Date Issued: 10/02/17 IS-44116-CB
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starting and during the installation.
►
►
3
2
11
10
4
5
6
7
8
9
13
12
15
14
1
16
17
19
12
18
1) Rotatearmsofxture[16] as shown.
2) Take the arm assembly and lower onto the lower assembly[17]
angesandthreadthetwostems[18] into the lower assembly.
3) Take the three (3) ball knobs[19] and thread onto the three (3)
arms of the installed arm assembly.
4) Passxturewirefromthecoupling[1]ontopofxturethrough
a stem[2]andthreadedtubes[3]andscrewstemintocoupling.
NOTE:Threadlockingcompoundmustbeappliedtoallstem
threadsasnotedwitharrowsymboltopreventaccidentalrota-
tionofxtureduringcleaning,relamping,etc.
5) Passxturewirethroughdesiredamountofstemsandscrew
stemstogetherusingsuppliedshortthreadedtubes[3].
6) Passxturewirefromlaststemthroughrstloop[4]. Thread
rstloopontoendoflaststem.
7) Passxturewirethroughsecondloop[5]andthroughholein
Canopy[6].
8) (Ifsecondloopisalreadyattachedtocanopy,proceedtonext
step).Passthreadedpipeatendofsecondloopthroughhole
incanopy.Threadlockwasher[7]ontothreadedpipeprotruding
frominsidecanopy.Passxturewirethroughholeinhexnut
andthreadhexnut[8]ontoendofthreadedpipe.
9) Attachchainlink[9]tosmallloopatendofstemandtoloopon
canopy.
10) Findtheappropriatethreadedholesonmountingstrap[12].
Assemblemountingscrews[13] into threaded holes.
11) Attachmountingstraptooutletbox[14].Themountingstrap
canbeadjustedtosuitpositionofxtureusingthestrap
mountingscrews[15].
12)Groundinginstructions:(SeeIllus.AorB).
A) Onxtureswheremountingstrapisprovidedwitha
holeandtworaiseddimples.Wrapgroundwirefrom
outletboxaroundgreengroundscrew,andthreadinto
hole.
B) Onxtureswhereacuppedwasherisprovided.Attach
groundwirefromoutletboxundercuppedwasherand
greengroundscrew,andthreadintomountingstrap.
Ifxtureisprovidedwithgroundwire.Connectxtureground
wiretooutletboxgroundwirewithwireconnector.(Notpro-
vided.)Afterfollowingtheabovesteps.Neverconnectground
wiretoblackorwhitepowersupplywires.
13)Makewireconnections(connectorsnotprovided.)Reference
chartbelowforcorrectconnectionsandwireaccordingly.
14)Pushxturetoceiling,carefullypassingmountingscrews
throughholesincanopy.NOTE:Becertainwiresdonotget
pinchedbetweencanopyandceiling.
15) Use knobs[10]andlockwashers[11]tosecurecanopy.Tighten
tosecure.
16) Carefullyraiselowerassembly[17]tothexturearms.Thread
intheinnertubes[18].
17) Holdthearmsinplaceusingtheballknobs[19].
18) Insertrecommendedbulb(notsupplied).
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
A
B
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire