Saxby Lighting 102454 User manual

Type
User manual

Saxby Lighting 102454 is a versatile accessory that extends the functionality of compatible Saxby Lighting products. With this accessory, you can add emergency lighting, microwave sensor-activated lighting, or both to your existing Saxby Lighting fixtures. The emergency lighting function provides backup illumination during power outages, while the microwave sensor allows for automatic light activation upon movement detection. Installation is straightforward and can be completed by following the included instructions.

Saxby Lighting 102454 is a versatile accessory that extends the functionality of compatible Saxby Lighting products. With this accessory, you can add emergency lighting, microwave sensor-activated lighting, or both to your existing Saxby Lighting fixtures. The emergency lighting function provides backup illumination during power outages, while the microwave sensor allows for automatic light activation upon movement detection. Installation is straightforward and can be completed by following the included instructions.

Additional instructions
Thank you for purchasing this accessory. Please read these instructions and combine the instruction manual of the main light fitting carefully
before use to ensure safe and satisfactory operation of this accessory. Please retain these instructions for future reference.
Wiring for HeroPRO Mini CCT / HeroPRO CCT / HeroPRO XL CCT
HeroPRO CCT Accessories
101456 HeroPRO MW
102454 HeroPRO self test EM kit
101458 HeroPRO medium corridor kit
103943 HeroPRO XL corridor kit
101456 HeroPRO MW
102454 HeroPRO self test EM kit
• These Plug and Play accessories for the HeroPRO series (HeroPRO Mini CCT / HeroPRO CCT / HeroPRO XL CCT).
• HeroPRO series lamps will be extended with new functions by using with different accessories.
• Installation and Wire refer to the corresponding wiring diagram according to your existing light fitting and purchased accessories.
Warning
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with the IEE Wiring regulations and current Building egulations.
If you are in any doubt, please consult a qualified electrician.
If replacing an existing fitting, make a careful note of the connections.
1. Wiring for Standard Function 2. Wiring for Microwave Function-----Microwave Sensor Accessory
3. Wiring for Emergency Function-----Emergency Accessory
4. Wiring for Emergency function & Microwave Sensor function-----Both Accessories
BATTERY REPLACEMENT INFORMATION:
Battery Type:Life PO4
Rated Voltage:3.2V
Rated Amp Hours:1500mAh
Remove this cover to connect battery
before commissioning, then replace.
B+
B-
Model:102454
Input:220-240V AC 50/60Hz 3W Max
Tc
For use with 3.2V 1500mAh LiFeP04 Battery
Discharging Current: 60mA
Vout:3VdcMax 1.2W Max
Ta:-10ºC to 50ºC Tc:70ºC
L+
L-
E+
E-
N
L/PL
N
L/PL
Blue
Brown
nworB
eulB
INPUT
L N
OUTPUT
LN
W-
V+
G-
N
L
LED Driver
Model:
Input:220-240Vac 50/60Hz 0.15A Max
Output:70-100VDC 180mA(Max)
Tc
Prated:18.0W Max PF≥0.70
U-out:200VDC Ta:40°C TC:80°C
18W/14W/9W
6K/4K/3K
SL PL
N
Brown
Blue
LIGHT FITTING SUPPLY
LIGHT FITTING
SUPPLY
nworB
eulB
INPUT
L N
OUTPUT
LN
W-
V+
G-
N
L
LED Driver
Model:
Input:220-240Vac 50/60Hz 0.15A Max
Output:70-100VDC 180mA(Max)
●Tc
Prated:18.0W Max PF≥0.70
U-out:200VDC Ta:40°C TC:80°C
18W/14W/9W
6K/4K/3K
SL PL
N
INPUT
L N
OUTPUT
LN
LIGHT FITTING SUPPLY
Brown
Blue
Microwave Sensor
BATTERY REPLACEMENT INFORMATION:
Battery Type:Life PO4
Rated Voltage:3.2V
Rated Amp Hours:1500mAh
Remove this cover to connect battery
before commissioning, then replace.
B+
B-
Model:102454
Input:220-240V AC 50/60Hz 3W Max
Tc
For use with 3.2V 1500mAh LiFeP04 Battery
Discharging Current: 60mA
Vout:3VdcMax 1.2W Max
Ta:-10ºC to 50ºC Tc:70ºC
L+
L-
E+
E-
Green lamp
W-
V+
G-
N
L
LED Driver
Model:
Input:220-240Vac 50/60Hz 0.15A Max
Output:70-100VDC 180mA(Max)
Tc
Prated:18.0W Max PF≥0.70
U-out:200VDC Ta:40°C TC:80°C
18W/14W/9W
6K/4K/3K
SL PL
N
Brown
Blue
Emergency accessory
BATTERY REPLACEMENT INFORMATION:
Battery Type:Life PO4
Rated Voltage:3.2V
Rated Amp Hours:1500mAh
Remove this cover to connect battery
before commissioning, then replace.
B+
B-
Model:102454
Input:220-240V AC 50/60Hz 3W Max
Tc
For use with 3.2V 1500mAh LiFeP04 Battery
Discharging Current: 60mA
Vout:3VdcMax 1.2W Max
Ta:-10ºC to 50ºC Tc:70ºC
N
L/PL
L+
L-
E+
E-
Green lamp
W-
V+
G-
N
L
LED Driver
Model:
Input:220-240Vac 50/60Hz 0.15A Max
Output:70-100VDC 180mA(Max)
Tc
Prated:18.0W Max PF≥0.70
U-out:200VDC Ta:40°C TC:80°C
18W/14W/9W
6K/4K/3K
SL PL
N
INPUT
L N
OUTPUT
LN
LIGHT FITTING
SUPPLY
Brown
Blue
Microwave Sensor
Emergency accessory
BATTERY REPLACEMENT INFORMATION:
Battery Type:Life PO4
Rated Voltage:3.2V
Rated Amp Hours:1500mAh
Remove this cover to connect battery
before commissioning, then replace.
B+
B-
Model:102454
Input:220-240V AC 50/60Hz 3W Max
Tc
For use with 3.2V 1500mAh LiFeP04 Battery
Discharging Current: 60mA
Vout:3VdcMax 1.2W Max
Ta:-10ºC to 50ºC Tc:70ºC
N
L/PL
L+
L-
E+
E-
Blue
Brown
BATTERY REPLACEMENT INFORMATION:
Battery Type:Life PO4
Rated Voltage:3.2V
Rated Amp Hours:1500mAh
Remove this cover to connect battery
before commissioning, then replace.
B+
B-
Model:102454
Input:220-240V AC 50/60Hz 3W Max
Tc
For use with 3.2V 1500mAh LiFeP04 Battery
Discharging Current: 60mA
Vout:3VdcMax 1.2W Max
Ta:-10ºC to 50ºC Tc:70ºC
N
L/PL
L+
L-
E+
E-
Blue
Brown
G-
V+
W-
N
L
LED Driver
Model: 101458
Input:220-240Vac 50/60Hz 0.15A Max
Output:70-100VDC 180mA(Max)
●Tc
Prated:18.0W Max PF≥0.70
U-out:200VDC Ta:40°C TC:80°C
18W/14W/9W
3K/4K/6K
Inductive signal
W-
V+
G-
N
L
LED Driver
Model:
Input:220-240Vac 50/60Hz 0.15A Max
Output:70-100VDC 180mA(Max)
Tc
Prated:18.0W Max PF≥0.70
U-out:200VDC Ta:40°C TC:80°C
18W/14W/9W
6K/4K/3K
SL PL
N
Brown
Blue
LIGHT FITTING SUPPLY
G-
V+
W-
N
L
LED Driver
Model: 101458
Input:220-240Vac 50/60Hz 0.15A Max
Output:70-100VDC 180mA(Max)
●Tc
Prated:18.0W Max PF≥0.70
U-out:200VDC Ta:40°C TC:80°C
18W/14W/9W
3K/4K/6K
Inductive signal
When you need to connect the corridor accessory,
please remove the original driver fixed on the lamp to
install the driver of the corridor accessory.
When you need to connect the corridor accessory,
please remove the original driver fixed on the lamp to
install the driver of the corridor accessory.
Installation HeroPRO Mini CCT / HeroPRO CCT / HeroPRO XL CCT
1, Undo the screw to open the battery cover and conect the battery terminal. Then refit the
battery cover and screw fix.
2, Fix the EM kit to the back of LED board in place.
3, Connect the EM kit terminal to the terminal of LED board.
4, Connect L of EM kit to PL of terminal block in back of LED board and N to N.
5, Insert the indicator light into the indicator light hole of LED board.
Installation for HeroPRO Mini CCT / HeroPRO CCT / HeroPRO XL CCT
1, Remove the SL cable on the terminal block to connect it to the L ' of the microwave sensor first,
then remove the N cable to connect it to the N of OUTPUT terminal on the microwave sensor.
2, Fix the microwave sensor to the back of the LED board in place.
3, Insert the L cable of the microwave sesor into the SL of the terminal block, and the N cable
into the N terminal of the terminal block.
4, MW settings can be adjusted either before or after the MW kit installation.
1 2
3 4
EM kit fixed in the HeroPRO Mini CCT /
HeroPRO CCT with clip
Indicator light in the HeroPRO
Mini CCT / HeroPRO CCT
EM kit fixed in the HeroPRO XL CCT with
plastic rivet
Indicator light in the HeroPRO XLCCT
12
34
5
N
L/PL
LIGHT FITTING
SUPPLY
BATTERY REPLACEMENT INFORMATION:
Battery Type:Life PO4
Rated Voltage:3.2V
Rated Amp Hours:1500mAh
Remove this cover to connect battery
before commissioning, then replace.
B+
B-
Model:102454
Input:220-240V AC 50/60Hz 3W Max
Tc
For use with 3.2V 1500mAh LiFeP04 Battery
Discharging Current: 60mA
Vout:3VdcMax 1.2W Max
Ta:-10ºC to 50ºC Tc:70ºC
L+
L-
E+
E-
Green lamp
W-
V+
G-
N
L
LED Driver
Model:
Input:220-240Vac 50/60Hz 0.15A Max
Output:70-100VDC 180mA(Max)
Tc
Prated:18.0W Max PF≥0.70
U-out:200VDC Ta:40°C TC:80°C
18W/14W/9W
6K/4K/3K
SL PL
N
Brown
Blue
Emergency accessory
6. Stepped Dim Microwave Movement Sensor Function----- Emergency Accessory----Only suitable for HeroPRO CCT / HeroPRO XL CCT
5. Stepped Dim Microwave Movement Sensor Function----Only suitable for HeroPRO CCT / HeroPRO XL CCT
To prevent electrocution switch off at the mains supply before installing or
maintaining this fitting. Ensure other persons cannot restore the electrical
supply without your knowledge.
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your local authority or
retailer for recycling advice.
DIP Switches
www.saxbylighting.com
V1 15/03/2023
EU Manufacturer: Brilliant AG,
Brilliantstrasse 1, D-27442 Gnarrenburg
UK Manufacturer: BH17 7BY
101458 HeroPRO medium corridor kit 103943 HeroPRO XL corridor kit
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.
For your safety, always switch off the power supply before cleaning.
Care and Safety
Installation in HeroPRO CCT range
1, Remove the 5 cables (L , N, W-, V+, G-) from the drive fixed on the LED board.
2, Press down the clip on the LED panel with a screwdriver to remove the drive cover fixed
on the LED board, then remove driver integrated board.
3, Installation of corridor microwave drive (corridor sensor & new driver integrated board)
and reclip the driver cover removed in step2 to the LED board in place.
4, Connect the 5 cables to the new drive (L, N, W-, V+, G-).
5, Corridor sensor settings can be adjusted either before or after corridor kit installation.
Installation in HeroPRO XL CCT range
1, Remove the 5 cables from the drive fixed on the light (L , N, W-, V+, G-).
2, Undo the screws fixed on both side to remove the original drive fixed on the light.
3, Undo the two screws fixed on the LED board to remove the microwave bracket to show the
screw holes for installing the corridor sensor.
4, Install the 103943 HeroPRO XL corridor kit (corridor sensor & new driver) into the LED board.
5, Connect the 5 cables to the new drive (L , N, W-, V+, G-).
6, Corridor sensor settings can be adjusted either before or after corridor kit installation.
12
34
5
6
Screw Hole
of corridor sensor
12
3
45
Remove
DIP Switches
DIP Switches
  • Page 1 1
  • Page 2 2

Saxby Lighting 102454 User manual

Type
User manual

Saxby Lighting 102454 is a versatile accessory that extends the functionality of compatible Saxby Lighting products. With this accessory, you can add emergency lighting, microwave sensor-activated lighting, or both to your existing Saxby Lighting fixtures. The emergency lighting function provides backup illumination during power outages, while the microwave sensor allows for automatic light activation upon movement detection. Installation is straightforward and can be completed by following the included instructions.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI