c) Changing the operating mode
The code lock features two operating modes. "Single user" (8900 + #) and "Multi user" (8901 +
#) mode can be enabled by entering the corresponding code in brackets.
When you switch to another mode, all user codes will be deleted and factory settings
will be automatically restored. The master code will not be reset. Before switching to
single user mode, check that the master code is four digits long. The master code
and user codes must be four digits long. Codes with more than four digits are invalid.
If the master code has more than four digits, change it to a four-digit code. If the
master code is not four digits long, factory settings will not be restored when you
switch modes.
Single user mode:
In this mode, you can only program one 4-digit user code (0000 to 9999). Everyone who knows
this code can use it to activate a door opener that is connected to the code lock.
When you switch modes, it takes approximately 2–3 seconds for the code lock to be reset. Do
not enter a code during this time. Wait until the code lock beeps twice to indicate that it has been
reset.TheyellowLEDwillashrapidlyforafewseconds.
"Auto entry" mode (see section I "Auto entry mode (automatic code recognition)") will be
automatically enabled and the relay will be enabled immediately after you enter the correct four-
digit code. It is not necessary to press the # key (hash key) after entering the user code. You can
changethissettingbydisablingautomaticcoderecognition.Inthiscase,youwillneedtoconrm
the user code by pressing the # key (hash key).
To switch to single-user mode, press the keys in the order shown in the left-hand diagram.
Follow the instructions on the right-hand side.
Enter the master code to enable programming mode (in this example, the
mastercodeisthefactorydefault,"0000").Pressthe*keytoconrmyour
entry. The code lock will beep twice and the yellow LED will stay constant
to indicate that programming mode is enabled.
#
Enter the mode switch code ("8900").
Pressthe#keytoconrmyourentry.Thecodelockwillswitchtosingle-
user mode and beep twice.
If the entry was incorrect or unsuccessful, the code lock will beep and the
yellowLEDwillashvetimes.
"Multi-user" mode:
In multi-user mode, you can program up to 100 different user codes. The codes can be 4–8 digits
long (e.g. 1234, 123456, 98765432).
57