3. Water inlet and chilled water outlet is 3/8” OD tube (or 1/4” NCT).
8. WARNING: Failure to follow current Acorn Drinking Fountains installation instructions or using
chiller in a manner not approved by Acorn Drinking Fountain will render warranty void.
4. Completely flush supply lines of all foreign debris before connecting to chiller. Water chiller is
designed to be free of problems with taste, odor, or sediment.
2. Remove front panel of chiller and make the necessary electrical connections (per the chiller data
label) including the ground connection. Make sure the supply power is off.
4. Provide power to chiller and make sure until begins to function.
CLEANING & MAINTENANCE GUIDE:
INSTALLATION:
5. Connect the outlet on top of the chiller to the fixture(s) requiring chilled water. All tubing supplying
chilled water must be covered with appropriate insulation to maintain temperature and avoid
condensation.
4. Connect the water supply stop (by others) to the inlet on top of the chiller. Make sure the water
supply lines are thoroughly flushed of any debris before connecting to chiller.
2. Excess dirt or poor ventilation will cause the compressor overload protector to turn the
compressor off and it will cycle on and off with no cold water coming out of bubbler. Periodically
clean with vacuum cleaner, air hose or brush the condenser fins and cabinet ventilation louvers.
In environments where dirt and dust is more prevalent, clean more frequently.
7. This unit must be grounded per the requirements of applicable electrical codes.
6. Power supply must be identical in voltage, cycle and phase to that specified on the chiller data
plate.
IMPORTANT:
2. Provide 4” minimum clear space on fixture top and front to allow for proper ventilation.
5. All burrs must be removed from outside of cut tubes before inserting into all components.
9. Chiller operates within water pressure range of 20 to 105 psig. Acorn Drinking Fountains will not
warranty chiller damages when connected to supply lines with flow pressure lower that 20 psig
or higher than 105 psig. A pressure regulator must be furnished by others on supply line if inlet
pressure is greater than 105 psig.
10. Remote water chiller is intended for indoor installation (fixture has not been rated for outdoor
installation).
3. Reinstall front panel with six sheet metal screws.
6. Tubing connections to fixtures should be direct and no longer than seven feet.
1. Water Supply Service Stop Valve, Water Connections and Electrical Connections to be supplied
by others in accordance with local codes.
1. Locate chiller where there is 4 inches of space in front and above the chiller for proper
ventilation.
START UP:
1. Before connecting power supply, but after thoroughly flushing the supply line and connecting it
to the chiller, turn on building water supply and check all connections for leaks.
2. Air within the water chiller system or the structure supply piping will cause an irregular outlet
stream until purged out by incoming water. Cover the outlet of fixture to which to which chiller is
connected with a clean cup(or similar object) is recommended when first activating water chiller
to prevent excessive splashing. Activate fixture valve until steady water stream is achieved.
3. Recheck all water connections with water flowing through system for leaks.
1. Motors have lifetime lubrication and do not require scheduled maintenance.
INSTALLATION/MAINTENANCE INSTRUCTIONS
CONTEMPORARY WATER COOLERS
INSTALLATION/MAINTENANCE INSTRUCTIONS
DRINKING FOUNTAINS
A910.8A
Page 3 of 7
Revised: A-02/14/22
7020-900-001
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA