Kichler Lighting 49880BK User manual

Type
User manual
IS-49880-US
Were here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
1) Slip xture[D] over post and mark posion of mounng
holes in post.
2) Remove xture from post.
3) Drill 3/16” dia holes in post at posions marked.
4) Grounding instrucons: (See Illus. a or b).
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector aer following the above steps. Never connect
ground wire to black or white power supply wires.
5) Make wire connecons. Reference chart below for
correct connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
6) Slip xture[D] over post and secure in place using
provided screws[A]. Screws should slip into holes drilled
in post.
7) Insert recommended bulb (Not supplied).
8) Place the glass[F] over the installed bulb and secure into
place using four (4) ball knobs[C] by threading on the
protruding studs.
9) Lower the top[E] onto the frame and secure into place
using the two (2) screws[B].
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
[A] Screws
[B] Screws
[C] Ball Knobs
[D] Fixture
[E] Top
[F] Glass
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
E
B
D
C
A
F
IS-49880-CB
Were here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
1) Slip xture[D] over post and mark posion of mounng
holes in post.
2) Remove xture from post.
3) Drill 3/16” dia holes in post at posions marked.
4) Grounding instrucons: (See Illus. a or b).
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector aer following the above steps. Never connect
ground wire to black or white power supply wires.
5) Make wire connecons. Reference chart below for
correct connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
6) Slip xture[D] over post and secure in place using
provided screws[A]. Screws should slip into holes drilled
in post.
7) Insert recommended bulb (Not supplied).
8) Place the glass[F] over the installed bulb and secure into
place using four (4) ball knobs[C] by threading on the
protruding studs.
9) Lower the top[E] onto the frame and secure into place
using the two (2) screws[B].
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
[A] Screws
[B] Screws
[C] Ball Knobs
[D] Fixture
[E] Top
[F] Glass
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
E
B
D
C
A
F
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Kichler Lighting 49880BK User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI