• PACKAGE CONTENTS
Camera *1 Screwdriver *1
Self-tapping screws (4x31mm)*3 Guide Pattern Sticker *1
Self-tapping screws (4x45mm)*3 Plastic anchor *3
Network RJ45 Coupler * 1 BNC connector * 1
Printed Quick Start Guide *1 Document CD *1
•PARTS' LOCATIONS AND FUNCTIONS
1. Power In (Red+/Black-): power connector, DC12V/AC24V.
2. RJ-45 Ethernet Connector: network connection. Support PoE
(Power over Ethernet).
3. BNC: video output
4. Audio Out (Green): audio output
5. Audio In (Red): audio input
6. - Alarm Out (Orange): alarm signal output port.
- RS485+(Green): alarm signal output port.
- RS485- (Yellow): alarm signal output port.
7. - GND (Grey): ground
- Alarm In (Red): alarm signal input port.
- Alarm Reset (Brown): for resetting an external alarm device.
•Camera Installation
A. Mounting the camera- ceiling mount and wall mount
1.Mark hole positions: use the guide pattern sticker to mark hole positions
on the desired location. Drill 3 holes according the guide pattern and then
insert the plastic anchors into holes which you drill.
2.Install the camera: install the camera onto the ceiling/wall and fasten
securely using the screws provided.
use the screws
to fasten the camera
securely
1
2
3
4
5
6
7
Quick Start Guide
Please read this manual thoroughly before using, and keep it handy for future reference.
• SAFETY
1. This quick start guide is designed for users who have an adequate
knowledge of network cameras.
2. Do not touch the imaging surface of the sensor. Use a soft cloth moistened
with alcohol to clean the surface if it is touched accidentally.
3. Ensure the power supply voltage is correct for the particular variant of
camera before operation.
4. Do not attempt to service this camera yourself unless you are authorized
to do so. Opening the camera may expose you to electrocution or other
hazards. Refer all servicing to qualified personnel only.
5. For more detail on installation and operation, please refer to CD provided.
• Concept of Network Camera
i³ iP-Pro Server
Crossover direct connection
LAN
VIA a Gigabit Switch
i³ iP-Pro Server
Connection type: 1
Connection type: 2
3. Adjust the pan/tilt angle: rotate the main bracket adjust the pan
angle and rotate the pan adjustment to adjust the tilt angle. Then
adjust the camera zoom to a suitable position.
4.Adjust zoom/focus lever: loosen the zoom/focus lever
counterclockwise, and then rotate the zoom to adjust the image view or
adjust the focus for optimum picture sharpness. To
x the setting, please
tighten after adjustment.
6.Install the dome cover: place the dome cover to match the screw
positions and then tighten 3 screws to lock it securely using the
screwdriver provided.
• SPECIFICATION
Rotate the main
bracket
Adjust the
zoom lever
Adjust the
focus lever
1MP Network IR Dome CAMERA
QUICK START GUIDE
B. Assigning an IP address
1. The network camera is designed to be used on an Ethernet network. The
camera is set to use the default IP address of 192.0.0.16. If your
network supports DHCP, you will need to enable this feature from the
camera network settings.
2. To connect to the camera, the PC needs to be on the same IP address
range as the camera (ie. if the camera is 192.0.0.16 then the PC should
be 192.0.0.10), the last digits on the PC IP address needs to be different
from the last digits on the cameras IP address.
3. To make sure you can connect to the camera with your PC, ping the IP
address you set. Open command prompt and ping the IP address you
set. If the message of “Reply from…” appears, it means communication
is established.
4. Start a browser and enter the IP address: http://192.0.0.16, a pop-up
window will appear and will require you to login. Enter the default user
name: admin and password: 1234 to login.
5. Please install the ActiveX viewer that is required to view H.264,
MPEG4 or M-JPEG video.
6. Images of the camera can be viewed through your web browser IE V.6.0
& up. Before viewing, you have to follow the steps below.
i³ INTERNATIONAL INC.
1.866.840.0004
www.i3international.com
Canada 780 Birchmount Road,
Unit 16, Scarborough,
ON, M1K 5H4
U.S.A. 440 Lawrence Bell Drive,
Suite 16, Williamsville
NY, 14221
Security level settings
How to Change Security options in your browser
1. From the Tools menu, select Internet options.
2. Click on the Security tab.
3. If the camera is on the INTRAnet Click the Local intranet icon,
If the camera is on the INTERnet click the Internet icon.
4. Click on Custom level.
5. Check the following radio buttons in the display list:
Under ActiveX controls and plug-ins
* Enable "Download signed ActiveX controls"
* Enable "Run ActiveX control and plug-ins"
* Enable "Script ActiveX controls marked safe for scripting*"
6. Click OK.
Image System
Image sensor 1/3” 5MP CMOS image sensor optimized for low-light
performance
Effective pixels 2592 (H) X 1944 (V)
Image Compression Method Triple Streaming : H.264/ MPEG4 / M-JPEG
Resolution / Frame rate @30fps HD 720P (1280x720), VGA (640x480), (640x352),
(352x192)
Electric
Built-in lens f=2.7~9 mm, F1.2, Varifocal Megapixel lens
Shutter time AES 1/10000 to 1/3.75 sec
Audio Two-way Mono Audio
SD Slot Support micro SDHC card (up to 32GB)
Motion detection 4 x 3 MD window & 5 level sensitivity
Day & Night Mode Mechanical ICR Filter
Minimum illumination IR LED OFF: 0.3lux (F1.2, 50 IRE)
IR LED IR LED 24pcs(850nm)
IR distance 20 meters (60 ft.)
IR turn on status Under 10 lux by auto control
LED life More than 10,000 hours (50ºC)
Service Monitor output NTSC 1.0Vp-p, 75Ω
Feature
BLC ON/Off
White Balance 2500K~9600K
Power supply
Power requirement DC12V/ AC24V/ PoE(IEEE 802.3af)
when using the heater: DC24V / AC24V±10%
Power consumption < 8W (with heater use: < 18W)
Power connector Screw Terminal block
Environment
Operating temperature -40ºC ~ 50ºC (40ºF ~ 122 ºF) with heater
Operating humidity 0~ 80% RH
Storage temperature -20ºC ~ 60ºC (-4ºF ~ 140 ºF)
Network
Ethernet 1 x 10/100 base-T
Internet protocol TCP/IP, UDP, HTTP, SMTP, DNS, DHCP, NTP, FTP,
RTP,RTSP, ICMP, uPNP, DDNS
Connectors RJ-45 Ethernet 10Base-T/100Base-TX
Browser IE browser 6.0 or above
I/O connector
Network RJ45
Service Monitor BNC
Alarm Terminal block
Audio 3.5mm Phone Jack
Mechanism
Dimensions(LxWxH) ø158mmx144mm (ø6.22” x 5.67”)
Weight 1.28 kg (2.82 lb.)
Protection Class IP67
Warranty 1 year