  • Hello! I am an AI chatbot trained to assist you with the Altronix ALTV248ULHI Installation Manuals. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Rev. 113004
More than just power.
TM
Isolated Series
CCTV Power Supplies
Installation Guide
Models Include:
ALTV248ULHi
- 24VAC @ 12.5A total output.
- Eight (8) 1.56A Fuse Protected
Isolated Outputs.
ALTV248ULMi
- 24VAC @ 12.5A total output.
- Eight (8) 1.56A Fuse Protected
Isolated Outputs.
ALTV2416ULi
- 24VAC @ 25A total output.
- Sixteen (16) 1.56A Fuse Protected
Isolated Outputs.
ALTV248ULCBHi
- 24VAC @ 12.5A total output.
- Eight (8) 1.56A PTC Protected
Isolated Outputs.
ALTV248ULCBMi
- 24VAC @ 12.5A total output.
- Eight (8) 1.56A PTC Protected
Isolated Outputs.
ALTV2416ULCBi
- 24VAC @ 25A total output.
- Sixteen (16) 1.56A PTC Protected
Isolated Outputs.
- 2 - UL Listed Isolated Series
Overview:
Altronix Isolated CCTV Power Supplies provide 24VAC distributed via eight (8) or sixteen (16) fuse or PTC
protected isolated outputs for powering CCTV cameras, heaters, and other video accessories.
Isolated Power Supply Reference Chart:
Altronix
Model Number
Output
Voltage
Total
Output
Current
Number
of
Outputs
PTC Protected
auto-resettable
Outputs
(Class 2
Power-Limited
for dry
locations)
Fuse
Protected
Outputs
Output
Current
(max per
output)
115VAC
50/60Hz
Input
Current Agency Listing
ALTV248ULHi
24VAC 12.5A 8
P
1.56A 3A
ALTV248ULCBHi
24VAC 12.5A 8
P
1.56A 3A
ALTV248ULMi
24VAC 12.5A 8
P
1.56A 3A
ALTV248ULCBMi
24VAC 12.5A 8
P
1.56A 3A
ALTV2416ULi
24VAC 25A 16
P
1.56A 6A
ALTV2416ULCBi
24VAC 25A 16
P
- 1.56A 6A
Add suffix “3” for 3-wire line cord (e.g. ALTV248ULHi3).
Specifications:
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with
all local codes and authorities having jurisdiction. Product is intended for indoor use only.
1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes
in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place
the enclosure’s upper keyholes over the two upper screws, level and secure. Mark the position of the lower
two holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s
upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws
(Enclosure Dimensions, pgs. 7, 8). Secure enclosure to earth ground.
2. Set power switch to OFF position on all models (Figs. 1 - 3, pgs. 4 - 6).
3. All units are factory set for 24VAC operation.
4. Secure green lead to earth ground. Connect AC power to the black and white flying leads of the
transformer(s) (Figs. 1 - 3, pgs. 4 - 6). Use 18 AWG or larger for all power connections.
Keep power-limited wiring (PTC protected outputs only) separate from non power-limited wiring.
Minimum 0.25” spacing must be provided. Use separate knockouts
5. Measure output voltage before connecting devices. This helps avoiding potential damage.
Terminals marked [1A - 8A] and [1B - 8B] are of the same polarity (phase).
6. Connect CCTV cameras to output terminals using the following procedure:
Camera 1 to output 1A & 1B. Camera 5 to output 5A & 5B.
Camera 2 to output 2A & 2B. Camera 6 to output 6A & 6B.
Camera 3 to output 3A & 3B. Camera 7 to output 7A & 7B.
Camera 4 to output 4A & 4B. Camera 8 to output 8A & 8B.
7. Set power switch on all models to the “RESET” (ON) position (Figs. 1 - 3, pgs. 4 - 6).
8. Upon completion of the wiring, secure enclosure door with screws (supplied).
Agency Listings:
UL Listed for Commercial CCTV Equipment
(UL2044).
CUL Listed - CSA Standard C22.2 No.1-98,
Audio, Video and Similar Equipment.
Input:
115VAC, 50/60Hz.
Output:
Eight (8) or sixteen (16) fuse or PTC
protected outputs.
24VAC outputs.
Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
Surge suppression.
Features:
Individual electronically isolated outputs.
Illuminated master Power ON/OFF switch
with built-in circuit breaker.
Unit maintains camera synchronization.
Ease of installation saves time & eliminates
costly labor.
Spare fuses included (on fuse protected models).
Enclosure Dimensions (H x W x D approx.):
ALTV248ULMi, ALTV248ULCBMi:
8.5” x 7.5” x 3.875” (215.9mm x 191mm x 98.4mm).
ALTV248ULHi, ALTV248ULCBHi,
ALTV2416ULi, and ALTV2416ULCBi:
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.6mm).
UL Listed Isolated Series - 3 -
Caution: Equipment to be installed/serviced by authorized/trained personnel only.
Shut branch circuit power before installing/servicing equipment.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This
installation should be made by qualified service personnel and should conform to the National Electrical
Code and all local codes. Use 75˚C or higher rated UL insulated wiring for connecting the unit to the
mains. Replace fuses with the same type and rating (3.5A/250V).
Terminal Identification:
PD8i - Distribution Module
1A - 8A Phase 1
1B - 8B Phase 2
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user
to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may
be of sufficient magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of
important operating and maintenance (servicing) instructions in the literature accompanying the
appliance.
CAUTION: To reduce the risk of electric shock do not open
enclosure. There are no user serviceable parts inside. Refer servicing
to qualified service personnel.
- 4 - UL Listed Isolated Series
Illuminated Power Disconnect
Circuit Breaker with manual reset
PD8I
ISOLATED POWER
DISTRIBUTING BOARD
F1 F2 F3 F4 F5 F6 F7 F8
PD8I
ISOLATED POWER
DISTRIBUTING BOARD
F1 F2 F3 F4 F5 F6 F7 F8
non power-limited
Used on ALTV248ULCBHi
Class 2 power-limited
1A 2A 3A 4A 5A 6A 7A 8A
1B 2B 3B 4B 5B 6B 7B 8B
1A 2A 3A 4A 5A 6A 7A 8A
1B 2B 3B 4B 5B 6B 7B 8B
Black Lead
White Lead
Green Lead
(ground)
Input
115VAC, 50/60Hz
Fig. 1 - ALTV248ULHi and ALTV248ULCBHi
UL Listed Isolated Series - 5 -
Fig. 2 - ALTV248ULMi and ALTV248ULCBMi
Illuminated Power Disconnect
Circuit Breaker with manual reset
Transformer
underneath
power distribution
board
PD8I
ISOLATED POWER
DISTRIBUTING BOARD
F1 F2 F3 F4 F5 F6 F7 F8
non power-limited
PD8I
ISOLATED POWER
DISTRIBUTING BOARD
F1 F2 F3 F4 F5 F6 F7 F8
Used on ALTV248ULCBMi
Class 2 power-limited
1A 2A 3A 4A 5A 6A 7A 8A
1B 2B 3B 4B 5B 6B 7B 8B
Input
115VAC,
50/60Hz
Green Lead
(ground)
- 6 - UL Listed Isolated Series
Fig. 3 - ALTV2416ULi and ALTV2416ULCBi
PD8I
ISOLATED POWER
DISTRIBUTING BOARD
F1 F2 F3 F4 F5 F6 F7 F8
non power-limited
PD8I
ISOLATED POWER
DISTRIBUTING BOARD
F1 F2 F3 F4 F5 F6 F7 F8
non power-limited
PD8I
ISOLATED POWER
DISTRIBUTING BOARD
F1 F2 F3 F4 F5 F6 F7 F8
Used on ALTV2416ULCBi
Class 2 power-limited
1A 2A 3A 4A 5A 6A 7A 8A
1B 2B 3B 4B 5B 6B 7B 8B
Illuminated Power Disconnect
Circuit Breaker with manual reset
Green Lead
(ground)
Input
115VAC, 50/60Hz
UL Listed Isolated Series - 7 -
Enclosure Dimensions (H x W x D) for:
• ALTV248ULMi • ALTV248ULCBMi
8.5” x 7.5” x 3.875” (215.9mm x 191mm x 98.4mm)
3.63”
(92.2mm)
7.25”
(184.15mm)
7.25”
(
184.15mm
)
1”
(25.4mm)
1”
(25.4mm)
1”
(25.4mm)
1.75”
(44.45mm)
8.13”
(206.5mm)
8.13”
(206.5mm)
3.85”
(97.79mm)
1”
(25.4mm)
1”
(25.4mm)
1”
(25.4mm)
3.85”
(97.79mm)
1”
(25.4mm)
1.25”
(31.75mm)
1.25”
(31.75mm)
1.25”
(31.75mm)
1.25”
(31.75mm)
3.85”
(97.79mm)
0.6”
(15.24mm)
0.6”
(15.24mm)
0.6”
(15.24mm)
0.6”
(15.24mm)
0.9”
(22.86mm)
0.9”
(22.86mm)
- 8 - UL Listed Isolated Series
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
website: www.altronix.com | e-mail: [email protected] | Lifetime Warranty | Made in U.S.A.
IIULisolatedSeries D06R
MEMBER
1.40
(36mm)
1.40”
(36mm)
4.85
(123mm)
4.85
(123mm)
1.40
(36mm)
1.40”
(36mm)
5.10”
(130mm)
5.10
(130mm)
13.0
(330mm)
5.10
(130mm)
6.5625
(167mm)
1.20
(31mm)
1.20”
(31mm)
1.20”
(31mm)
3.25
(83mm)
3.25”
(83mm)
3.25”
(83mm)
3.25
(83mm)
1.0”
(25mm)
1.0”
(
25mm
)
10.5”
(
267mm
)
1.0”
(
25mm
)
1.0”
(25mm)
0.75”
(19mm)
0.75”
(19mm)
0.9375”
(24mm)
0.9375”
(24mm)
11.0”
(279mm)
12.5”
(318mm)
Enclosure Dimensions (H x W x D) for:
• ALTV248ULHi • ALTV248ULCBHi
• ALTV2416ULi • ALTV2416ULCBi
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.6mm)
/