Pulsar RS4281GD Operating instructions

Category
Rack accessories
Type
Operating instructions
MOUNTING INSTRUCTIONS
ENGLISH v1.1
code: RS4281GD
Name: RACK cabinet, floor standing, ready-to-assemble 42U/800x1000
IM RS4281GD
Edition: 2 from 25.02.2016
Supercedes edition: 1 from 17.06.2013
EN*
1. Application:
The RACK 19” cabinet enables integration of the CCTV, KD, SSWiN, RTV, and LAN systems in medium and large companies. It
is designed for mounting of devices in a 19” enclosures. The RACK cabinets ensure an aesthetic mounting of devices and protect them
from mechanical damage.
2. Technical parameters:
TECHNICAL PARAMETERS
Mounting dimensions:
W=19", H=42U
External dimensions:
W=800, H=2055, D=1000 [mm, +/-2]
Net/gross weight:
134,5 / 144,5 [kg]
Construction:
- RACK profiles: cold rolled steel SPCC 2mm RAL 9004 screwed
- transverse profiles: cold rolled steel SPCC 1,5mm RAL 9004 - screwed
- cabinet frame: cold rolled steel SPCC 1,2mm RAL 9004 - welded
- front door: 5mm tempered glass / SPCC 1,2mm RAL 9004 - hinged
- side door: cold rolled steel SPCC 1,2mm RAL 9004 - latched
- rear door: cold rolled steel SPCC 1,2mm RAL 9004 - hinged
Static load:
800 kg (with leveling legs)
Application:
indoor, IP20
Notes:
- the possibility to change the spacing between the front and rear RACK profiles
- ventilation holes in the top and bottom plate of the cabinet and in the front door
- the possibility of mounting a panel of fans to the upper plate RAWP (max. 3 pieces.)
- cable glands in the bottom and top plate of the cabinet
- two vertical cable organizers mounted in front of the cabinet
- the set includes 4 wheels without locking, 4 leveling legs
- the possibility of mounting the plinth with a height of 100mm - RAC1810
- front door locked with a key (two included)
- rear door locked with a key (two included)
- side door - the possibility of mounting a lock - RAZB16
- cabinet for assembling
Certificates, declarations
RoHS
3. The RACK cabinet construction
Top plate
Rear door
Cabinet frame
RACK profile
Distance
Transverse profile
Side door
Vertical cable organizer
Front door
Bottom plate
Wheel 2” without locking
Leveling leg
4. The RACK cabinet mounting instructions:
The RACK 19" Standing Cabinet for assembling is supplied in 5 separate packages.
4.1) Lay horizontally two frames of the RACK cabinet (package 2/5 and 3/5)
Fig.1
4.2) Connect the bottom plate and the top plate to the cabinet frame from the left side and the right side of the RACK cabinet,
respectively. (package 1/5). Use bolts with nuts (16 pcs - package 1/5). Mount wheels and leveling legs to the bottom plate of the
cabinet (package 1/5).
Fig.2
4.3) Place the RACK cabinet vertically.
Fig.3
4.4) Mount two cage nuts inside (at the front and back) the cabinet frames at the 1/4, 1/2 and 3/4 height of the cabinet, as shown in
the Fig.4.
Fig.4
4.5) Mount two cage nuts at the front and back of the Transverse profiles (package 1/5), as in the Fig.5.
Fig.5
4.6) Install transverse profiles from the inside, as shown in the Fig.6.
Fig.6.
4.7) Screw distances to the transverse profiles, as shown in the Fig.7.
Fig.7
4.8) Screw the RACK profiles to the mounted distances, as shown in the Fig.8
.
Fig.8
4.9) Screw the vertical cable organizers to the mounted distances as in the Fig.9
Fig.9
4.10) Mount the side, rear and front door to the RACK cabinet - Fig.10
Fig.10
MANUFACTURER
Pulsar
Siedlec 150,
32-744 Łapczyca
Phone 14-610-19-40, Fax 14-610-19-50
e-mail: biuro@pulsar.pl, sale[email protected]
http:// www.pulsar.pl, www.zasilacze.pl
WARRANTY:
12 months from the date of purchase
WARRANTY VALID only upon presentation of the original invoice
1 / 1