Architectural Spot & Flood Light
INSTALLATION GUIDE
GVA Lighting, Inc. 3400 Ridgeway Drive, #14 Missisauga, Ontario L5L 0A2
IG-LIRA, 2018-08-28 | Page 6 / 9
Specifications are subject to change without notice. Every effort has been made to ensure that the information provided in this manual is accurate.
GVA Lighting Inc. is not responsible for printing or clerical errors. Refer to www.gvalighting.com for additional information.
LIRA
™
2.3
JUNCTION BOX DIAGRAM: DMX
WARNING
Ensure power supply is turned OFF before making any connections. Connecting the luminaire while the power is turned
ON may result in equipment damage.
Connect Class 2, 24VDC output to power conductors of ELV LIRA luminaire : red(+), black(-). Connect DMX I/O to DMX conductors of luminaire.
NOTE: LIRA luminaires require 24VDC Class 2 power supply. Total load shall
not exceed power rating of PDB-ELV/PS-ELV and should be under 100W
to remain Class 2. If PSU is other than Class 2, provisions must be made to
create Class 2 outputs.
NOTE: Diagram shows 2C power cable and 5C data cable option. GVA 7C
power and data cable available (supplied separately). See specification sheet
for ordering information.
2.3.A Junction Box Wiring Diagram: DMX Bus
(supplied by others)
(supplied by others)
24VDC INPUT CABLE
(from PDB, supplied by others)
24VDC OUTPUT CABLE
(supplied by others)
DMX OUTPUT CABLE
(supplied by others)
DMX OUTPUT CABLE
(from PDB, supplied by others)
24VDC & DMX OUTPUT
24VDC & DMX OUTPUT
2.3.B Junction Box Wiring Diagram: DMX Radial/ Star
24VDC INPUT CABLE
(from PDB, supplied by others)
DMX OUTPUT CABLE
(supplied by others)
24VDC & DMX OUTPUT
24VDC & DMX OUTPUT
(to DMX luminaire)
24VDC & DMX OUTPUT
(to DMX luminaire)
(to DMX luminaire)
2.3.C Luminaire Connections: DMX
INPUT/OUTPUT
RED = +24VDC
BLACK = -24VDC
ORANGE = DMX (-) INPUT
ORANGE/WHITE = DMX (+) INPUT
BLUE = DMX (-) OUTPUT
BLUE/WHITE = DMX (+) OUTPUT
BROWN/WHITE = DMX COMMON