H3C S6861 Series Installation guide

Category
Network switches
Type
Installation guide

This manual is also suitable for

H3C S6861 Switch Series
Installation Guide
New H3C Technologies Co., Ltd.
http://www.h3c.com
Document version: 5W100-20190228
Copyright © 2019, New H3C Technologies Co., Ltd. and its licensors
All rights reserved
No part of this manual may be reproduced or transmitted in any form or by any means without prior written
consent of New H3C Technologies Co., Ltd.
Trademarks
Except for the trademarks of New H3C Technologies Co., Ltd., any trademarks that may be mentioned in this
document are the property of their respective owners.
Notice
The information in this document is subject to change without notice. All contents in this document, including
statements, information, and recommendations, are believed to be accurate, but they are presented without
warranty of any kind, express or implied. H3C shall not be liable for technical or editorial errors or omissions
contained herein.
Environmental protection
This product has been designed to comply with the environmental protection requirements. The storage, use,
and disposal of this product must meet the applicable national laws and regulations.
Preface
H3C S6861 Switch Series Installation Guide describes the appearance, installation, power-on,
maintenance, and troubleshooting of the H3C S6861 Switch Series.
This preface includes the following topics about the documentation:
• Audience.
• Conventions.
• Documentation feedback.
Audience
This documentation is intended for:
• Network planners.
• Field technical support and servicing engineers.
• Network administrators working with the S6861 switch series.
Conventions
The following information describes the conventions used in the documentation.
Command conventions
Convention Description
Boldface Bold
text represents commands and keywords that you enter literally as shown.
Italic
Italic text represents arguments that you replace with actual values.
[ ] Square brackets enclose syntax choices (keywords or arguments) that are optional.
{ x | y | ... }
Braces enclose a set of required syntax choices separated by vertical bars, from which
you select one.
[ x | y | ... ]
Square brackets enclose a set of optional syntax choices separated by vertical bars,
from which you select one or none.
{ x | y | ... } *
Asterisk marked braces enclose a set of required syntax choices separated by vertical
bars, from which you select a minimum of one.
[ x | y | ... ] *
Asterisk marked square brackets enclose optional syntax choices separated by vertical
bars, from which you select one choice, multiple choices, or none.
&<1-n>
The argument or keyword and argument combination before the ampersand (&) sign
can be entered 1 to n times.
# A line that starts with a pound (#) sign is comments.
GUI conventions
Convention Description
Boldface
Window names, button names, field names, and menu items are in Boldface. For
example, the
New User
window opens; click
OK
.
>
Multi-level menus are separated by angle brackets. For example,
File
>
Create
>
Folder
.
Symbols
Convention Description
WARNING!
An alert that calls attention to important information that if not understood or followed
can result in personal injury.
CAUTION:
An alert that calls attention to important information that if not understood or followed
can result in data loss, data corruption, or damage to hardware or software.
IMPORTANT:
An alert that calls attention to essential information.
NOTE:
An alert that contains additional or supplementary information.
TIP:
An alert that provides helpful information.
Network topology icons
Convention Description
Represents a generic network device, such as a router, switch, or firewall.
Represents a routing-capable device, such as a router or Layer 3 switch.
Represents a generic switch, such as a Layer 2 or Layer 3 switch, or a router that
supports Layer 2 forwarding and other Layer 2 features.
Represents an access controller, a unified wired-WLAN module, or the access
controller engine on a unified wired-WLAN switch.
Represents an access point.
Represents a wireless terminator unit.
Represents a wireless terminator.
Represents a mesh access point.
Represents omnidirectional signals.
Represents directional signals.
Represents a security product, such as a firewall, UTM, multiservice security
gateway, or load balancing device.
Represents a security module, such as a firewall, load balancing, NetStream, SSL
VPN, IPS, or ACG module.
Examples provided in this document
Examples in this document might use devices that differ from your device in hardware model,
configuration, or software version. It is normal that the port numbers, sample output, screenshots,
and other information in the examples differ from what you have on your device.
T
T
T
T




Documentation feedback
You can e-mail your comments about product documentation to info@h3c.com.
We appreciate your comments.
i
Contents
Preparing for installation ···································································· 1
Safety recommendations ············································································································· 1
Examining the installation site ······································································································· 1
Temperature/humidity ·········································································································· 2
Cleanliness ························································································································ 2
EMI ·································································································································· 2
Laser safety ······················································································································· 3
Installation tools ························································································································· 3
Installing the switch ·········································································· 4
Installing the switch in a 19-inch rack ····························································································· 4
Installation accessories ········································································································· 4
Rack-mounting procedures at a glance ···················································································· 6
Attaching the mounting brackets, chassis rails, and grounding cable to the chassis ··························· 7
Attaching the slide rails to the rack ························································································ 12
Mounting the switch in the rack ···························································································· 13
Grounding the switch by using a grounding strip ············································································· 14
Installing and removing a fan tray ································································································ 15
Installing a fan tray ············································································································ 15
Removing a fan tray ··········································································································· 16
Installing and removing a power module ······················································································· 16
Installing a power module ···································································································· 17
Removing a power module ·································································································· 18
Connecting the power cord ········································································································ 20
Connecting the power cord for a PSR250-12A/PSR250-12A1/PSR450-12A/PSR450-12A1 power module
····································································································································· 20

Connecting the power cord for a PSR450-12AHD power module ················································· 21
Connecting the DC power cord for a PSR450-12D power module ················································ 22
Verifying the installation ············································································································· 22
Accessing the switch for the first time ················································· 23
Setting up the configuration environment ······················································································ 23
Connecting the console cable ····································································································· 23
Serial console cable ··········································································································· 23
USB mini console cable ······································································································ 24
Connection procedure ········································································································ 24
Setting terminal parameters ······································································································· 26
Powering on the switch ············································································································· 26
Setting up an IRF fabric ··································································· 28
IRF fabric setup flowchart ·········································································································· 28
Planning IRF fabric setup ··········································································································· 29
Planning IRF fabric size and the installation site ······································································· 29
Identifying the master switch and planning IRF member IDs ······················································· 29
Planning IRF topology and connections·················································································· 30
Identifying physical IRF ports on the member switches ······························································ 31
Planning the cabling scheme ······························································································· 31
Configuring basic IRF settings ···································································································· 33
Connecting the physical IRF ports ······························································································· 33
Accessing the IRF fabric to verify the configuration ········································································· 33
Maintenance and troubleshooting ······················································ 35
Power module failure ················································································································ 35
Symptom ························································································································· 35
Solution ··························································································································· 35
Fan tray failure ························································································································ 35
Symptom ························································································································· 35
ii
Solution ··························································································································· 35
Configuration terminal issues ······································································································ 35
No display on the configuration terminal ················································································· 36
Garbled display on the configuration terminal ·········································································· 36
Appendix A Chassis views and technical specifications ·························· 37
Chassis views ························································································································· 37
S6861-54QF ···················································································································· 37
S6861-54QT ···················································································································· 38
S6861-30QF ···················································································································· 39
Technical specifications ············································································································· 40
Appendix B FRUs ··········································································· 43
Power modules ······················································································································· 43
Fan trays ································································································································ 44
Appendix C Ports and LEDs ····························································· 46
Ports ····································································································································· 46
Console port ····················································································································· 46
Management Ethernet port ·································································································· 46
USB port ························································································································· 47
SFP+ port ························································································································ 47
QSFP+ port ······················································································································ 49
1/10GBASE-T autosensing Ethernet port ················································································ 52
LEDs ····································································································································· 52
System status LED ············································································································ 52
SFP+ port LED ················································································································· 53
QSFP+ port LED ··············································································································· 53
Management Ethernet port LEDs ·························································································· 53
1/10GBASE-T autosensing Ethernet port LEDs ······································································· 54
Fan tray alarm LEDs ·········································································································· 54
Appendix D Cooling system ······························································ 55
1
Preparing for installation
H3C S6861 switch series includes the following models:
• S6861-54QF
• S6861-54QT
• S6861-30QF
Safety recommendations
To avoid any equipment damage or bodily injury caused by incorrect use, read the following safety
recommendations before installation. Note that the recommendations do not cover every possible
hazardous condition.
• Before cleaning the switch, remove all power cords from the switch. Do not clean the switch
with wet cloth or liquid.
• Do not place the switch near water or in a damp environment. Prevent water or moisture from
entering the switch chassis.
• Do not place the switch on an unstable case or desk. The switch might be severely damaged in
case of a fall.
• Ensure good ventilation of the equipment room and keep the air inlet and outlet vents of the
switch free of obstruction.
• Make sure the operating voltage is in the required range.
• To avoid electrical shocks, do not open the chassis while the switch is operating or when the
switch is just powered off.
• When replacing FRUs, including power modules and fan trays, wear an ESD wrist strap to
avoid damaging the units.
Examining the installation site
The switch must be used indoors.
Mount your switch in a rack and verify the following items:
• Adequate clearance is reserved at the air inlet and outlet vents for ventilation.
• The rack has a good ventilation system.
• Identify the hot aisle and cold aisle at the installation site, and make sure ambient air flows into
the switch from the cold aisle and exhausts to the hot aisle.
• Identify the airflow designs of neighboring devices, and prevent hot air flowing out of the bottom
device from entering the top device.
• The rack is sturdy enough to support the switch and its accessories.
• The rack is reliably grounded.
To ensure correct operation and long service life of your switch, install it in an environment that meets
the requirements described in the following subsections.
2
Temperature/humidity
Maintain appropriate temperature and humidity in the equipment room.
• Lasting high relative humidity can cause poor insulation, electricity leakage, mechanical
property change of materials, and metal corrosion.
• Lasting low relative humidity can cause washer contraction and ESD and cause problems
including loose screws and circuit failure.
• High temperature can accelerate the aging of insulation materials and significantly lower the
reliability and lifespan of the switch.
For the temperature and humidity requirements of different switch models, see "Appendix A Chassis
views a
nd technical specifications."
Cleanliness
Dust buildup on the chassis might result in electrostatic adsorption, which causes poor contact of
metal components and contact points, especially when indoor relative humidity is low. In the worst
case, electrostatic adsorption can cause communication failure.
Table 1 Dust concentration limit in the equipment room
Substance Concentration limit (particles/m³)
Dust
≤ 3 × 10
4
(no visible dust on the tabletop over three days)
NOTE:
Dust diameter ≥ 5 μm
The equipment room must also meet strict limits on salts, acids, and sulfides to eliminate corrosion
and premature aging of components, as shown in Tabl e 2 .
Table 2
Harmful gas limits in the equipment room
Gas Maximum concentration (mg/m
3
)
SO
2
0.2
H
2
S 0.006
NH
3
0.05
Cl
2
0.01
EMI
All electromagnetic interference (EMI) sources, from outside or inside of the switch and application
system, adversely affect the switch in the following ways:
• A conduction pattern of capacitance coupling.
• Inductance coupling.
• Electromagnetic wave radiation.
• Common impedance (including the grounding system) coupling.
3
To prevent EMI, use the following guidelines:
• If AC power is used, use a single-phase three-wire power receptacle with protection earth (PE)
to filter interference from the power grid.
• Keep the switch far away from radio transmitting stations, radar stations, and high-frequency
devices.
• Use electromagnetic shielding, for example, shielded interface cables, when necessary.
• To prevent signal ports from getting damaged by overvoltage or overcurrent caused by lightning
strikes, route interface cables only indoors.
Laser safety
WARNING!
• The switch is a Class 1 laser device.
• Disconnected optical fibers or transceiver modules might emit invisible laser light. Do not stare
into beams or view directly with optical instruments when the switch is operating.
Installation tools
No installation tools are provided with the switch. Prepare the following tools yourself:
• Flathead screwdriver
• Phillips screwdriver.
• ESD wrist strap.
• Marker.
4
Installing the switch
CAUTION:
Keep the tamper-proof seal on a mounting screw on the chassis cover intact, and if you want to open
the chassis, contact H3C for permission. Otherwise, H3C shall not be liable for any consequence
caused thereby.
Figure 1 Hardware installation flow
Installing the switch in a 19-inch rack
Installation accessories
Table 3 Installation accessories
Switch model Mounting brackets Rack mounting rail kit
S6861-54QF
S6861-30QF
1U high, one pair
(provided). See Figure 2.
•
1U high, including one pair of chassis rails and one
pair of long slide rails (provided). See Figure 5.
•
1U high, including one pair of chassis rails and one
pair of super-short slide rails (optional). See Figure 3.
Start
Install the switch
Ground the switch
Connect power cords
Verify the installation
Turn on the circuit
breakers
Operating correctly?
Turn off the circuit
breakers
Troubleshoot the switch
Yes
No
Install power modules
Install fan trays
End
5
Switch model Mounting brackets Rack mounting rail kit
S6861-54QT
1U high, one pair
(provided). See Figure 3.
•
1U high, including one pair of chassis rails and one
pair of long slide rails (provided). See Figure 5.
•
1U high, including one pair of chassis rails and one
pair of slide rails (optional). See Figure 4.
Figure 2 Mounting brackets
Figure 3 1U chassis rail and super-short slide rail
(1) Chassis rail (2) Super-short slide rail
Figure 4 1U chassis rail and slide rail
(1) Chassis rail (2) Slide rail
6
Figure 5 1U chassis rail and long slide rail
(1) Chassis rail (2) Long slide rail
Rack-mounting procedures at a glance
Figure 6 Rack-mounting procedure
NOTE:
If a rack shelf is available, you can put the switch on the rack shelf, slide the switch to an appropriate
location, and attach the switch to the rack with the mounting brackets.
Follow these guidelines when you install the switch in a 19-inch rack:
• The distance between the front and rear posts of the rack must meet the requirements
described in Table 4.
• T
o secure the switch to the rack, you must install not only mounting brackets, but also chassis
rails and slide rails.
Table 4 Distance requirements between the front and rear rack posts
Switch model Installation method
Minimum distance
between the front
and rear rack posts
Maximum distance
between the front
and rear rack posts
S6861-54QF
S6861-30QF
Using mounting brackets, chassis
rails, and long slide rails
621 mm (24.45 in) 793 mm (31.22 in)
Using mounting brackets, chassis
rails, and super-short slide rails
(narrow-spacing installation)
330 mm (12.99 in) 505 mm (19.88 in)
Using mounting brackets, chassis
rails, and super-short slide rails
(wide-spacing installation)
438 mm (17.24 in) 632 mm (24.88 in)
1 2
7
Switch model Installation method
Minimum distance
between the front
and rear rack posts
Maximum distance
between the front
and rear rack posts
S6861-54QT
Using mounting brackets, chassis
rails, and long slide rails
621 mm (24.45 in) 854 mm (33.62 in)
Using mounting brackets, chassis
rails, and slide rails
401 mm (15.79 in) 634 mm (24.96 in)
Attaching the mounting brackets, chassis rails, and
grounding cable to the chassis
The switch has two mounting bracket installation positions on its two sides: one near the network
port side and one near the power module side.
The switch provides a primary grounding point (with a grounding sign) and an auxiliary grounding
point.
Figure 7 Mounting bracket installation positions and grounding positions on the S6861-54QF
and S6861-30QF switches
(1) Mounting bracket installation position near the power module side
(2) Primary grounding point (3) Auxiliary grounding point
(4) Mounting bracket installation position near the port side
21
43
8
Figure 8 Mounting bracket installation positions and grounding positions on the S6861-54QT
switch
(1) Mounting bracket installation position near the power module side
(2) Primary grounding point (3) Auxiliary grounding point
(4) Mounting bracket installation position near the port side
Attaching the mounting brackets and chassis rails to the chassis
The mounting bracket and chassis rail installation methods are the same for the S6861-54QF and
S6861-30QF switches.
To attach the mounting brackets and chassis rails to the chassis:
1. Align the mounting brackets with the screw holes in the chassis. Use M4 screws (provided) to
attach the mounting brackets to the chassis.
{ To install the mounting brackets at the port side, see Figure 9, Figure 10, Figure 11,
and Figure 12.
{ To install the mounting brackets at the power module side, see Figure 13, Figure 14, Figure
15, and Figure 16.
2. A
lign the chassis rails with the rail mounting holes in the chassis:
{ If the mounting brackets are in the port-side mounting position, align the chassis rails with
the screw holes at the rear of the side panels (see Figure 9, Figure 10, Figure 11,
and Figure
12).
{ If the mounting brackets are in the power module-side mounting position, align the chassis
rails with the screw holes at the front of the side panels (see Figure 13, Figure 14, Figure 15,
and Figure 16).
3. Use M4 screws (provided) to attach the chassis rails to the chassis.
Secure the mounting brackets and chassis rails to both sides of the chassis in the same way.
To use super-short slide rails for the switch, you can install the chassis rails through
narrow-spacing or wide-spacing installation, depending on the distance between the front and
rear rack posts, as shown in Figure 10, Figure 11, Figure 14, and Figure 15.
9
Figure 9 Attaching the mounting brackets and chassis rails to an S6861-54QF switch
(mounting brackets installed near the port side)
Figure 10 Attaching the mounting brackets and chassis rails (narrow-spacing installation) to
an S6861-54QF switch (mounting brackets installed near the port side)
Figure 11 Attaching the mounting brackets and chassis rails (wide-spacing installation) to an
S6861-54QF switch (mounting brackets installed near the port side)
10
Figure 12 Attaching the mounting brackets and chassis rails to an S6861-54QT switch
(mounting brackets installed near the port side)
Figure 13 Attaching the mounting brackets and chassis rails to an S6861-54QF switch
(mounting brackets installed near the power module side)
Figure 14 Attaching the mounting brackets and chassis rails (narrow-spacing installation) to
an S6861-54QF (mounting brackets installed near the power module side)
11
Figure 15 Attaching the mounting brackets and chassis rails (wide-spacing installation) to an
S6861-54QF (mounting brackets installed near the power module side)
Figure 16 Attaching the mounting brackets and chassis rails to an S6861-54QT switch
(mounting brackets installed near the power module side)
Connecting the grounding cable to the chassis
CAUTION:
Select a grounding point as required. The primary grounding point and auxiliary grounding point are
located on the left side panel. If you use one of these grounding points, you must connect the
grounding cable to the grounding point before you mount the switch in the rack.
This section uses the primary grounding point on an S6861-54QF switch as an example.
To connect the grounding cable to a grounding point:
1. Choose a grounding point. As a best practice, use the grounding point close to the mounting
brackets.
2. Unpack the grounding cable and grounding screws.
You can use the cable and screws shipped with the switch for connecting to the primary
grounding point or auxiliary grounding point.
3. Align the two-hole grounding lug at one end of the cable with the grounding holes of the
grounding point, insert the grounding screws into the holes, and tighten the screws with a
screwdriver, as shown in Figure 17.
12
Figure 17 Attaching the grounding cable to the primary grounding point on an S6861-54QF
switch
Attaching the slide rails to the rack
The procedures are the same for attaching slide rails to the rack. This section uses the 1U long slide
rails as an example.
To attach the slide rails to the rack:
1. Identify the rack attachment position for the slide rails.
2. Install cage nuts (user-supplied) in the mounting holes in the rack posts.
3. Align the screw holes in one slide rail with the cage nuts in the rack post on one side, and use
screws (user-supplied) to attach the slide rail to the rack, as shown in Figure 18.
4. Rep
eat the preceding steps to attach the other slide rail to the rack post on the other side.
Keep the two slide rails at the same height so the slide rails can attach into the chassis rails.
Figure 18 Installing the 1U long slide rails
13
Mounting the switch in the rack
The rack-mounting procedure is similar for the switches. The following procedure mounts an
S6861-54QF switch in a rack.
This task requires two people.
To mount the switch in the rack:
1. Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
2. Verify that the mounting brackets and chassis rails have been securely attached to the switch
chassis.
3. Verify that the slide rails have been correctly attached to the rear rack posts.
4. Install cage nuts (user-supplied) to the front rack posts and make sure they are at the same
level as the slide rails.
5. One person performs the following operations:
a. Supporting the bottom of the switch, aligns the chassis rails with the slide rails on the rack
posts.
b. Pushes the switch slowly to slide the chassis rails along the slide rails until the mounting
brackets are flush with the rack posts.
6. The other person uses screws (user-supplied) to attach the mounting brackets to the rack.
If the slide rails or long slide rails are used, make sure the front ends of the slide rails or long
slide rails reach out of the chassis rails. If the super-short slide rails are used, make sure the
super-short slide rails slide a minimum length of 90 mm (3.54 in) into the chassis rails.
Figure 19 Mounting an S6861-54QF switch in the rack (mounting brackets installed near the
power module side)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57