7. Make connections to the Chiller Unit as required to supply chilled water to the Fountain. Water line
from the chiller to fountain should be covered with sponge rubber or ice water type insulation of
adequate thickness.
INSTALLATION:
2. Place the Chiller Unit onto the base pan of the Fountain Frame Assembly.
3. Recheck all water and drain connections with water flowing through system.
3. Install the Filter Cartridge Valve Bracket Assembly on the lower frame member, this must not
hang past the frame member and interfere with ADA access.
2. Water supply is 3/8” copper tube (Fountain). Waste is 1-1/4” OD female slip joint connection.
3. Completely flush supply lines of all foreign debris before connecting to fixture. Optional water filter
is available should there be problems from the water supply with taste, odor, color, or sediment.
4. WARNING: Warranty is voided if installation is not made following current Murdock Manufacturing
installation instructions and if components are assembled to the fixture that are not approved by
Murdock Manufacturing.
5. Secure the Fountain to the Frame Assembly using the supplied #10-32 screws and washers.
The screws need to pass through the tab and into the frame containing the captive nut. Tighten the
screws to pull the Fountain flush with the wall.
8. Make up 1-1/4” o.d. p-trap waste connection.
4. Securely hang the Fountain Assembly on the top flange of the Frame Assembly making sure that
the flanges engage.
9. Thoroughly flush the supply line, connect water supply to the Fountain.
1. Waste P-Trap and Water Supply Service Stop Valve to be supplied by others in accordance with
local codes.
6. Install water supply and drain as required per Figure A rough-in dimensions.
START UP:
2. Air within the Fountain or the structure supply piping will cause an irregular outlet stream until
purged out by incoming water.
4. Install Removable Access Covers to the Fountain top & bottom Mounting Frame Bracket,
install the supplied #8-32 screws & washers from the bottom & top of the Removable Access
Covers.
1. Install the Mounting Frame Assembly for the Chilled Fountain. Center the Frame Assembly and
securely install per Rough-In number 7020-006-001 Figure A. (All frame mounting hardware is to
be supplied by others, screws preferred).
1. Before assembling bottom & top covers to the Fountain, but after thoroughly flushing the supply
line and connecting it to the fixture, turn on building water supply and check all connections for
leaks.
5. Fixture operates within water pressure range of 20 to 105 psig. Murdock Manufacturing will not
warranty fixtures damaged when connected to supply lines with flow pressure lower that 20 psig or
higher than 105 psig. A pressure regulator must be furnished by others on supply line if inlet
pressure is greater than 105 psig.
IMPORTANT:
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
DRINKING FOUNTAINS
AI81.8
Page 3 of 6
Revised: 07/25/18
7020-007-001
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of