Pelco PP100 Parapet Adapter Mount Installation guide

Type
Installation guide
Important Safety Instructions
Prior to installation and use of this product, the following warnings should be observed.
1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2. Installation shall be done in accordance with all local and national electrical and mechanical codes utilizing only approved materials.
3. Use only installation methods and materials capable of supporting four times the maximum specified load.
4. Use stainless steel hardware to fasten the mount to outdoor surfaces.
5. To prevent damage from water leakage when installing a mount outdoors on a roof or wall, apply sealant around the bolt holes between the mount and
mounting surface.
The product and/or manual may bear the following marks:
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.
Description
Pelco’s PP100 parapet adapter mount has been engineered to eliminate the expense and hazard of installing and servicing surveillance accessory equipment
mounted on parapets. The PP100 is for use with Pelco’s EWM (Esprit
©
), PSWM (PS20 Scanner), and WM200 wall mounts.
The PP100 mounts on the inside of a parapet that is at least 18 inches (45.72 cm) high. The mount rotates a full 360 degrees, allowing the equipment to be
installed and serviced safely from the rooftop. The mount’s unique design allows it to be positioned anywhere on the parapet, including corners. This
adapter mount will support up to 175 pounds (78.75 kg).
The PP100’s design allows for convenient wiring installation, including feedthrough for a 37-pin connector.
Parts List
The PP100 parapet adapter mount kit contains the following items:
User Supplied Parts
Sixteen fasteners to secure the PP100 to the parapet wall (such as lag screws or concrete fasteners) are not supplied. At a minimum, 1/4-inch diameter
fasteners are recommended.
Qty Description
1 PP100 parapet adapter
1 Flange and tube assembly
2 Wall mounting brackets (1 upper and 1 lower with strap)
2 Threaded U-bolts, 3/8-18 x 3-inch I.D. with flat washers and nuts
1 Adapter mounting hardware
4 Hex nuts, 5/16-18
4 Split lock washers, 5/16
4 Hex screws, 5/16-18 x 1-inch
INSTALLATION
PP100 Parapet Adapter Mount
C245M-D (9/10)
Installation
Refer to Figure 1 to perform the following steps:
1. Slip the upper wall mounting bracket onto the tube assembly. Do not tighten the upper mounting bracket U-bolt at this time.
2. Install the lower mounting bracket:
a. Slip the lower mounting bracket with the strap (attached to the adapter) onto the tube assembly.
b. Seat the bottom of the tube assembly against the lower mounting bracket.
c. Tighten the lower mounting bracket U-bolt until it is snug (do not overtighten).
3. Hold the PP100 adapter mount against the parapet, and position it as far down as possible so the 6-inch flange clears the top of the parapet by
1to2inches.
4. Slide the upper mounting bracket up to the edge of the parapet or as close to the edge as practical.
5. Tighten the upper mounting bracket U-bolt until snug (do not overtighten), and then mark the drill pattern through the mounting holes on both brackets.
6. Drill the mounting holes and insert 16 fasteners (not supplied) to secure the mount to the parapet.
7. After the PP100 adapter mount is attached securely to the parapet, loosen the two U-bolts so the tube can rotate freely.
8. Attach the mount for the equipment (for example, WM2000 or other mount) to the flange on the PP100 adapter mount, and then install the equipment
using the four hex screws, hex nuts, and split lock washers (supplied).
9. Rotate the equipment over the parapet and lock securely into position by tightening the two U-bolts.
NOTE: When service of equipment is required, simply loosen the two U-bolts and rotate the equipment for easy accessibility.
Figure 1. PP100 Installation
ì
Flange
î=
Tube Assembly
ï
Upper Wall Mounting Bracket
ñ
Lower Wall Mounting Bracket
ó
Threaded U-Bolts
r
16 Fasteners
Specifications
PP100 Parapet adapter mount for use with EWM (Esprit
©
), PSWM (PS20 Scanner), and WM200 wall mount; position
equipment anywhere on parapet, including corners; minimum parapet height 18 inches (45.72 cm).
Positioning Adjustment Unlimited 360°
Extension Varies with wall mount used (usually 24 inches, including wall mount)
Suggested Mounting Method Secure to parapet with 16 suitable fasteners (minimum 1/4-inch diameter recommended, not supplied)
Maximum Load 175 lb (78.75 kg); when using WM2000, maximum load is 75 lb (33.75 kg)
Cable Access 2-inch diameter feedthrough provided
Adapter Mounting Four 5/16-inch hex screws, hex nuts, and split lock washers (supplied)
Compatible Wall Mount WM2000 (can be used with the PA2000 or PA2010 pan/tilt adapters on the AH2000 adjustable head)
Construction Aluminum
Finish Polyester powder coat
Weight 10 lb (4.50 kg)
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.
0.50
(1.27)
4.75 (12.06) B. C.
1.00 x 0.375, 4X
(2.54 x 0.95)
Ø 0.44, 16X
(Ø 1.11)
Ø 6.00
(Ø 15.24)
Ø 3.50
(Ø 8.89)
7.25
(18.42)
24.25
(56.52)
2.81
(7.14)
TYP
5.00
(12.70)
TYP
4.42
(11.23)
15.00
(38.10)
3.31
(8.41)
TYP
6.00
(15.24)
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in
material or workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
Five years:
Fiber optic products
Unshielded Twisted Pair (UTP) transmission products
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and
MC3651H-2X camera models
Three years:
Pelco-designed fixed network cameras and network dome cameras with
Sarix
technology.
Pelco-branded fixed camera models (CCC1390H Series, C10DN Series,
C10CH Series, and IP3701H Series)
EH1500 Series enclosures
Spectra
®
IV products (including Spectra IV IP)
Camclosure
®
Series (IS, ICS, IP) integrated camera systems
DX Series digital video recorders (except DX9000 Series which is covered
for a period of one year), DVR5100 Series digital video recorders, Digital
Sentry
®
Series hardware products, DVX Series digital video recorders, and
NVR300 Series network video recorders
Endura
®
Series distributed network-based video products
Genex
®
Series products (multiplexers, server, and keyboard)
PMCL200/300/400 Series LCD monitors
PMCL5xx Series FHD monitors
Two years:
Standard varifocal, fixed focal, and motorized zoom lenses
DF5/DF8 Series fixed dome products
Legacy
®
Series integrated positioning systems
Spectra III
, Spectra Mini, Spectra Mini IP, Esprit
®
, ExSite
®
, and PS20
scanners, including when used in continuous motion applications.
Esprit Ti and TI2500 Series thermal imaging products
Esprit and WW5700 Series window wiper (excluding wiper blades).
CM6700/CM6800/CM9700 Series matrix
Digital Light Processing (DLP
®
) displays (except lamp and color wheel). The
lamp and color wheel will be covered for a period of 90 days. The air filter is
not covered under warranty.
Intelli-M
®
eIDC controllers
One year:
Video cassette recorders (VCRs), except video heads. Video heads will be
covered for a period of six months.
•Six months:
All pan and tilts, scanners, or preset lenses used in continuous motion
applications (preset scan, tour, and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of
Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid
to a Pelco designated location. Repairs made necessary by reason of misuse,
alteration, normal wear, or accident are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss
resulting from the specific use or application made of the Products. Pelco’s liability
for any claim, whether based on breach of contract, negligence, infringement of
any rights of any party or product liability, relating to the Products shall not exceed
the price paid by the Dealer to Pelco for such Products. In no event will Pelco be
liable for any special, incidental, or consequential damages (including loss of use,
loss of profit, and claims of third parties) however caused, whether by the
negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may
also have additional rights, which are subject to variation from state to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the
following information:
1. Model and serial number
2. Date of shipment, P.O. number, sales order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product that does not fall under
the warranty conditions stated above, please include a written explanation with
the product when returned.
Method of return shipment shall be the same or equal to the method by which the
item was received by Pelco.
RETURNS
To expedite parts returned for repair or credit, please call Pelco at (800) 289-9100
or (559) 292-1981 to obtain an authorization number (CA number if returned for
credit, and RA number if returned for repair) and designated return location.
All merchandise returned for credit may be subject to a 20 percent restocking and
refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned
CA or RA number and freight should be prepaid.
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC.
2-10-10
REVISION HISTORY
Manual # Date Comments
C245M 8/88 Original version.
C245M-A 8/90 Revised.
C245M-B 11/90 Revised.
C245M-C 11/94 Revised to new format. Revised Figure 2.
C245M-D 9/10 Revised installation instructions, Figure 1, and dimension drawing. Also applied new format and updated the warranty.
Pelco, the Pelco logo, and other trademarks associated with Pelco products referred to in this publication are trademarks of Pelco, Inc. or its affiliates. ©Copyright 2010, Pelco, Inc.
All other product names and services are the property of their respective companies. All rights reserved.
Product specifications and availability are subject to change without notice.
Pelco, Inc. Worldwide Headquarters 3500 Pelco Way, Clovis, California 93612 USA
USA & Canada Tel (800) 289-9100 Fax (800) 289-9150
International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120
www.pelco.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Pelco PP100 Parapet Adapter Mount Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI