Giles GIDC -6DT User manual

Category
Food warmers
Type
User manual

This manual is also suitable for

Giles Enterprises, Inc.
An ISO9001 Registered Company
2750 Gunter Park Drive West Montgomery, AL 36109 USA
Phone: (334) 272-1457 Fax: (334) 272-3518 Internet: www.gilesent.com
Service Hotline (Toll Free): 1-800-554-4537 (USA & Canada Only)
Form No. 64304 (Release date: 08/12/09)(Revision Level: C)
GIDC -6DT, GIDC-4DT,
GIDC-6ST, & GIDC-
4ST
Operations & Service Manual
FOODSERVICE EQUIPMENT
Model: GIDC-6DT
Model: GIDC-4DT
Model: GIDC-4STModel: GIDC-6ST
LIMITED WARRANTY
Subject to the terms and conditions of this Limited Warranty as herein stated, all Giles Enterprises,
Inc., Foodservice Equipment and parts purchased new from an authorized Giles Enterprises, Inc.,
representative are warranted as to defects in material or workmanship for a period of 12 months
from the date of installation, provided, however, that with regard to labor costs in connection with
this warranty, see below. All installations must be made by a qualified installing agency in accor-
dance with all applicable codes and/or regulations in the jurisdiction in which installed. Limited war-
ranty coverage is extended to the original owner only and is void if the unit is resold.
During the Limited Warranty period, Giles Enterprises, Inc. will replace or recondition, at its factory,
any part or parts of this unit which Giles Enterprises, Inc. inspectors judge defective, provided the
unit has been subjected to normal usage, properly installed, operated and serviced. This Limited
Warranty does not cover cosmetic damage, and damage due to acts of God, accident, misuse, alter-
ation, negligence, abuse of the Giles Foodservice Equipment or the use of unorthodox repair meth-
ods. All parts replaced under this Limited Warranty carry only the unexpired term of this Limited
Warranty. Limited Warranty service may be furnished only by an authorized Giles Enterprises, Inc.,
representative.
If Limited Warranty service is requested, Giles Enterprises, Inc., will send factory-authorized serv-
ice representatives to repair, recondition, replace or inspect units of its manufacture with such labor
being rendered without cost to owner for ninety (90) days from the date of installation. Otherwise,
service, including labor and transportation charges or other expenses, in connection with the
removal or installation of any part or parts supplied under this Limited Warranty, are specified on the
original sales contract between the purchaser and the authorized Giles Enterprises, Inc., represen-
tative.
Giles Enterprises, Inc. reserves the right to change or improve its equipment and parts in any way
without obligation to alter such equipment or parts previously manufactured.
Giles Enterprises, Inc. makes no further warranties, express or implied including implied warranties
of merchantability or fitness for a particular purpose, and has no other obligation or liability not
specifically stated herein.
Repair or replacement as provided under this Limited Warranty is the exclusive remedy. Giles
Enterprises, Inc., shall not be liable for any incidental or consequential damages for breach of any
express or implied warranty on this product, except to the extent prohibited by applicable law. Any
implied warranty of merchantability or fitness for a particular purpose on this product is limited in
duration to the duration of this Limited Warranty.
Used Giles Enterprises, Inc., Foodservice Equipment or parts or Giles Enterprises, Inc., Foodservice
Equipment or parts not purchased from an authorized Giles Enterprises, Inc., representative, carry
no warranties, express or implied.
iii
Model: GIDCTable Of Contents
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Safety Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Specific Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1-01. Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1-02. Standard Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1-03. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1-03.01. Overall Dimensions for GIDC-6DT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1-03.02 Overall Dimensions for GIDC-4DT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1-03.03 Overall Dimensions for GIDC-6ST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1-03.04 Overall Dimensions for GIDC-4ST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1-03.05. Regulatory Listings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1-03.06. Unit Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2-01. Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2-02. Location and Clearances. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2-02.01 GIDC-6DT Clearances. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2-02.02 GIDC-4DT Clearances. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2-02.03 GIDC-6ST Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2-02.04 GIDC-4ST Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2-03. Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2-04. Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3-01. GIDC Double Tier Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3-02. GIDC Single Tier Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4. Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4-01. Controller Buttons and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4-02. Operating Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4-03 Starting Heat Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4-04 Stopping Heat Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4-05 Setting Operating Temperture. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4-06 Setting Low Temperature Fault Alarm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4-07 Synchronize Heater Plate Temperature With Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4-08 Set controller to read in Farenheit or Celcius . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4-09 Normal Shut Down Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4-10 Emergency Shut-Down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
iv
Model: GIDC Table Of Contents
5. Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5-01. Cleaning Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6-01. Troubleshooting Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
7. Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
7-02. Lighting and Upper Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
7-03. Control Cabinet Internal Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
7-04. Control Cabinet External Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
v
Model: GIDC-6DT, GIDC-4DT,
GIDC-6ST, & GIDC-4ST
Safety
Safety Overview
Safety
The instructions contained in this manual have been prepared to assist you in learning the proper proce-
dures for installing and servicing your unit.
Throughout this manual, safety precautions are identified through the use of the safety alert symbol and
three signal words: DANGER, WARNING, and CAUTION. All safety alert information precedes the
step(s) to which they apply. Suggested, recommended, or other noteworthy information is identified
through the use of NOTES. Additionally, certain words are used to indicate a specific meaning or to add
emphasis.
The following words are used as indicated throughout the manual:
Shall: understood to be mandatory.
Should: understood to be advisory.
May: understood to be permissive.
Will: indicates a future event/condition to occur.
or
(Safety Alert Symbol)
Used in conjunction with signal words (DANGER, WARNING, or CAUTION) to alert you of potential per-
sonal injury hazards, immediately preceding precautionary measures that pertain to subsequent step(s).
Obey all safety messages that follow this symbol to avoid possible injury or death. Failure to adhere to
safety precautions identified by the safety alert symbol may also void the warranty.
!!
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Use of this is limited to the most extreme situations.
!
DANGER
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
!
WARNING
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
Also used to alert against unsafe practices.
!
CAUTION
When used without the safety alert symbol, CAUTION indicates a potentially hazardous situation
which, if not avoided, may result in equipment/property damage, and void the warranty.
CAUTION
NOTE:
Identifies suggested, recommended, or other noteworthy information.
vi
Model: GIDC-6DT, GIDC-4DT,
GIDC-6ST, & GIDC-4ST
Safety
Specific Safety Precautions
For your safety, please observe the following precautions when operating or servicing your Holding
Cabinet. Read the following important safety information to avoid personal injury and/or damage to the
equipment.
Always disconnect the source of the main power before removing any service covers.
Failure to comply with these DANGER notices will result in death or serious injury, equipment/property
damage, and void the warranty.
!
DANGER
DO NOT use or store gasoline or other flammable liquids or vapors in the vicinity of this or any other
appliance!
Consult a qualified electrician to ensure all electrical specifications have been met and the unit is prop-
erly grounded.
Before installing or servicing this equipment, read the contents of this manual thoroughly.
Improper installation, adjustment, alteration, service or maintenance could result in death or serious
injury, equipment/property damage, and void the warranty.
Failure to comply with these WARNING notices could result in death or serious injury and
equipment/property damage.
!
WARNING
vii
Model: GIDC-6DT, GIDC-4DT,
GIDC-6ST, & GIDC-4ST
Safety
The Giles GIDC must remain in the horizontal position.
Exercise care when lifting or moving the unit. See Section 1-3.3. for unit weights.
Exercise care when removing the wooden shipping crate from around the unit.
The Deli Case and its parts are HOT!
•• Temperatures on the glass surfaces may exceed 150°F (65.5°C).
•• Exercise caution when operating, loading/unloading food, cleaning or servicing.
•• Wearing of thermal oven mitts is recommended.
Allow the unit to thoroughly cool before cleaning or servicing.
Food products must reach an internal temperature compliant with local health code requirements
before placing in the Giles Heated Case.
Food products must be maintained at a temperature of 140°F (60°C) minimum while inside the Giles
Heated Case. Failure to comply could violate local health codes.
During cleaning of the Giles Deli Case:
•• DO NOT steam clean.
•• DO NOT use products containing chlorine.
•• DO NOT use abrasive products, steel wool or scouring pads.
Always use containers that can withstand temperature of 250ºF (121ºC).
Proper temperature range is dependent upon the amount and type of product contained in the Giles
Heated Case.
Using a Food Thermometer, periodically check that food products on each rack are being maintained at a
temperature compliant with local health codes.
Comply with all appropriate state and/or local heath regulations regarding the cleaning and sanitation of
equipment.
Please ensure this appliance is electrically grounded and installed in accordance with local codes, or in
the absence of local codes, with the National Electrical Code ANSI/NFPA No. 70-1984.
Failure to comply with these CAUTION notices may result in equipment/property damage and void the
warranty.
!
CAUTION
viii
Model: GIDC-6DT, GIDC-4DT,
GIDC-6ST, & GIDC-4ST
Safety
NOTE:
If the shipping crate is damaged, immediately inspect the unit and notify the carrier of any damage to
the unit.
To aid the electrician, an electrical wiring diagram is contained in this manual. Refer to the wiring dia-
gram during installation or servicing.
For difficult areas, a mild biodegradable nontoxic degreaser (such as Clear Magic or Simple Green) may
be used.
Allow the tier to be used in the Giles Deli Case to preheat for approximately 20 minutes.
1
Model: GIDC-6DT, GIDC-4DT,
GIDC-6ST, & GIDC-4ST
Introduction
Congratulations on the purchase of your new Giles Island Deli Case (GIDC) with the either Double Tier
(DT) or Single Tier (ST) manufactured by Giles Enterprises, Inc., Montgomery, Alabama (USA), hereafter
referred to as "Giles". Proper care and maintenance of these units will ensure years of trouble-free service.
The Giles Island Deli Case has been developed with flexibility in mind. It was designed to maximize menu
selections, while keeping the food products fresh and maintaining them at the proper serving tempera-
ture, just waiting for your customers to enjoy.
To help protect your investment in this equipment, we recommend taking a few moments to familiarize
yourself with the installation, cleaning and maintenance procedures contained in this manual. Read these
instructions before installation and use. Adherence to these recommended procedures minimizes the
potential for costly "down-time" and equipment repairs. Please retain this manual for future reference.
Temperature Controls
Electronic Controller
-controls temperature setting for specific tier
-sounds alarm if a zone drops below a specified temperature. (see operations section)
Heated Glass
Tempered glass for easy cleaning.
Lights
GIDC-6DT(24) 13 watt coated flourescent lights.
GIDC-4DT(16) 13 watt coated flourescent lights.
GIDC-6ST(12) 13 watt coated flourescent lights.
GIDC-4ST(8) 13 watt coated flourescent lights.
1. Introduction
1-01. Construction
1-02. Standard Features
The Giles Island Deli Case exterior is constructed of stainless steel with clear tempered, heated, glass
that allows for even heating. FDA approved Lexan side boards are used to provide maximum viewing
from either side of unit while protecting your products.
2
Model: GIDC-6DT, GIDC-4DT,
GIDC-6ST, & GIDC-4ST
Introduction
1-03. Specifications
The following section gives various specifications of the unit.
ELECTRONIC
CONTROLLERS
HEATER SWITCH
LIGHT SWITCH
SERVICE BOX FOR
ELECTRICAL CONNECTION
D
26
660.4
HEATED GLASS
38 1/16
967.36
29 9/16
750.95
41 9/16
1055.75
32
812.76
HEATED GLASS
67 11/16
1719.54
31 1/16
788.22
49 1/4
1250.98
65 3/8
1661.17
50 1/16
1270.94
44
1116.81
HEATED GLASS
44
1117.15
HEATED GLASS
9
229.16
10 1/16
255.91
0 TO COMBUSTIBLES
0 TO COMBUSTIBLES
BUSTIBLES
0 TO COMBUSTIBLES
1-03.01. Overall Dimensions for GIDC-6DT
1-03.02. Overall Dimensions for GIDC-4DT
67 11/16
1719.23
31 1/16
788.25
49 1/4
1250.68
29 9/16
750.95
38 1/16
967.36
65 9/16
1665.35
74 1/16
1881.76
65 3/8
1660.86
ELECTRONIC
CONTROLLERS
SERVICE BOX FOR
ELECTRICAL CONNECTION
LIGHT SWITCH
HEATER SWITCH
26
660.4
HEATED GLASS
32
812.8
HEATED GLASS
68
1727.2
HEATED GLASS
68
1727.2
HEATED GLASS
9 1/16
230.07
10 1/8
256.82
USTIBLES
0 TO COMBUSTIBLES
0 TO COMBUSTIBLES
0 TO COMBUSTIBLES
3
Model: GIDC-6DT, GIDC-4DT,
GIDC-6ST, & GIDC-4ST
Introduction
1-03.03. Overall Dimensions for GIDC-6ST
1-03.04. Overall Dimensions for GIDC-4ST
RELEASE FOR PRODUCTION
A
TO COMBUSTIBLES
0 TO COMBUSTIBLES
0 TO COMBUSTIBLES
0 TO COMBUSTIBLES
58
1473.34
38 1/16
967.36
29 9/16
750.95
32
812.8
HEATED GLASS
LIGHT SWITCH
HEATER SWITCH
ELETRONIC
CONTROLLER
55 1/2
1410.34
74 1/16
1881.76
65 9/16
1665.35
SERVICE BOX FOR
ELECTRICAL CONNECTIONS
31 1/16
788.25
68
1727.2
HEATED GLASS
RESTRICTED CONFIDENTIAL DOCUMENT
THIS DRAWING AND ALL THE INFORMATION SHOWN HEREON ARE THE
EXCLUSIVE PROPERTY OF GILES ENTERPRISES, INC. AND ARE SUBMITTED ONLY
ON A CONFIDENTIAL BASIS. THE RECIPIENT AGREES NOT TO REPRODUCE THE
DRAWING, TO RETURN IT UPON REQUEST, AND THAT NO DISCLOSURE OF THE
D
ENTERPRISES, INC.
BY
SYM.
DATE
REVISIONS
DESCRIPTION
RELEASE FOR PRODUCTION
A
10/03/07 JRL ECO1147
LIGHT SWITCH
HEATER SWITCH
ELECTRONIC
CONTROLLER
SERVICE BOX FOR
ELECTRICAL CONNECTION
D
29 9/16
750.95
57 13/16
1468.71
32
812
HEATED GLASS
0 TO COMBUSTIBLES
0 TO COMBUSTIBLES
41 9/16
1055.75
44
1116.39
HEATED GLASS
0 TO COMBUSTIBLES
0 TO COMBUSTIBLES
55 1/2
1410.34
31 1/16
788.25
38 1/16
967.36
50 1/16
1271.61
4
Model: GIDC-6DT, GIDC-4DT,
GIDC-6ST, & GIDC-4ST
Introduction
1-03.05. Regulatory Listings
ETL (Tested to UL197)
ETL Sanitation (Test to NSF)
Unit Crated Weight
Uncrated Weight
(without product)
GIDC-6DT 623lbs. (283kg) 376lbs. (171kg)
GIDC-4DT 502lbs. (228kg) 326lbs. (148kg)
GIDC-6ST 475lbs.(215kg) 228lbs. (103kg)
GIDC-4ST 355lbs (161kg) 179lbs (81kg)
1-03.06. Unit Weights
5
Model: GIDC-6DT, GIDC-4DT,
GIDC-6ST, & GIDC-4ST
Installation
2. Installation
This section provides a summary of procedures necessary to install your new Giles Island Deli Case,
Model GIDC. Before installing or servicing this equipment, thoroughly read the contents of this manual.
Following these procedures will help ensure a safe and proper installation.
Your unit should arrive packaged in a wooden crate, covered with plastic shipping wrap, and secured to a
wooden platform by means of high-tensile strength strapping. Perform the following steps to uncrate the
unit:
1. Position the packaged GIDC in an area with sufficient room for unpacking.
2. Cut and remove the plastic shipping wrap and any high-tensile strength straps from the exterior of the
wooden crate.
3. Carefully use a hammer and pry bar to remove the wooden crate from around the unit.
4. Cut and remove the plastic shipping wrap and high-tensile strength strapping that secures the unit to
the wooden platform.
5. Before installing, check the unit for damage. If unit was damaged during shipment, notify the carrier
immediately and file a claim.
6. Carefully remove the unit from the wooden platform and place at the installation site.
2-01. Unpacking
NOTE:
If the crate is damaged, immediately inspect the unit and notify the carrier of any damage to the unit.
Exercise care when lifting or moving the unit. Please see Section 1-03.03 for unit weights.
Exercise care when removing the wooden crate from around the unit.
Failure to comply with these CAUTION notices may result in minor or moderate injury,
equipment/property damage, and void the warranty.
!
CAUTION
6
Model: GIDC-6DT, GIDC-4DT,
GIDC-6ST, & GIDC-4ST
Installation
1. Select a location with adequate space to properly operate and service the unit.
2. Maintain the clearances shown in the following Sections.
2-02. Location and Clearances
67 11/16
1719.23
31 1/16
788.25
49 1/4
1250.68
29 9/16
750.95
38 1/16
967.36
65 9/16
1665.35
74 1/16
1881.76
65 3/8
1660.86
ELECTRONIC
CONTROLLERS
SERVICE BOX FOR
ELECTRICAL CONNECTION
LIGHT SWITCH
HEATER SWITCH
26
660.4
HEATED GLASS
32
812.8
HEATED GLASS
68
1727.2
HEATED GLASS
68
1727.2
HEATED GLASS
9 1/16
230.07
10 1/8
256.82
0 TO COMBUSTIBLES
0 TO COMBUSTIBLES
0 TO COMBUSTIBLES
0 TO COMBUSTIBLES
DO NOT MODIFY, ALTER OR ADD ATTACHMENTS TO THIS EQUIPMENT.
DO NOT MOUNT ON COUNTER. UNIT IS FOR FLOOR MOUNTING ONLY.
!
WARNING
2-02.01 GIDC-6DT Clearances
7
Model: GIDC-6DT, GIDC-4DT,
GIDC-6ST, & GIDC-4ST
Installation
2-02.02 GIDC-4DT Clearances
ELECTRONIC
CONTROLLERS
HEATER SWITCH
LIGHT SWITCH
SERVICE BOX FOR
ELECTRICAL CONNECTION
D
26
660.4
HEATED GLASS
38 1/16
967.36
29 9/16
750.95
41 9/16
1055.75
32
812.76
HEATED GLASS
67 11/16
1719.54
31 1/16
788.22
49 1/4
1250.98
65 3/8
1661.17
50 1/16
1270.94
44
1116.81
HEATED GLASS
44
1117.15
HEATED GLASS
9
229.16
10 1/16
255.91
0 TO COMBUSTIBLES
0 TO COMBUSTIBLES
0 TO COMBUSTIBLES
0 TO COMBUSTIBLES
2-02.03 GIDC-6ST Clearances
0 TO COMBUSTIBLES
0 TO COMBUSTIBLES
0 TO COMBUSTIBLES
0 TO COMBUSTIBLES
58
1473.34
38 1/16
967.36
29 9/16
750.95
32
812.8
HEATED GLASS
LIGHT SWITCH
HEATER SWITCH
ELETRONIC
CONTROLLER
55 1/2
1410.34
74 1/16
1881.76
65 9/16
1665.35
SERVICE BOX FOR
ELECTRICAL CONNECTIONS
31 1/16
788.25
68
1727.2
HEATED GLASS
8
Installation
2-03. Electrical Requirements
The unit must be adequately and properly grounded. Improper grounding may result in electrical shock. Always refer to
your local electrical code to ensure proper grounding of this or any other electrical equipment. Always consult with an
electrician or other qualified service person to ensure breakers and wiring are of sufficient rating and gauge for the
equipment being operated.
I
mproper installation, adjustment, alteration, service or maintenance could result in death or serious injury, equip-
ment/property damage, and void the warranty.
!
WARNING
2-02.04 GIDC-4ST Clearances
Model: GIDC-6DT, GIDC-4DT,
GIDC-6ST, & GIDC-4ST
BY
SYM.
DATE
REVISIONS
DESCRIPTION
ECO #
RELEASE FOR PRODUCTION
A
10/03/07 JRL ECO1147
LIGHT SWITCH
HEATER SWITCH
ELECTRONIC
CONTROLLER
SERVICE BOX FOR
ELECTRICAL CONNECTION
D
29 9/16
750.95
57 13/16
1468.71
32
812
HEATED GLASS
0 TO COMBUSTIBLES
0 TO COMBUSTIBLES
41 9/16
1055.75
44
1116.39
HEATED GLASS
0 TO COMBUSTIBLES
0 TO COMBUSTIBLES
55 1/2
1410.34
31 1/16
788.25
38 1/16
967.36
50 1/16
1271.61
9
Model: GIDC-6DT, GIDC-4DT,
GIDC-6ST, & GIDC-4ST
Installation
Model Voltage Hz Phase
AMPS
Circuit
Breaker
Required
(amps)
L1 L2
GIDC-6DT 208/240 60 1 18.6 18.6 25
GIDC-4DT 208/240 60 1 16.6 16.6 25
GIDC-6ST 208/240 60 1 11 11 15
GIDC-4ST 208 60 1 9.5 9.5 15
The unit must be properly grounded and all electrical specifications must be met during installation.
I
mproper installation, adjustment, alteration, service or maintenance could result in death or serious injury,
equipment/property damage, and void the warranty.
!
WARNING
1. Install appropriate circuit breaker in main breaker box. (See Table 2.03)
2. Connect flexible conduit to service enterance box located on top of the unit to the main breaker box.
Allow enough conduit so Deli Case can be moved for cleaning.
3. Route appropriate size Line 1, Line 2, Neautral, and Ground wire from the circuit breaker to the Deli
Case.
4. Connect wires from circuit breaker to wires in service entrance box with appropriate size wire nuts.
(See Figure)
2-04. Electrical Connections
Ground Wire
White (Neutral)Wire
Black Wire
Red Wire
Installation
Model: GIDC-6DT, GIDC-4DT,
GIDC-6ST, & GIDC-4ST
10
Notes:
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Giles GIDC -6DT User manual

Category
Food warmers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI