Vent-a-Hood NPH18236SS Installation guide

Type
Installation guide

This manual is also suitable for

FOR UNDER CABINET VENT-A-HOODS
INSTALLATION INSTRUCTIONS
Read and Save These Instructions
- Step 1.  Cut out cabinet. 
A. Model B100  Use template provided.
-
Step 2.  Install canopy in position under cabinet. 
B. Model B200  Mark cabinet per sketch.
*Make sure cutout is large enough for motor cooling vents.
(Motors are cooled from above).
A. Attach securely to bottom of cabinet with screws provided.
-
Step 3.  Connect ducting. 
A. Model B100: 6 duct or the
equivalent must be installed
throughout.
B. Model B200: Transition to 8
round is provided. 8 duct or the
equivalent must be installed
throughout.
Turn Page For More Instructions
Do not restrict ducting anywhere including roof jacks or wall louvers. Dont
make sharp turns with ducting. Make gradual turns or 45° angles.
of Hood
C
L
of Hood
C
L
8
6
9
of Hood
C
L
of Hood
C
L
2 
3
8
/
B200 Dual
Blower
Blower
Minimum Round
Duct Size
Square
Inches
B100 Single 300 CFM
6 (or equivalent)
28
B200 Dual 600 CFM 8 (or equivalent)
50
B100 Single
Blower
6
of Collar
C
L
12
2 
3
1
6
/
9
Length
2
1
of Hood
C
L
3 
3
8
/
5 
1
8
/
A. Installation Work and Electrical Wiring Must Be Done By
Qualified Person(s) In Accordance With All Applicable
Codes And Standards, Including Fire-Rated Construction.
B. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
C. Ducted fans must always be vented to the out-
doors.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
D. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the
heating equipment manufacturers guideline and safety
standards such as those published by the NationaI Fire
Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and local code authorities.
All Hoods Should Be Installed By A Qualified Installer
1 from back
edge of hood
6
 hole for
electric
7
8
/
of Hood
L
C
1
4
/
9 
3
8
/
5 
1
2
/
8
1
4
/
7
11
16
/
1  from back
edge of hood
Motor Cooling
Vents
Cutout
6exhaust collar is 3  left of
center. Offset Kit VP529 or VP550
are available to bring duct back to
centerline.
3
8
/
of exhaust collar
C
L
of mounting plate
C
L
Front
Motor Cooling
Vents
Wiring
3 
3
8
/
1
8
/
5 
6 dia.
To Wall Transition
#100 MODELS 3 x 10
1
4
/
#200 MODELS 3 x 12*
1
4
/
In Wall Transition
12
12
- Step 4.  Connect electrical. 
Observe All Governing Codes and Ordinances
1000 N. Greenville Ave.
=
P.O. Box 830426
=
Richardson, TX 75083
=
(972) 235-5201
Methods of Ducting Your Vent-A-Hood
Venting Configurations
Venting Materials Available from Vent-A-Hood
Other Transitions by Special Order
Follow label instructions and remove motor plate. Unplug motor and remove, being careful to not damage blower wheel. Connect electrical, black to
black, white to white and ground to lug provided. Hoods with multiple blower units require separate electrical connections. Replace motor(s) and dont
forget to plug them back in. Replace blower front and be sure it is secured properly and blower wheel(s) turn freely. Model B100,1.7 Amps. Model
B200, 3.4 Amps. Hoods with heat lamps and/or halogen lamps, 8.0 Amps.
Duct
Hood
Open area --
no screen
Outside
Wall
Straight Back
Roof Jack
tape
6 Round Duct
#100 MODELS
6 Adj. Ell
3
#200 MODELS
Angle Turn
8 Round
Transition Supplied
6
1
4
/
3 
6 x 8 
Back Vent Ell
1
2
/
Duct
Round Vent Duct
30
6,7,8,9
Rect. Vent Duct
30
10
8
16
1
2
/
6, 3
1
4
/
Round Collar
6,7,8,9
Rect. Collar
6
8
1
2
/
Reducer
6
7
8
Transition, 3 X10 to 6/7
1
4
/
6,7
12
10
3
1
4
/
Wall Mount Transition
8
6
6
8
1
2
/
Back Vent Ell
6
6
16
8
1
2
/
9
1
4
/
Offset Kit
6
7
11
16
Adjustable Elbow
6,7,8,9
Wall Louver Venting
in 2-Story Dwelling
Hood
Floorline
(2nd floor)
Ceiling Line
(1st floor)
tape
Duct
Outside
Wall
Open
area --
no
screen
Roof Jack - 6,7,8 (10 & 12 available)
18
18
16
specify
roof pitch
1
/
2
6,7,8
5
8
/
8
Wall Louver (10
& 12 available)
LP Roof Jack 6,7,8 (10 & 12 available)
17
17
1
2
/
6
2/25/99
II-UC
Caution: to reduce the risk of fire or electrical shock, do not use this fan with any solid state speed control device.
  • Page 1 1
  • Page 2 2

Vent-a-Hood NPH18236SS Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI