ICP DAS USA ZT-2052-IOP Quick Start

Type
Quick Start
ZigBeeWirelessPairConnection
ZT2052IOP
QuickStart
ZT2052IOPQuickStart,v1.0,2013/06/07Page1
1. Introduction
TheZT2052IOPmoduleactsasaZigBeecoordinatorthatprovides8channeldigital
inputpairconnectionfunctionwithmoduleofZT2042(4chPhotoMOSRelayOutput
and4chOpenCollector).AnembeddedI/Ochannelbindingfunctionmeansthat
thereisnoneedtouseanexternalcontroller.
ThestatusofeachZT2052IOPchanneltriggersthecorrespondingremotedigital
outputchannelsontheZT2042module.TheZT2052IOPcontinuallytransmits
updatesonthestatusofthedigitalinputchannelstotheremoteZT2042toensure
thatthedigitaloutputchannelsaresynchronized.
TheZT2052IOPalsoprovidesexternalDIPandRotaryswitchesforeasyconfiguration,
whichcanbeusedtosynchronizethedigitalsignalsinanyenvironmentwherewiring
isdifficult.
ZT
2052
IOP
ZT
2042
01
DO_0
~
DO_7
PairconnectionforaOnetoOneI/ODevice
DI_0
~
DI_7
PairconnectionforPairofMultipleI/O Devices
DI_0
~
DI_7
DO0
~
DO_7
DO0
~
DO_7
DO0
~
DO_7
ZT2052IOP
ZT2042_01
ZT2042_02
ZT2042_NN
ZT2052IOPQuickStart,v1.0,2013/06/07Page2
2. Appearance
ZT2052IOP
LEDIndicators
Ante nna
DIPSwitch
IN0
IN1
IN2
IN3
IN4
IN5
IN6
+Vs GND F.G.
PowerSupply RotarySwitch
Reserved
123456 78ON
PairNumber
PWRZigBee‐‐‐‐‐‐
 DI0DI1DI2DI3
 DI4DI5DI6DI7
ZBPI
D
ZB Channel
IN7
DI.PWR
DI.PWR
3. WireConnections
ZT2052IOP
ZT2052IOPQuickStart,v1.0,2013/06/07Page3
4. Configuration
TheDIPandRotaryswitchesshouldbeadjustedbasedonthespecificnetwork
requirements,asdescribedbelow.
RotarySwitch(LSBAddress)
A. OntheZT2052IOP,thisswitchisfixedandcannotbeadjusted.(TheZigBee
coordinatorisalwayssetto0x0000)
B. OntheZT2042,thisswitchisuse
dtodefinetheDeviceIDandNodeIDforthe
ZigBeenetwork.
RotarySwitchValue Note
ZT2052IOP 0(0x0000) Alwayssettothe‘0’position
ZT2042 1~15(0x0001~0x000F)
Canbesettoanypositionfrom‘1’to‘F’basedon
thenumberofI/Opairs
DIPSwitch(1)(MSBAddress)
A. OntheZT2042,thisswitchisusedtodefinetheMSB(MostSignificantBit)
address.
DIPSwitch(1~3)(PairNumber/Protocol,Checksum)
A. OntheZT2052IOP,theseswitchesareusedtosetthenumberofZT2042I/O
pa
irdevices.ThestatusoftheconnectiontotheZT2042devicewillbeshown
viatheredLEDindicatorontheZT2052IOPandisupdatedevery10seconds.
FormoredetailsreadingtheLEDindicators,referstoChapter6Appendix.
B. OntheZT2042,theseswitchesar
eusedtodefinetheprotocolandchecksum.
DIPSwitch1 DIPSwitch2 DIPSwitch3 Note
Reserved PairingNumber RemoteDeviceNumber
OFF OFF OFF 0(checkslave0x01)
OFF OFF ON 1(checkslave0x010x02)
…… ……
ZT2052IOP
ON ON ON 7(checkslave0x010x08)
MSBAddress Protoc ol Checksum
ZT2042
Off OFF(DCON) OFF
DIPSwitch(4)(PanID)
ThisswitchisusedtodefinethePanIDforboththeZT2052IOPandtheZT2042
andmustbesettothesamevalueonbothdevices.
DIPSwitch4 Note
OFF(0x0000)ZT2052IOP
ZT2042
ON(0x0001)
ThePanIDmustbesettothesamevalueonbothdevices.
ZT2052IOPQuickStart,v1.0,2013/06/07Page4
DIPSwitch(5~8)(RFChannel)
TheseswitchesareusedtodefinetheRFchannelusedforboththeZT2052IOP
andtheZT2042andthevaluessetforbothdevicesmustbethesame.
DIPSwitch5 DIPSwitch6 DIPSwitch7 DIPSwitch8 Note
0x08 0x04 0x02 0x01 Value
OFF OFF OFF OFF 0(2405MHz)
OFF OFF OFF ON 1(2410MHz)
…… ……
ZT2052IOP
ZT2042
ON ON ON ON F(2480MHz)
TheRFchannelmustbesettothesamevalueonbothdevices.
ZT2052IOPQuickStart,v1.0,2013/06/07Page5
5. Applications
Example1(Default:OnetoOneI/OPairconnection)
c
ZT2052IOP
NumberofI/OPairs:1
PanID:0x0000
RFChannel:0x00
DI_0
~
DI
_
7
ZT2042
DO_0
~
DO_7
Example2(Synchronizingthedifferentdigitalchannelstodifferentdevices)
ZT2052IOP
12345678ON
PairNumber
RFChannel
P
a
nID
Address
(LSB)
Address
(LSB)
RFChannel
1234 56789 101112
ON
Address(MSB )
Protocol
Checksum
P
a
nID
ZT2042_02ZT2042_01
DO_0
ZT2042 01
NumberofI/OPairs:2
PanID:0x0001
RFChannel:0x0F
ZT2052IOP
DI_0
~
DI_7
DO_1
ZT2042 02
X
X
ZT2052IOP ZT2042_01
12345678ON
PairNumber
RFChannel
PanID
Address
(LSB)
RFChannel
Address(MSB )
Protocol
PanID
Checksum
ON
1234 56789 101112
Address
(LSB)
Address
(LSB)
RFChannel
123456789 101112
ON
Address(MSB )
Protocol
Checksum
P
a
nID
ZT2052IOPQuickStart,v1.0,2013/06/07Page6
Example3(Synchronizingallofthedigitalchannelstodifferentdevices)
ZT2052IOP
12345678ON
PairNumber RFChannel
PanID
Address
(LSB)
Address
(LSB)
RFChannel
1234 56789 101112
ON
Address(MSB )
Protocol
Checksum
PanID
ZT2042_02
Address
(LSB)
RFChannel
123456789 101112
ON
Address(MSB )
Protocol
Checksum
P
a
nID
ZT2042_01
Address
(LSB)
RFChannel
1234 56789 101112
ON
Address(MSB )
Protocol
Checksum
PanID
ZT2042_04
Address
(LSB)
RFChannel
123456789 101112
ON
Address(MSB )
Protocol
Checksum
P
a
nID
ZT2042_03
NumberofI/OPairs:4
PanID:0x0000
RFChannel:0x09
ZT2042 01
ZT2052IOP
ZT2042 02
ZT2042 03
ZT2042 04
DO_0
~
DO_7
DO_0
~
DO_7
DO_0
~
DO_7
DO_0DO_0
~
DO_7
~
DO_7
ZT2052IOPQuickStart,v1.0,2013/06/07Page7
6. Appendix
LED Indicators
ZT2052IOP Status Remarks
SteadyLit ZigBeecommunicationisfunctioningcorrectly
FlashingOnce CommunicationtoZigBeeslave0x01hasbeenlost
FlashingTwice CommunicationtoZigBeeslave0x02hasbeenlost
…… ……
PWR
FlashingEightTimes CommunicationtoZigBeeslave0x08hasbeenlost
SteadyLit
AconnectiontotheZigBeenetworkhasbeensuccessfully
established
ZigBee
FlashingtoSteadyLit
The device is attempting to rejoin an existing ZigBee
network
DI ON/Off ThestatusoftheDIchannels
ZT2042 Status Remarks
SteadyLit Thepower ison
Blinking(200ms) TherewasaModuleInitializationfailure
Blinking(1s) TheHostWatchdogisenabled
PWR
SteadyUnlit Thepowerisoff
SteadyLit Thesignalstrengthishigh
Blinking(500ms)
A signal is available, but may become unstable if there is
someseriousinterference
Blinking(1s)
A signal is weak, and become unstable if there is any
interference
ZigBee
Blinking(2s) ThesignalispoorornoZigBeenetworkisavailable.
SteadyLit TheDOchannelisenabled
DO
SteadyUnlit TheDOchannelisdisabled
Technical Service
IfyouhaveanydifficultiesusingyourZT2000IOPseriesdevices,pleasesenda
descriptionoftheproblemtoservice@icpdas.com
Includethef
ollowingitemsinyouremail:
A description or diagram of the current DIP switch positions.
Take Photos or plan to show the real environment on-site between devices.
ZT2052IOPQuickStart,v1.0,2013/06/07Page8