5
Table of Contents – Volume 2
Chapter6 Image Management .................................................. 6-1
CINE / LOOP ................................................................................................................................. 6-3
Annotating Images ................................................................................................................... 6-6
Text .......................................................................................................................................................................................... 6-6
BodyMarker ......................................................................................................................................................................... 6-8
Indicator .............................................................................................................................................................................6-10
Saving and Transferring Images ...........................................................................................6-12
Saving Images ..................................................................................................................................................................6-12
Transferring Images .......................................................................................................................................................6-13
Printing and Recording Images ............................................................................................6-14
Printing Images .................................................................................................................................................................6-14
Recording Images ...........................................................................................................................................................6-14
SONOVIEW ................................................................................................................................ 6-15
Exam View ...........................................................................................................................................................................6-16
Exam Review ......................................................................................................................................................................6-22
Chapter7 Utilities ........................................................................ 7-1
Setting System ........................................................................................................................... 7-3
General ................................................................................................................................................................................... 7-3
Display ...................................................................................................................................................................................7-6
Misc.......................................................................................................................................................................................... 7-8
Setting Measurements ...........................................................................................................7-10
General .................................................................................................................................................................................7-10
Fetal Echo ...........................................................................................................................................................................7-19
Cardiac .................................................................................................................................................................................7-20
Urology Measurement Setup ......................................................................................................................................7-21
Vascular ...............................................................................................................................................................................7-23
Operation Manual
6
Setting DICOM (Optional) ......................................................................................................7-24
Setting DICOM Information .........................................................................................................................................7-25
Network Setup ..................................................................................................................................................................7-25
Adding or Changing the DICOM Server .................................................................................................................7-25
Editing the DICOM Server Information ...................................................................................................................7-31
Deleting DICOM Server ................................................................................................................................................. 7-31
Testing DICOM Server ...................................................................................................................................................7-31
DICOM Log ........................................................................................................................................................................7-31
Setting Option .......................................................................................................................... 7-33
Setting Peripheral Devices .....................................................................................................7-34
Information ............................................................................................................................... 7-36
Utility ......................................................................................................................................... 7-37
Biopsy ...................................................................................................................................................................................7-37
Monitor Calibration .........................................................................................................................................................7-40
Preset ....................................................................................................................................................................................7-41
Miscellaneous ....................................................................................................................................................................7-41
Chapter8 Maintenance............................................................... 8-1
Operating Environment ........................................................................................................... 8-3
System Maintenance ................................................................................................................. 8-4
Cleaning and disinfections ............................................................................................................................................ 8-4
Accuracy Check ................................................................................................................................................................... 8-5
Data Maintenance ..................................................................................................................... 8-6
User Setting Backup .......................................................................................................................................................... 8-6
Patient Data Backup .......................................................................................................................................................... 8-6
Software................................................................................................................................................................................. 8-6
Table of Contents
7
Chapter9 Probes ......................................................................... 9-1
Probes .......................................................................................................................................... 9-3
Ultrasound transmission Gel ......................................................................................................................................... 9-9
Sheaths................................................................................................................................................................................... 9-9
Probe Precautions ............................................................................................................................................................9-10
Cleaning and Disinfecting the Probe .......................................................................................................................9-12
Biopsy .........................................................................................................................................9-19
Biopsy KIT Components ................................................................................................................................................9-19
Using the Biopsy Kit ........................................................................................................................................................9-20
Cleaning and Disinfecting Biopsy Kit .......................................................................................................................9-22
Assembling the Biopsy Kit ............................................................................................................................................9-24
** Reference Manual
Samsung Medison is providing an additional SONOACE R3 Reference Manual. GA tables and references for
each application are included in the Reference Manual.
Chapter 6
Image Management
Chapter6 Image Management

î‚‹
CINE / LOOP ..................................................... 6-3

î‚‹
Annotating Images ....................................... 6-6
Text ................................................................................................6-6
BodyMarker ..............................................................................6-8
Indicator ...................................................................................6-10

î‚‹
Saving and Transferring Images ...............6-12
Saving Images ........................................................................6-12
Transferring Images .............................................................6-13

î‚‹
Printing and Recording Images ................6-14
Printing Images ......................................................................6-14
Recording Images ................................................................6-14

î‚‹
SONOVIEW.....................................................6-15
Exam View ................................................................................6-16
Exam Review ...........................................................................6-22
Chapter 6 Image Managemen
6-3
CINE / LOOP
Images are automatically saved in the memory during scanning. The saved images can be useful when a pa-
tient is diagnosed and reviewed.
The saved images can be in CINE or LOOP depending on the diagnosis mode.
â–¶
CINE: Images that are saved in all modes other than M Mode and Spectral Mode.
â–¶
LOOP: Images that are saved in M Mode and Spectral Mode.
[Figure 6.1 Reviewing Images]
Starting and Finishing Image Review
During scanning, press the Freeze button on the control panel. The scanning is stopped and the system
switches to the image review mode screen.
Press the Freeze button again to return to the scan mode.
Operation Manual
6-4
How to Review Images
Use the trackball on the control panel. You can search for saved images in chronological order by rotating
the Trackball to the left or right. The number of images saved so far and the number of the image cur-
rently under review are displayed in the user information area.
The Softmenu is changed when images are reviewed. Select the item and adjust the value with the
Softmenu button [1] – [5] on the control panel.

â– 
Auto Run
Use the Softmenu button [1]. CINE Mode or LOOP Mode is automatically played and repeated. To stop
Auto Run, press this button again.

â– 
CINE / LOOP
Use the Softmenu button [2]. This option appears only when both CINE and LOOP are available, as in M
Mode or Spectral Doppler Mode. You can select an image to play in CINE and LOOP by pressing the but-
ton. The selection is displayed in the left side of the user information area.

â– 
Cine Edit
Use the Softmenu button [3]. Set the range of the Cine mode. When you press this button, the Cine Edit
Bar will be displayed and the Softmenu will be changed;
â–¶
Set Cine start point: press the Softmenu button [3] Frame Start and set the start point using the
Set button.
â–¶
Set Cine end point: press the Softmenu button [4] Frame End and set the start point using the Set
button.
â–¶
Finish setting: press the Softmenu button [5] Cine Save to save the start and the end point.
Tips!
Set using the Cine Edit Bar
Set the start point using trackball and the Set button and press the Change button to set the end
point
Chapter 6 Image Managemen
6-5

â– 
Cine Save
Use the Softmenu button [4]. Save the Cine whole Cine images.
NOTE:
X
When saving a Cine image, the current time at the top right of the screen stops displaying.
When the image is saved, the current time displays again. The saved Cine image contains the
time at which saving started.
X
This system is optimized at a maximum of 60 Hz when playing Cine. Up to 60 Hz can be set
during Auto Run, but if it is set higher than 60 Hz, the speed of the image may slow down.
In Cine Save, images are saved at the actual frame rate.

â– 
Speed (%)
Use the Softmenu button [5]. Change the speed of Auto Run. When you press this button repeatedly, it
changes as 10%, 40%, 70% and 100%.
Reviewing Images in Multi-Image Mode
Only images in an active area can be reviewed in multi-image mode. To review images in another area,
change the active area by using the Set or the Dual button on the control panel.
Operation Manual
6-6
Annotating Images
Text
You can enter comments or text over an image. This function can be useful when the diagnosis area is dier-
entiated or displayed.
Starting Text Mode
Press the Text key in the Keyboards. The system will switch to text mode.
Typing Text
Use keyboards. You can move the cursor by using the trackball or the arrow keys on the keyboard.
[Figure 6.2 Text Mode]
Chapter 6 Image Managemen
6-7
Autotext
This function allows you to enter text automatically by using an abbreviation. In this way, you can enter
text easily and quickly. When Autotext is enabled, the autotext list appears on the screen.
[Figure 6.3 The Autotext List]
NOTE: Select Setup > System > General > Autotext Set.
Deleting Text
Press the Clear button on the control panel. All the text entered on the screen will be deleted.
Exiting Text Mode
Press the Exit button on the control panel.
Operation Manual
6-8
BodyMarker
You can place a BodyMarker over an image. This function can be useful when the diagnosis area is dierenti-
ated or displayed.
[Figure 6.4 BodyMarker Mode]
Starting BodyMarker Mode
Press the BodyMarker key on the keyboards. The system will switch to BodyMarker input mode and Body-
Markers will appear in the user information area.
NOTE: If Setup > System > Display > BodyMarker After Freeze is set to ‘On’ and the Freeze
button is clicked, the mode immediately switches to BodyMarker mode.
Chapter 6 Image Managemen
6-9
Entering BodyMarker
1. Press the BodyMarker key on the keyboards, BodyMarkers will appear on the user information area.
â–¶
The types of BodyMarker shown in the Softmenu vary with the diagnosis mode.
â–¶
A maximum of 5 BodyMarkers are displayed on the screen at any one time. When there are more
BodyMarkers than this, press the BodyMarker key or the Space bar repeatedly to move to other pag-
es.
2. Press the Softmenu button for the BodyMarker that you want. The BodyMarker will appear in the image.
â–¶
Position the probe cursor on the BodyMarker using the trackball.
â–¶
Use the Angle dial-button on the control panel to adjust the angle of the probe cursor.
3. Press the Set button to nish.
Changing BodyMarker Position
1. Press the Change button on the control panel.
2. Move the BodyMarker to a desired position by using the Trackball.
3. Press the Change button on the control panel again to conrm the new position.
Deleting BodyMarker
Press the Clear button on the control panel.
Exiting BodyMarker Mode
Press the Exit button on the control panel.
Operation Manual
6-10
Indicator
You can place an Indicator over an image. This function can be useful when the diagnosis area is dierenti-
ated or displayed. You can place one or more Indicators on specic positions.
[Figure 6.5 Indicator Mode]
Starting Indicator Mode
Press the Indicator button on the control panel. The system will switch to the Indicator mode.
Entering Indicator
1. Press the Indicator button on the control panel and an Indicator will appear on the screen.
2. Move the Indicator to a desired position by using the trackball.
3. Adjust the Indicator direction by using the Angle dial on the control panel.
4. Press the Set button to nish. Press the Exit button to cancel.
Chapter 6 Image Managemen
6-11
Deleting Indicator
Press the Clear button on the control panel and all Indicators displayed on the screen will be deleted.
Exiting Indicator Mode
Press the Exit button on the control panel.
Operation Manual
6-12
Saving and Transferring Images
Saving Images
NOTE: You must enter the patient ID because all images are saved according to patient ID. Failure
to enter a patient ID may result in a loss of and/or critical error(s) in previously saved images.
Press the Save button on the control panel. The saved images can be edited and managed with SONOVIEW.
Tips!
Thumbnail
If Setup > System > Misc. > Thumbnail is set to ‘On’, the saved images are displayed in thumbnail
area.
Saving an Image with Text
NOTE: It’s convenient to save an image with description for later search.
For more information about entering text, refer to ‘Annotating Images’ in this chapter.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128

Samsung SONOACE R3 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI