Gigabyte GS-R1270-RH Owner's manual

Type
Owner's manual

Gigabyte GS-R1270-RH is a 1U Rack Mount Server with various advanced features:

  • Supports dual Intel Xeon LGA771 processors, providing high computing power and efficiency.
  • Equipped with a serverboard that offers flexible expansion options, allowing for customization and scalability.
  • Supports up to 32GB of DDR2 ECC Registered memory, ensuring reliable data handling and fast performance.
  • Features hot-swappable hard disk drive bays for easy maintenance and data protection.
  • Includes a rich set of I/O ports, including USB, serial, and Ethernet, for seamless connectivity.
  • The system is designed with a sturdy chassis, ensuring durability and protection in a rack-mounted environment.

Gigabyte GS-R1270-RH is a 1U Rack Mount Server with various advanced features:

  • Supports dual Intel Xeon LGA771 processors, providing high computing power and efficiency.
  • Equipped with a serverboard that offers flexible expansion options, allowing for customization and scalability.
  • Supports up to 32GB of DDR2 ECC Registered memory, ensuring reliable data handling and fast performance.
  • Features hot-swappable hard disk drive bays for easy maintenance and data protection.
  • Includes a rich set of I/O ports, including USB, serial, and Ethernet, for seamless connectivity.
  • The system is designed with a sturdy chassis, ensuring durability and protection in a rack-mounted environment.
System Installation Guide
GS-R1270-RH
1U Rack Mount Server
Dual Intel® Xeon LGA771 Processor Serverboard
Rev. 1.0
2
Table of Content
Table of Contents
Safety, Care and Regulatory Information................................................4
Introduction..............................................................................................8
Contents Packages ................................................................................8
Chapter 1 Features Summary.................................................................9
Chapter 2 System Hardware Installation ............................................... 11
Step 2-1: Chassis Removal and Installation .................................................................11
Step 2-2: CPU Installation............................................................................................... 12
Step 2-3: Heat Sink Installation....................................................................................... 13
Step 2-4: Memory Installation ........................................................................................ 14
Step 2-5: PCI Expansion Card Installation.................................................................... 15
Step 2-6: Hard Disk Drive Installation ............................................................................ 16
Step 2-7: FAN Duct Removal and Installation.............................................................. 17
Chapter 3 Appearance of GS-R1270-RH .............................................18
3-1: Front View of GS-R1270-RH.................................................................................. 18
3-2: Rear View of GS-R1270-RH .................................................................................. 19
3-3: Switch and LED Indicators Introduction ................................................................. 20
3-4: LAN LED Description............................................................................................... 21
3-5: Connector Icon Description..................................................................................... 22
Chapter 4 Motherboard Jumper Setting ...............................................23
4-1: GA-7VCSV1-RH Motherboard Jumper Setting ..................................................... 23
Chapter 5 BIOS Setup ..........................................................................25
Main...........................................................................................................27
Advanced Processor Options ........................................................................................ 29
Advanced ...................................................................................................31
Memory Configuration..................................................................................................... 32
PCI Configuration............................................................................................................. 34
I/O Device Configuration................................................................................................. 35
Advanced Chipset Control ............................................................................................. 38
Hardware Monitor ............................................................................................................ 40
3
GS-R1270-RH Rack Mount Server
Security ......................................................................................................43
Server.........................................................................................................45
System Management...................................................................................................... 46
Console Redirection........................................................................................................ 47
Boot............................................................................................................49
Exit .............................................................................................................50
4
Safety Information
Safety, Care and Regulatory Information
/Important safety information
Read and follow all instructions marked on the product and in the documentation before you operate
your system. Retain all safety and operating instructions for future use.
* The product should be operated only from the type of power source indicated on the rating label.
* If your computer has a voltage selector switch, make sure that the switch is in the proper position for
your area. The voltage selector switch is set at the factory to the correct voltage.
* The plug-socket combination must be accessible at all times because it serves as the main disconnect-
ing device.
* All product shipped with a three-wire electrical grounding-type plug only fits into a grounding-type power
outlet. This is a safety feature. The equipment grounding should be in accordance with local and national
electrical codes. The equipment operates safely when it is used in accordance with its marked electrical
ratings and product usage instructions
* Do not use this product near water or a heat source.
* Set up the product on a stable work surface or so as to ensure stability of the system.
* Openings in the case are provided for ventilation. Do not block or cover these openings. Make sure you
provide adequate space around the system for ventilation when you set up your work area. Never insert
objects of any kind into the ventilation openings.
* To avoid electrical shock, always unplug all power cables and modem cables from the wall outlets
before removing covers.
* Allow the product to cool before removing covers or touching internal components.
/Precaution for Product with Laser Devices
Observe the following precautions for laser devices:
* Do not open the CD-ROM drive, make adjustments, or perform procedures on a laser device other than
those specified in the product's documentation.
* Only authorized service technicians should repair laser devices.
/Precaution for Product with Modems, Telecommunications, ot Local Area
Network Options
Observe the following guidelines when working with options:
* Do not connect or use a modem or telephone during a lightning storm. There may be a risk of electrical
shock from lightning.
5
GS-R1270-RH Rack Mount Server
* To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord.
* Do not plug a modem or telephone cable into the network interface controller (NIC) receptacle.
* Disconnect the modem cable before opening a product enclosure, touching or installing internal
components, or touching an uninsulated modem cable or jack.
* Do not use a telephone line to report a gas leak while you are in the vicinity of the leak.
/Federal Communications Commission (FCC) Statement
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission
limits. Neither the provider nor the manufacturer are responsible for any radio or television interference
caused by using other than recommended cables and connectors or by unauthorized changes or
modifications to this equipment. Unauthorized changes or modifications could void the user's authority to
operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation.
/FCC part 68 (applicable to products fitted with USA modems)
The modem complies with Part 68 of the FCC Rules. On this equipment is a label that contains, among
other information, the FCC registration number and Ringer Equivalence Number (REN) for this equipment.
You must, upon request, provide this information to your telephone company.
If your telephone equipment causes harm to the telephone network, the Telephone Company may
discontinue your service temporarily. If possible, they will notify in advance. But, if advance notice is not
practical, you will be notified as soon as possible. You will be informed of your right to file a complaint with
the FCC.
6
Safety Information
Your telephone company may make changes in its facilities, equipment, operations, or procedures that
could affect proper operation of your equipment. If they do, you will be notified in advance to give you an
opportunity to maintain uninterrupted telephone service.
The FCC prohibits this equipment to be connected to party lines or coin-telephone service.
The FCC also requires the transmitter of a FAX transmission be properly identified (per FCC Rules Part
68, Sec. 68.381 (c) (3)).
/ for Canadian users only /
/Canadian Department of Communications Compliance Statement
This digital apparatus does not exceed the Class B limits for radio noise emissions from digital
apparatus as set out in the radio interference regulations of Industry Canada.
Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites applicables aux
appareils numeriques de Classe B prescrites dans le reglement sur le brouillage radioelectrique edicte par
Industrie Canada.
/DOC notice (for products fitted with an Industry Canada-compliant modem)
The Canadian Department of Communications label identifies certified equipment. This certification
means that the equipment meets certain telecommunications network protective, operational and safety
requirements. The Department does not guarantee the equipment will operate to the user satisfaction.
Before installing this equipment, users ensure that it is permissible to be connected to the facilities of the
local Telecommunications Company. The equipment must also be installed using an acceptable method
of connection. The customer should be aware that compliance with the above conditions might not prevent
degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated
by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions,
may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility,
telephone lines and internal metallic water pipe system, if resent are connected together. This precaution
may be particularly important in rural areas.
Caution: Users should not attempt to make such connections themselves, but should contact the
appropriate electric inspection authority, or electrician, as appropriate.
7
Safety Information
NOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the total
load to be connected to a telephone loop which is used by the device, to prevent overloading. The
termination on a loop may consist of any combination of devices subject only to the requirement that the
sum of the Load Numbers of all the devices does not exceed 100.
/ for European users only /
CAUTION
Danger of explosion if battery is incorrectly
replaced.
Replace only with the same or equivalent
type recommended by the manufacturer.
Dispose of used batteries according to the
manufacturer’s instructions.
8
GS-R1270-RH Rack Mount Server
;Chassis ;GA-7VCSV1-RH Motherboard (Installed)
;Power Supply (Installed) ;FAN Duct x 1
;CPU Heat Sink x 2 ;Slim type DVD-Combo (Installed)
;Cables (RJ45) ;Case Handle Kit x 2
;GS-R1270-RH Quick Refernece Guide
;Driver CD for motherboard driver & utility
Introduction
Welcome to Gigabyte GS-R1270-RH Rack mount Server System Installation Guide. The guide
provides instructions for configuration hardware for the GS-R1270-RH your system.
This installation guide will assist you in installing all the essential components for the sever system.
For your protection, please read and undertand all of the safety and operating instructions regarding your
Gigabyte Server and retain for future reference. The procedures in this guidebook assume that your are
a system or network administrator experienced in installing similar hardware.
Contents Packages
When opening the package, please ensure the system components are not damaged during the shipping.
Using the following checklist to verify the contents. If any component is missing or damaged in the
system, please contact your vendor immediately.
* The items listed above are for reference only, and are subject to change without notice.
9
GS-R1270-RH Rack Mount Server
Motherboard yGA-7VSCV1-RH
Processor Supported ySupports Dual Intel® XeonTM processors
yXeonTM Dual/Quad Core in LGA 771 socket
ySupports 667/1066/1333MHz FSB
(Dempsey/Woodcrest/Clovertown/Harpertown/Wolf-dale )
yL2 cache on-die per processor from 4M
Chipset yIntel® 5000V Chipset
yIntel® 6321ESB
System Memory:
Memory Capacity y4 x 240-pin Fully Buffered DIMM sockets 16GB
Memory Type yDual Channel ECC Registered 533/667 memory
DIMM Size ySupport 256MB, 512MB, 1GB, 2GB, and 4GB memory
Error Correction: ySingle-bit Errors Correction, Multiple Bit Errors Detection
Expansion Slot y1 Riser card supports 1 full-height PCI-X 133MHz and 1 PCI-E x
8 slots (at x4 bandwidth)
y1 SO-DIMM add-on card
SATA RAID controller yIntel® 6321ESB built in SATA RAID 0,1,5 (Windows Only)
ySupports LSI Software SW RAID 0/1/5 (Windows only)
Cooling Fans: y5 X Easy-Swap Fans
Integrated LANs:
Controller yIntel® 82563EB controller supports dual GbE LAN ports
Integrated Graphics:
Controller yXGI Volari Z9s
Graphics Memory y256MB DDR2
Mass Storage System y3 x Hot-Swap SATA HDDs
y1 x Slim typeDVD Combo
Super I/O
Controller yITE IT8718F Super I/O
Built-in I/O y2 x Serial port (COM)
y4 x USB 2.0 port connectors (2 at front panel)
y1 x VGA connector
y2 x RJ45 LAN ports
Chapter 1 Features Summary
10
Feature Summary
yP/S 2 Keyboard and Mouse Connectors
Hardware Monitor yWinbond 83793G controller
yEnhanced features with CPU VCOREA, VCOREAB, VCC3 (3.3V),
VCC5V, VBAT; CPU and Motherboard Temperature
ySystem Voltage Detect
yCPU/System Fan Revolution Detect
System BIOS:
BIOS Type yPhoenix BIOS on 8Mb flash ROM
Server Management Functions: (Optional device)
BMC Chip yH8S/2168V
Failure Detection yIPMI 1.0 specification of Server management
Event Logging y128 KB Nonvolatile Memory to Log System Failure Events
Remote Management yFollow the IPMI 1.0 Specification Server management
Environment
Ambient Temperature yOperating Temperature: 5oC to 60oC
yNon-operating Temperature: 0oC to 50oC
Relative Humidity y10-80% operating Humidity at 30o C
System Dimention: y427.5mm x 567.5mm x 43.5 mm
Electrical Power Supply ySingle Power Supply 550W
11
GS-R1270-RH Rack Mount Server
Please observe the safety information in chapter “Important Safety Information”
Do not expose the server to extreme environmental conditions. Protect it from dust,
humidity, and heat.
Step 2-1: Chassis Removal and Installation
Step 1 Push down the indentation located at two sides of the chassis.
Step 2 Slide toward the top chassis cover.
Step 3 Lift up to remove the top chassis cover.
Step 4 Reverse Step 1, ,2, 3 to replace the chassis cover
Chapter 2 System Hardware Installation
1
32
1
12
Hardware Installation Process
Step 2-2: CPU Installation
Please make sure the CPU type and speed that are supported by the motherboard.
Step 1 Raise the metal locking lever on the socket. Insert the CPU with the correct orientation.
Step 2 The CPU only fits in one orientation.
Step 3 Push the metal lever back into locked position.
1
2
3
13
GS-R1270-RH Rack Mount Server
Step 2-3: Heat Sink Installation
Step 1 Place the Heat Sink on the CPU. Before putting the heat sink on the CPU, please well
remember to apply the thermal conductivity compound on the CPU.
Step 2 Seat the heat sink in the retention modules with the four screws. Installation completed.
1
2
2
22
14
Hardware Installation Process
Step 2-4: Memory Installation
Step 1. Insert the DIMM memory module vertically into the DIMM slot, and push it down.
Step 2. Close the plastic clip at both edges of the DIMM slots to lock the DIMM module.
NOTE! DIMM must be populated in order starting from DIMM8 socket. For dual-channel
operation, DIMMs must be installed in matched pairs.
Step 3. Reverse the installation steps when you wish to remove the DIMM module.
1
2
2
15
GS-R1270-RH Rack Mount Server
Step 2-5: PCI Expansion Card Installation
GS-R1270-RH provides expansion riser slots for one PCI-E x8 (x4 bandwidth) and one PCI-X
133MHz slots. To install the peripheral, please go through the following steps.
Note!! Before installing the expansion card, please check the card size limitation. Size limitation for
standard riser card is 182mm; and the size limitation for low profile riser card is 182mm.
Step 1 Loosen the riser bracket screws.
Step 2 Lift the riser bracket slightly, then pull it out from the server chassis.
Step 3 Unlock the screw on the riser bracket to remove the PCI bracket. Align the expansion card with
the guiding groove. Slide the expansion card into the slot until the card firmly seats.
Step 4 Reverse step 1 to 3 to reinstall riser bracket into the system module.
1
2
3
3
16
Hardware Installation Process
Step 2-6: Hard Disk Drive Installation
Step 1 Press the release button.
Step 2 Pull the blank out of the drive bay.
Step 3 Slide hard disk into blank.
Step 4 Secure it with screws.
Step 5 Slide the blank into the bay until it locks into place. Connect cable and power.
1
23
4
4
4
4
17
GS-R1270-RH Rack Mount Server
Step 2-7: FAN Duct Removal and Installation
Step 1 Pull up the cabled and align the fan duct with the guiding groove. Push down the fan duct into
system ntil the its firmly seats.
Step 2 Please push the cables into the gap between fan duct and power supply.
1
Guiding groove
System Appearance
18
3-1: Front View of GS-R1270-RH
Chapter 3 Appearance of GS-R1270-RH
X
Y
Z
[
X
Y
Z
[
Silm DVD-COMBO
Hot-Swap SATA HDDs
USB connectors
Front panel switch and LEDs
\
COM port (For Console redirection)
\
19
GS-R1270-RH Rack Mount Server
3-2: Rear View of GS-R1270-RH
X
Y
Z
[
\
]
^
_
`
Power
Mouse connector
Keyboard connector
COM port
VGA port
USB connectors
RJ45 LAN ports
Low-profile riser slot
Full-height riser slot
XY_`
^
\[
]
Z
20
LED Description
3-3: Switch and LED Indicators Introduction
Power Button
NMI
HDD
LAN1/2 LED ID Switch
Name
Power
HDD
ID
(Identification)
Error
Color Condition Description
Green On Power On
Green Blink Sleep (S1)
-- Off Power Off (S4/S5)
Green Blink Hard Disk Drive Access
-- Off No Access and No HDD Fault
Blue On Unti selected for identification
-- Off No identification
Yellow On IPMI shows the event log.
- Off No event log in IPMI
ID LED
Error
ID
2
1
NMI
ID
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55

Gigabyte GS-R1270-RH Owner's manual

Type
Owner's manual

Gigabyte GS-R1270-RH is a 1U Rack Mount Server with various advanced features:

  • Supports dual Intel Xeon LGA771 processors, providing high computing power and efficiency.
  • Equipped with a serverboard that offers flexible expansion options, allowing for customization and scalability.
  • Supports up to 32GB of DDR2 ECC Registered memory, ensuring reliable data handling and fast performance.
  • Features hot-swappable hard disk drive bays for easy maintenance and data protection.
  • Includes a rich set of I/O ports, including USB, serial, and Ethernet, for seamless connectivity.
  • The system is designed with a sturdy chassis, ensuring durability and protection in a rack-mounted environment.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI