Application Note: Encore to Router Connections
Barco Media & Entertainment
11101 Trade Center Drive
Rancho Cordova, CA 95670
Page 4 of 6 Tel 916.859.2500 Fax 916.859.2515
www.barco.com
Lantronix Ethernet to Serial Cable Connection
Because Encore Controllers only have one RS-232 serial port (EXT COMM), an external device
(such as the Lantronix UDS200) is required for multiple RS-232 connections. The Lantronix
UDS200 connects to Encore via Ethernet, and provides two RS-232 ports.
The table below illustrates the pinouts on the UDS200’s serial connector. Data “direction”
information is provided from the point of view of the UDS200.
51
96
Ethernet
Encore Controller (SC or LC)
MatrixPRO SDI Router
Hub / Switch
Lantronix
UDS200
MatrixPRO Analog Router
Table 4. Lantronix pin connections
Pin Signal Description Note
1 CD Carrier Detect
2 RXD Received Data Receives data. Connects to router’s transmitting pin.
3 TXD Transmitted Data Sends data. Connects to router’s receiving pin.
4 DTR Data Terminal Ready
5 GND Signal Ground Connects to Ground Pin on Router
6 DSR Data Set Ready
7 RTS Request to Send
8 CTS Clear to Send
9 RI Unused
• Note: RS-232 cable requirements vary. Use the table in the following section for specific
cable requirements for various routers.