Vermont Castings Resolute Acclaim Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the Vermont Castings Resolute Acclaim Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
0893
Resolute Acclaim
Cover
For use in the
United States and Canada
Do Not Discard This Manual: Retain for Future Use
2000893 0515 Rev. 31
SAFETY NOTICE: IF THIS APPLIANCE IS NOT
PROPERLY INSTALLED, OPERATED AND
MAINTAINED, A HOUSE FIRE MAY RESULT.
TO REDUCE THE RISK OF FIRE, FOLLOW
THE INSTALLATION INSTRUCTIONS. FAILURE
TO FOLLOW INSTRUCTIONS MAY RESULT
IN PROPERTY DAMAGE, BODILY INJURY OR
EVEN DEATH. CONTACT LOCAL BUILDING
OFFICIALS ABOUT RESTRICTIONS AND IN-
STALLATION INSPECTION REQUIREMENTS
IN YOUR AREA.
The French language version of this manual is available online:www.vermontcastings.com
La version française de ce manuel est disponible en ligne : www.vermontcastings.com
Resolute
®
Acclaim
Wood Burning Stove
Installation and Operating Manual
Model 2490
2
Resolute
®
Acclaim Woodburning Stove
2000893
Introduction
Thank you for choosing a Vermont Castings Resolute Acclaim.
Your stove is one of the nest available. It features high efciency, non-catalytic performance, using space-age refractory
material and the precisely calibrated delivery of air to a concentrated charcoal bed to promote secondary combustion
in a controlled environment.
If treated properly and operated according to the guidelines in this manual it will provide years of safe, dependable, and
economical heating.
The Resolute Acclaim is listed by OMNI-Test Laboratories of Portland, Oregon. The test standards are ANSI/UL-1482
and 737 for the United States and ULC S627 for Canada.
The Resolute Acclaim is listed for burning wood. Do not burn other fuels.
The Resolute Acclaim is listed and approved for installation in mobile homes only in the United States and only with use
of Vermont Castings Mobile Home Installation Kit #3249.
The Vermont Castings Resolute Acclaim is in compliance with the standards set forth by the Federal Environmental
Protection Agency, 40 CFR Part 60.532(b)(2), as stated on the permanent label attached to each stove.
In addition to directions on installation and operation, this manual includes directions on maintenance and assembly.
We recommend that you hire a professional solid fuel stove installer to install your stove, or to advise you on the instal-
lation should you attempt to install it yourself.
Save These Instructions.
Table of Contents
Specications .........................................3
Installation ..............................................4
Smoke Alarm/Safety Tips .....................17
Operation .............................................. 17
Maintenance .........................................24
Replacement Parts ...............................29
Warranty ...............................................31
Accessories
Warming Shelf
#0064 Classic Black
#1385 Biscuit
#1395 Brown Majolica
#1397 Bordeaux
#0184 Rear Heat Shield
#0246 Bottom Heat Shield
#0133 Sparkscreen
#3255 Outside Air Adapter (for 3” ducting)
#3249 Mobile Home Kit - includes: Rear and Bottom
Heat Shields, Outside Air Adapter, Ducting and Leg
Clips
#0574 Stove Surface Thermometer
#3421 Gasket Kit
#4360 Griddle Handle Kit
Proposition 65 Warning: Fuels used in gas, woodburning
or oil red appliances, and the products of combustion
of such fuels, contain chemicals known to the State
of California to cause cancer, birth defects and other
reproductive harm.
California Health & Safety Code Sec. 25249.6
3
Resolute
®
Acclaim Woodburning Stove
2000893
RESOLUTE
Acclaim
25¹⁄₂"
(648 mm)
27¹⁄₂"
(699 mm)
26"
(660 mm)
6"
(152 mm)
23"
(584 mm)
19¹⁄₂"
(495 mm)
12³⁄₄"
(324 mm)
25"
(635 mm)
21¹⁄₂"
(546 mm)
25"
(635 mm)
19"
(483 mm)
0893
Resolute Acclaim
specifications
1/01
21¹⁄₂"
(546 mm)
(Reg. Legs)
19¹⁄₂"
(495 mm)
(Short Legs)
Range of heat output ...................9,500-33,900 BTU/hr.*
EPA Emissions Rating ........................................3.4g/hr*
Efciency, HHV ..................................................... 72%**
Maximum heat output ......................... 40,000 BTU/hr.***
Area heated ................. Up to 1600 sq. ft. (148 sq m)****
Fuel size/type .........................16" (410 mm) wood splits
Fuel capacity .........................................30 lbs. (13.6 kg)
Loading ......................................................... Front or top
Chimney connector.......................6" (152 mm) diameter
Chimney ue size ....... Min. 6" (152 mm) or 8" (203 mm)
Flue exit position..........................Reversible, top or rear
Primary air ...........................................................Manual
Secondary air ....................................................... Preset
Ash handling system ...................... Removable ash pan
Glass panel............................High-temperature ceramic
Weight ..................................................425 lbs. (192 kg)
Width (leg-to-leg) ......................................26" (660 mm)
Depth (leg-to-leg) .....................................19" (480 mm)
Height to top of ue collar:
w/Regular legs ................... 27
1
2" (699 mm) top exit
.............................................25" (635 mm) rear exit
w/Short legs ....................... 25
1
2" (648 mm) top exit
.............................................23" (584 mm) rear exit
Specications
Resolute Acclaim Model 2490
*Under specic conditions used during EPA emissions
testing.
**Efciency determined by CSA B415.10.
***This value can vary depending on how the unit is oper-
ated, and the type and moisture content of the fuel used.
Figure shown is based on maximum fuel consumption
obtained under laboratory conditions and on average
efciencies.
****These values are based on operation in building
code-conforming homes under typical winter climate con-
ditions in New England. If your home is of non-standard
construction (e.g., unusually well-insulated, not insulated,
built underground, etc.) or if you live in a more severe or
more temperate climate, these gures may not apply.
Since so many variables affect performance, consult your
Vermont Castings' Authorized Dealer to determine realistic
expectations for your home.
Fig. 1 Resolute Acclaim dimensions.
DRAWINGS NOT TO SCALE
4
Resolute
®
Acclaim Woodburning Stove
2000893
Installation
SAFETY NOTICE: IF YOUR RESOLUTE ACCLAIM IS
NOT PROPERLY INSTALLED, OPERATED AND MAIN-
TAINED, A HOUSE FIRE MAY RESULT. FOR SAFETY,
FOLLOW ALL INSTALLATION, OPERATION AND MAIN-
TENANCE DIRECTIONS. CONTACT LOCAL BUILDING
OFFICIALS ABOUT RESTRICTIONS AND INSTALLA-
TION INSPECTION REQUIREMENTS IN YOUR AREA.
Before you begin an installation, review your plans to see
that:
Your stove and chimney connector will be far enough
from combustible material to meet all clearance
requirements.
The oor protector is large enough and is constructed
properly to meet all requirements.
You have all necessary permits from local authori-
ties.
Your local building ofcial is the nal authority for approv-
ing your installation as safe and determining that it meets
local and state codes.
The metal label permanently attached to the back of every
Vermont Castings stove indicates that it has been tested to
current UL and ULC standards, and gives the name of the
testing laboratory. Clearance and installation information is
also printed on the label. Local authorities generally will ac-
cept the label as evidence that, when the stove is installed
according to the information on the label and in this manual,
the installation meets codes and can be approved.
Codes vary in different areas, however. Before starting
the installation, review your plans with the local building
authority. Your local dealer can provide any additional
information needed.
For any unresolved questions about installation, refer
to the National Fire Protection Association’s publication
ANSI/NFPA 211–1988 Standard for Chimneys, Fireplaces,
Vents and Solid Fuel Burning Appliances. In Canada, the
equivalent publication is CSA CAN-B365, Installation Code
for Solid Fuel Burning Appliances and Equipment. These
standards are the basis for many national codes. They
are nationally recognized and are accepted by most local
authorities. Your local dealer or your local building ofcial
may have a copy of these regulations.
IMPORTANT: FAILURE TO FOLLOW THESE INSTALLA-
TION INSTRUCTIONS MAY RESULT IN A DANGEROUS
SITUATION, INCLUDING A CHIMNEY OR HOUSE FIRE.
FOLLOW ALL INSTRUCTIONS EXACTLY AND DO NOT
ALLOW MAKESHIFT COMPROMISES TO ENDANGER
PROPERTY AND PERSONAL SAFETY.
What Kind of Chimney to Use
Your Resolute Acclaim may be connected either to a sound
masonry chimney that meets local codes, to a relined ma-
sonry chimney that meets local codes, or to an approved
prefabricated metal chimney. Whatever kind you use, the
chimney and chimney connector must be in good condition
and kept clean.
If you use an existing masonry chimney, it must be inspect-
ed to ensure safe condition before the stove is installed.
Your local professional chimney sweep, building inspector,
or re department ofcial will be able to make the inspection
or to direct you to someone who can.
The chimney should extend at least 3’ (914 mm) above the
highest point where it passes through a roof, and at least
2’ (610 mm) higher than any portion of a building within
10’ (3m). (Fig. 2)
For proper draft and good performance, any chimney used
with a Resolute Acclaim should extend at least 16’ (5m)
above the ue collar of the stove.
Masonry Chimneys
An inspection of the chimney must conrm that it has a
lining. Do not use an unlined chimney. The chimney also
should be examined for cracks, loose mortar, other signs
of deterioration, and blockage. Repair any defects before
the chimney is used with your stove.
ST241
chimney types
12/13/99 djt
A prefabricated doube-wall
insulated chimney
A tile-lined
masonry
chimney
ST241
Fig. 3 Standard chimney types.
2’ Min.
2’ Min.
3’
Min.
0 To 10’
3’
Min.
0 To 10’
AC617
RLTSKC8
2/11/98
Reference Point
AC617
Fig. 2 The 2’-3’-10’ rule for chimneys.
5
Resolute
®
Acclaim Woodburning Stove
2000893
Unused openings in an existing masonry chimney must
be sealed with masonry to the thickness of the chimney
wall, and the chimney liner should be repaired. Openings
sealed with pie plates or wallpaper are a hazard and should
be sealed with mortar or refractory cement. In the event
of a chimney re, ames and smoke may be forced out of
these unused thimbles.
The chimney should be thoroughly cleaned before use.
A newly-built masonry chimney must conform to the stan-
dards of your local building code or, in the absence of a
local code, to a recognized national code. Masonry chim-
neys must be lined, either with code-approved masonry or
precast refractory tiles, stainless steel pipe, or a code-ap-
proved, “poured-in-place” liner. The chimney’s clean-out
door must seal tightly to help ensure a good draft.
Prefabricated Chimneys
A prefabricated metal chimney must be one tested and
listed for use with solid-fuel burning appliances to the
High-Temperature (H.T.) Chimney Standard UL-103-1985
(2100°F.) for the United States, and High Temperature
(650°C) Standard ULC S-629 for Canada.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
Chimney Size
A Resolute Acclaim is approved for venting into a masonry
chimney with a ue size of 8” x 8” (203 x 203 mm), and into
a round ue size of 8” (203 mm) or 6” (152 mm).
It may be vented into larger chimneys as well. However,
chimneys with liners larger than 8” x 12” (203 x 305 mm)
may experience rapid cooling of smoke and reduction in
draft, especially if they are located outside the home. These
large chimneys may need to be insulated or to have their
ues relined for proper stove performance.
Accessories to help make the connection between stain-
less steel chimney liners and your Resolute Acclaim are
available through your local dealer.
Chimney Connector Guidelines
A chimney connector is the double-wall or single-wall pipe
that connects the stove to the chimney. The chimney it-
self is a masonry or prefabricated structure that encloses
the ue. Chimney connectors are used only to make the
connection from the stove to the chimney. They are for
interior use only.
Double-wall connectors must be tested and listed for use
with solid-fuel burning appliances. Single-wall connectors
should be made of 24 gauge or heavier steel, and should
be 6” (152 mm) in diameter. Do not use galvanized chimney
connector; it cannot withstand the high temperatures that
can be reached by smoke and exhaust gases, and may
release toxic fumes under high heat.
If possible, do not pass the chimney connector through a
combustible wall or ceiling. If passage through a combus-
tible wall is unavoidable, refer to the recommendations
in the section following on Wall Pass-Throughs. Do not
pass the connector through an attic, a closet or any similar
concealed space. The whole chimney connector should be
exposed and accessible for inspection and cleaning.
Install the chimney connector not less than 23” (584 mm)
from the ceiling. Keep it as short and direct as possible,
with no more than two (2) 90° turns. If possible, use 45°
elbows. Slope horizontal runs of connectors upward 1/4”
per foot (20 mm per meter) going from the stove toward
the chimney. The recommended maximum length of a hori-
zontal run is 3’ (914 mm), and the total length of chimney
connector should be no longer than 8’ (2.5 m).
In cathedral ceiling installations, extend the prefabricated
chimney downward to within 8’ (2.5 m) of the stove.
SAFETY NOTE: ALWAYS WEAR GLOVES AND PRO-
TECTIVE EYEWEAR WHEN DRILLING, CUTTING OR
JOINING SECTIONS OF CHIMNEY CONNECTOR.
Double-wall Chimney Connectors
The listing for the Resolute Acclaim in the U.S. and Canada
includes use of double-wall chimney connectors that have
been tested and listed for use with solid-fuel burning ap-
pliances by a recognized testing laboratory.
Information on assembling and installing double-wall con-
nectors is provided by the manufacturer of the double-wall
pipe. Follow the manufacturer’s instructions exactly as
you assemble the connector and attach it to the stove and
chimney. Using chimneys and connectors from the same
manufacturer helps make the assembly and installation
straightforward.
NOTE: For installations using double-wall connectors,
minimum clearances must conform to the listed clear-
ances in the clearance chart on Page 12.
Single-wall Chimney Connectors
Beginning at the ue collar of the stove, assemble the
chimney connector. Insert the rst crimped end into the
stove’s ue collar, and keep each crimped end pointing
toward the stove. Using the holes in the ue collar as guides,
drill 1/8” (3mm) holes in the bottom of the rst section of
chimney connector and secure it to the ue collar with three
(3) #10 x 1/2” sheet metal screws.
Secure each joint between sections of chimney con-
nector, including telescoping joints, with at least three (3)
sheet metal screws. The predrilled holes in the top of each
section of chimney connector serve as guides when you
drill 1/8” (3 mm) holes in the bottom of the next section.
6
Resolute
®
Acclaim Woodburning Stove
2000893
Secure the chimney con-
nector to the chimney. In-
structions for various instal-
lations follow.
Be sure the installed stove
and chimney connector
are correct distances from
nearby combustible mate-
rial.
NOTE: Special slip pipes
and thimble sleeves that
form telescoping joints be-
tween sections of chimney
connector are available to
simplify installations. They
often eliminate the need to
cut individual connector sections. Consult your local dealer
about these special pieces.
Securing the Single-wall Connector
to a Prefabricated Chimney
Follow the installation instructions of the chimney manufac-
turer exactly as you install the chimney. The manufacturer
of the chimney will supply the accessories to support the
chimney, either from the roof of the house, at the ceiling of
the room where the stove is installed, or from an exterior
wall.
Special adapters are available from your local dealer to
make the connection between the prefabricated chimney
and the chimney connector. The top of such adapters attach
directly to the chimney or to the chimney’s ceiling support
package, while the bottom of the adapter is screwed to the
chimney connector.
These adapters are designed so the top end will t outside
the inner wall of the chimney, and the bottom end will t
inside the rst section of chimney connector. When as-
sembled in this way, any soot or creosote falling from the
inner walls of the chimney will stay inside the chimney
connector.
Securing the Single-wall Connector
to a Masonry Chimney
Both freestanding masonry chimneys and replace masonry
chimneys may be used for installation of your Resolute
Acclaim.
Freestanding Installations
If the chimney connector must pass through a combustible
wall to reach the chimney, follow the recommendations in
the Wall Pass-Through section that follows. The opening
through the chimney wall to the ue (the “breech”) must
be lined with either a ceramic or metal cylinder, called
the “thimble”, which is securely cemented in place. Most
chimney breeches incorporate thimbles, but the t must be
ST242
Chimney connector
12/13/99 djt
Fig. 4 The crimped end of
the connector points toward
the stove.
ST243
thinble connection
12/13/99 djt
Thimble Sleeve
Chimney
Connector
Flue
Keep
sleeve end
ush with
ue tile
ST243
Fig. 5 The thimble, made of either ceramic or metal, must be
cemented securely in place.
snug and the joint between the thimble and the chimney
wall must be cemented rmly. (Fig. 5)
A special piece called the “thimble sleeve,” slightly smaller
in diameter than standard connector and most thimbles,
will facilitate the removal of the chimney connector system
for inspection and cleaning. Thimble sleeves should be
available from your local dealer.
ST492
Resolute Acclaim
freestanding
installation
1/01
Chimney
Elbow
Slip Pipe
Standard
Connector
Flue Collar
Thimble
Flue Liner
Flue Liner
ST492
Fig. 6 Chimney connection is a freestanding installation.
To install a thimble sleeve, slide it into the breech until it is
ush with the inner ue wall. Do not extend it into the actual
ue passage, as this could interfere with the draft.
The thimble sleeve should protrude 1-2” (25-50 mm) into
the room. Use furnace cement and thin gasketing to seal
the sleeve in place in the thimble. Secure the chimney
connector to the outer end of the sleeve with sheet metal
screws.
7
Resolute
®
Acclaim Woodburning Stove
2000893
Above A Fireplace
In this installation, the chimney connector rises from the
stove, turns ninety degrees, and goes back into the replace
chimney. (Fig. 7) The liner of the replace chimney should
extend at least to the point at which the chimney connector
enters the chimney. Follow all the guidelines for installing a
chimney connector into a freestanding masonry chimney,
and pay special attention to these additional points:
If there is a combustible mantel or trim, check the stove
and chimney connector clearances. Use the necessary
combination of mantel, trim, and connector heat shields
to provide the required clearances.
Double-check connector clearance from the ceiling.
The replace damper must be closed and sealed to
prevent room air from being drawn up the ue, reducing
the draft. However, it must be possible to reopen the
damper to inspect or clean the chimney.
Wall Pass-Throughs
Whenever possible, design your installation so the con-
nector does not pass through a combustible wall. If you
are considering a wall pass-through in your installation,
check with your building inspector before you begin. Also
check with the chimney connector manufacturer for any
specic requirements.
Accessories are available for use as wall pass-throughs.
If using one of these, make sure it has been tested and
listed for use as a wall pass-through.
U.S.: In the United States, the National Fire Protection
Association (NFPA) has established guidelines for
passing chimney connectors through combustible
walls. Many building code inspectors follow these
guidelines when approving installations.
The following illustration shows one NFPA-recommended
method. All combustible material in the wall is cut away
a sufcient distance from the single-wall connector to
provide the required 12” (305 mm) clearance for the con-
nector. Any material used to close up the opening must be
noncombustible.
Three other methods are also approved by the NFPA.
These are:
Using a section of double-wall chimney with a 9” (229
mm) clearance to combustibles.
ST245
fireplace
flex connector
12/99
RESOLUTE
Acclaim
Flexible Con-
nector
Mantel Shield
Fireplace
Adpator Kit
ST245
Fig. 8 Chimney connector enters chimney through the re-
place opening.
ST244
Plymouth
fplc over mantel
12/99
RESOLUTE
Acclaim
Chimney Con-
nector Shields
*
*
Mantel
Seal the
Damper
* Check these
clearances
ST244
Fig. 7 Chimney connector enters chimney above the replace.
Through A Fireplace
If your replace opening height is at least 23” (584 mm)*,
you m
ay install a Resolute Acclaim through the opening
using a “positive connection” kit available from your local
dealer. These kits provide a secure connection between
the stove ue collar and the chimney ue. (Fig. 8) If it is
necessary to reverse the ue collar from the top exit to the
rear exit position, follow the directions on Page 10.
Fireplace installations, whether connected to the ue above
or through the replace opening, have special clearance
requirements to adjacent trim and the mantel. You’ll nd
the required safe clearances for Resolute Acclaim replace
installations on Page 11.
Floor protection requirements also apply to replace instal-
lations. Floor protection is discussed on Page 9.
8
Resolute
®
Acclaim Woodburning Stove
2000893
Placing a chimney connector pipe inside a ventilated
thimble, which is then separated from combustibles by 6”
(152 mm) of berglass insulating material.
Placing a chimney connector pipe inside a section of
9” (229 mm) diameter, solid-insulated, factory-built chim-
ney, with 2” (51 mm) of air space between the chimney
section and combustibles.
18” (457 mm) clearance
all around the pipe
Flush
Mounted
ST494a
Fig. 10 An approved wall pass-through for Canada.
ST493a
Brick pass thru
11/00
T
Wall Stud
Chimney Con-
nector
Floor Pro-
tection
ST493a
Fig. 9 An approved wall pass-through for the United States.
12” (305mm) of
Noncombustible
Material
Canada: The Canadian Standards Association has
established different guidelines. The illustration below
shows one method, in which all combustible material
in the wall is cut away to provide the required 18” (457
mm) clearance for the connector. The resulting space
must remain empty. A ush-mounted sheet metal cover
may be used on one side only. If covers must be used
on both sides, each cover must be mounted on noncom-
bustible spacers at least 1” (25 mm) clear of the wall.
Your local dealer or your local building inspector can
provide details of other approved methods of passing
a chimney connector through a combustible wall.
In Canada, this type of installation must conform to CAN/
CSA-B365, Installation Code for Solid Fuel Burning Appli-
ances and Equipment.
NOTE: Do not vent your Resolute Acclaim into a
factory-built (zero-clearance) fireplace under any
circumstances. The Resolute Acclaim has not been
specically tested and listed for this type of installa-
tion. These appliances and their chimneys are specically
designed as a unit for use as replaces. It may void the
listing or be hazardous to adapt them for any other use.
DO NOT CONNECT THE RESOLUTE ACCLAIM TO ANY
AIR DISTRIBUTION DUCT OR SYSTEM.
Floor Protection
A tremendous amount of heat radiates from the bottom
plate of your Resolute Acclaim. The oor area directly
under and around the stove will require protection from
radiant heat as well as from stray sparks or embers that
may escape the rebox.
Heat protection is provided through the use of a Vermont
Castings Bottom Heat Shield #0246. Spark and ember
protection must be provided by a oor protector constructed
with noncombustible material as specied.
Most installations will require that the bottom heat shield be
attached. Only when the stove is placed on a completely
noncombustible surface such as unpainted concrete over
earth may it be used without the heat shield.
Even when the bottom heat shield is installed, you must
provide special protection to the oor beneath. For instal-
lations with the heat shield attached, use a noncombustible
oor protector such as 1/4” non-asbestos mineral board or
equivalent, or 24 gauge sheet metal. The oor protector
may be covered with a noncombustible decorative material
if desired. Do not obstruct the space under the heater.
Protection requirements vary somewhat between the
United States and Canada as follows:
U.S. installations the oor protector is required under
the stove and must extend at least 16” from the front of
the stove (“C”, Fig. 11), and at least 6” from the sides and
rear (“D” and “E”,Fig. 11). It must also extend under the
chimney connector and 2” to either side (“F”,Fig. 11).
To meet these requirements, a oor protector must be at
least 38” wide and 42” deep.
In Canada, a noncombustible oor protector is required
under the heater also. The oor protector must extend 18”
(457 mm) to the front (“C”, Fig. 11), and 8” (203 mm) from
the sides and rear (“D” and “E”, Fig. 11).
9
Resolute
®
Acclaim Woodburning Stove
2000893
To meet these requirements, a oor protector must be at
least 42” (1067 mm) wide and 46” (1168 mm) deep.
Floor Protection for Fireplace Installation
Do not assume that your replace hearth is completely
noncombustible
Many replace hearths do not satisfy the “completely non-
combustible” requirement because the brick or concrete in
front of the replace opening is supported by heavy wood
framing as in Figure 12. Because heat passes readily
through brick or concrete, it can easily pass through to
the wood. As a result, such replace hearths can be a re
hazard and are considered a combustible oor.
For all replace installations, follow the oor protection
guidelines described above.
Keep in mind that many raised hearths will extend less than
the required clearance from the front of the heater when
it is installed. In such cases, sufcient oor protection as
described above must be added in front of the hearth to
satisfy the minimum oor protector requirement from the
front of the stove: 16" (410 mm) from the front in the United
States and 18" (457 mm) from the front in Canada.
Hearth rugs do not satisfy the requirements for oor protec-
tion as they are not re proof.
Fireplace installations also have special clearance require-
ments to the side walls, side decorative trim, and replace
mantel. Refer to the information on replace and mantel
trim shields in this section.
Keep the Stove a Safe Distance From
Surrounding Materials
Both a stove and its chimney connector radiate heat in all
directions when operating. A safe installation requires that
adequate clearance be maintained between the stove and
nearby combustible materials to ensure that such materials
do not overheat.
Clearance is the distance between either your stove or
chimney connector, and nearby walls, oors, the ceiling,
and any other xed combustible surface. Keep furnishings
and other combustible materials away from the stove as
well. In general, a distance of 48” (1220 mm) must be
maintained between the stove and moveable combustible
items such as drying clothes, furniture, newspapers, re-
wood, etc. Keeping those clearance areas empty assures
that nearby surfaces and objects will not overheat.
Safe Ways to Reduce Clearances
Your stove has special clearance requirements that have
been established after careful research, and testing to UL
and ULC standards.
Clearance requirements have been established to meet
most installation possibilities, and they involve the combi-
nation of four basic variables:
When the stove has no listed heat shield mounted on
it.
When the stove has a listed heat shield mounted on
it.
When the wall has no listed heat shield mounted on
it.
When the wall has a listed heat shield mounted on it.
In general, the greatest clearance is required when you
are placing a stove with no heat shield near a wall with no
heat shield. The least clearance is required when both the
stove and the wall have heat shields. Reducing a stove
clearance may require a listed heat shield on the chimney
connector as well.
ST247
Rear exit floor dgrm
12/14/99 djt
RESOLUTE
Acclaim
Wood framing
requires protection
from radiant heat
ST247a
Fig. 12 Supporting timbers under replace hearth are consid-
ered to be combustible
E
C
A
B
E
A
C
F
ST500
intrepid
floor protection
11/10/00
D
D
U.S. Canada
A: 38” 42” (1067 mm)
B: 42” 46” (1168 mm)
C: 16” 18” (457 mm)
D: 6” 8” (203 mm)
E: 6” 8” (203 mm)
F: 10” 10” (254 mm)
Top Exit
Rear Exit
ST500
Fig. 11 Required oor protector dimensions.
10
Resolute
®
Acclaim Woodburning Stove
2000893
Clearances may be reduced only by means approved by
the regulatory authority, or in accordance with the clear-
ances listed in this manual.
Wall Shields
Wall shields should be constructed of 24 gauge or heavier
sheet metal, or another noncombustible material such as
1/2" (13 mm) insulation board or common brick “laid on
at,” with the 3
1
2" (89 mm) side down. (Fig. 13)
Shields must be spaced out from the combustible surface 1"
(25 mm) on noncombustible spacers. The spacers should
not be directly behind the stove or chimney connector.
Air must be able to ow between the wall and the shield.
At least 50% of the bottom 1” (25 mm) of the shield should
be open and the shield must be open at the top.
When calculating clearance, always measure from the top
plate of the stove, or, from the chimney connector itself, to
the adjacent combustible surface. Do not measure from the
heat shields of the stove or connector to the combustible
surface.
Reversing the Flue Collar
Your Resolute Acclaim is shipped with the ue collar in the
top exit position. Depending on your requirements, you
may wish to reverse the ue collar and extension plate to
the rear exit position. The only tool necessary is a 7/16”
wrench.
To reverse the ue collar position:
1. Remove the four (4) fasteners that hold the collar and
extension plate. The fasteners are accessible by reach-
ing through the ue collar of the stove.
ST248
wall shield construction
12/14/99 djt
Air Flow
Stud Wall
Framing
Wall Shield
Noncombustible
spacers and
fasteners
Drywall
Air Flow
Shield
Metal Spacer
Screen
ST248
Fig. 13 Approved wall shield construction.
2. Remove the ue collar and extension plate.
3. Examine the exposed gasket; contact your Vermont
Castings Authorized Dealer if the gasket needs to be
replaced.
4. Position the extension plate and ue collar in the ap-
propriate orientation, making sure the gasket remains in
place. The notched edge of the extension plate should
be next to the griddle.
5. Secure the extension plate and ue collar with the fas-
teners removed in the rst step. Run the bolts in only
nger-tight. Adjust the t of the extension plate and/or
ue collar if necessary. Tighten all four (4) fasteners,
but do not overtighten them. Test the action of the
griddle; make any needed adjustments by loosening
the hardware, repositioning the ue collar and extension
plate, retesting the griddle action, and retightening the
hardware.
Fireplace Installations
A replace installation requires special clearance between
the side of the stove and the right and left walls, the side
of the stove and the decorative side trim on the replace
face, and the top of the stove and the mantel.
Ventilated shields (noncombustible) installed on noncom-
bustible spacers 1” (25 mm) away from the combustible
surface may be used to reduce clearances. (Fig. 14) A
mantel shield for the Resolute Acclaim must be at least 48”
(1219 mm) long, centered over the stove. Side trim shields
must extend the full length of the trim. (Fig. 15)
An unprotected mantel (“A”,Fig. 15) must have a minimum
clearance of 36" (914mm), measured from the stove’s top
plate. With a ventilated shield the clearance may safely be
reduced to 30" (762 mm). Maximum depth of the mantel
is 9" (229 mm).
Unprotected top trim (B) protruding 1
1
2" (38 mm) or less
from the face of the replace must be a minimum of 28"
(711 mm) from the stove's top surface. This clearance may
not be reduced by shielding. If top trim protrudes more
than 1
1
2" (38 mm) the mantel clearances of 36" (915 mm)
unshielded and 30" (762 mm) shielded must be used.
Side trim must have a minimum clearance of 8" (203 mm),
measured from the stove's top side edge. In this case, venti-
lat
ed shielding will not provide protection to allow clearance
reduction.
In addition, a replace installation must observe the oor
protection guidelines discussed previously.
The charts and sample installations on the following pages
list the clearances required for various installation congu-
rations of the Resolute Acclaim.
11
Resolute
®
Acclaim Woodburning Stove
2000893
1" (25mm)
1/4" (6mm)
ST501
mantel and
trim shield
11/10/00 djt
Mantel
Spacer
Shield
ST501
Fig. 14 A custom-formed mantel shield.
ST253b
Resolute Acclaim
trim clearances
1/25/01 djt
CC
A
B
Fireplace Mantel and Trim Clearances
Measured from the stove top and sides
Protected Unprotected
A. Mantel 30” (762 mm) 36” (914 mm)
B. Top Trim 28” (711 mm) 28” (711 mm)
C. Side Trim 8” (203 mm) 8” (203 mm)
ST253b
Fig. 15 Maintain clearances to combustible components of
the mantelpiece.
12
Resolute
®
Acclaim Woodburning Stove
2000893
(A) 15” (B) 24” (C) 15” (D) 8” (E) 13” (F) 8”
(380 mm) (610 mm) (380 mm) (203 mm) (330 mm) (203 mm)
(G) 15” (H) 24” (I) 15” (J) 8” (K) 13” (L) 8”
(380 mm) (610 mm) (380 mm) (203 mm) (330 mm) (203 mm)
(M) 15” (N) 10” N/A (O) 8” (P) 7” N/A
(38 mm) (254 mm) (203 mm) (180 mm)
(Q) 15” (R) 15” (S) 15” (T) 8” (U) 9” (V) 8”
(380 mm) (380 mm) 380 mm) (203 mm) (23 mm) (203 mm)
(Q) 15” (R) 17” (S) 15” *
(380 mm) (432 mm) (380 mm)
Protected SurfaceUnprotected Surface
Corner
Installation
Corner
Installation
Parallel Installation
Parallel Installation
No heat shields
Stove Clearance
Resolute Acclaim Clearance Chart
* Clearances with double-wall connectors and protected surfaces have not been tested for the Resolute Ac-
claim.
** A distance of 48” must be maintained between the stove and moveable combustible items such as drying
clothes, furniture, rewood, etc.
1
When a rear heat shield is installed on a top exit stove, the shield insert must be attached to the shield so the
area behind the ue collar on the stove is protected.
2
Chimney connector heat shields must extend exactly 28” (710 mm) above the ue collar of the stove. No
shielding can be used on the connector above 28” (710 mm). The unshielded chimney connector above the
28” (710 mm) point will be 14” (360mm) from an unprotected wall or 8” (203 mm) from a protected wall.
3
In top exit installations, this clearance requires the use of the rear stove heat shield with the shield insert
installed.
Side Rear Corner Side Rear Corner
Top exit, rear heat
shield only
1
Rear exit, rear heat
shield only
Top exit, rear h.s.,
single-wall connector,
connector shields
1,2
Top exit, rear h.s.,
double-wall connec-
tor
1,3
Chimney Connector
Clearance
No Heat Shields 23” (580 mm) 12” (305 mm)
Chimney connector
heat shields
2
14” (360 mm) 8” (203 mm)
Double-wall connector
3
16” (410 mm) *
Front Clearance
to Combustibles** All Installations 48” (1220 mm)
13
Resolute
®
Acclaim Woodburning Stove
2000893
Stove Installed
Parallel to Wall
Stove Installed
Parallel to Wall
Stove in Corner Stove in Corner
Unprotected Surfaces Protected Surfaces
D
E
F
F
C
C
A
B
J
K
L
L
I
I
G
H
P
Q
M
N
N/A
N/A
T
U
V
V
S
S
Q
R
ST600
RESOLUTE
Acclaim
clearance diagram
1/25/01
Top Exit, No Heat Shields
Top Exit, Rear Heat Shield Only
Rear Exit, Rear Heat Shield Only
Top Exit, Rear Heat Shield and single-wall connector w/shields, or double-wall connector
ST600
14
Resolute
®
Acclaim Woodburning Stove
2000893
Minimum Wall Shield Requirements for Common Installations
H
H
H
H
D
F
A
B
E
D
ST6003
Resolute Acclaim
wall shield
01/01
C
G
A = 26” (660 mm)
B = 23” (584 mm)
C = 44” (1118 mm)
D = 36” (914 mm)
E = 11” (279 mm)
F = 43” (1092 mm)
G = 47” (1194 mm)
H = 1” (25 mm)
ST603
Fig. 18 A top exit stove with heat shields on both the stove and
chimney connector. Reduced rear and side wall clearances. The
chimney connector heat shield must be exactly 28”. Note that rear
and side wall shields meet at corner.
G
G
C
E
A
A
D
C
ST606
Resolute Acclaim
wall shield
01/01
B
F
A = 26” (660 mm)
B = 44” (1118 mm)
C = 36” (914 mm)
D = 11” (279 mm)
E = 43” (1092 mm)
F = 49” (1245 mm)
G = 1” (25 mm)
ST606
Fig. 20 A top-exit stove with reduced rear and side wall clear-
ances. Note that rear wall shield must extend completely to
corner.
E
C
D
A
B
ST605
Resolute Acclaim
wall shield
01/01
A = 26” (660 mm)
B = 44” (1118 mm)
C = 36” (914 mm)
D = 48” (1220 mm)
E = 1” (25 mm)
ST605
Fig. 19 A top-exit stove with a wall shield only no pipe or stove
heat shields). A 26” wide section of rear wall shield must be cen-
tered behind the connector.
F
F
C
D
A
A
E
C
ST607
Resolute Acclaim
wall shield
01/01
B
D
B
A = 26” (660 mm)
B = 44” (1118 mm)
C = 36” (914 mm)
D = 36” (91 4mm)
E = 5” (127 mm)
F = 1” (25 mm)
ST607
Fig. 21 A top-exit stove with reduced rear and side wall clearance.
Wall shields must meet at corner.
A
B
C
D
E
A
E
ST604
Resolute Acclaim
Wall shield
BB
01/01
F
A = 26” (660 mm)
B = 49” (1245 mm)
C = 44” (1118 mm)
D = 36” (914 mm)
E = 1” (25 mm)
F = 23” (584 mm)
ST604
Fig. 17 A top-exit stove with 90° elbow and no stove or connec-
tor heat shields. Note clearance between chimney connector
and ceiling.
A
B
ST602
Resolute Acclaim
wall shield
01/01
A = 48” (1220 mm)
B = 36” (914 mm)
ST602
Fig. 16 A rear-exit stove with reduced rear wall clearance only.
15
Resolute
®
Acclaim Woodburning Stove
2000893
Distance from the Center of the Flue Collar to the Wall in Top-Exit Installations
The information on this page is helpful in planning stove placement for top-exiting installations, particularly those instal-
lations with chimneys that pass through the ceiling. However, this is not a clearance chart. Final stove clearances must
adhere to the guidelines stated in the Clearance Chart on Page 12.
Resolute Acclaim: WITHOUT Stove and Chimney Connector Heat Shields
Unprotected Surfaces Protected Surfaces
Corner Corner
Parallel Installations Installations** Parallel Installations Installations**
Side (A) Rear (B) Corner (C) Side (D) Rear (E) Corner (F)
27
1
2" 26" 25
1
2" 20
1
2" 15" 18
1
2"
(699 mm) (660 mm) (648 mm) (521 mm) (381 mm) (470 mm)
ST608
Resolute Acclaim
flue centerline
Diagrams
1/01
*
A
B
C
*
D
E
F
* This distance, from the center of the ue collar to the front edge of the hearth, is the same for all installations on this page:
35” in the United States and 37” (940mm) in Canada.
Resolute Acclaim: WITH Stove and Chimney Connector Heat Shields
Unprotected Surfaces Protected Surfaces
Corner Corner
Parallel Installations Installations** Parallel Installations Installations**
Side (A) Rear (B) Corner (C) Side (D) Rear (E) Corner (F)
27
1
2" 17" 25
1
2" 20
1
2" 11" 18
1
2"
(699 mm) (432 mm) (648 mm) (521 mm) (279 mm) (470 mm)
ST608
ST608a
Resolute Acclaim
flue centerline
Diagrams
1/01
A
B
C
D
E
F
**To locate center of ue collar for corner installation, add 10
1
2" (270mm) to the clearance distance from stove corner to wall.
Mark off the resulting distance from the corner along both walls. Next, measure the same distance from these two points out
from the walls. These last two measurements will meet at a point representing the center of the ue collar. Refer to the dia-
grams above.
ST608a
16
Resolute
®
Acclaim Woodburning Stove
2000893
Because of their restricted air ow and heat retention characteristics, specic construction requirements and special
clearances apply to installations into alcoves. No stove or chimney connector heat shields are used in alcove installa-
tions. Bottom heat shield requirements remain the same as for other installations.
ALCOVE INSTALLATION OF THE RESOLUTE ACCLAIM IS NOT PERMITTED IN CANADA.
Alcove Installations
Construction Requirements
Showing noncombustible ceiling framing and maximum
and minimum permitted dimensions.
St504
Alcove cutaway
11/00
ST504
Fig. 22 Cutaway perspective of alcove installation.
24"
14¼"
48" Min.
11"
Min.
36"
Min.
ST505
Alcove Ceiling plan
11/00
Existings
Combustible Framing
Metal studs
support 7/16”
Durock© (or
equivalent)
ceiling
ST505
Fig. 23 Reected ceiling plan.
36"
(914mm)
Max.
48" (1219mm) Min.
ST502
Intrepid
Alcove floor plan
11/10/00 djt
7/16” Durock©
(or equivalent)
spaced 1” off
wood studs on
noncombustible
spacers
Use recommended
oor protection
ST502
Fig. 24 Floor plan. Sheetrock on front face butts to Durock©
(or equivalent) alcove lining.
65"
62" Min.
to Alcove
Ceiling
ST610
Alcove front view
01/01
Ceiling support
package extends
2" below Du-
rock© (or equiva-
lent) ceiling
1" air gap,
top, bottom,
on both sides
and back wall
ST610
NOTE: From
62" to 65" must
be covered by
a noncombusti-
ble material.
Fig. 26 Front section: 65" minimum clearance to combustibles on
front face. Combustible facing may overlap metal studs by only
1". It should not extend below the height of the noncombustible
ceiling.
ST609
Alcove side view
01/01 djt
RESOLUTE
Acclaim
Joist Shield
(supplied
by chimney
manufac-
turer)
Metal
Stud
Combustible
facing may
overlap
metal studs
by only 1”
7/16” Durock© (or
equivalent)
1” air gap top
and bottom,
on both sides
and back
wall
ST609
Fig. 25 Alcove side section.
17
Resolute
®
Acclaim Woodburning Stove
2000893
Smoke and CO Detectors Safety Tips
The use of smoke and carbon monoxide (CO) detectors
throughout the home is strongly advised, even if not re-
quired by building codes or insurance regulations. It is
a good idea to install a smoke detector in the living ar-
eas and each bedroom. Follow the smoke/CO detector
manufacture's placement and installation instructions and
maintain regularly.
You may not, however, wish to install a detector in the im-
mediate vicinity of the stove. Depending on the sensitivity
of the unit, the alarm can be set off while you are tending
the re or emptying the ashes. If you install a detector in
the same room, locate it as far away from the stove as
possible.
Conveniently locate a "Class A" re extinguisher to con-
tend with small res. Be sure the re extinguisher works
and is clearly visible. All occupants of the house should
know where it is, and how it operates. Have heavy stove
gloves available near the stove. Have special safety
accessories (e.g., Child Guard Screen) available for use
if small children will be in the home.
In the event of a stove pipe or chimney re….
• Evacuate the house immediately
• Notify the re department
• If the re isn't too threatening, closing down the stove
tight, (damper, primary air, all doors) will help to smoth-
er the re.
• Inspect your stove, stove pipe and chimney for any
damage caused by the re and correct any damage
before using your stove again.
Operation
Stove Controls
Two Controls Operate the Stove
The primary air control lever, located beneath the ashlip,
regulates how much heat the stove produces by control-
ling the amount of air received by the re. The more air
supplied, the hotter the re. (Fig. 27)
With a travel range of about 6" (159 mm), the air control
is closed when the lever is fully left. Maximum heat is
produced when the lever is fully right. It may also be set
anywhere between a “start-up” position and the high and
low extremes to achieve a desired heat output. A directional
arrow cast into the Acclaim's ash lip serves as a reminder
of the correct “open” and “closed” positions.
You will need the following tools to assemble the Ac-
claim:
• 9/16" open end wrench • safety glasses & gloves
• at head screwdriver • power drill w/ 1/8" (3 mm) bit
• stub handle phillips screwdriver
Unpack the Stove
1. Remove the shipping straps and plastic wrap.
2. Inspect the stove and contents for shipping damage
or missing parts. Immediately notify your dealer of any
damage. Do not install this stove if any damage is evi-
dent or any parts are missing.
Hardware Bag contents:
• Stove Legs, 4
• 3/8-16 x 1
1
4" hex head Leg Bolts with washers, 4
• Owner's Registration Card
• Touch-up Paint (Porcelain enamel stoves)
Install Stove Legs
Remove and discard the four large slot-head screws from
the stove bottom. Install the stove legs using the hex head
bolts from the parts bag. (Fig. 26a) Use 3/8" washers with
all four legs. Tighten the bolts rmly.
CAUTION: Overtightening can strip tapped threads.
ST466
Seville
Attach legs
Leg Bolt and
Washer
Leg Leveller
ST466
Fig. 26a Attach stove legs and leg levellers.
This wood heater has a manufactured-set minimum low
burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this
wood heater in a manner inconsistent with operating
instructions in this manual.
WARNING
18
Resolute
®
Acclaim Woodburning Stove
2000893
The damper handle is located on the right side of the
stove and controls air ow within the stove. (Fig. 27) The
damper is open when the handle is toward the rear of the
stove, and the combustion gases exit directly out the ue
collar. When the handle is pulled forward and locked, the
damper is closed, secondary combustion occurs, and the
stove operates most efciently.
The damper must be fully open or fully closed. There are
no intermediate positions for the damper handle.
Two Ways to Add Logs
and a Choice of Fire Views
Convenient top-loading of wood through the Acclaim’s
stovetop griddle supplements traditonal replace-style
loading through the front door.
The griddle simply lifts to open.
The front door employs a rotating cam and a door latch
tab to secure it. The handle points down when the door
is closed.
To open the front door, pull on the handle to release the
cam. To close it, push the door until the latch engages.
Double-check the latch by pushing lightly on the handle.
When the latch is properly secured, the door will remain
closed.
For clear re viewing, the front door features a large, self-
cleaning glass panel. The front door may be opened (or
even removed) and the optional spark screen clipped in
place for open-re viewing as well.
ST611
Res Acclaim
controls
10/1/02 djt
Flue Collar
Top Load Door/Griddle
Damper Handle
(not shown)
Griddle Handle
Glass Panel
Front Door
Primary Air Control
Front Door Handle
ST611
Fig. 27 The Resolute Acclaim controls are conveniently lo-
cated and easy to use.
Removable Andirons For Greater
Front-Loading Convenience
The andirons slip into pockets cast into the front of the
bottom grate and can be removed when loading through
the front door. (Most Acclaim owners, however, prefer the
convenience of “smokeless” top loading.)
IMPORTANT: The andirons must be in place during opera-
tion. (Fig. 28) They not only help keep the glass door panel
clear for reviewing, but they assure proper placement of
the fuel load for efcient clean-burning operation.
ST612
Resolute Acclaim
firebox
1/01
Firebricks
Secondary Air
Ports
Ash Pan
Bottom Crates
Removable
Andirons
ST612
Fig. 28 A look inside the rebox of the Resolute Acclaim.
Two Rules For Success
Burning wood is said to be more of an art than a science.
You’ll easily master the art if you start by using good, dry
fuel, and understand how the stove’s air supply system
operates.
Burn Only High-Quality Fuel
This heater is designed to burn natural wood only; do
not burn fuels other than those for which this heater was
designed.
Higher efciencies and lower emissions generally result
when burning air-dried, seasoned woods as compared to
softwoods or freshly cut hardwoods. Avoid burning “green”
wood that has not been properly seasoned. Also, do not
use construction materials or trash as fuel; the chemicals,
coatings and hardware that may be present can cause
damage to the refractory material.
The best hardwood fuels include oak, maple, beech, ash,
and hickory that has been split, stacked, and air-dried outside
under cover for at least one year. Avoid burning cordwood
that is over 2 years old as such fuel can contribute to short
burn times, backpufng and over-ring.
For areas that do not have a supply of hardwood, some
of the better softwoods that are commonly burned include
tamarack, yellow pine, white pine, Eastern red cedar, r,
and redwood. They too should be properly dried. The length
19
Resolute
®
Acclaim Woodburning Stove
2000893
of the wood should be 16” (406 mm). Use of wood shorter
than 16” may result in decreased burn times.
Wood should be stored under cover to maintain dryness.
Even for short-term storage, keep wood a safe distance
from the heater and keep it out of the areas around the
heater used for refueling and ash removal.
Use the Air Control Settings
That Work Best for You
No single control setting will t every situation. Each op-
eration will differ depending on the quality of the fuel, the
amount of heat desired, and how long you wish the re
to burn.
Control settings also depend on your particular installation’s
“draft,” or the force that moves air through the stove and up
through the chimney. Draft is affected by such things as the
length, type, and location of the chimney, local geography,
nearby obstructions, and other factors.
Too much draft may cause excessive temperatures in the
stove. On the other hand, too little draft can cause back-
pufng into the room and/or insufcient heat.
How do you know if your draft is excessively high or low?
Symptoms of too much draft include an uncontrollable burn
or a part of the stove or chimney connector glowing red.
Inadequate draft is indicated by smoke leaking into the
room through the stove or chimney connector joints.
In some newer homes that are well-insulated and weather-
tight, poor draft may result from insufcient air in the house.
In such cases it may be necessary to duct combustion air
to the stove directly from outside. In fact, in some areas,
outside combustion air is required for stove installations
in all new construction.
Your Resolute Acclaim is designed to easily incorporate
outside combustion air with a Vermont Castings Outside
Air Duct Adapter #3255 available from your local dealer.
When rst using the stove, keep track of the air control
settings. You will quickly nd that a specic setting will give
you a xed amount of heat. It may take a week or two to
determine the amount of heat and the length of burn you
should expect from various settings.
Most installations do not require a large amount of combus-
tion air, especisally if adequate draft is available. Do not
for any reason attempt to increase the ring rate of your
heater by altering the air control adjustment range outlined
in these directions.
Use the following air control settings as a starting point to
determine the best settings for your needs.
Primary Air Settings
Air Setting Air Control Position
CLOSED Fully Left
LOW Approximately 1” (25 mm) to
the right of CLOSED.
HIGH Approximately 3”(80 mm) to the
right of CLOSED, where the
lever hits the stop.
START-UP Fully Right
ST613
Resolute Accaim
air control settings
1/26/01 djt
Low
High
Start-up
Normal
Operation
Move handle down and to
the right for start-up position
Fig. 29 Variable settings for the primary air control between
the open and closed positions provide a range of heat output.
ST613
How to Build and Sustain a Wood Fire
You can load wood into your Resolute Acclaim through
either the top or front loading door. Front-loading is useful
for kindling a new re, but we recommend top loading as
the most convenient way of regularly adding several logs
at a time.
Your Resolute Acclaim may be operated with the front door
open for replace-style viewing as well as closed. Always
be certain the stove damper is open when the door is open
and always use the optional rescreen for re viewing.
Starting and Maintaining A Wood Fire
A new stove needs to be “broken in.” Since cast iron plates
expand and contract in response to temperature change,
let them adjust gradually to heating and cooling. To properly
break in your stove, follow Steps 1-3 below only for your
rst three or four res. After that, you may go on to Step 4
and normal operation of the stove.
The stove paint and cement will emit a slight odor during the
rst few res. We suggest that you provide extra ventilation
near the stove by partially opening a door or window when
the odor is present.
WARNING: Operate only with doors fully open or doors
fully closed. If doors are left partly open, gas and ame
may be drawn out of the replace stove opening, creat-
ing risks of both re and smoke.
1. Open the stove damper, and open the primary air control
fully to the Start-up position.
20
Resolute
®
Acclaim Woodburning Stove
2000893
2. Lay some crumpled newspapers in the stove. Place
six or eight pieces of dry kindling split to a nger-width
size on the paper, and on the kindling lay two or three
larger sticks of split dry wood approximately 1-2” (25-50
mm).
Do not use chemicals or uids to start the re. Do not
burn garbage or ammable uids such as gasoline,
naptha or engine oil. Also, never use gasoline-type
lantern fuel, kerosene, charcoal lighter uid, or similar
liquids to start or “freshen up” a re in this heater. Keep
all such liquids well away from the heater while it is in
use.
3. Light the newspaper and close the door. The re soon
will be well-established and you may gradually build it
up by adding a few sticks at a time of a progressively
larger size.
For your initial three or four break-in res, let the re
burn brightly for a short time, then let it die out.
NOTE: Some chimneys need to be “primed,” or warmed
up, before they will draw sufciently to start a re. To cor-
rect this situation, roll a couple of pieces of newspaper,
place them on top of the kindling and toward the back of
the stove, light them, and close the doors. This should
get the smoke moving in the right direction.
Once the draft is established, open the front door and
light the rest of the fuel from the bottom. Do not light
the main bed of fuel until the chimney begins drawing,
and repeat the procedure as often as necessary if the
initial attempt is unsuccessful.
NOTE: Continuous operation with the air control in the
start-up (fully open) position may shorten the life of the
internal castings.
4. Once the re is burning steadily, continue adding fuel
until a thick ember bed has been established on the
grate. The bed must be about 4” (102 mm) deep at
the back of the grate and about 1” (25 mm) deep at
the front, and should cover the throat opening into the
secondary combustion chamber that is located in the
center of the lower reback.
If your wood is well-seasoned, the damper may be
closed when the griddle temperature reaches 500° F
(260°C). Depending on the type of wood being burned
and its moisture content, it may take several hours to
establish and then maintain the ember base that is
required for high-efciency operation.
5. Once the ember bed is formed, prepare the stove for
high-efciency operation. Load it with fuel, rst with
smaller splits of wood and then larger ones.
Close the damper and set the primary air control lever
to the “HIGH” position. Operate the stove for 15 - 20
minutes at this maximum air setting to guarantee the
new load of fuel has fully ignited. Once the fuel is burn-
ing steadily, you may adjust the primary air supply to
provide the desired heat output.
NOTE: Effectiveness of a “top-down” method to start a re.
Smoke emissions when starting a re can be difcult to
control because the stove is not yet heated to its opti-
mum temperature. One method of reducing emissions
during a cold start-up is the use of a “top-down” kindling
procedure. In this, place larger pieces of kindling on
the bottom of the kindling pile followed by smaller and
smaller pieces as the pile is added to. Very nely split
pieces should be on the top. Light the kindling pile
with a match at the top and allow the kindling to burn
downward into the larger pieces. This reduces smoke
by slowly increasing the re size without creating an
air-starved condition.
You’ll soon nd this stove is HOT WHILE IN OPERATION!
KEEP CHILDREN, CLOTHING, AND FURNITURE AWAY.
CONTACT MAY CAUSE SKIN BURNS.
DO NOT OVERFIRE THIS HEATER. Overring can
result in permanent damage to the stove. If an exterior
part of the stove or the chimney connector glows, you are
overring.
Reloading and Reviving a Wood Fire
Reload your stove while it is still hot and there are plenty of
embers to re-kindle the re quickly. Include some smaller
pieces of wood in the new load of fuel to help the stove
regain high temperatures quickly.
Follow this procedure when you reload your stove:
Open the damper and move the primary air lever to the
“HIGH” position.
Open the front door and check the ash level on the
grates and in the ash pan. Clear excess ash from the
grates, particularly at the rear area. Level the ember
bed. Empty the ash pan if necessary.
Replace the ash pan and close the front door.
Load wood, smaller pieces rst, and close the loading
door.
ST614
Resolute Acclaim
Damper control
1/26/01 djt
Damper Control
Closed Open
ST614
Fig. 30 With the damper closed, secondary combustion takes
place and the Acclaim operates most efciently.
/