ClassBFACPinputs.
•Two(2)NCdrycontacttriggerinputs.
•Four(4)ClassAorfour(4)ClassB
indicatingcircuits.
•Two(2)ClassBoutputsmaybeparalleledformore
poweronanindicatingcircuit.
•One(1)Aux.PowerOutput@1ampsupplycurrent
(w/batterybackup).
•One(1)Aux.PowerOutput@1ampsupplycurrent
(w/obatterybackup).
•SignalCircuitTroubleMemory-facilitatesquickly
locatingintermittentsystemtroubleandeliminates
costlyandunnecessaryservicecalls.LEDsindicatea
priorfault(short,open,ground)hasoccurredonone
ormoresignalingcircuitoutputs.
•2-wireHorn/StrobeSyncmodeallowsaudible
notificationappliances(Horns)tobesilencedwhile
visualnotificationappliances(Strobes)continue
tooperate.
•Horn/Strobesyncprotocolsinclude:Gentex®,
SystemSensor®,Faraday,Amseco.
•TemporalCode3Mode.
•SteadyMode.
•InputtoOutputFollowerMode(maintains
synchronizationofnotificationappliancecircuits).
•MarchTime.
•Compatiblewith24VDCfirepanels.
•Groundfaultdetection.
•Input115VAC.
•ACfailsupervision(form“C”contacts).
•Lowbatterysupervision(form“C”contacts).
•Batterypresencesupervision(form“C”contacts).
•Powersupply,logicboard,redenclosure,camlock,
transformer&batteryleads.
•Enclosure:
- Combinationknockoutsre1/2”and3/4”
- Accommodatesuptotwo(2)
12VDC/12AHbatteries.
AL642ULADAweight:
Productweight:13.7lbs.
Shippingweight:18.05lbs.
AL642ULADA
NAC Power Extenders
Rev.AL642ULADA_A27K
Overview
Specifications
Agency Approvals
TheAL642ULADAareextremelycosteffectivevoltageregulatedremoteNAC
PowerExtenders.Theymaybeconnectedtoany24voltFireAlarmControl
Panel(FACP).PrimaryapplicationsincludeNotificationApplianceCircuit(NAC)
expansion(supportsADArequirements)andwillprovideauxiliarypowertosup-
portsystemaccessories.
ULListedControlUnitsandAccessories
forFireAlarmSystems(UL864),
FactoryMutualApproved.
NYCDepartmentofBuildingsApproved.
CaliforniaStateFireMarshalApproved.
Altronix Corp. - 140 58th Street, Brooklyn, NY 11220 • 718-567-8181 • 888-258-7669 • altronix.com
Enclosure Dimensions
18”Hx14.5”Wx4.625”D
18"
18"
14.5"
14.5"
4.5"
4.5"
4.5"
4.5"
4.5"
1.25"
1.5"
4.0"6.5"1.5"
1.25"
1.5"
4.0"
10.0"
1.25"
2.75"
7.25"
1.0"
1.5"
1.0"
1.0"
1.0"
1.25"
2.75"
1.5"
10"
  • Page 1 1
  • Page 2 2

Altronix AL642ULADA Datasheet

Category
Power adapters & inverters
Type
Datasheet

Altronix AL642ULADA is an effective voltage regulated remote NAC Power Extender, designed to provide NAC expansion and auxiliary power to system accessories. It features four Class A/B outputs, two Class A/B FACP inputs, two NC dry contact trigger inputs, four Class A/B indicating circuits, and two parallelable Class B outputs. It also includes one Aux. Power Output with battery backup and one without, signal circuit trouble memory, 2-wire Horn/Strobe Sync mode, Temporal Code 3 Mode, Steady Mode, Input to Output Follower Mode, and March Time.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI